17 resultados para Disinfection and disinfectants.

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Healthcare associated infections may arise from many sources, including patient?s own skin flora and the clinical environment, and inflict a significant burden within the health service. Adequate and effective skin antisepsis and surface disinfection are therefore essential factors in infection control. Current EPIC guidelines recommend 2 % chlorhexidine (CHG) in 70 % isopropyl alcohol (IPA) for skin antisepsis however poor penetration has been reported. Eucalyptus oil (EO) is a known permeation enhancer, producing synergistic antimicrobial activity when combined with CHG. In this current study, the antimicrobial efficacy of EO and its main constituent 1,8-cineole were assessed against a panel of clinically relevant microorganisms, alone and in combination with CHG. The superior antimicrobial efficacy of EO compared with 1,8-cineole, and synergistic effects with CHG against planktonic and biofilm cultures, confirmed its suitability for use in subsequent studies within this thesis. Impregnation of EO, CHG and IPA onto prototype hard surface disinfectant wipes demonstrated significantly improved efficacy compared with CHG/IPA wipes, with clear reductions in the time required to eliminate biofilms. Optimisation of the EO/CHG/IPA formulation resulted in the development of Euclean® wipes, with simulated-use and time kill studies confirming their ability to remove microbial surface contamination, prevent cross contamination and eliminate biofilms within 10 minutes. The employment of isothermal calorimetry provided additional information on the type and rate of antimicrobial activity possessed by Euclean® wipes. A clinical audit of the Euclean® wipes at Birmingham Children?s Hospital, Birmingham, U.K. revealed divided staff opinion, with the highest cited advantage and disadvantage concerning the odour. Finally, skin penetration and cell toxicity studies of EO/CHG biopatches and Euclean® solution developed during this study, revealed no permeation into human skin following biopatch application, and no significant toxicity. These current studies enhance the knowledge regarding EO and its potential applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bacterial resistance to antibiotics and biocides is a prevalent problem, which may be exacerbated by the commonplace and often unnecessary inclusion of biocides into domestic products. Addition of antimicrobials, to domestic disinfectants has raised concern about promoting microbial resistance and potential cross-resistance to therapeutic antibiotics. This study investigated the potential for resistance in Salmonella enterica serovars Enteritidis, Typhimurium, Virchow and Escherichia call 0157 to commonly used biocides, to identify mechanisms underlying resistance and whether these provided cross-resistance to antibiotics. Salmonella enterica and E. coli 0157 strains were serially exposed to sub-inhibitory. concentrations of erythromycin (ERY), benzalkonium chloride (BKC), chlorhexidine hydrochloride (CHX)and triclosan (TLN). Once resistance was achieved permeability changes in the outer membrane, including LPS, cell surface charge and hydrophobicityand the presence of,an active efflux were investigated as possible resistance candidates. Thin layer chromatography (TLC) and Gas chromatography (GC) were carried out to examine fatty acid and lipid changes in E. coli 0157 isolates with reduced susceptibility to TLN. Cross-resistance was studied by the Stoke's method and standard microdilution assays. Examination of the outer membrane proteins and LPS did not reveal any significant changes between parent and resistant strains. The hydrophobicity of the cells increased as the cells were passaged and became less. susceptible. An active efflux system was the most likely mechanism of resistance in all strains tested and a fab1 mutation was associated with E. coli 0157 resistant to TLN isolates. In all isolates investigated the resistance was stable for over 30 passages in biocide-free media. A high degree of cross-resistance was obtained in TLN-resjstant Escherichia coli 0157 strains, which repeatedly exerted decreased susceptibility to various antimicrobials, including chloramphenicol, erythromycin, imipenem, tetracycline and trimethoprirn:, as well as to various biocides. The results of this laboratory-based investigation suggest that it is possible for microorganisms to become resistant to biocides when repeatedly exposed to sublethal concentrations. This may be especially the case in the domestic environment where administration of biocides is poorly controlled. Eventually it could lead to the undesirable situation of resident strains becoming resistant to disinfection and cross resistant to other antimicrobials.