5 resultados para Electricity-consumption
em Aston University Research Archive
Resumo:
Various micro-radial compressor configurations were investigated using one-dimensional meanline and computational fluid dynamics (CFD) techniques for use in a micro gas turbine (MGT) domestic combined heat and power (DCHP) application. Blade backsweep, shaft speed, and blade height were varied at a constant pressure ratio. Shaft speeds were limited to 220 000 r/min, to enable the use of a turbocharger bearing platform. Off-design compressor performance was established and used to determine the MGT performance envelope; this in turn was used to assess potential cost and environmental savings in a heat-led DCHP operating scenario within the target market of a detached family home. A low target-stage pressure ratio provided an opportunity to reduce diffusion within the impeller. Critically for DCHP, this produced very regular flow, which improved impeller performance for a wider operating envelope. The best performing impeller was a low-speed, 170 000 r/min, low-backsweep, 15° configuration producing 71.76 per cent stage efficiency at a pressure ratio of 2.20. This produced an MGT design point system efficiency of 14.85 per cent at 993 W, matching prime movers in the latest commercial DCHP units. Cost and CO2 savings were 10.7 per cent and 6.3 per cent, respectively, for annual power demands of 17.4 MWht and 6.1 MWhe compared to a standard condensing boiler (with grid) installation. The maximum cost saving (on design point) was 14.2 per cent for annual power demands of 22.62 MWht and 6.1 MWhe corresponding to an 8.1 per cent CO2 saving. When sizing, maximum savings were found with larger heat demands. When sized, maximum savings could be made by encouraging more electricity export either by reducing household electricity consumption or by increasing machine efficiency.
Resumo:
Shropshire Energy Team initiated this study to examine consumption and associated emissions in the predominantly rural county of Shropshire. Current use of energy is not sustainable in the long term and there are various approaches to dealing with the environmental problems it creates. Energy planning by a local authority for a sustainable future requires detailed energy consumption and environmental information. This information would enable target setting and the implementation of policies designed to encourage energy efficiency improvements and exploitation of renewable energy resources. This could aid regeneration strategies by providing new employment opportunities. Associated reductions in carbon dioxide and other emissions would help to meet national and international environmental targets. In the absence of this detailed information, the objective was to develop a methodology to assess energy consumption and emissions on a regional basis from 1990 onwards for all local planning authorities. This would enable a more accurate assessment of the relevant issues, such that plans are more appropriate and longer lasting. A first comprehensive set of data has been gathered from a wide range of sources and a strong correlation was found between population and energy consumption for a variety of regions across the UK. In this case the methodology was applied to the county of Shropshire to give, for the first time, estimates of primary fuel consumption, electricity consumption and associated emissions in Shropshire for 1990 to 2025. The estimates provide a suitable baseline for assessing the potential contribution renewable energy could play in meeting electricity demand in the country and in reducing emissions. The assessment indicated that in 1990 total primary fuel consumption was 63,518,018 GJ/y increasing to 119,956,465 GJ/y by 2025. This is associated with emissions of 1,129,626 t/y of carbon in 1990 rising to 1,303,282 t/y by 2025. In 1990, 22,565,713 GJ/y of the primary fuel consumption was used for generating electricity rising to 23,478,050 GJ/y in 2025. If targets to reduce primary fuel consumption are reached, then emissions of carbon would fall to 1,042,626 by 2025, if renewable energy targets were also reached then emissions of carbon would fall to 988,638 t/y by 2025.
Resumo:
A number of papers and reports covering the techno-economic analysis of bio-oil production has been published. These have had different scopes, use different feedstocks and reflected national cost structures. This paper reviews and compares their cost estimates and the experimental results that underpin them. A comprehensive cost and performance model was produced based on consensus data from the previous studies or stated scenarios where data is not available that reflected UK costs. The model takes account sales of bio-char that is a co-product of pyrolysis and the electricity consumption of the pyrolysis plant and biomass pre-processing plants. It was concluded that it should be able to produce bio-oil in the UK from energy crops for a similar cost as distillate fuel oil. It was also found that there was little difference in the processing cost for woodchips and baled miscanthus. © 2011 Elsevier Ltd.
Resumo:
This study proposes a new type of greenhouse for water re-use and energy saving for agriculture in arid and semi-arid inland regions affected by groundwater salinity. It combines desalination using reverse osmosis (RO), re-use of saline concentrate rejected by RO for cooling, and rainwater harvesting. Experimental work was carried at GBPUAT, Pantnagar, India. Saline concentrate was fed to evaporative cooling pads of greenhouse and found to evaporate at similar rates as conventional freshwater. Two enhancements to the system are described: i) A jet pump, designed and tested to use pressurized reject stream to re-circulate cooling water and thus maintain uniform wetness in cooling pads, was found capable of multiplying flow of cooling water by a factor of 2.5 to 4 while lifting water to a head of 1.55 m; and ii) Use of solar power to drive ventilation fans of greenhouse, for which an electronic circuit has been produced that uses maximum power-point tracking to maximize energy efficiency. Re-use of RO rejected concentrate for cooling saves water (6 l d-1 m-2) of greenhouse floor area and the improved fan could reduce electricity consumption by a factor 8.
Resumo:
The work presented in this thesis concerns itself with the application of Demand Side Management (DSM) by industrial subsector as applied to the UK electricity industry. A review of the origins of DSM in the US and the relevance of experience gained to the UK electricity industry is made. Reviews are also made of the current status of the UK electricity industry, the regulatory system, and the potential role of DSM within the prevalent industry environment. A financial appraisal of DSM in respect of the distribution business of a Regional Electricity Company (REC) is also made. This financial appraisal highlights the economic viability of DSM within the context of the current UK electricity industry. The background of the work presented above is then followed by the construction of a framework detailing the necessary requirements for expanding the commercial role of DSM to encompass benefits for the supply business of a REC. The derived framework is then applied, in part, to the UK ceramics manufacturing industry, and in full to the UK sanitaryware manufacturing industry. The application of the framework to the UK sanitaryware manufacturing industry has required the undertaking of a unique first-order energy audit of every such manufacturing site in the UK. As such the audit has revealed previously unknown data on the timings and magnitude of electricity demand and consumption attributable to end-use manufacturing technologies and processes. The audit also served to reveal the disparity in the attitudes toward energy services, and thus by implication towards DSM, of manufacturers within the same Standard Industrial Classification (SIC) code. In response to this, attempt is made to identify the underlying drivers which could cause this variation in attitude. A novel approach to the market segmentation of the companies within the UK ceramics manufacturing sector has been utilised to classify these companies in terms of their likelihood to participate in DSM programmes through the derived Energy Services approach. The market segmentation technique, although requiring further development to progress from a research based concept, highlights the necessity to look beyond the purely energy based needs of manufacturing industries when considering the utilisation of the Energy Services approach to facilitate DSM programs.