9 resultados para Dental Infection control

em Aston University Research Archive


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Healthcare associated infections may arise from many sources, including patient?s own skin flora and the clinical environment, and inflict a significant burden within the health service. Adequate and effective skin antisepsis and surface disinfection are therefore essential factors in infection control. Current EPIC guidelines recommend 2 % chlorhexidine (CHG) in 70 % isopropyl alcohol (IPA) for skin antisepsis however poor penetration has been reported. Eucalyptus oil (EO) is a known permeation enhancer, producing synergistic antimicrobial activity when combined with CHG. In this current study, the antimicrobial efficacy of EO and its main constituent 1,8-cineole were assessed against a panel of clinically relevant microorganisms, alone and in combination with CHG. The superior antimicrobial efficacy of EO compared with 1,8-cineole, and synergistic effects with CHG against planktonic and biofilm cultures, confirmed its suitability for use in subsequent studies within this thesis. Impregnation of EO, CHG and IPA onto prototype hard surface disinfectant wipes demonstrated significantly improved efficacy compared with CHG/IPA wipes, with clear reductions in the time required to eliminate biofilms. Optimisation of the EO/CHG/IPA formulation resulted in the development of Euclean® wipes, with simulated-use and time kill studies confirming their ability to remove microbial surface contamination, prevent cross contamination and eliminate biofilms within 10 minutes. The employment of isothermal calorimetry provided additional information on the type and rate of antimicrobial activity possessed by Euclean® wipes. A clinical audit of the Euclean® wipes at Birmingham Children?s Hospital, Birmingham, U.K. revealed divided staff opinion, with the highest cited advantage and disadvantage concerning the odour. Finally, skin penetration and cell toxicity studies of EO/CHG biopatches and Euclean® solution developed during this study, revealed no permeation into human skin following biopatch application, and no significant toxicity. These current studies enhance the knowledge regarding EO and its potential applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Serratia spp. are an important cause of hospital-acquired infections and outbreaks in high-risk settings. Twenty-one patients were infected or colonized over a nine-month period during 2001-2002 on a neonatal unit. Twenty-two isolates collected were examined for antibiotic susceptibility, β-lactamase production and genotype. Random-amplified polymorphic DNA polymerase chain reaction and pulsed-field gel electrophoresis revealed that two clones were present. The first clone caused invasive clinical infection in four babies, and was subsequently replaced by a non-invasive clone that affected 14 babies. Phenotypically, the two strains also differed in their prodigiosin production; the first strain was non-pigmented whereas the second strain displayed pink-red pigmentation. Clinical features suggested a difference in their pathogenicity. No environmental source was found. The outbreak terminated following enhanced compliance with infection control measures and a change of antibiotic policy. Although S. marcescens continued to be isolated occasionally for another five months of follow-up, these were sporadic isolates with distinct molecular typing patterns. © 2005 The Hospital Infection Society.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective. To determine whether copper incorporated into hospital ward furnishings and equipment can reduce their surface microbial load. Design. A crossover study. Setting. Acute care medical ward with 19 beds at a large university hospital. Methods. Fourteen types of frequent-touch items made of copper alloy were installed in various locations on an acute care medical ward. These included door handles and push plates, toilet seats and flush handles, grab rails, light switches and pull cord toggles, sockets, overbed tables, dressing trolleys, commodes, taps, and sink fittings. Their surfaces and those of equivalent standard items on the same ward were sampled once weekly for 24 weeks. The copper and standard items were switched over after 12 weeks of sampling to reduce bias in usage patterns. The total aerobic microbial counts and the presence of indicator microorganisms were determined. Results. Eight of the 14 copper item types had microbial counts on their surfaces that were significantly lower than counts on standard materials. The other 6 copper item types had reduced microbial numbers on their surfaces, compared with microbial counts on standard items, but the reduction did not reach statistical significance. Indicator microorganisms were recovered from both types of surfaces; however, significantly fewer copper surfaces were contaminated with vancomycin-resistant enterococci, methicillin-susceptible Staphylococcus aureus, and coliforms, compared with standard surfaces. Conclusions. Copper alloys (greater than or equal to 58% copper), when incorporated into various hospital furnishings and fittings, reduce the surface microorganisms. The use of copper in combination with optimal infection-prevention strategies may therefore further reduce the risk that patients will acquire infection in healthcare environments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We undertook a clinical trial to compare the efficacy of 2% (w/v) chlorhexidine gluconate in 70% (v/v) isopropyl alcohol with the efficacy of 70% (v/v) isopropyl alcohol alone for skin disinfection to prevent peripheral venous catheter colonization and contamination. We found that the addition of 2% chlorhexidine gluconate reduced the number of peripheral venous catheters that were colonized or contaminated. © 2008 by The Society for Healthcare Epidemiology of America. