7 resultados para Fotovoltaico Back-Contact IBC
em Aston University Research Archive
Resumo:
Purpose: The aim of this study was to compare a developmental optical coherence tomography (OCT) based contact lens inspection instrument to a widely used geometric inspection instrument (Optimec JCF), to establish the capability of a market focused OCT system. Methods: Measurements of 27 soft spherical contact lenses were made using the Optimec JCF and a new OCT based instrument, the Optimec is830. Twelve of the lenses analysed were specially commissioned from a traditional hydrogel (Contamac GM Advance 49%) and 12 from a silicone hydrogel (Contamac Definitive 65), each set with a range of back optic zone radius (BOZR) and centre thickness (CT) values. Three commercial lenses were also measured; CooperVision MyDay (Stenfilcon A) in −10D, −3D and +6D powers. Two measurements of BOZR, CT and total diameter were made for each lens in temperature controlled saline on both instruments. Results: The results showed that the is830 and JCF measurements were comparable, but that the is830 had a better repeatability coefficient for BOZR (0.065 mm compared to 0.151 mm) and CT (0.008 mm compared to 0.027 mm). Both instruments had similar results for total diameter (0.041 mm compared to 0.044 mm). Conclusions: The OCT based instrument assessed in this study is able to match and improve on the JCF instrument for the measurement of total diameter, back optic zone radius and centre thickness for soft contact lenses in temperature controlled saline.
Resumo:
The growing prevalence of type 2 diabetes is placing Scottish health services under considerable strain. Consequently, diabetes services are undergoing a major process of reorganisation, including the devolvement of routine diabetes care/diabetic review from secondary to primary healthcare settings. This qualitative study was devised to explore newly diagnosed type 2 diabetes patients' perceptions of their disease and the health services they receive at a time when this restructuring of services is taking place. The sample comprised 40 patients resident in Lothian, Scotland, who had diverse experiences of services, some receiving GP-based care only, others having varying contact with hospital diabetes clinics. In-depth interviews were undertaken with patients, three times at six monthly intervals over 1 year, enabling their experiences to be tracked at critical junctures during the post-diagnostic period. Disease perceptions and health service delivery were found to be mutually informing and effecting. Not only did (different types of) health service delivery influence the ways in which patients thought about and self-managed their disease, over time patients' disease perceptions also informed their expectations of, and preferences for, diabetes services. We thus argue that there is a need for a reconceptualisation within the medical social sciences to take into account the context of healthcare and the economic/policy factors that inform health service delivery when looking at patients' disease perceptions. We also discuss the logistical and ethical challenges of drawing upon patients' perspectives, preferences and views in the design and delivery of future health services. © 2004 Elsevier Ltd. All rights reserved.
Resumo:
The work utilising a new material for contact lenses has fallen into three parts: Physioloeical considerations: Since the cornea is devoid of blood vessels, its oxygen is derived from the atmosphere. Early hydrophilic gel contact lenses interrupted the flow of oxygen and corneal insult resulted. Three techniques of fenestration were tried to overcome this problem. High speed drilling with 0.1 mm diameter twist drills. was found to be mechanically successful, but under clinical conditions mucous blockage of the fenestrations occurred. An investigation was made into the amount of oxygen arriving at the corneal interface; related to gel lens thickness. The results indicated an improvement in corneal oxygen as lens thickness was reduced. The mechanism is thought to be a form of mechanical pump. A series of clinical studies con:firmed the experimental work; the use of thin lenses removing the symptoms of corneal hypoxia. Design: The parameters of lens back curvature. lens thickness and lens diameter have been isolated and related to three criteria of vision (a) Visual acuity. (b) Visual stability and (c) Induced astigmatism. From the results achieved a revised and basically successful design of lens has been developed. Comparative study: The developed form of lens was compared with traditional lenses in a controlled survey. Twelve factors were assessed over a twenty week period of wear using a total of eighty four patients. The results of this study indicate that whilst the expected changes were noted with the traditional lens wearers, gel lens wearers showed no discernible change in any of the factors measured. ldth the exception of' one parameter. In addition to a description of' the completed l'iork. further investigations are ·sug~ested l'lhich. it is hoped. l'iould further improve the optical performance of gel lenses.