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Central venous catheters have become an integral part of patient management however they are associated with many complications including infection. Despite efforts being made to reduce the incidence of such infect ions the problem continues to increase and has resource implications for the Health Service. Studies relating to the source of microorganisms causing CVC-associated infection, the cost of such infections and the efficacy of an antimicrobial catheter have been undertaken. Thirty patients who required a CVC as part of their medical management and underwent cardiac surgery had the distal tips of their catheters sampled whilst in situ. Sampling took place within 1 h of catheter placement. Bacteria were isolated from 16% of the catheter distal tips sampled in situ. The guidewires used to insert the devices were also contaminated (50%). When CVC were inserted via a protective sheath, avoiding contact with the skin. the incidence of microbial contamination was reduced. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted onto the distal tip of CVC during the insertion procedure. Needleless intravascular access devices have been introduced in order to reduce the incidence of need1estick injury. However, it was unclear whether such connectors would act as a portal of entry for microorganisms to CVC. The efficacy of these devices was investigated. Within the controlled laboratory environment it was demonstrated that needleless devices, when challenged with microorganisms, did not allow the passage of microbes when flu id was injected. This therefore suggested that the devices should not increase the risk of catheter colonisation. When used in clinical practice however microbial contamination of the needleless connectors was 55 % in comparison to the routinely used luer connectors (23%). The cost of infections associated with CVC was determined. Twenty patients catheterised with a CVC designed for long term use who were admitted to hospital with a presumptive diagnosis of catheter-related infection were studied. The treatment given specifically for this infection was costed. The mean cost of such an infection was £ 1781.81. Throughout the UK this may amount to £1.565.906 per annum. The cost of infections associated with CVC designed for short term use was estimated to be between 5 and 7 million pounds per annum in the UK. In an attempt to reduce both the incidence and cost of catheter- related infection antimicrobial CVC have been developed. The efficacy of a novel polyurethane CVC impregnated on both the internal and external catheter surface with the quaternary ammonium compound benzalkonium chloride was investigated. Eighty eight patients received an antimicrobial catheter and 78 patients a conventional polyurethane CVC. The anti-microbial CVC resulted in a reduction in microbial colonisation of the external and internal polymer surfaces as compared to the control device. The observed reduction in microbial colonisation with the anti-microbial CVC may decrease the likelihood of subsequent infection offering a useful approach to the prevention of catheter-related infections.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Staphylococcus epidermidis are common Gram-positive bacteria and are responsible for a number of life-threatening nosocomial infections. Treatment of S. epidermidis infection is problematic because the organism is usually resistant to many antibiotics. The high degree of resistance of this organism to a range of antibiotics and disinfectants is widely known. The aims of this thesis were to investigate and evaluate the susceptibility of isolates of S. epidermidis from various infections to chlorhexidine (CHX) and to other disinfectants such as benzalkonium chloride (BKC), triclosan (TLN) and povidone-iodine (PI). In addition, the mechanisms of resistance of S. epidermidis to chlorhexidine (the original isolates and strains adapted to chlorhexidine by serial passage) were examined and co-resistance to clinically relevant antibiotics investigated. In 3 of the 11 S. epidermidis strains passaged in increasing concentrations of chlorhexidine, resistance to the disinfectant arose (16-fold). These strains were examined further, each showing stable chlorhexidine resistance. Co-resistance to other disinfectants such as BKC, TLN and PI and changes in cell surface hydrophobicity were observed. Increases in resistance were accompanied by an increase in the proportion of neutral lipids and phospholipids in the cell membrane. This increase was most marked in diphosphatidylglycerol. These observations suggest that some strains of S. epidermidis can become resistant to chlorhexidine and related disinfectants/antiseptics by continual exposure. The mechanisms of resistance appear to be related to changes in membrane lipid