16 resultados para Electronically interfaced

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The realisation of an eventual low-voltage (LV) Smart Grid with a complete communication infrastructure is a gradual process. During this evolution the protection scheme of distribution networks should be continuously adapted and optimised to fit the protection and cost requirements at the time. This paper aims to review practices and research around the design of an effective, adaptive and economical distribution network protection scheme. The background of this topic is introduced and potential problems are defined from conventional protection theories and new Smart Grid technologies. Challenges are identified with possible solutions defined as a pathway to the ultimate flexible and reliable LV protection systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sieve plate distillation column has been constructed and interfaced to a minicomputer with the necessary instrumentation for dynamic, estimation and control studies with special bearing on low-cost and noise-free instrumentation. A dynamic simulation of the column with a binary liquid system has been compiled using deterministic models that include fluid dynamics via Brambilla's equation for tray liquid holdup calculations. The simulation predictions have been tested experimentally under steady-state and transient conditions. The simulator's predictions of the tray temperatures have shown reasonably close agreement with the measured values under steady-state conditions and in the face of a step change in the feed rate. A method of extending linear filtering theory to highly nonlinear systems with very nonlinear measurement functional relationships has been proposed and tested by simulation on binary distillation. The simulation results have proved that the proposed methodology can overcome the typical instability problems associated with the Kalman filters. Three extended Kalman filters have been formulated and tested by simulation. The filters have been used to refine a much simplified model sequentially and to estimate parameters such as the unmeasured feed composition using information from the column simulation. It is first assumed that corrupted tray composition measurements are made available to the filter and then corrupted tray temperature measurements are accessed instead. The simulation results have demonstrated the powerful capability of the Kalman filters to overcome the typical hardware problems associated with the operation of on-line analyzers in relation to distillation dynamics and control by, in effect, replacirig them. A method of implementing estimator-aided feedforward (EAFF) control schemes has been proposed and tested by simulation on binary distillation. The results have shown that the EAFF scheme provides much better control and energy conservation than the conventional feedback temperature control in the face of a sustained step change in the feed rate or multiple changes in the feed rate, composition and temperature. Further extensions of this work are recommended as regards simulation, estimation and EAFF control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work reports the developnent of a mathenatical model and distributed, multi variable computer-control for a pilot plant double-effect climbing-film evaporator. A distributed-parameter model of the plant has been developed and the time-domain model transformed into the Laplace domain. The model has been further transformed into an integral domain conforming to an algebraic ring of polynomials, to eliminate the transcendental terms which arise in the Laplace domain due to the distributed nature of the plant model. This has made possible the application of linear control theories to a set of linear-partial differential equations. The models obtained have well tracked the experimental results of the plant. A distributed-computer network has been interfaced with the plant to implement digital controllers in a hierarchical structure. A modern rnultivariable Wiener-Hopf controller has been applled to the plant model. The application has revealed a limitation condition that the plant matrix should be positive-definite along the infinite frequency axis. A new multi variable control theory has emerged fram this study, which avoids the above limitation. The controller has the structure of the modern Wiener-Hopf controller, but with a unique feature enabling a designer to specify the closed-loop poles in advance and to shape the sensitivity matrix as required. In this way, the method treats directly the interaction problems found in the chemical processes with good tracking and regulation performances. Though the ability of the analytical design methods to determine once and for all whether a given set of specifications can be met is one of its chief advantages over the conventional trial-and-error design procedures. However, one disadvantage that offsets to some degree the enormous advantages is the relatively complicated algebra that must be employed in working out all but the simplest problem. Mathematical algorithms and computer software have been developed to treat some of the mathematical operations defined over the integral domain, such as matrix fraction description, spectral factorization, the