9 resultados para Edge effect control
em Aston University Research Archive
Resumo:
A multi-scale model of edge coding based on normalized Gaussian derivative filters successfully predicts perceived scale (blur) for a wide variety of edge profiles [Georgeson, M. A., May, K. A., Freeman, T. C. A., & Hesse, G. S. (in press). From filters to features: Scale-space analysis of edge and blur coding in human vision. Journal of Vision]. Our model spatially differentiates the luminance profile, half-wave rectifies the 1st derivative, and then differentiates twice more, to give the 3rd derivative of all regions with a positive gradient. This process is implemented by a set of Gaussian derivative filters with a range of scales. Peaks in the inverted normalized 3rd derivative across space and scale indicate the positions and scales of the edges. The edge contrast can be estimated from the height of the peak. The model provides a veridical estimate of the scale and contrast of edges that have a Gaussian integral profile. Therefore, since scale and contrast are independent stimulus parameters, the model predicts that the perceived value of either of these parameters should be unaffected by changes in the other. This prediction was found to be incorrect: reducing the contrast of an edge made it look sharper, and increasing its scale led to a decrease in the perceived contrast. Our model can account for these effects when the simple half-wave rectifier after the 1st derivative is replaced by a smoothed threshold function described by two parameters. For each subject, one pair of parameters provided a satisfactory fit to the data from all the experiments presented here and in the accompanying paper [May, K. A. & Georgeson, M. A. (2007). Added luminance ramp alters perceived edge blur and contrast: A critical test for derivative-based models of edge coding. Vision Research, 47, 1721-1731]. Thus, when we allow for the visual system's insensitivity to very shallow luminance gradients, our multi-scale model can be extended to edge coding over a wide range of contrasts and blurs. © 2007 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: Pharmacological intervention with peripheral sympathetic transmission at ciliary smooth muscle neuro-receptor junctions has been used against a background of controlled parasympathetic activity to investigate the characteristics of autonomic control of ocular accommodation. Methods: A continuously recording infrared optometer was used to measure accommodation on a group of five visually normal emmetropic subjects under open- and closed-loop conditions. A double-blind protocol between saline, timolol and betaxolol was used to differentiate between the localised action on ciliary smooth muscle and effects induced by changes in stimulus conditions. Data were collected before and 45 min following the instillation of saline, timolol or betaxolol. Open-loop post-task decay was investigated following 3 min sustained near fixation of a stimulus placed 3 D above the subject's pre-task tonic accommodation level. Closed-loop dynamic responses were recorded for each treatment condition while subjects viewed sinusoidally (0.05-0.6 Hz) or stepwise vergence-modulated targets over a 2 D range (2-4 D). Results: Open-loop data demonstrate a rapid post-task regression to pre-task tonic accommodation levels for saline and betaxolol control conditions. A slow positive post-task shift was induced by timolol indicating that sympathetic inhibition contributes to accommodative adaptation during sustained near vision. Closed-loop accommodation responses to temporally modulated sinusoidal stimuli showed characteristic features for both saline and betaxolol control conditions. Timolol induced a reduced gain for low- and mid-temporal frequencies (< 0.3 Hz) but did not affect the response at higher temporal frequencies. Response times to stepwise stimuli increased following the instillation of timolol for the near-to-far fixation condition compared with the controls and was related to the period of sustained prior fixation. Conclusions: Modulation of accommodation under open- and closed-loop conditions by a non-selective β-blocker is consistent with the temporal and inhibitory features of sympathetic innervation to ciliary smooth muscle. Although parasympathetic innervation predominates there is evidence to support a role for sympathetic innervation in the control of ocular accommodation. © 2002 The College of Optometrists.