compositions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Effective surface disinfection is a fundamental infection control strategy within healthcare. This study assessed the antimicrobial efficacy of novel biocide formulations comprising 5% and 2% eucalyptus oil (EO) combined with 2% chlorhexidine digluconate (CHG) and 70% isopropyl alcohol (IPA) contained within a wipe. The efficacy of this novel antimicrobial formulation to remove and eliminate methicillin-resistant Staphylococcus aureus (MRSA), Escherichia coli and Candida albicans from steel surfaces was investigated. Adpression studies of pre-contaminated wipes were also utilised to assess their potential to induce cross-contamination between hard surfaces. Furthermore, the bactericidal nature of the EO-formulation was established in addition to time-kill. The EO-containing formulations demonstrated bactericidal antimicrobial efficacy against all microorganisms and did not induce surface cross-contamination. There was no significant difference (p < 0.05) between the 5% and 2% EO formulations in their ability to remove microorganisms from steel surfaces, however both significantly (p < 0.05) removed more than the control formulations. Microbial biofilms were eliminated within 10 min (p < 0.05) when exposed to the EO formulations. Our novel EO-formulation demonstrated rapid antimicrobial efficacy for potential disinfection and elimination of microbial biofilms from hard surfaces and may therefore be a useful adjunct to current infection control strategies currently employed within healthcare facilities.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The sporicidal activity of an odour-free peracetic acid-based disinfectant (Wofasteril®) and a widely-used dichloroisocyanurate preparation (Chlor-clean®) was assessed against spores of the hyper-virulent strain of Clostridium difficile (ribotype 027), in the presence and absence of organic matter. In environmentally clean conditions, dichloroisocyanurate achieved a >3 log10 reduction in 3 minutes, but a minimum contact time of 9 minutes was required to reduce the viable spore load to below detection levels. Peracetic acid achieved a >3 log10 reduction in 30 minutes and was overall significantly less effective (P<0.05). However, in the presence of organic matter - which reflects the true clinical environment - there was no significant difference between the sporicidal activity of dichloroisocyanurate and peracetic acid over a 60-minute period (P=0.188). Given the greater occupational health hazards generally associated with chlorine-releasing agents, odour-free peracetic acid-based disinfectants may offer a suitable alternative for environmental disinfection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives Effective skin antisepsis and disinfection of medical devices are key factors in preventing many healthcare-acquired infections associated with skin microorganisms, particularly Staphylococcus epidermidis. The aim of this study was to investigate the antimicrobial efficacy of chlorhexidine digluconate (CHG), a widely used antiseptic in clinical practice, alone and in combination with tea tree oil (TTO), eucalyptus oil (EO) and thymol against planktonic and biofilm cultures of S. epidermidis. Methods Antimicrobial susceptibility assays against S. epidermidis in a suspension and in a biofilm mode of growth were performed with broth microdilution and ATP bioluminescence methods, respectively. Synergy of antimicrobial agents was evaluated with the chequerboard method. Results CHG exhibited antimicrobial activity against S. epidermidis in both suspension and biofilm (MIC 2–8 mg/L). Of the essential oils thymol exhibited the greatest antimicrobial efficacy (0.5–4 g/L) against S. epidermidis in suspension and biofilm followed by TTO (2–16 g/L) and EO (4–64 g/L). MICs of CHG and EO were reduced against S. epidermidis biofilm when in combination (MIC of 8 reduced to 0.25–1 mg/L and MIC of 32–64 reduced to 4 g/L for CHG and EO, respectively). Furthermore, the combination of EO with CHG demonstrated synergistic activity against S. epidermidis biofilm with a fractional inhibitory concentration index of <0.5. Conclusions The results from this study suggest that there may be a role for essential oils, in particular EO, for improved skin antisepsis when combined with CHG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis has sought to investigate disinfection agents and procedures which may provide sanitisation against bacterial spores. A hard-surface disinfection test method was designed to ascertain which combinations of biocide and application method were most effective against bacterial spores. A combination of spraying and wiping was the most effective method of disinfection against Bacillus spores, with wiping found to play a key role in spore removal. The most efficacious of the biocides investigated