15 resultados para DC system efficiency

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

System efficiency and cost effectiveness are of critical importance for photovoltaic (PV) systems. This paper addresses the two issues by developing a novel three-port dc-dc converter for stand-alone PV systems, based on an improved Flyback-Forward topology. It provides a compact single-unit solution with a combined feature of optimized maximum power point tracking (MPPT), high step-up ratio, galvanic isolation, and multiple operating modes for domestic and aerospace applications. A theoretical analysis is conducted to analyze the operating modes followed by simulation and experimental work. This paper is focused on a comprehensive modulation strategy utilizing both PWM and phase-shifted control that satisfies the requirement of PV power systems to achieve MPPT and output voltage regulation. A 250-W converter was designed and prototyped to provide experimental verification in term of system integration and high conversion efficiency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-volume capacitance is required to buffer the power difference between the input and output ports in single-phase grid-connected photovoltaic inverters, which become an obstacle to high system efficiency and long device lifetime. Furthermore, total harmonic distortion becomes serious when the system runs into low power level. In this study, a comprehensive analysis is introduced for two-stage topology with the consideration of active power, DC-link (DCL) voltage, ripple and capacitance. This study proposed a comprehensive DCL voltage control strategy to minimise the DCL capacitance while maintaining a normal system operation. Furthermore, the proposed control strategy is flexible to be integrated with the pulse-skipping control that significantly improves the power quality at light power conditions. Since the proposed control strategy needs to vary DCL voltage, an active protection scheme is also introduced to prevent any voltage violation across the DCL. The proposed control strategy is evaluated by both simulation and experiments, whose results confirm the system effectiveness.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This industrial based research project was undertaken for British Leyland and arose as a result of poor system efficiency on the Maxi and Marina vehicle body build lines. The major factors in the deterioration of system efficiency were identified as: a) The introduction of a 'Gateline' system of vehicle body build. b) The degeneration of a newly introduced measured daywork payment scheme. By relating the conclusions of past work on payment systems to the situation at Cowley, it was concluded that a combination of poor industrial relations and a lack of managerial control had caused the measured daywork scheme to degenerate into a straightforward payment for time at work. This ellminated the monetary incentive to achieve schedule with the consequence that both inefficiency and operating costs increased. To analyse further the cause of inefficiency, a study of Marina gateline stoppage logs was carried out. This revealed that poor system efficiency on the gateline was caused more by the nature of its design than poor reliability on individual items of' plant. The consideration given to system efficiency at the design stage was found to be negligible, the main obstacles being: a) A lack of understanding pertaining to the influence of certain design factors on the efficiency of a production line. b) The absence of data and techniques to predict system efficiency at the design stage. To remedy this situation, a computer simulation study of' the design factors was carried out from which relationships with system efficiency were established and empirical efficiency equations developed. Sets of tables were compiled from the equations and efficiency data relevant to vehicle body building established from the gateline stoppage logs. Computer simulation, the equations and the tables,when used in conjunction. with good efficiency data, are shown to be accurate methods of predicting production line system.efficiency.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Various micro-radial compressor configurations were investigated using one-dimensional meanline and computational fluid dynamics (CFD) techniques for use in a micro gas turbine (MGT) domestic combined heat and power (DCHP) application. Blade backsweep, shaft speed, and blade height were varied at a constant pressure ratio. Shaft speeds were limited to 220 000 r/min, to enable the use of a turbocharger bearing platform. Off-design compressor performance was established and used to determine the MGT performance envelope; this in turn was used to assess potential cost and environmental savings in a heat-led DCHP operating scenario within the target market of a detached family home. A low target-stage pressure ratio provided an opportunity to reduce diffusion within the impeller. Critically for DCHP, this produced very regular flow, which improved impeller performance for a wider operating envelope. The best performing impeller was a low-speed, 170 000 r/min, low-backsweep, 15° configuration producing 71.76 per cent stage efficiency at a pressure ratio of 2.20. This produced an MGT design point system efficiency of 14.85 per cent at 993 W, matching prime movers in the latest commercial DCHP units. Cost and CO2 savings were 10.7 per cent and 6.3 per cent, respectively, for annual power demands of 17.4 MWht and 6.1 MWhe compared to a standard condensing boiler (with grid) installation. The maximum cost saving (on design point) was 14.2 per cent for annual power demands of 22.62 MWht and 6.1 MWhe corresponding to an 8.1 per cent CO2 saving. When sizing, maximum savings were found with larger heat demands. When sized, maximum savings could be made by encouraging more electricity export either by reducing household electricity consumption or by increasing machine efficiency.