Bezout identity, and the general manipulation of polynomial matrices. Hence, the design problems of Wiener-Hopf type of controllers and other similar algebraic design methods can be easily solved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is known that distillation tray efficiency depends on the liquid flow pattern, particularly for large diameter trays. Scale·up failures due to liquid channelling have occurred, and it is known that fitting flow control devices to trays sometirr.es improves tray efficiency. Several theoretical models which explain these observations have been published. Further progress in understanding is at present blocked by lack of experimental measurements of the pattern of liquid concentration over the tray. Flow pattern effects are expected to be significant only on commercial size trays of a large diameter and the lack of data is a result of the costs, risks and difficulty of making these measurements on full scale production columns. This work presents a new experiment which simulates distillation by water cooling. and provides a means of testing commercial size trays in the laboratory. Hot water is fed on to the tray and cooled by air forced through the perforations. The analogy between heat and mass transfer shows that the water temperature at any point is analogous to liquid concentration and the enthalpy of the air is analogous to vapour concentration. The effect of the liquid flow pattern on mass transfer is revealed by the temperature field on the tray. The experiment was implemented and evaluated in a column of 1.2 m. dia. The water temperatures were measured by thennocouples interfaced to an electronic computerised data logging system. The "best surface" through the experimental temperature measurements was obtained by the mathematical technique of B. splines, and presented in tenos of lines of constant temperature. The results revealed that in general liquid channelling is more imponant in the bubbly "mixed" regime than in the spray regime. However, it was observed that severe channelling also occurred for intense spray at incipient flood conditions. This is an unexpected result. A computer program was written to calculate point efficiency as well as tray efficiency, and the results were compared with distillation efficiencies for similar loadings. The theoretical model of Porter and Lockett for predicting distillation was modified to predict water cooling and the theoretical predictions were shown to be similar to the experimental temperature profiles. A comparison of the repeatability of the experiments with an errors analysis revealed that accurate tray efficiency measurements require temperature measurements to better than ± 0.1 °c which is achievable with conventional techniques. This was not achieved in this work, and resulted in considerable scatter in the efficiency results. Nevertheless it is concluded that the new experiment is a valuable tool for investigating the effect of the liquid flow pattern on tray mass transfer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experimental investigations and computer modelling studies have been made on the refrigerant-water counterflow condenser section of a small air to water heat pump. The main object of the investigation was a comparative study between the computer modelling predictions and the experimental observations for a range of operating conditions but other characteristics of a counterflow heat exchanger are also discussed. The counterflow condenser consisted of 15 metres of a thermally coupled pair of copper pipes, one containing the R12 working fluid and the other water flowing in the opposite direction. This condenser was mounted horizontally and folded into 0.5 metre straight sections. Thermocouples were inserted in both pipes at one metre intervals and transducers for pressure and flow measurement were also included. Data acquisition, storage and analysis was carried out by a micro-computer suitably interfaced with the transducers and thermocouples. Many sets of readings were taken under a variety of conditions, with air temperature ranging from 18 to 26 degrees Celsius, water inlet from 13.5 to 21.7 degrees, R12 inlet temperature from 61.2 to 81.7 degrees and water mass flow rate from 6.7 to 32.9 grammes per second. A Fortran computer model of the condenser (originally prepared by Carrington[1]) has been modified to match the information available from experimental work. This program uses iterative segmental integration over the desuperheating, mixed phase and subcooled regions for the R12 working fluid, the water always being in the liquid phase. Methods of estimating the inlet and exit fluid conditions from the available experimental data have been developed for application to the model. Temperature profiles and other parameters have been predicted and compared with experimental values for the condenser for a range of evaporator conditions and have shown that the model gives a satisfactory prediction of the physical behaviour of a simple counterflow heat exchanger in both single phase and two phase regions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To identify the types, prevalence and nature of antibiotic prescribing control documents within NHS hospitals in the UK. Methods: A self-completion postal questionnaire