Resumo:
The authors use social control theory to develop a conceptual model that addresses the effectiveness of regulatory agencies’ (e.g., Food and Drug Administration, Occupational Safety and Health Administration) field-level efforts to obtain conformance with product safety laws. Central to the model are the control processes agencies use when monitoring organizations and enforcing the safety rules. These approaches can be labeled formal control (e.g., rigid enforcement) and informal control (e.g., social instruction). The theoretical framework identifies an important antecedent of control and the relative effectiveness of control’s alternative forms in gaining compliance and reducing opportunism. Furthermore, the model predicts that the regulated firms’ level of agreement with the safety rules moderates the relationships between control and firm responses. A local health department’s administration of state food safety regulations provides the empirical context for testing the hypotheses. The results from a survey of 173 restaurants largely support the proposed model. The study findings inform a discussion of effective methods of administering product safety laws. The authors use social control theory to develop a conceptual model that addresses the effectiveness of regulatory agencies’ (e.g., Food and Drug Administration, Occupational Safety and Health Administration) field-level efforts to obtain conformance with product safety laws. Central to the model are the control processes agencies use when monitoring organizations and enforcing the safety rules. These approaches can be labeled formal control (e.g., rigid enforcement) and informal control (e.g., social instruction). The theoretical framework identifies an important antecedent of control and the relative effectiveness of control’s alternative forms in gaining compliance and reducing opportunism. Furthermore, the model predicts that the regulated firms’ level of agreement with the safety rules moderates the relationships between control and firm responses. A local health department’s administration of state food safety regulations provides the empirical context for testing the hypotheses. The results from a survey of 173 restaurants largely support the proposed model. The study findings inform a discussion of effective methods of administering product safety laws.
Resumo:
Investigations of relationships between the specific personality variable, locus of control (LOC, Rotter, 1966) and driver behaviour or accidents have returned contrasting results. Review suggests dependence on gender or experience characteristics of participants, suggesting these factors interact with LOC to influence driving. Relationships were investigated in terms of influence on the eight driving styles of the Multidimensional Driving Style Inventory (MDSI, Taubman-Ben-Ari, Mikulincer & Gillarth, 2004) in young drivers (18-29 years). Gender and LOC differences in driving styles previously related to accidents were proposed. It was also proposed that driving experience influences driving style, and LOC influences effect of driving experience. Gender differences were found for dissociative, anxious, patient, risky, angry and high velocity styles. Women had more external LOC than men, and driver stress styles increased with more external LOC, but reduced with increased driving experience, but so did patient style. High velocity style increased with experience. Controlling for LOC revealed important gender differences in effect of experience: positive effects for men (reducing angry and high velocity, increasing carefulness) and negative effects for women (increasing angry and higher velocity, reducing carefulness). Findings suggest negative influence of high internal LOC on young men in terms of its interaction with experience.
Resumo:
Correction of hyperglycaemia and prevention of glucotoxicity are important objectives in the management of type 2 diabetes. Dapagliflozin, a selective sodium-glucose cotransporter-2 inhibitor, reduces renal glucose reabsorption in an insulin-independent manner. We assessed the efficacy and safety of dapagliflozin in patients who have inadequate glycaemic control with metformin.
Resumo:
A re-examination of fundamental concepts and a formal structuring of the waveform analysis problem is presented in Part I. eg. the nature of frequency is examined and a novel alternative to the classical methods of detection proposed and implemented which has the advantage of speed and independence from amplitude. Waveform analysis provides the link between Parts I and II. Part II is devoted to Human Factors and the Adaptive Task Technique. The Historical, Technical and Intellectual development of the technique is traced in a review which examines the evidence of its advantages relative to non-adaptive fixed task methods of training, skill assessment and man-machine optimisation. A second review examines research evidence on the effect of vibration on manual control ability. Findings are presented in terms of percentage increment or decrement in performance relative to performance without vibration in the range 0-0.6Rms'g'. Primary task performance was found to vary by as much as 90% between tasks at the same Rms'g'. Differences in task difficulty accounted for this difference. Within tasks vibration-added-difficulty accounted for the effects of vibration intensity. Secondary tasks were found to be largely insensitive to vibration except secondaries which involved fine manual adjustment of minor controls. Three experiments are reported next in which an adaptive technique was used to measure the % task difficulty added by vertical random and sinusoidal vibration to a 'Critical Compensatory Tracking task. At vibration intensities between 0 - 0.09 Rms 'g' it was found that random vibration added (24.5 x Rms'g')/7.4 x 100% to the difficulty of the control task. An equivalence relationship between Random and Sinusoidal vibration effects was established based upon added task difficulty. Waveform Analyses which were applied to the experimental data served to validate Phase Plane analysis and uncovered the development of a control and possibly a vibration isolation strategy. The submission ends with an appraisal of subjects mentioned in the thesis title.