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Effective surface disinfection is a fundamental infection control strategy within healthcare. This study assessed the antimicrobial efficacy of novel biocide formulations comprising 5% and 2% eucalyptus oil (EO) combined with 2% chlorhexidine digluconate (CHG) and 70% isopropyl alcohol (IPA) contained within a wipe. The efficacy of this novel antimicrobial formulation to remove and eliminate methicillin-resistant Staphylococcus aureus (MRSA), Escherichia coli and Candida albicans from steel surfaces was investigated. Adpression studies of pre-contaminated wipes were also utilised to assess their potential to induce cross-contamination between hard surfaces. Furthermore, the bactericidal nature of the EO-formulation was established in addition to time-kill. The EO-containing formulations demonstrated bactericidal antimicrobial efficacy against all microorganisms and did not induce surface cross-contamination. There was no significant difference (p < 0.05) between the 5% and 2% EO formulations in their ability to remove microorganisms from steel surfaces, however both significantly (p < 0.05) removed more than the control formulations. Microbial biofilms were eliminated within 10 min (p < 0.05) when exposed to the EO formulations. Our novel EO-formulation demonstrated rapid antimicrobial efficacy for potential disinfection and elimination of microbial biofilms from hard surfaces and may therefore be a useful adjunct to current infection control strategies currently employed within healthcare facilities.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Clostridium difficile is a bacterial healthcare-associated infection, which houseflies Musca domestica may transfer due to their synanthropic nature. The aims of this thesis were to determine the ability of M. domestica to transfer C. difficile mechanically and to collect and identify flying insects in UK hospitals and classify any associated bacteria. M. domestica exposed to independent suspensions of vegetative cells and spores of C. difficile were able to mechanically transfer the bacteria on to agar for up to 4 hours following exposure. C. difficile could be recovered from fly excreta for 96hrs and was isolated from the M. domestica alimentary canal. Also confirmed was the carriage of C. difficile by M. domestica larvae, although it was not retained in the pupae or in the adults that subsequently developed. Flying insects were collected from ultra-violet light flytraps in hospitals. Flies (order Diptera) were the most commonly identified. Chironomidae were the most common flies, Calliphora vicina were the most common synanthropic fly and ‘drain flies’ were surprisingly numerous and represent an emerging problem in hospitals. External washings and macerates of flying insects were prepared and inoculated onto a variety of agars and following incubation bacterial colonies identified by biochemical tests. A variety of flying insects, including synanthropic flies (e.g. M. domestica and C. vicina) collected from UK hospitals harboured pathogenic bacteria of different species. Enterobacteriaceae were the group of bacteria most commonly isolated, followed by Bacillus spp, Staphylococci, Clostridia, Streptococci and Micrococcus spp. This study highlights the potential for M. domestica to contribute to environmental persistence and spread of C. difficile in hospitals. Also illustrated is the potential for flying insects to contribute to environmental persistence and spread of other pathogenic bacteria in hospitals and therefore the need to implement pest control as part of infection control strategies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To analyze the recent epidemiology of methicillin-resistant Staphylococcus aureus (MRSA) bacteremia in a UK tertiary referral center. Methods: We collected epidemiological and laboratory data on all cases of MRSA bacteremia from September 1, 2005 to December 31, 2007. Results: There were 195 clinically significant episodes. Most were hospital-acquired. Only one episode occurred in patients without a history of hospital admission in the previous 12 months. An intravascular device was the most common focus of infection (37%), with no identifiable source found in 35% of episodes. Twenty-eight percent of patients died within 30 days of bacteremia. Mortality was significantly higher in the absence of an identifiable focus. Failure to include an antibiotic active against MRSA in the empirical treatment was only significantly associated with death in patients showing signs of hemodynamic instability (p < 0.001). No isolates had a minimum inhibitory concentration to vancomycin above 1.5. mg/l and no heteroresistance to glycopeptide antibiotics (heteroresistant vancomycin-intermediate Staphylococcus aureus; hVISA) was detected. All isolates were sensitive to daptomycin, tigecycline, and linezolid. Conclusions: Despite improvement in infection control measures, medical devices remain the most common source of infection. Inappropriate empirical antibiotic usage is associated with a poor outcome in patients with signs of severe sepsis. Susceptibility to glycopeptides and newer antibiotics remains good. © 2010 International Society for Infectious Diseases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A clinical study was undertaken to compare the surface microbial contamination associated with pens constructed of either a copper alloy or stainless steel used by nurses on intensive care units. A significantly lower level of microbial contamination was found on the copper alloy pens. Copyright © 2011 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.