12 resultados para Electrodes, Implanted

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: It is investigated to which extent measures of nonlinearity derived from surrogate data analysis are capable to quantify the changes of epileptic activity related to varying vigilance levels. Methods: Surface and intracranial EEG from foramen ovale (FO-)electrodes was recorded from a patient with temporal lobe epilepsy under presurgical evaluation over one night. Different measures of nonlinearity were estimated for non-overlapping 30-s segments for selected channels from surface and intracranial EEG. Additionally spectral measures were calculated. Sleep stages were scored according to Rechtschaffen/Kales and epileptic transients were counted and classified by visual inspection. Results: In the intracranial recordings stronger nonlinearity was found ipsilateral to the epileptogenic focus, more pronounced in NREM sleep, weaker in REM sleep. The dynamics within the NREM episodes varied with the different nonlinearity measures. Some nonlinearity measures showed variations with the sleep cycle also in the intracranial recordings contralateral to the epileptic focus and in the surface EEG. It is shown that the nonlinearity is correlated with short-term fluctuations of the delta power. The higher frequency of occurrence of clinical relevant epileptic spikes in the first NREM episode was not clearly reflected in the nonlinearity measures. Conclusions: It was confirmed that epileptic activity renders the EEG nonlinear. However, it was shown that the sleep dynamics itself also effects the nonlinearity measures. Therefore, at the present stage it is not possible to establish a unique connection between the studied nonlinearity measures and specific types of epileptic activity in sleep EEG recordings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent animal studies highlighting the relationship between functional imaging signals and the underlying neuronal activity have revealed the potential capabilities of non-invasive methods. However, the valuable exchange of information between animal and human studies remains restricted by the limited evidence of direct physiological links between species. In this study we used magnetoencephalography (MEG) to investigate the occurrence of 30-70 Hz (gamma) oscillations in human visual cortex, induced by the presentation of visual stimuli of varying contrast. These oscillations, well described in the animal literature, were observed in retinotopically concordant locations of visual cortex and show striking similarity to those found in primate visual cortex using surgically implanted electrodes. The amplitude of the gamma oscillations increases linearly with stimulus contrast in strong correlation with the gamma oscillations found in the local field potential (LFP) of the macaque. We demonstrate that non-invasive magnetic field measurements of gamma oscillations in human visual cortex concur with invasive measures of activation in primate visual cortex, suggesting both a direct representation of underlying neuronal activity and a concurrence between human and primate cortical activity. © 2005 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

News & Comment. Many influential models of prefrontal cortex function suggest that activity within this area is often associated with additional activity in posterior regions of the cortex that support perception. The purpose of this cortical ‘coupling’ is to ensure that a perceptual representation is generated and then maintained within the working memory system. Areas in the right ventrolateral prefrontal cortex (vlPFC) and the fusiform gyrus have been implicated as associate areas involved in face processing. In an interesting case study by Vignal, Chauvel and Halgren the functional relationship between these two areas was tested1. In order to confirm the epileptogenic foci prior to resective surgery in a 30-year-old male patient, depth electrodes were implanted into sites around prefrontal, anterior temporal and premotor cortices. While the patient was looking at a blank screen, 50-Hz electrical stimulation of two probes implanted into the right anterior frontal gyrus resulted in the patient’s reporting the perception of a series of colourful faces. These facial hallucinations were described as being ‘…like passing slides, one after the after, linked together’. When asked to look at an actual face during stimulation at the same sites the patient reported transformation of that face (such as appearing without spectacles or with a hat). These findings were related to activity of a cortical network involving the vlPFC and the fusiform gyrus. This paper thus suggests a role in face processing for the vlPFC, evoking working memory processes to maintain facial representations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate that a controllable cracking can be realized in Si with a buried strain layer when hydrogen is introduced using traditional H-ion implantation techniques. However, H stimulated cracking is dependent on H projected ranges; cracking occurs along a Si0.8Ge0.2 strain layer only if the H projected range is shallower than the depth of the strained layer. The absence of cracking for H ranges deeper than the strain layer is attributed to ion-irradiation induced strain relaxation, which is confirmed by Rutherford-backscattering-spectrometry channeling angular scans. The study reveals the importance of strain in initializing continuous cracking with extremely low H concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vibration treatment by oscillating platforms is more and more employed in the fields of exercise physiology and bone research. The rationale of this treatment is based on the neuromuscular system response elicited by vibration loads. surface Electromyography (EMG) is largely utilized to assess muscular response elicited by vibrations and Root Mean Square of the electromyography signals is often used as a concise quantitative index of muscle activity; in general, EMG envelope or RMS is expected to increase during vibration. However, it is well known that during surface bio-potential recording, motion artifacts may arise from relative motion between electrodes and skin and between skin layers. Also the only skin stretch, modifying the internal charge distribution, results in a variation of electrode potential. The aim of this study is to highlight the movements of muscles, and the succeeding relevance of motion artifacts on electrodes, in subjects undergoing vibration treatments. EMGs from quadriceps of fifteen subjects were recorded during vibration at different frequencies (15-40 Hz); Triaxial accelerometers were placed onto quadriceps, as close as possible to muscle belly, to monitor motion. The computed muscle belly displacements showed a peculiar behavior reflecting the mechanical properties of the structures involved. Motion artifact related to the impressed vibration have been recognized and related to movement of the soft tissues. In fact large artifacts are visible on EMGs and patellar electrodes recordings during vibration. Signals spectra also revealed sharp peaks corresponding to vibration frequency and its harmonics, in accordance with accelerometers data. © 2008 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A porous composite formed of hollow graphene spheres with opens in them and amorphous carbon containing nitrogen and oxygenated groups has been fabricated by annealing the mixture of nanodiamond and polyacrylonitrile (PAN). Electrochemical tests on the electrode made of this material show that it may be a promising electrode material for supercapacitors. The relatively high capacitance is mainly attributed to the small inner electrical resistance, the huge specific surface area and the remaining nitrogen and oxygenated groups from the PAN.