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The advent of the harmonic neutralised shunt Converter Compensator as a practical means of reactive power compensation in power transmission systems has cleared ground for wider application of this type of equipment. An experimental 24-pulse voltage sourced convector has been successfully applied in controlling the terminal power factor of a 1.5kW, 240V three phase cage rotor induction motor, whose winding has been used in place of the usual phase shifting transformers. To achieve this, modifications have been made to the conventional stator winding of the induction machine. These include an unconventional phase spread and facilitation of compensator connections to selected tapping points between stator coils to give a three phase winding with a twelve phase connection to the twenty four pulse converter. Theoretical and experimental assessments of the impact of these modifications and attachment of the compensator have shown that there is a slight reduction in the torque developed at a given slip and in the combined system efficiency. There is also an increase in the noise level, also a consequence of the harmonics. The stator leakage inductance gave inadequate coupling reactance between the converter and the effective voltage source, necessitating the use of external inductors in each of the twelve phases. The terminal power factor is fully controllable when the induction machine is used either as a motor or as a generator.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents an assessment of the technical and economic performance of thermal processes to generate electricity from a wood chip feedstock by combustion, gasification and fast pyrolysis. The scope of the work begins with the delivery of a wood chip feedstock at a conversion plant and ends with the supply of electricity to the grid, incorporating wood chip preparation, thermal conversion, and electricity generation in dual fuel diesel engines. Net generating capacities of 1–20 MWe are evaluated. The techno-economic assessment is achieved through the development of a suite of models that are combined to give cost and performance data for the integrated system. The models include feed pretreatment, combustion, atmospheric and pressure gasification, fast pyrolysis with pyrolysis liquid storage and transport (an optional step in de-coupled systems) and diesel engine or turbine power generation. The models calculate system efficiencies, capital costs and production costs. An identical methodology is applied in the development of all the models so that all of the results are directly comparable. The electricity production costs have been calculated for 10th plant systems, indicating the costs that are achievable in the medium term after the high initial costs associated with novel technologies have reduced. The costs converge at the larger scale with the mean electricity price paid in the EU by a large consumer, and there is therefore potential for fast pyrolysis and diesel engine systems to sell electricity directly to large consumers or for on-site generation. However, competition will be fierce at all capacities since electricity production costs vary only slightly between the four biomass to electricity systems that are evaluated. Systems de-coupling is one way that the fast pyrolysis and diesel engine system can distinguish itself from the other conversion technologies. Evaluations in this work show that situations requiring several remote generators are much better served by a large fast pyrolysis plant that supplies fuel to de-coupled diesel engines than by constructing an entire close-coupled system at each generating site. Another advantage of de-coupling is that the fast pyrolysis conversion step and the diesel engine generation step can operate independently, with intermediate storage of the fast pyrolysis liquid fuel, increasing overall reliability. Peak load or seasonal power requirements would also benefit from de-coupling since a small fast pyrolysis plant could operate continuously to produce fuel that is stored for use in the engine on demand. Current electricity production costs for a fast pyrolysis and diesel engine system are 0.091/kWh at 1 MWe when learning effects are included. These systems are handicapped by the typical characteristics of a novel technology: high capital cost, high labour, and low reliability. As such the more established combustion and steam cycle produces lower cost electricity under current conditions. The fast pyrolysis and diesel engine system is a low capital cost option but it also suffers from relatively low system efficiency particularly at high capacities. This low efficiency is the result of a low conversion efficiency of feed energy into the pyrolysis liquid, because of the energy in the char by-product. A sensitivity analysis has highlighted the high impact on electricity production costs of the fast pyrolysis liquids yield. The liquids yield should be set realistically during design, and it should be maintained in practice by careful attention to plant operation and feed quality. Another problem is the high power consumption during feedstock grinding. Efficiencies may be enhanced in ablative fast pyrolysis which can tolerate a chipped feedstock. This has yet to be demonstrated at commercial scale. In summary, the fast pyrolysis and diesel engine system has great potential to generate electricity at a profit in the long term, and at a lower cost than any other biomass to electricity system at small scale. This future viability can only be achieved through the construction of early plant that could, in the short term, be more expensive than the combustion alternative. Profitability in the short term can best be achieved by exploiting niches in the market place and specific features of fast pyrolysis. These include: •countries or regions with fiscal incentives for renewable energy such as premium electricity prices or capital grants; •locations with high electricity prices so that electricity can be sold direct to large consumers or generated on-site by companies who wish to reduce their consumption from the grid; •waste disposal opportunities where feedstocks can attract a gate fee rather than incur a cost; •the ability to store fast pyrolysis liquids as a buffer against shutdowns or as a fuel for peak-load generating plant; •de-coupling opportunities where a large, single pyrolysis plant supplies fuel to several small and remote generators; •small-scale combined heat and power opportunities; •sales of the excess char, although a market has yet to be established for this by-product; and •potential co-production of speciality chemicals and fuel for power generation in fast pyrolysis systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This