was sent to each Chief Pharmacist at 465 NHS hospitals in 2001/2002. This contained questions covering hospital demographics, and hospital antibiotic prescribing control documentation, including format, dissemination, approval and review processes. Results: In total, 253 (54%) completed questionnaires were returned. Of these, 168 respondents' hospitals had an antibiotic formulary, 107 had a policy for antibiotic prescribing and 216 had guidelines on antibiotic use. All three types of antibiotic prescribing documents were used by 82 hospitals but 18 did not have any documents; 44% of formularies, 45% of policies and 35% of guidelines were available electronically. The Drug and Therapeutics Committee was the most frequently cited body for document approval and approximately one-third of documents had been approved during the current year of the questionnaire. Only about one-half of responding hospitals had an annual review of documents. Conclusions: Despite publication of high-profile national guidance in response to growing concerns regarding antimicrobial resistance, there has been little increase in the use of antibiotic prescribing control documents in NHS hospitals over the past decade. It is clear that appropriate controls for antibiotic prescribing are not yet universally applied in the UK and recommendations for action have been proposed. © The British Society for Antimicrobial Chemotherapy 2004; all rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of antibiotics was investigated in twelve acute hospitals in England. Data was collected electronically and by questionnaire for the financial years 2001/2, 2002/3 and 2003/4. Hospitals were selected on the basis of their Medicines Management Self-Assessment Scores (MMAS) and included a cohort of three hospitals with integrated electronic prescribing systems. The total sample size was 6.65% of English NHS activity for 2001/2 based on Finished Consultant Episode (FCE) numbers. Data collected included all antibiotics dispensed (ATC category J01), hospital activity FCE's and beddays, Medicines Management Self-assessment scores, Antibiotic Medicines Management scores (AMS), Primary Care Trust (PCT) of origin of referral populations, PCT antibiotic prescribing rates, Index of Multiple Deprivation for each PCT. The DDD/FCE (Defined Daily Dose/FCE) was found to correlate with the DDD 100beddays (r = 0.74 p

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is now recognised that redox control of proteins plays an important role in many signalling pathways both in health and disease. Proteins can undergo a wide variety of oxidative post-translational modifications (oxPTM); while the reversible modifications are thought to be most important in physiological processes, non-reversible oxPTM may contribute to pathological situations and disease. The oxidant is also important in determining the type of oxPTM (chlorination, nitration, etc.), and the susceptibilities of residues vary depending on their structural location. The best characterized oxPTMs involved in signalling modulation are partial oxidations of cysteine to the disulfide, glutathionylated or sulfenic acid forms, but there is increasing evidence that specific oxidations of methionine and tyrosine may have some biological roles. Well understood examples of oxidative regulation include protein tyrosine phosphatases, e.g. PTP1B/C, and members of the MAPK pathways such as MEKK1 and ASK1. Transcription factors such as NFkB and Nrf-2 are also regulated by redox-active cysteines. Improved methods for analysing specific oxPTMs in biological samples are critical for understanding the physiological and pathological roles of these changes, and tandem or MS3 mass spectrometry techniques interfaced with nano-LC separation are being now used. MS3 fragmentation markers for a variety of oxidized residues including tyrosine, tryptophan and proline have been identified, and a precursor ion scanning method that allows the selective identification of these oxPTMs in complex samples has been developed. Such advances in technology offer potential for biomarker development, disease diagnosis and understanding pathology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective - To review and summarise published data on medication errors in older people with mental health problems. Methods - A systematic review was conducted to identify studies that investigated medication errors in older people with mental health problems. MEDLINE, EMBASE, PHARMLINE, COCHRANE COLLABORATION and PsycINFO were searched electronically. Any studies identified were scrutinized for further references. The title, abstract or full text was systematically reviewed for relevance. Results - Data were extracted from eight studies. In total, information about 728 errors (459 administration, 248 prescribing, 7 dispensing, 12 transcribing, 2 unclassified) was available. The dataset related almost exclusively to inpatients, frequently involved non-psychotropics, and the majority of the errors were not serious. Conclusions - Due to methodology issues it was impossible to calculate overall error rates. Future research should concentrate on serious errors within community settings, and clarify potential risk factors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This brief commentary