7 resultados para Faecal Occult Blood test (FOBt)

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Cancer-related self-tests are currently available to buy in pharmacies or over the internet, including tests for faecal occult blood, PSA and haematuria. Self-tests have potential benefits (e.g. convenience) but there are also potential harms (e.g. delays in seeking treatment). The extent of cancer-related self-test use in the UK is not known. This study aimed to determine the prevalence of cancer-related self-test use. Methods: Adults (n = 5,545) in the West Midlands were sent a questionnaire that collected socio-demographic information and data regarding previous and potential future use of 18 different self-tests. Prevalence rates were directly standardised to the England population. The postcode based Index of Multiple Deprivation 2004 was used as aproxy measure of deprivation. Results: 2,925 (54%) usable questionnaires were returned. 1.2% (95% CI 0.83% to 1.66%) of responders reported having used a cancer related self test kit and a further 36% reported that they would consider using one in the future. Logistic regression analyses suggest that increasing age, deprivation category and employment status were associated with cancer-related self-test kit use. Conclusion: We conclude that one in 100 of the adult population have used a cancer-related self-test kit and over a third would consider using one in the future. Self-test kit use could alter perceptions of risk, cause psychological morbidity and impact on the demand for healthcare.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Self-tests are those where an individual can obtain a result without recourse to a health professional, by getting a result immediately or by sending a sample to a laboratory that returns the result directly. Self-tests can be diagnostic, for disease monitoring, or both. There are currently tests for more than 20 different conditions available to the UK public, and self-testing is marketed as a way of alerting people to serious health problems so they can seek medical help. Almost nothing is known about the extent to which people self-test for cancer or why they do this. Self-tests for cancer could alter perceptions of risk and health behaviour, cause psychological morbidity and have a significant impact on the demand for healthcare. This study aims to gain an understanding of the frequency of self-testing for cancer and characteristics of users. Methods: Cross-sectional survey. Adults registered in participating general practices in the West Midlands Region, will be asked to complete a questionnaire that will collect socio-demographic information and basic data regarding previous and potential future use of self-test kits. The only exclusions will be people who the GP feels it would be inappropriate to send a questionnaire, for example because they are unable to give informed consent. Freepost envelopes will be included and non-responders will receive one reminder. Standardised prevalence rates will be estimated. Discussion: Cancer related self-tests, currently available from pharmacies or over the Internet, include faecal occult blood tests (related to bowel cancer), prostate specific antigen tests (related to prostate cancer), breast cancer kits (self examination guide) and haematuria tests (related to urinary tract cancers). The effect of an increase in self-testing for cancer is unknown but may be considerable: it may affect the delivery of population based screening programmes; empower patients or cause unnecessary anxiety; reduce costs on existing healthcare services or increase demand to investigate patients with positive test results. It is important that more is known about the characteristics of those who are using self-tests if we are to determine the potential impact on health services and the public. © 2006 Wilson et al; licensee BioMed Central Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim: To evaluate OneTouch® Verio™ test strip performance at hypoglycaemic blood glucose (BG) levels (<3.9mmol/L [<70mg/dL]) at seven clinical studies. Methods: Trained clinical staff performed duplicate capillary BG monitoring system tests on 700 individuals with type 1 and type 2 diabetes using blood from a single fingerstick lancing. BG reference values were obtained using a YSI 2300 STAT™ Glucose Analyzer. The number and percentage of BG values within ±0.83. mmol/L (±15. mg/dL) and ±0.56. mmol/L (±10. mg/dL) were calculated at BG concentrations of <3.9. mmol/L (<70. mg/dL), <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL). Results: At BG concentrations <3.9. mmol/L (<70. mg/dL), 674/674 (100%) of meter results were within ±0.83. mmol/L (±15. mg/dL) and 666/674 (98.8%) were within ±0.56. mmol/L (±10. mg/dL) of reference values. At BG concentrations <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL), 358/358 (100%) and 270/270 (100%) were within ±0.56. mmol/L (±10. mg/dL) of reference values, respectively. Conclusion: In this analysis of data from seven independent studies, OneTouch Verio test strips provide highly accurate results at hypoglycaemic BG levels. © 2012 Elsevier Ireland Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this investigation was to design a novel magnetic drive and bearing system for a new centrifugal rotary blood pump (CRBP). The drive system consists of two components: (i) permanent magnets within the impeller of the CRBP; and (ii) the driving electromagnets. Orientation of the magnets varies from axial through to 60° included out-lean (conical configuration). Permanent magnets replace the electromagnet drive to allow easier characterization. The performance characteristics tested were the axial force of attraction between the stator and rotor at angles of rotational alignment, Ø, and the corresponding torque at those angles. The drive components were tested for various magnetic cone angles, ?. The test was repeated for three backing conditions: (i) non-backed; (ii) steel-cupped; and (iii) steel plate back-iron, performed on an Instron tensile testing machine. Experimental results were expanded upon through finite element and boundary element analysis (BEM). The force/torque characteristics were maximal for a 12-magnet configuration at 0° cone angle with steel-back iron (axial force = 60 N, torque = 0.375 Nm). BEM showed how introducing a cone angle increases the radial