3 resultados para Domestic Service

em Aston University Research Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Domestic violence is everywhere and nowhere. No statutory organization or health service has work with either perpetrators or survivors of domestic violence (usually women and children) as the primary focus of their service, yet all agencies will have very significant numbers among their clients/service users. It is therefore crucial that the policy framework is developed both within and between agencies to address the need, and scope, of intervention in this area and particularly the impact on children. Currently, significant steps have been taken by some agencies in the UK to address this previously neglected issue, though the developments are patchy. This paper draws on a UK-wide research study which mapped the extent and range of service provision for families where there is domestic violence and also developed a framework of good practice indicators for ‘Mapped the extent and range of service provision for families where there is domestic violence and also developed a framework of good practice indicators’ provision in this area. This article examines one of the indicators of good practice arising from the research—that of policy development—within social service departments and within the multi-agency arena.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents differences in firm-level total factor productivity (TFP) across 22 manufacturing and 17 service industries in Germany over the period 1995–2004. It is an attempt to study whether and to what extent foreign multinational enterprises (MNEs) are more productive relative to German firms. As well as distinguishing between foreign and domestic firms, we also distinguish between German MNEs and domestic firms that do not have any foreign presence. Controlling for endogeneity through semi-parametric techniques, our findings indicate considerable heterogeneity in firm performance across types of firms. The foreign/domestic distinction is not as clear cut as has been suggested elsewhere; multinationality is important in explaining productivity differences rather than foreignness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis records the design and development of an electrically driven, air to water, vapour compression heat pump of nominally 6kW heat output, for residential space heating. The study was carried out on behalf of GEC Research Ltd through the Interdisciplinary Higher Degrees Scheme at Aston University. A computer based mathematical model of the vapour compression cycle was produced as a design aid, to enable the effects of component design changes or variations in operating conditions to be predicted. This model is supported by performance testing of the major components, which revealed that improvements in the compressor isentropic efficiency offer the greatest potential for further increases in cycle COPh. The evaporator was designed from first principles, and is based on wire-wound heat transfer tubing. Two evaporators, of air side area 10.27 and 16.24m2, were tested in a temperature and humidity controlled environment, demonstrating that the benefits of the large coil are greater heat pump heat output and lower noise levels. A systematic study of frost growth rates suggested that this problem is most severe at the conditions of saturated air at 0oC combined with low condenser water temperature. A dynamic simulation model was developed to predict the in-service performance of the heat pump. This study confirmed the importance of an adequate radiator area for heat pump installations. A prototype heat pump was designed and manufactured, consisting of a hermetic reciprocating compressor, a coaxial tube condenser and a helically coiled evaporator, using Refrigerant 22. The prototype was field tested in a domestic environment for one and a half years. The installation included a comprehensive monitoring system. Initial problems were encountered with defrosting and compressor noise, both of which were solved. The unit then operated throughout the 1985/86 heating season without further attention, producing a COPh of 2.34.