on the paper Designing Research with In-built Differentiated Replication expands on concerns about a lack of replication research by focusing on three key questions of continuous importance: Why should researchers conduct more replication research? Why do so few researchers conduct replication studies? What can researchers do to add more studies? This paper identifies barriers preventing replication related to the scientific system, the replication researcher, and the initial research. Suggestions include publishing all papers electronically along with reviews; authors taking steps to encourage replications of their work; and editors inviting replications of important papers. The scientific community should establish a replication index as a measure of output quality. © 2012 Elsevier Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Precision agriculture (PA) describes a suite of IT based tools which allow farmers to electronically monitor soil and crop conditions and analyze treatment options. This study tests a model explaining the difficulties of PA technology adoption. The model draws on theories of technology acceptance and diffusion of innovation and is validated using survey data from farms in Canada. Findings highlight the importance of compatibility among PA technology components and the crucial role of farmers' expertise. The model provides the theoretical and empirical basis for developing policies and initiatives to support PA technology adoption.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sizeable amount of the testing in eye care, requires either the identification of targets such as letters to assess functional vision, or the subjective evaluation of imagery by an examiner. Computers can render a variety of different targets on their monitors and can be used to store and analyse ophthalmic images. However, existing computing hardware tends to be large, screen resolutions are often too low, and objective assessments of ophthalmic images unreliable. Recent advances in mobile computing hardware and computer-vision systems can be used to enhance clinical testing in optometry. High resolution touch screens embedded in mobile devices, can render targets at a wide variety of distances and can be used to record and respond to patient responses, automating testing methods. This has opened up new opportunities in computerised near vision testing. Equally, new image processing techniques can be used to increase the validity and reliability of objective computer vision systems. Three novel apps for assessing reading speed, contrast sensitivity and amplitude of accommodation were created by the author to demonstrate the potential of mobile computing to enhance clinical measurement. The reading speed app could present sentences effectively, control illumination and automate the testing procedure for reading speed assessment. Meanwhile the contrast sensitivity app made use of a bit stealing technique and swept frequency target, to rapidly assess a patient’s full contrast sensitivity function at both near and far distances. Finally, customised electronic hardware was created and interfaced to an app on a smartphone device to allow free space amplitude of accommodation measurement. A new geometrical model of the tear film and a ray tracing simulation of a Placido disc topographer were produced to provide insights on the effect of tear film breakdown on ophthalmic images. Furthermore, a new computer vision system, that used a novel eye-lash segmentation technique, was created to demonstrate the potential of computer vision systems for the clinical assessment of tear stability. Studies undertaken by the author to assess the validity and repeatability of the novel apps, found that their repeatability was comparable to, or better, than existing clinical methods for reading speed and contrast sensitivity assessment. Furthermore, the apps offered reduced examination times in comparison to their paper based equivalents. The reading speed and amplitude of accommodation apps correlated highly with existing methods of assessment supporting their validity. Their still remains questions over the validity of using a swept frequency sine-wave target to assess patient’s contrast sensitivity functions as no clinical test provides the range of spatial frequencies and contrasts, nor equivalent assessment at distance and near. A validation study of the new computer vision system found that the authors tear metric correlated better with existing subjective measures of tear film stability than those of a competing computer-vision system. However, repeatability was poor in comparison to the subjective measures due to eye lash interference. The new mobile apps, computer vision system, and studies outlined in this thesis provide further insight into the potential of applying mobile and image processing technology to enhance clinical testing by eye care professionals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A compact, fiber-based spectrometer for biomedical application utilizing a tilted fiber Bragg grating (TFBG) as integrated dispersive element is demonstrated. Based on a 45° UV-written PS750 TFBG a refractive spectrometer with 2.06 radiant/μm dispersion and a numerical aperture of 0.1 was set up and tested as integrated detector for