Resumo:
This research investigates specific ash control methods to limit inorganic content within biomass prior to fast pyrolysis and effect of specific ash components on fast pyrolysis processing, mass balance yields and bio-oil quality and stability. Inorganic content in miscanthus was naturally reduced over the winter period from June (7.36 wt. %) to February (2.80 wt. %) due to a combination of senescence and natural leaching from rain water. September harvest produced similar mass balance yields, bio-oil quality and stability compared to February harvest (conventional harvest), but nitrogen content in above ground crop was to high (208 kg ha.-1) to maintain sustainable crop production. Deionised water, 1.00% HCl and 0.10% Triton X-100 washes were used to reduce inorganic content of miscanthus. Miscanthus washed with 0.10% Triton X-100 resulted in the highest total liquid yield (76.21 wt. %) and lowest char and reaction water yields (9.77 wt. % and 8.25 wt. % respectively). Concentrations of Triton X-100 were varied to study further effects on mass balance yields and bio-oil stability. All concentrations of Triton X-100 increased total liquid yield and decreased char and reaction water yields compared to untreated miscanthus. In terms of bio-oil stability 1.00% Triton X-100 produced the most stable bio-oil with lowest viscosity index (2.43) and lowest water content index (1.01). Beech wood was impregnated with potassium and phosphorus resulting in lower liquid yields and increased char and gas yields due to their catalytic effect on fast pyrolysis product distribution. Increased potassium and phosphorus concentrations produced less stable bio-oils with viscosity and water content indexes increasing. Fast pyrolysis processing of phosphorus impregnated beech wood was problematic as the reactor bed material agglomerated into large clumps due to char formation within the reactor, affecting fluidisation and heat transfer.
Resumo:
Background: The Melbourne Edge Test (MET) is a portable forced-choice edge detection contrast sensitivity (CS) test. The original externally illuminated paper test has been superseded by a backlit version. The aim of this study was to establish normative values for age and to assess change with visual impairment. Method: The MET was administered to 168 people with normal vision (18-93 years old) and 93 patients with visual impairment (39-97 years old). Distance visual acuity (VA) was measured with a log MAR chart. Results: In those eyes without disease, MET CS was stable until the age of 50 years (23.8 ± .7 dB) after which it decreased at a rate of ≈1.5 dB per decade. Compared with normative values, people with low vision were found to have significantly reduced CS, which could not be totally accounted for by reduced VA. Conclusions: The MET provides a quick and easy measure of CS, which highlights a reduction in visual function that may not be detectable using VA measurements. © 2004 The College of Optometrists.
Resumo:
Over the last decade, there has been a trend where water utility companies aim to make water distribution networks more intelligent in order to improve their quality of service, reduce water waste, minimize maintenance costs etc., by incorporating IoT technologies. Current state of the art solutions use expensive power hungry deployments to monitor and transmit water network states periodically in order to detect anomalous behaviors such as water leakage and bursts. However, more than 97% of water network assets are remote away from power and are often in geographically remote underpopulated areas, facts that make current approaches unsuitable for next generation more dynamic adaptive water networks. Battery-driven wireless sensor/actuator based solutions are theoretically the perfect choice to support next generation water distribution. In this paper, we present an end-to-end water leak localization system, which exploits edge processing and enables the use of battery-driven sensor nodes. Our system combines a lightweight edge anomaly detection algorithm based on compression rates and an efficient localization algorithm based on graph theory. The edge anomaly detection and localization elements of the systems produce a timely and accurate localization result and reduce the communication by 99% compared to the traditional periodic communication. We evaluated our schemes by deploying non-intrusive sensors measuring vibrational data on a real-world water test rig that have had controlled leakage and burst scenarios implemented.