was the 6% hydrogen peroxide. Vaporised Hydrogen Peroxide (VHP) gassing was more effective than traditional disinfection. In addition to efficacy, the toxic potential of the biocides to human airway epithelial cells in vitro was evaluated. Toxicity against human bronchial and nasal epithelial cells was assessed by determining cell viability, inflammatory status, protein oxidation and epithelial cell layer integrity. In addition the cell death mechanism following biocide exposure was investigated. There was a decrease in viable cells following exposure to all biocides when applied at practical concentrations. Almost all of the biocides tested elicited a pro-inflammatory response from the cells as measured by IL-8 production. All biocides increased protein oxidation as measured by thiol and carbonyl levels. Measurement of transepithelial electrical resistance and paracellular permeability indicated biocide-dependent decrease in epithelial cell barrier function. The cellular response was biased towards necrotic rather than apoptotic death. The use of biocides, although efficacious to some effects against Bacillus spores, will require careful monitoring for adverse health effects on personnel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current practice in National Health Service (NHS) hospitals employs 70% Industrial Methylated Spirit spray for surface disinfection of components required in Grade A pharmaceutical environments. This study seeks to investigate other agents and procedures that may provide more effective sanitisation. Several methods are available to test the efficacy of disinfectants against vegetative organisms. However, no methods currently available test the efficacy of disinfectants against spores on the hard surfaces encountered in the pharmacy aseptic processing environment. Therefore, a method has been developed to test the efficacy of disinfectants against spores, modified from British Standard 13697 and Association of Analytical Chemists standards. The testing procedure was used to evaluate alternative biocides and disinfection methods for transferring components into hospital pharmacy cleanrooms, and to determine which combinations of biocide and application method have the greatest efficacy against spores of Bacillus subtilis subspecies subtilis 168, Bacillus subtilis American Type Culture Collection (ATCC) 6633, and Bacillus pumilis ATCC 27142. Stainless steel carrier test plates were used to represent the hard surfaces in hospital pharmacy cleanrooms. Plates were inoculated with 10(7)-10(8) colony-forming units per milliliter (CFU/mL) and treated with the various biocide formulations, using different disinfection methods. Sporicidal activity was calculated as log reduction in CFU. Of the biocides tested, 6% hydrogen peroxide and a quaternary ammonium compound/chlorine dioxide combination were most effective compared to a Quat/biguanide, amphoteric surfactant, 70% v/v ethanol in deionised water and isopropyl alcohol in water for injection. Of the different application methods tested, spraying followed by wiping was the most effective, followed closely by wiping alone. Spraying alone was least effective.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sodium hypochlorite and sodium chlorite are commonly used as disinfectants, and understanding the mechanisms of microbial resistance to these compounds is of considerable importance. In this study, the role of oxidative stress and antioxidant enzymes in the sensitivity of the yeast Saccharomyces cerevisiae to hypochlorite and chlorite was studied. Yeast mutants lacking Cu-Zn superoxide dismutase, but not mutants deficient in cytoplasmic and peroxisomal catalase, were hypersensitive to the action of both hypochlorite and chlorite. Both compounds depleted cellular glutathione, induced the production of reactive oxygen species and decreased the viability of the cells. The toxicity of hypochlorite and chlorite was abolished by hypoxic and anoxic conditions and ameliorated by thiol antioxidants and ascorbate. The results demonstrated that the action of hypochlorite and chlorite involves the formation of superoxide and peroxide and that SOD1 is protective, probably by limiting the formation of hydroxyl radicals and damage to proteins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Soft contact lenses for continuous wear require the use of cleaning regimes which utilise hydrogen peroxide systems or multipurpose cleaning solutions (MPS). The compositions of MPS are becoming increasingly complex and often include disinfectants, cleaning agents, preservatives, wetting agents, demulcents, chelating and buffering agents. Recent research on solution–lens interactions has focused on specific ocular parameters such as corneal staining. However the effect of a solution on the lens, particularly silicone hydrogel