an optical coherence tomography (OCT) system. Featuring a 23 mm long active region at the fiber the spectrum is projected via a cylindrical lens for vertical beam collimation and focused by an achromatic doublet onto the detector array. Covering 740 nm to 860 nm the spectrometer was optically connected to a broadband white light interferometer and a wide field scan head and electronically to an acquisition and control computer. Tomograms of ophthalmic and dermal samples obtained by the frequency domain OCT-system were obtained achieving 2.84 μm axial and 7.6 μm lateral resolution. © 2014 SPIE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Phospholipid oxidation by adventitious damage generates a wide variety of products with potentially novel biological activities that can modulate inflammatory processes associated with various diseases. To understand the biological importance of oxidised phospholipids (OxPL) and their potential role as disease biomarkers requires precise information about the abundance of these compounds in cells and tissues. There are many chemiluminescence and spectrophotometric assays available for detecting oxidised phospholipids, but they all have some limitations. Mass spectrometry coupled with liquid chromatography is a powerful and sensitive approach that can provide detailed information about the oxidative lipidome, but challenges still remain. The aim of this work is to develop improved methods for detection of OxPLs by optimisation of chromatographic separation through testing several reverse phase columns and solvent systems, and using targeted mass spectrometry approaches. Initial experiments were carried out using oxidation products generated in vitro to optimise the chromatography separation parameters and mass spectrometry parameters. We have evaluated the chromatographic separation of oxidised phosphatidylcholines (OxPCs) and oxidised phosphatidylethanolamines (OXPEs) using C8, C18 and C30 reverse phase, polystyrene – divinylbenzene based monolithic and mixed – mode hydrophilic interaction (HILIC) columns, interfaced with mass spectrometry. Our results suggest that the monolithic column was best able to separate short chain OxPCs and OxPEs from long chain oxidised and native PCs and PEs. However, variation in charge of polar head groups and extreme diversity of oxidised species make analysis of several classes of OxPLs within one analytical run impractical. We evaluated and optimised the chromatographic separation of OxPLs by serially coupling two columns: HILIC and monolith column that provided us the larger coverage of OxPL species in a single analytical run.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Hospital discharge is a transition of care, where medication discrepancies are likely to occur and potentially cause patient harm. The purpose of our study was to assess the prescribing accuracy of hospital discharge medication orders at a London, UK teaching hospital. The timeliness of the discharge summary reaching the general practitioner (GP, family physician) was also assessed based on the 72 h target referenced in the Care Quality Commission report.1 Method: 501 consecutive discharge medication orders from 142 patients were examined and the following records were compared (1) the final inpatient drug chart at the point of discharge, (2) printed signed copy of the initial to take away (TTA) discharge summary produced electronically by the physician, (3) the pharmacist's amendments on the initial TTA that were hand written, (4) the final electronic patient discharge summary record, (5) the patients final take home medication from the hospital. Discrepancies between the physician's order (6) and pharmacist's change(s) (7) were compared with two types of failures – ‘failure to make a required change’ and ‘change where none was required’. Once the patient was discharged, the patient's GP, was contacted 72 h after discharge to see if the patient discharge summary, sent by post or via email, was received. Results: Over half the patients seen (73 out of 142) patients had at least one discrepancy that was made on the initial TTA by the doctor and amended by the pharmacist. Out of the 501 drugs, there were 140 discrepancies, 108 were ‘failures to make a required change’ (77%) and 32 were ‘changes where none were required’ (23%). The types of ‘failures to make required changes’ discrepancies that were found between the initial TTA and pharmacist's amendments were paracetamol and ibuprofen changes (dose banding) 38 (27%), directions of use 34 (24%), incorrect formulation of medication 28 (20%) and incorrect strength 8 (6%). The types of ‘changes where none were required discrepancies’ were omitted medication 15 (11%), unnecessary drug 14 (10%) and incorrect medicine including spelling mistakes 3 (2%). After contacting the GPs of the discharged patients 72 h postdischarge; 49% had received the discharge summary and 45% had not, the remaining 6% were patients who were discharged without a GP. Conclusion: This study shows that doctor prescribing at discharge is often not accurate, and interventions made by pharmacist to reconcile are important at this point of care. It was also found that half the discharge summaries had not reached the patient's family physician (according to the GP) within 72 h.