7 resultados para Faults (Geology)

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research carried out in this thesis was mainly concerned with the effects of large induction motors and their transient performance in power systems. Computer packages using the three phase co-ordinate frame of reference were developed to simulate the induction motor transient performance. A technique using matrix algebra was developed to allow extension of the three phase co-ordinate method to analyse asymmetrical and symmetrical faults on both sides of the three phase delta-star transformer which is usually required when connecting large induction motors to the supply system. System simulation, applying these two techniques, was used to study the transient stability of a power system. The response of a typical system, loaded with a group of large induction motors, two three-phase delta-star transformers, a synchronous generator and an infinite system was analysed. The computer software developed to study this system has the advantage that different types of fault at different locations can be studied by simple changes in input data. The research also involved investigating the possibility of using different integrating routines such as Runge-Kutta-Gill, RungeKutta-Fehlberg and the Predictor-Corrector methods. The investigation enables the reduction of computation time, which is necessary when solving the induction motor equations expressed in terms of the three phase variables. The outcome of this investigation was utilised in analysing an introductory model (containing only minimal control action) of an isolated system having a significant induction motor load compared to the size of the generator energising the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnosing faults in wastewater treatment, like diagnosis of most problems, requires bi-directional plausible reasoning. This means that both predictive (from causes to symptoms) and diagnostic (from symptoms to causes) inferences have to be made, depending on the evidence available, in reasoning for the final diagnosis. The use of computer technology for the purpose of diagnosing faults in the wastewater process has been explored, and a rule-based expert system was initiated. It was found that such an approach has serious limitations in its ability to reason bi-directionally, which makes it unsuitable for diagnosing tasks under the conditions of uncertainty. The probabilistic approach known as Bayesian Belief Networks (BBNS) was then critically reviewed, and was found to be well-suited for diagnosis under uncertainty. The theory and application of BBNs are outlined. A full-scale BBN for the diagnosis of faults in a wastewater treatment plant based on the activated sludge system has been developed in this research. Results from the BBN show good agreement with the predictions of wastewater experts. It can be concluded that the BBNs are far superior to rule-based systems based on certainty factors in their ability to diagnose faults and predict systems in complex operating systems having inherently uncertain behaviour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the geology of a Lower Palaeozoic terrain, situated west of the town of Fishguard, SW Dyfed, Wales. The area is dominated by the Fishguard Volcanic Complex (Upper Llanvirn), and sediments that range in age from the Middle Cambrian to the Lower Llandeilo. The successions represent an insight into sedimentation and volcanism for c. 100 Ma. along the south-western margin of the Lower Palaeozoic Welsh Basin. The stratigraphy of the sedimentary sequence has been completely revised and the existing volcanostratigraphy modified. The observed complexity of the stratigraphy is primarily the consequence of Caldedonide deformation which resulted in large scale repetition. Fold-thrust tectonics dominates the structural style of the area. Caledonide trending (NE-SW) cross-faults complicate preexisting structures. Middle Cambrian (?) sedimentation is documented by shallow marine clastics and red shales deposited within tidal - subtidal environments. Upper Cambrian sedimentation was dominated by shallow marine `storm' and `fair weather' sedimentation within a muddy shelf environment. Shallow marine conglomerates and heterolithic intertidal siliciclastics mark the onset of Ordovician sedimentation during the lower Arenig transgression. Mid-Arenig sediments reflect deposits influenced by storm, fair-weather and wave related processes in various shallow marine environments, including; shoreface, inner shelf, shoaling bar, and deltaic. Graptolitic marine shales were deposited from the upper mid-Arenig through to the lower Llandeilo; during which time sediments accumulated by pelagic processes and fine grained turbidites. The varied nature of sedimentation reflects both localised change within the depositional system and the influence of larger regional eustatic events. Ordovician subaqueous volcanic activity produced thick accumulations of lavas, pyroclastics, hydroclastics, and hyaloclastics. The majority of volcanism was effusive in nature, erupted below the Pressure Compensation Level. Basaltic volcanism was characterised by pillowed lavas and tube networks, whilst sheet-flow lavas, pillow breccias and minor hyaloclastites developed locally. Silicic volcanism was dominated by rhyolitic clastics of various affinities, although coherent silicic obsidian lavas, sheet-flow lavas and pyroclastics developed. Hypabyssal intrusives of variable composition and habit occur throughout the volcanic successions. Low-grade regional metamorphism has variably affected the area, conditions of the prehnite-pumpellyite and greenschist facies having been attained. Numerous secondary phases developed in response to the conditions imposed, which collectively indicate that P-T conditions were of low-pressure facies series in the range P= 1.2-2.0 kbars and T= 230-350oC, under an elevated geothermal gradient of 40-45oC km-1. Polymineralic cataclastites associated with Caledonide deformation indicate that tectonism and metamorphism were in part contemporaneous.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reliability of power converters is of crucial importance in switched reluctance motor drives used for safety-critical applications. Open-circuit faults in power converters will cause the motor to run in unbalanced states, and if left untreated, they will lead to damage to the motor and power modules, and even cause a catastrophic failure of the whole drive system. This study is focused on using a single current sensor to detect open-circuit faults accurately. An asymmetrical half-bridge converter is considered in this study and the faults of single-phase open and two-phase open are analysed. Three different bus positions are defined. On the basis of a fast Fourier transform algorithm with Blackman window interpolation, the bus current spectrums before and after open-circuit faults are analysed in details. Their fault characteristics are extracted accurately by the normalisations of the phase fundamental frequency component and double phase fundamental frequency component, and the fault characteristics of the three bus detection schemes are also compared. The open-circuit faults can be located by finding the relationship between the bus current and rotor position. The effectiveness of the proposed diagnosis method is validated by the simulation results and experimental tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photovoltaic (PV) solar power generation is proven to be effective and sustainable but is currently hampered by relatively high costs and low conversion efficiency. This paper addresses both issues by presenting a low-cost and efficient temperature distribution analysis for identifying PV module mismatch faults by thermography. Mismatch faults reduce the power output and cause potential damage to PV cells. This paper first defines three fault categories in terms of fault levels, which lead to different terminal characteristics of the PV modules. The investigation of three faults is also conducted analytically and experimentally, and maintenance suggestions are also provided for different fault types. The proposed methodology is developed to combine the electrical and thermal characteristics of PV cells subjected to different fault mechanisms through simulation and experimental tests. Furthermore, the fault diagnosis method can be incorporated into the maximum power point tracking schemes to shift the operating point of the PV string. The developed technology has improved over the existing ones in locating the faulty cell by a thermal camera, providing a remedial measure, and maximizing the power output under faulty conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a diagnostic and prognostic condition monitoring method for insulated-gate bipolar transistor (IGBT) power modules for use primarily in electric vehicle applications. The wire-bond-related failure, one of the most commonly observed packaging failures, is investigated by analytical and experimental methods using the on-state voltage drop as a failure indicator. A sophisticated test bench is developed to generate and apply the required current/power pulses to the device under test. The proposed method is capable of detecting small changes in the failure indicators of the IGBTs and freewheeling diodes and its effectiveness is validated experimentally. The novelty of the work lies in the accurate online testing capacity for diagnostics and prognostics of the power module with a focus on the wire bonding faults, by injecting external currents into the power unit during the idle time. Test results show that the IGBT may sustain a loss of half the bond wires before the impending fault becomes catastrophic. The measurement circuitry can be embedded in the IGBT drive circuits and the measurements can be performed in situ when the electric vehicle stops in stop-and-go, red light traffic conditions, or during routine servicing.