restoring force threefold while not compromising axial bearing force. Magnets in the drive system may be orientated not only to provide adequate coupling to drive the CRBP, but to provide significant axial and radial bearing forces capable of withstanding over 100 m/s2 shock excitation on the impeller. Although the 12 magnet 0° (?) configuration yielded the greatest force/torque characteristic, this was seen as potentially unattractive as this magnetic cone angle yielded poor radial restoring force characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Breast cancer resistance protein (BCRP/ABCG2) is a drug efflux transporter expressed at the blood cerebrospinal fluid barrier (BCSFB), and influences distribution of drugs into the central nervous systems (CNS). Current inhibitors have failed clinically due to neurotoxicity. Novel approaches are needed to identify new modulators to enhance CNS delivery. This study examines 18 compounds (mainly phytoestrogens) as modulators of the expression/function of BCRP in an in vitro rat choroid plexus BCSFB model. METHODS: Modulators were initially subject to cytotoxicity (MTT) assessment to determine optimal non-toxic concentrations. Reverse-transcriptase PCR and confocal microscopy were used to identify the presence of BCRP in Z310 cells. Thereafter modulation of the intracellular accumulation of the fluorescent BCRP probe substrate Hoechst 33342 (H33342), changes in protein expression of BCRP (western blotting) and the functional activity of BCRP (membrane insert model) were assessed under modulator exposure. RESULTS: A 24 hour cytotoxicity assay (0.001 µM-1000 µM) demonstrated the majority of modulators possessed a cellular viability IC50 > 148 µM. Intracellular accumulation of H33342 was significantly increased in the presence of the known BCRP inhibitor Ko143 and, following a 24 hour pre-incubation, all modulators demonstrated statistically significant increases in H33342 accumulation (P < 0.001), when compared to control and Ko143. After a 24 hour pre-incubation with modulators alone, a 0.16-2.5-fold change in BCRP expression was observed for test compounds. The functional consequences of this were confirmed in a permeable insert model of the BCSFB which demonstrated that 17-β-estradiol, naringin and silymarin (down-regulators) and baicalin (up-regulator) can modulate BCRP-mediated transport function at the BCSFB. CONCLUSION: We have successfully confirmed the gene and protein expression of BCRP in Z310 cells and demonstrated the potential for phytoestrogen modulators to influence the functionality of BCRP at the BCSFB and thereby potentially allowing manipulation of CNS drug disposition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To test the hypothesis of a significant relationship between systemic markers of renal and vascular function (processes linked to cardiovascular disease and its development) and retinal microvascular function in diabetes and/or cardiovascular disease.Methods: Ocular microcirculatory function was measured in 116 patients with diabetes and/or cardiovascular disease using static and continuous retinal vessel responses to three cycles of flickering light. Endothelial function was evaluated by von Willebrand factor (vWf), endothelial microparticles and soluble E selectin, renal function by serum creatinine, creatinine clearance and estimated glomerular filtration rate (eGFR). HbA1c was used as a control index.Results: Central retinal vein equivalence and venous maximum dilation to flicker were linked to HbA1c (both p<0.05). Arterial reaction time was linked to serum creatinine (p=0.036) and eGFR (p=0.039), venous reaction time was linked to creatinine clearance (p=0.018). Creatinine clearance and eGFR were linked to arterial maximum dilatation (p<0.001 and p=0.003 respectively) and the dilatation amplitude (p=0.038 and p=0.048 respectively) responses in the third flicker cycle. Of venous responses to the first flicker cycle, HbA1c was linked to the maximum dilation response (p=0.004) and dilatation amplitude (p=0.017), vWf was linked to the maximum constriction response (p=0.016), and creatinine clearance to the baseline diameter fluctuation (p=0.029). In the second flicker cycle, dilatation amplitude was linked to serum creatinine (p=0.022). Conclusions: Several retinal blood vessel responses to flickering light are linked to glycaemia and renal function, but only one index is linked to endothelial function. Renal function must be considered when interpreting retinal vessel responses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Most studies reporting evidence of adverse effects of lead and cadmium on the ability to balance have been conducted in high-exposure groups or have included adults. The effects of prenatal exposure have not been well studied, nor have the effects in children been directly studied. The aim of the study was to identify the associations of lead (in utero and in childhood) and cadmium (in utero) exposure with the ability to balance in children aged 7 and 10 years. DESIGN: Prospective birth cohort study. PARTICIPANTS: Maternal blood lead (n=4285) and cadmium (n=4286) levels were measured by inductively coupled plasma mass spectrometry in women enrolled in the Avon Longitudinal Study of Parents and Children (ALSPAC) during pregnancy. Child lead levels were measured in a subsample of 582 of ALSPAC children at age 30 months. MAIN OUTCOME MEASURES: Children completed a heel-to-toe walking test at 7 years. At 10 years, the children underwent clinical tests of static and dynamic balance. Statistical analysis using SPSS V.19 included logistic regression modelling, comparing categories of ≥ 5 vs <5 µg/dL for lead, and ≥ 1 vs <1 µg/L for cadmium. RESULTS: Balance at age 7 years was not associated with elevated in utero lead or cadmium exposure (adjusted OR for balance dysfunction: Pb 1.01 (95% CI 0.95 to 1.01), n=1732; Cd 0.95 (0.77 to 1.20), n=1734), or with elevated child blood lead level at age 30 months (adjusted OR 0.98 (0.92 to 1.05), n=354). Similarly, neither measures of static nor dynamic balance at age 10 years were associated with in utero lead or cadmium exposure, or child lead level. CONCLUSIONS: These findings do not provide any evidence of an association of prenatal exposure to lead or cadmium, or lead levels in childhood, on balance ability in children. Confirmation in other cohorts is needed.