Resumo:
FULL TEXT: Like many people one of my favourite pastimes over the holiday season is to watch the great movies that are offered on the television channels and new releases in the movie theatres or catching up on those DVDs that you have been wanting to watch all year. Recently we had the new ‘Star Wars’ movie, ‘The Force Awakens’, which is reckoned to become the highest grossing movie of all time, and the latest offering from James Bond, ‘Spectre’ (which included, for the car aficionados amongst you, the gorgeous new Aston Martin DB10). It is always amusing to see how vision correction or eye injury is dealt with by movie makers. Spy movies and science fiction movies have a freehand to design aliens with multiples eyes on stalks or retina scanning door locks or goggles that can see through walls. Eye surgery is usually shown in some kind of day case simplified laser treatment that gives instant results, apart from the great scene in the original ‘Terminator’ movie where Arnold Schwarzenegger's android character encounters an injury to one eye and then proceeds to remove the humanoid covering to this mechanical eye over a bathroom sink. I suppose it is much more difficult to try and include contact lenses in such movies. Although you may recall the film ‘Charlie's Angels’, which did have a scene where one of the Angels wore a contact lens that had a retinal image imprinted on it so she could by-pass a retinal scan door lock and an Eddy Murphy spy movie ‘I-Spy’, where he wore contact lenses that had electronic gadgetry that allowed whatever he was looking at to be beamed back to someone else, a kind of remote video camera device. Maybe we aren’t quite there in terms of devices available but these things are probably not the behest of science fiction anymore as the technology does exist to put these things together. The technology to incorporate electronics into contact lenses is being developed and I am sure we will be reporting on it in the near future. In the meantime we can continue to enjoy the unrealistic scenes of eye swapping as in the film ‘Minority Report’ (with Tom Cruise). Much more closely to home, than in a galaxy far far away, in this issue you can find articles on topics much nearer to the closer future. More and more optometrists in the UK are becoming registered for therapeutic work as independent prescribers and the number is likely to rise in the near future. These practitioners will be interested in the review paper by Michael Doughty, who is a member of the CLAE editorial panel (soon to be renamed the Jedi Council!), on prescribing drugs as part of the management of chronic meibomian gland dysfunction. Contact lenses play an active role in myopia control and orthokeratology has been used not only to help provide refractive correction but also in the retardation of myopia. In this issue there are three articles related to this topic. Firstly, an excellent paper looking at the link between higher spherical equivalent refractive errors and the association with slower axial elongation. Secondly, a paper that discusses the effectiveness and safety of overnight orthokeratology with high-permeability lens material. Finally, a paper that looks at the stabilisation of early adult-onset myopia. Whilst we are always eager for new and exciting developments in contact lenses and related instrumentation in this issue of CLAE there is a demonstration of a novel and practical use of a smartphone to assisted anterior segment imaging and suggestions of this may be used in telemedicine. It is not hard to imagine someone taking an image remotely and transmitting that back to a central diagnostic centre with the relevant expertise housed in one place where the information can be interpreted and instruction given back to the remote site. Back to ‘Star Wars’ and you will recall in the film ‘The Phantom Menace’ when Qui-Gon Jinn first meets Anakin Skywalker on Tatooine he takes a sample of his blood and sends a scan of it back to Obi-Wan Kenobi to send for analysis and they find that the boy has the highest midichlorian count ever seen. On behalf of the CLAE Editorial board (or Jedi Council) and the BCLA Council (the Senate of the Republic) we wish for you a great 2016 and ‘may the contact lens force be with you’. Or let me put that another way ‘the CLAE Editorial Board and BCLA Council, on behalf of, a great 2016, we wish for you!’
