6 resultados para Electromyographic
em Aston University Research Archive
Resumo:
Whole Body Vibrations consist of a vibration stimulus mechanically transferred to the body. The impact of vibration treatment on specific muscular activity, neuromuscular, and postural control has been widely studied. We investigated whole body vibration (WBV) effect on oxygen uptake and electromyographic signal of the rectus femoris muscle during static and dynamic squat. Fourteen healthy subjects performed a static and dynamic squat with and without vibration. During the vibration exercises, a significant increase was found in oxygen uptake (P=0.05), which increased by 44% during the static squat and 29.4% during the dynamic squat. Vibration increased heart rate by 11.1 ± 9.1 beats.min-1 during the static squat and 7.9 ± 8.3 beats.min-1 during the dynamic squat. No significant changes were observed in rate of perceived exertion between the exercises with and without vibration. The results indicate that the static squat with WBV produced higher neuromuscular and cardiorespiratory system activation for exercise duration ?60 sec. Otherwise, if the single bout duration was higher than 60 sec, the greater cardiorespiratory system activation was achieved during the dynamic squat with WBV while higher neuromuscular activation was still obtained with the static exercise.
Resumo:
This paper explores a new method of analysing muscle fatigue within the muscles predominantly used during microsurgery. The captured electromyographic (EMG) data retrieved from these muscles are analysed for any defining patterns relating to muscle fatigue. The analysis consists of dynamically embedding the EMG signals from a single muscle channel into an embedded matrix. The muscle fatigue is determined by defining its entropy characterized by the singular values of the dynamically embedded (DE) matrix. The paper compares this new method with the traditional method of using mean frequency shifts in the EMG signal's power spectral density. Linear regressions are fitted to the results from both methods, and the coefficients of variation of both their slope and point of intercept are determined. It is shown that the complexity method is slightly more robust in that the coefficient of variation for the DE method has lower variability than the conventional method of mean frequency analysis.
Resumo:
Studies using transcranial magnetic stimulation have demonstrated that action observation can modulate the activity of the corticospinal system. This has been attributed to the activity of an 'action observation network', whereby premotor cortex activity influences corticospinal excitability. Neuroimaging studies have demonstrated that the context in which participants observe actions (i.e. whether they simply attend to an action, or observe it with the intention to imitate) modulates action observation network activity. The study presented here examined whether the context in which actions were observed revealed similar modulatory effects on corticospinal excitability. Eight human participants observed a baseline stimulus (a fixation cross), observed actions in order to attend to them, or observed the same actions with the intention to imitate them. Whereas motor evoked potentials elicited from the first dorsal interosseus muscle of the hand were facilitated by attending to actions, observing the same actions in an imitative capacity led to no facilitation effect. Furthermore, no motor facilitation effects occurred in a control muscle. Electromyographic data collected when participants physically imitated the observed actions revealed that the activity of the first dorsal interosseus muscle increased significantly during action execution compared with rest. These data suggest that an inhibitory mechanism acts on the corticospinal system to prevent the immediate overt imitation of observed actions. These data provide novel insight into the properties of the human action observation network, demonstrating for the first time that observing actions with the intention to imitate them can modulate the effects of action observation on corticospinal excitability.
Resumo:
The impact of whole body vibrations (vibration stimulus mechanically transferred to the body) on muscular activity and neuromuscular response has been widely studied but without standard protocol and by using different kinds of exercises and parameters. In this study, we investigated how whole body vibration treatments affect electromyographic signal of rectus femoris during static and dynamic squat exercises. The aim was the identification of squat exercise characteristics useful to maximize neuromuscular activation and hence progress in training efficacy. Fourteen healthy volunteers performed both static and dynamic squat exercises without and with vibration treatments. Surface electromyographic signals of rectus femoris were recorded during the whole exercise and processed to reduce artifacts and to extract root mean square values. Paired t-test results demonstrated an increase of the root mean square values (p<0.05) in both static and dynamic squat exercises with vibrations respectively of 63% and 108%. For each exercise, subjects gave a rating of the perceived exertion according to the Borg's scale but there were no significant changes in the perceived exertion rate between exercises with and without vibration. Finally, results from analysis of electromyographic signals identified the static squat with WBV treatment as the exercise with higher neuromuscular system response. © 2012 IEEE.
Resumo:
Long term recording of biomedical signals such as ECG, EMG, respiration and other information (e.g. body motion) can improve diagnosis and potentially monitor the evolution of many widespread diseases. However, long term monitoring requires specific solutions, portable and wearable equipment that should be particularly comfortable for patients. The key-issues of portable biomedical instrumentation are: power consumption, long-term sensor stability, comfortable wearing and wireless connectivity. In this scenario, it would be valuable to realize prototypes using available technologies to assess long-term personal monitoring and foster new ways to provide healthcare services. The aim of this work is to discuss the advantages and the drawbacks in long term monitoring of biopotentials and body movements using textile electrodes embedded in clothes. The textile electrodes were embedded into garments; tiny shirt and short were used to acquire electrocardiographic and electromyographic signals. The garment was equipped with low power electronics for signal acquisition and data wireless transmission via Bluetooth. A small, battery powered, biopotential amplifier and three-axes acceleration body monitor was realized. Patient monitor incorporates a microcontroller, analog-to-digital signal conversion at programmable sampling frequencies. The system was able to acquire and to transmit real-time signals, within 10 m range, to any Bluetooth device (including PDA or cellular phone). The electronics were embedded in the shirt resulting comfortable to wear for patients. Small size MEMS 3-axes accelerometers were also integrated. © 2011 IEEE.
Resumo:
The aim of this study is to highlight the relationship between muscle motion, generated by whole body vibration, and the correspondent electromyographic (EMG) activity and to suggest a new method to customize the stimulation frequency. Simultaneous recordings of EMG and tri-axial accelerations of quadriceps rectus femoris from fifteen subjects undergoing vibration treatments were collected. Vibrations were delivered via a sinusoidal oscillating platform at different frequencies (10-45 Hz). Muscle motion was estimated by processing the accelerometer data. Large EMG motion artifacts were removed using sharp notch filters centred at the vibration frequency and its superior harmonics. EMG-RMS values were computed and analyzed before and after artifact suppression to assess muscular activity. Muscles acceleration amplitude increased with frequency. Muscle displacements revealed a mechanical resonant-like behaviour of the muscle. Resonance frequencies and dumping factors depended on subject. Moreover, RMS of artifact-free EMG was found well correlated (R 2 = 0.82) to the actual muscle displacement, while the maximum of the EMG response was found related to the mechanical resonance frequency of muscle. Results showed that maximum muscular activity was found in correspondence to the mechanical resonance of the muscle itself. Assuming the hypothesis that muscle activation is proportional to muscle displacement, treatment optimization (i.e. to choose the best stimulation frequency) could be obtained by simply monitoring local acceleration (resonance), leading to a more effective muscle stimulation. Motion artifact produced an overestimation of muscle activity, therefore its removal was essential. © 2009 IPEM.