lenses, itself has received less attention. The purpose of this work was to establish and understand the effects that care solutions have on selected bulk and surface material properties. Methods: Selected bulk and surface properties of each material (etafilcon A, vifilcon A, balafilcon A, senofilcon A, lotrafilcon A and lotrafilcon B, galyfilcon A) were measured after a 24 h soak in a variety of care solutions. Additionally the lenses were soaked for 24 h in hyperosmolar (680 mOsm L-1) and hyposmolar (170 mOsm L-1) PBS. A bulk property parameter the total diameter (TD) was measured using an Optimec contact lens analyser. The surface property related CoF of soaked lenses was measured on a nano-tribometer with conditions of load 30 mN, at a distance of 20 mm and speed 30 mm/min. Results: In terms of bulk properties, change is related to the EWC of the lens, the higher the EWC of the lens the greater the TD changes. Silicone hydrogel lenses have EWCs of <47% and little or no TD changes were observed; lotrafilcon A exhibited no change irrespective of the cleaning solution. Conventional contact lenses have higher EWCs (58% for etafilcon A and 55% for vifilcon A) and the TD was seen to change to a greater extent, for example the etafilcon A material in ReNu MPS had an increase to 14.45± 0.07 mm from the cited 14.2 mm. Other lenses increased or decreased in TD depending on the solution used. The osmolarity of the solution although important is not the only factor governing change in the TD, for example soaking senofilcon A in hyperosmolar PBS (680 mOsm L-1) for 24 h increased the TD of the lens (+0.25 ± 0.07 mm), however when the same lens type was soaked for 24 h in a MPS with a lower osmolarity there was a similar effect. Biotribology measurements demonstrated that some solution–lens combinations can reduce the CoF by 55%, when compared with biotribology with the native packing solution. An increase in the CoF was observed for other solution–lens combinations. Conclusions: There is a dramatic difference in bulk and surface performance of specific lens materials with particular care solutions. Individual components of the care solutions have effects on the bulk and surface properties of contact lenses. The affects are not as great with the silicone hydrogel as compared with conventional hydrogels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We undertook a clinical trial to compare the efficacy of 2% (w/v) chlorhexidine gluconate in 70% (v/v) isopropyl alcohol with the efficacy of 70% (v/v) isopropyl alcohol alone for skin disinfection to prevent peripheral venous catheter colonization and contamination. We found that the addition of 2% chlorhexidine gluconate reduced the number of peripheral venous catheters that were colonized or contaminated. © 2008 by The Society for Healthcare Epidemiology of America. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The microbial contamination rate of luers of central venous catheters (CVCs) with either PosiFlow® needleless connectors or standard caps attached was investigated. The efficacy of 70% (v/v) isopropyl alcohol, 0.5% (w/v) chlorhexidine in gluconate 70% (v/v) isopropyl alcohol and 10% (w/v) aqueous povidone-iodine to disinfect the intravenous connections was also assessed. Seventy-seven patients undergoing cardiac surgery who required a CVC as part of their clinical management were randomly allocated either needleless connectors or standard caps. Patients were also designated to receive chlorhexidine/alcohol, isopropyl alcohol or povidone-iodine for pre-CVC insertion skin preparation and disinfection of the connections. After 72 h in situ the microbial contamination rate of 580 luers, 306 with standard caps and 274 with needleless connectors attached, was determined. The microbial contamination rate of the external compression seals of 274 needleless connectors was also assessed to compare the efficacy of the three disinfectants. The internal surfaces of 55 out of 306 (18%) luers with standard caps were contaminated with micro-organisms, whilst only 18 out of 274 (6.6%) luers with needleless connectors were contaminated (P<0.0001). Of those needleless connectors disinfected with isopropyl alcohol, 69.2% were externally contaminated with micro-organisms compared with 30.8% disinfected with chlorhexidine/alcohol (P<0.0001) and 41.6% with povidone-iodine (P<0.0001). These results suggest that the use of needleless connectors may reduce the microbial contamination rate of CVC luers compared with the standard cap. Furthermore, disinfection of needleless connectors with either chlorhexidine/alcohol or povidone-iodine significantly reduced external microbial contamination. Both these strategies may reduce the risk of catheter-related infections acquired via the intraluminal route. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT