13 resultados para Direction of motion

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We sought to determine the extent to which red–green, colour–opponent mechanisms in the human visual system play a role in the perception of drifting luminance–modulated targets. Contrast sensitivity for the directional discrimination of drifting luminance–modulated (yellow–black) test sinusoids was measured following adaptation to isoluminant red–green sinusoids drifting in either the same or opposite direction. When the test and adapt stimuli drifted in the same direction, large sensitivity losses were evident at all test temporal frequencies employed (1–16 Hz). The magnitude of the loss was independent of temporal frequency. When adapt and test stimuli drifted in opposing directions, large sensitivity losses were evident at lower temporal frequencies (1–4 Hz) and declined with increasing temporal frequency. Control studies showed that this temporal–frequency–dependent effect could not reflect the activity of achromatic units. Our results provide evidence that chromatic mechanisms contribute to the perception of luminance–modulated motion targets drifting at speeds of up to at least 32°s-1. We argue that such mechanisms most probably lie within a parvocellular–dominated cortical visual pathway, sensitive to both chromatic and luminance modulation, but only weakly selective for the direction of stimulus motion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this paper is to demonstrate the existence of a strong and significant effect of complexity in aphasia independent from other variables including length. Complexity was found to be a strong and significant predictor of accurate repetition in a group of 13 Italian aphasic patients when it was entered in a regression equation either simultaneously or after a large number of other variables. Significant effects were found both when complexity was measured in terms of number of complex onsets (as in a recent paper by Nickels & Howard, 2004) and when it was measured in a more comprehensive way. Significant complexity effects were also found with matched lists contrasting simple and complex words and in analyses of errors. Effects of complexity, however, were restricted to patients with articulatory difficulties. Reasons for this association and for the lack of significant results in Nickels and Howard (2004) are discussed. © 2005 Psychology Press Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article seeks to add to the small but growing literature of emerging-market multinational enterprises (EMNEs). Using two linked large firm-level databases, it seeks to explore the determinants of outward investment of Indian pharmaceutical companies, distinguishing between developed- versus developing-country destinations. It specifically examines the impact of two firm-level characteristics that embody “non-OLI” [ownership, location, and internalization] firm-specific capabilities of EMNEs. The finding of this study is that family firms are keen on investing in other developing countries but much less so in developed countries. However, international linkages in the form of foreign investors offset this.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electromyography readings (EMGs) from quadriceps of fifteen subjects were recorded during whole body vibration treatment at different frequencies (10-50 Hz). Additional electrodes were placed on the patella to monitor the occurrence of motion artifact, triaxial accelerometers were placed onto quadriceps to monitor motion. Signal spectra revealed sharp peaks corresponding to vibration frequency and its harmonics, in accordance with the accelerometer data. EMG total power was compared to that associated with vibration harmonics narrow bands, before and during vibration. On average, vibration associated power resulted in only 3% (±0.9%) of the total power prior to vibration and 29% (±13.4%) during vibration. Often, studies employ surface EMG to quantitatively evaluate vibration evoked muscular activity and to set stimulation frequency. However, previous research has not accounted for motion artifacts. The data presented in this study emphasize the need for the removal of motion artifacts, as they consistently affect RMS estimation, which is often used as a concise muscle activity index during vibrations. Such artifacts, rather unpredictable in amplitude, might be the cause of large inter-study differences and must be eliminated before analysis. Motion artifact filtering will contribute to thorough and precise interpretation of neuromuscular response to vibration treatment. © 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When a visual stimulus is continuously moved behind a small stationary window, the window appears displaced in the direction of motion of the stimulus. In this study we showed that the magnitude of this illusion is dependent on (i) whether a perceptual or visuomotor task is used for judging the location of the window, (ii) the directional signature of the stimulus, and (iii) whether or not there is a significant delay between the end of the visual presentation and the initiation of the localization measure. Our stimulus was a drifting sinusoidal grating windowed in space by a stationary, two-dimensional, Gaussian envelope (σ=1 cycle of sinusoid). Localization measures were made following either a short (200 ms) or long (4.2 s) post-stimulus delay. The visuomotor localization error was up to three times greater than the perceptual error for a short delay. However, the visuomotor and perceptual localization measures were similar for a long delay. Our results provide evidence in support of the hypothesis that separate cortical pathways exist for visual perception and visually guided action and that delayed actions rely on stored perceptual information.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When viewing a drifting plaid stimulus, perceived motion alternates over time between coherent pattern motion and a transparent impression of the two component gratings. It is known that changing the intrinsic attributes of such patterns (e.g. speed, orientation and spatial frequency of components) can influence percept predominance. Here, we investigate the contribution of extrinsic factors to perception; specifically contextual motion and eye movements. In the first experiment, the percept most similar to the speed and direction of surround motion increased in dominance, implying a tuned integration process. This shift primarily involved an increase in dominance durations of the consistent percept. The second experiment measured eye movements under similar conditions. Saccades were not associated with perceptual transitions, though blink rate increased around the time of a switch. This indicates that saccades do not cause switches, yet saccades in a congruent direction might help to prolong a percept because i) more saccades were directionally congruent with the currently reported percept than expected by chance, and ii) when observers were asked to make deliberate eye movements along one motion axis, this increased percept reports in that direction. Overall, we find evidence that perception of bistable motion can be modulated by information from spatially adjacent regions, and changes to the retinal image caused by blinks and saccades.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blurred edges appear sharper in motion than when they are stationary. We proposed a model of this motion sharpening that invokes a local, nonlinear contrast transducer function (Hammett et al, 1998 Vision Research 38 2099-2108). Response saturation in the transducer compresses or 'clips' the input spatial waveform, rendering the edges as sharper. To explain the increasing distortion of drifting edges at higher speeds, the degree of nonlinearity must increase with speed or temporal frequency. A dynamic contrast gain control before the transducer can account for both the speed dependence and approximate contrast invariance of motion sharpening (Hammett et al, 2003 Vision Research, in press). We show here that this model also predicts perceived sharpening of briefly flashed and flickering edges, and we show that the model can account fairly well for experimental data from all three modes of presentation (motion, flash, and flicker). At moderate durations and lower temporal frequencies the gain control attenuates the input signal, thus protecting it from later compression by the transducer. The gain control is somewhat sluggish, and so it suffers both a slow onset, and loss of power at high temporal frequencies. Consequently, brief presentations and high temporal frequencies of drift and flicker are less protected from distortion, and show greater perceptual sharpening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study some common types of Rolling Bearing vibrations are analysed in depth both theoretically and experimentally. The study is restricted to vibrations in the radial direction of bearings having pure radial load and a positive radial clearance. The general vibrational behaviour of such bearings has been investigated with respect to the effects of varying compliance, manufacturing tolerances and the interaction between the bearing and the machine structure into which it is fitted. The equations of motion for a rotor supported by a bearing in which the stiffness varies with cage position has been set up and examples of solutions,obtained by digital simulation. is given. A method to calculate amplitudes and frequencies of vibration components due to out of roundness of the inner ring and varying roller diameters has been developed. The results from these investigations have been combined with a theory for bearing/machine frame interaction using mechanical impedance technique, thereby facilitating prediction of the vibrational behaviour of the whole set up. Finally. the effects of bearing fatigue and wear have been studied with particular emphasis on the use of vibration analysis for condition monitoring purposes. A number of monitoring methods have been tried and their effectiveness discussed. The experimental investigation was carried out using two purpose built rigs. For the purpose of analysis of the experimental measurements a digital mini computer was adapted for signal processing and a suite of programs was written. The program package performs several of the commonly used signal analysis processes and :include all necessary input and output functions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Product reliability and its environmental performance have become critical elements within a product's specification and design. To obtain a high level of confidence in the reliability of the design it is customary to test the design under realistic conditions in a laboratory. The objective of the work is to examine the feasibility of designing mechanical test rigs which exhibit prescribed dynamical characteristics. The design is then attached to the rig and excitation is applied to the rig, which then transmits representative vibration levels into the product. The philosophical considerations made at the outset of the project are discussed as they form the basis for the resulting design methodologies. It is attempted to directly identify the parameters of a test rig from the spatial model derived during the system identification process. It is shown to be impossible to identify a feasible test rig design using this technique. A finite dimensional optimal design methodology is developed which identifies the parameters of a discrete spring/mass system which is dynamically similar to a point coordinate on a continuous structure. This design methodology is incorporated within another procedure which derives a structure comprising a continuous element and a discrete system. This methodology is used to obtain point coordinate similarity for two planes of motion, which is validated by experimental tests. A limitation of this approach is that it is impossible to achieve multi-coordinate similarity due to an interaction of the discrete system and the continuous element at points away from the coordinate of interest. During the work the importance of the continuous element is highlighted and a design methodology is developed for continuous structures. The design methodology is based upon distributed parameter optimal design techniques and allows an initial poor design estimate to be moved in a feasible direction towards an acceptable design solution. Cumulative damage theory is used to provide a quantitative method of assessing the quality of dynamic similarity. It is shown that the combination of modal analysis techniques and cumulative damage theory provides a feasible design synthesis methodology for representative test rigs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Andean forearc of northern Chile comprises four morphotectonic units, which include from east to west: 1) The Cordillera de la Costa: composed of Jurassic granites and andesites, thought to represent a volcanic arc, the Mejillones terrane, an accreted allochthonous terrane, and the Lower Cretaceous Coloso basin, which formed through forearc extension along the suture between the Mejillones terrane and the Jurassic arc. Palaeomagnetic studies of the above units have identified approximately 29+/-11 degrees of clockwise rotation. Rotation is due to extension (caused by subduction roll back and slab pull), at an angle to the direction of absolute motion of the South American Plate. 2) The Central Depression: a large arid basin containing isolated fault-bounded blocks of pre-Mesozoic metamorphosed igneous rocks, Triassic sediments and volcanics, and Jurassic carbonates, deposited in a. back-arc basin setting. The isolated blocks formed through extension along previous thrust faults, these originated through compression of the back-arc basin due to accretion of the Jurassic volcanic arc. 3) The Precordillera.: composed of Permian-Triassic rift-related sediments and volcanics, Jurassic continental sediments synchronous with back-arc basin sedimentation, and Cretaceous and Oligo-Miocene continental sediments deposited in foreland basins. Palaeomagnetism has identified clockwise rotation in rocks ranging in age from Jurassic-Miocene. Rotation in the Precordillera. affected larger structural blocks than in the Cordillera de la Costa. 4) The Salar Depression: a. series of arid continental basins developed on continental crust. These basins nay have originated in the Triassic, when rifting of the South American craton is thought to have taken place. In conclusion, palaeomagnetic and geological evidence is consistent with the view that the north Chilean forearc was largely under an extensional stress regime. However, the presence of extensive compressional structures in Palaeocene and older rocks in the forearc together with the currently active foreland thrust belt of Argentina. indicate that throughout the evolution of the Andean Orogen, a delicate balance between compressional and extensional tectonic regimes has existed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A preliminary study by Freeman et al (1996b) has suggested that when complex patterns of motion elicit impressions of 2-dimensionality, odd-item-out detection improves given targets can be differentiated on the basis of surface properties. Their results can be accounted for, it if is supposed that observers are permitted efficient access to 3-D surface descriptions but access to 2-D motion descriptions is restricted. To test the hypothesis, a standard search technique was employed, in which targets could be discussed on the basis of slant sign. In one experiment, slant impressions were induced through the summing of deformation and translation components. In a second theory were induced through the summing of shear and translation components. Neither showed any evidence of efficient access. A third experiment explored the possibility that access to these representations may have been hindered by a lack of grouping between the stimuli. Attempts to improve grouping failed to produce convincing evidence in support of life. An alternative explanation is that complex patterns of motion are simply not processed simultaneously. Psychophysical and physiological studies have, however, suggested that multiple mechanisms selective for complex motion do exist. Using a subthreshold summation technique I found evidence supporting the notion that complex motions are processed in parallel. Furthermore, in a spatial summation experiment, coherence thresholds were measured for displays containing different numbers of complex motion patches. Consistent with the idea that complex motion processing proceeds in parallel, increases in the number of motion patches were seen to decrease thresholds, both for expansion and rotation. Moreover, the rates of decrease were higher than those typically expected from probability summation, thus implying mechanisms are available, which can pool signals from spatially distinct complex motion flows.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accurate measurement of intervertebral kinematics of the cervical spine can support the diagnosis of widespread diseases related to neck pain, such as chronic whiplash dysfunction, arthritis, and segmental degeneration. The natural inaccessibility of the spine, its complex anatomy, and the small range of motion only permit concise measurement in vivo. Low dose X-ray fluoroscopy allows time-continuous screening of cervical spine during patient's spontaneous motion. To obtain accurate motion measurements, each vertebra was tracked by means of image processing along a sequence of radiographic images. To obtain a time-continuous representation of motion and to reduce noise in the experimental data, smoothing spline interpolation was used. Estimation of intervertebral motion for cervical segments was obtained by processing patient's fluoroscopic sequence; intervertebral angle and displacement and the instantaneous centre of rotation were computed. The RMS value of fitting errors resulted in about 0.2 degree for rotation and 0.2 mm for displacements. © 2013 Paolo Bifulco et al.