Resumo:
Minimal access procedures in surgery offer benefits of reduced patient recovery time and less pain, yet for the surgeon the task is more complex, as both tactile and visual perception of the working site is reduced. In this paper, experimental evidence of the performance of a novel sensing system embedded in an actuated flexible digit element is presented. The digit represents a steerable tip element of devices such as endoscopes and laparoscopes. This solution is able to discriminate types of contact and tissue interaction, and to feed back this information with the shape of the flexible digit. As an alternative to this information, force level, force distribution, and other quantifiable descriptors can also be evaluated. These can be used to aid perception in processes such as navigation and investigation of tissues through palpation. The solution is pragmatic, and by virtue of its efficient mechanical construction and a polymer construction, it offers opportunities for a disposable element with suitability for magnetic resonance imaging (MRI) and other scanning environments. By using only four photonics sensing elements, full perception of tissue contact and the shape of the actuated digit can be described in the feedback of this information. The distributive sensory method applied to the sensory signals relies on the coupled values of the sensory data transients of the four deployed sensing elements to discriminate tissue interaction directly in near real time.
Resumo:
I was recently part of a small committee looking at higher qualifications in contact lens practice and the discussion turned to future technologies. There was mention of different materials and different applications of contact lenses. Drug delivery with contact lenses was discussed as this has been talked about in the literature for a while. The first paper I could find that talked about using contact lenses for drug delivery dates back over 40 years. There was a review paper in CLAE in 2008 that looked specifically at this too [1]. However, where are these products? Why are we not seeing them in the market place? Maybe the technology is not quite there yet, or maybe patents are prohibiting usage or maybe the market is not big enough to develop such products? We do have lenses on the market with slow release of lubricating agents but not therapeutic agents used for ocular or systemic conditions. Contact lenses with pathogen detectors may be part of our contact lens armoury of the future and again we can already see papers in the literature that have trialled this technology for glucose monitoring in diabetics or lactate concentration in the tear film. Future contact lenses may incorporate better optics based on aberration control and we see this starting to emerge with aspheric designs designed to minimise spherical aberration. Irregular corneas can be fitted with topography based designs and again this technology exists and is being used by some manufacturers in their designs already. Moreover, the topography based fitting of irregular corneas is certainly something we see a lot of today and CLAE has seen many articles related to this over the last decade or so. What about further into the future? Well one interesting area must the 3-dimensional contact lenses, or contact lenses with electronic devices built in that simulate a display screen. A little like the virtual display spectacles that are already sold by electronics companies. It does not take much of a stretch of the imagination to see a large electronic company taking this technology on and making it viable. Will we see people on the train watching movies on these electronic virtual reality contact lenses? I think we will, but when is harder to know.
Resumo:
Minimal access procedures in surgery offer benefits of reduced patient recovery time and less pain, yet for the surgeon the task is more complex, as both tactile and visual perception of the working site is reduced. In this paper, experimental evidence of the performance of a novel sensing system embedded in an actuated flexible digit element is presented. The digit represents a steerable tip element of devices such as endoscopes and laparoscopes. This solution is able to discriminate types of contact and tissue interaction, and to feed back this information with the shape of the flexible digit. As an alternative to this information, force level, force distribution, and other quantifiable descriptors can also be evaluated. These can be used to aid perception in processes such as navigation and investigation of tissues through palpation. The solution is pragmatic, and by virtue of its efficient mechanical construction and a polymer construction, it offers opportunities for a disposable element with suitability for magnetic resonance imaging (MRI) and other scanning environments. By using only four photonics sensing elements, full perception of tissue contact and the shape of the actuated digit can be described in the feedback of this information. The distributive sensory method applied to the sensory signals relies on the coupled values of the sensory data transients of the four deployed sensing elements to discriminate tissue interaction directly in near real time.