research is focused on the optimisation of resource utilisation in wireless mobile networks with the consideration of the users’ experienced quality of video streaming services. The study specifically considers the new generation of mobile communication networks, i.e. 4G-LTE, as the main research context. The background study provides an overview of the main properties of the relevant technologies investigated. These include video streaming protocols and networks, video service quality assessment methods, the infrastructure and related functionalities of LTE, and resource allocation algorithms in mobile communication systems. A mathematical model based on an objective and no-reference quality assessment metric for video streaming, namely Pause Intensity, is developed in this work for the evaluation of the continuity of streaming services. The analytical model is verified by extensive simulation and subjective testing on the joint impairment effects of the pause duration and pause frequency. Various types of the video contents and different levels of the impairments have been used in the process of validation tests. It has been shown that Pause Intensity is closely correlated with the subjective quality measurement in terms of the Mean Opinion Score and this correlation property is content independent. Based on the Pause Intensity metric, an optimised resource allocation approach is proposed for the given user requirements, communication system specifications and network performances. This approach concerns both system efficiency and fairness when establishing appropriate resource allocation algorithms, together with the consideration of the correlation between the required and allocated data rates per user. Pause Intensity plays a key role here, representing the required level of Quality of Experience (QoE) to ensure the best balance between system efficiency and fairness. The 3GPP Long Term Evolution (LTE) system is used as the main application environment where the proposed research framework is examined and the results are compared with existing scheduling methods on the achievable fairness, efficiency and correlation. Adaptive video streaming technologies are also investigated and combined with our initiatives on determining the distribution of QoE performance across the network. The resulting scheduling process is controlled through the prioritization of users by considering their perceived quality for the services received. Meanwhile, a trade-off between fairness and efficiency is maintained through an online adjustment of the scheduler’s parameters. Furthermore, Pause Intensity is applied to act as a regulator to realise the rate adaptation function during the end user’s playback of the adaptive streaming service. The adaptive rates under various channel conditions and the shape of the QoE distribution amongst the users for different scheduling policies have been demonstrated in the context of LTE. Finally, the work for interworking between mobile communication system at the macro-cell level and the different deployments of WiFi technologies throughout the macro-cell is presented. A QoEdriven approach is proposed to analyse the offloading mechanism of the user’s data (e.g. video traffic) while the new rate distribution algorithm reshapes the network capacity across the macrocell. The scheduling policy derived is used to regulate the performance of the resource allocation across the fair-efficient spectrum. The associated offloading mechanism can properly control the number of the users within the coverages of the macro-cell base station and each of the WiFi access points involved. The performance of the non-seamless and user-controlled mobile traffic offloading (through the mobile WiFi devices) has been evaluated and compared with that of the standard operator-controlled WiFi hotspots.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Groupe Spécial Mobile (GSM) has been developed as the pan-European second generation of digital mobile systems. GSM operates in the 900 MHz frequency band and employs digital technology instead of the analogue technology of its predecessors. Digital technology enables the GSM system to operate in much smaller zones in comparison with the analogue systems. The GSM system will offer greater roaming facilities to its subscribers, extended throughout the countries that have installed the system. The GSM system could be seen as a further enhancement to European integration. GSM has adopted a contention-based protocol for multipoint-to-point transmission. In particular, the slotted-ALOHA medium access protocol is used to coordinate the transmission of the channel request messages between the scattered mobile stations. Collision still happens when more than one mobile station having the same random reference number attempts to transmit on the same time-slot. In this research, a modified version of this protocol has been developed in order to reduce the number of collisions and hence increase the random access channel throughput compared to the existing protocol. The performance evaluation of the protocol has been carried out using simulation methods. Due to the growing demand for mobile radio telephony as well as for data services, optimal usage of the scarce availability radio spectrum is becoming increasingly important. In this research, a protocol has been developed whereby the number of transmitted information packets over the GSM system is increased without any additional increase of the allocated radio spectrum. Simulation results are presented to show the improvements achieved by the proposed protocol. Cellular mobile radio networks commonly respond to an increase in the service demand by using smaller coverage areas. As a result, the volume of the signalling exchanges increases. In this research, a proposal for interconnecting the various entitles of the mobile radio network over the future broadband networks based on the IEEE 802.6 Metropolitan Area Network (MAN) is outlined. Simulation results are presented to show the benefits achieved by interconnecting these entities over the broadband Networks.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this work was to design, construct and commission a new ablative pyrolysis reactor and a high efficiency product collection system. The reactor was to have a nominal throughput of 10 kg/11r of dry biomass and be inherently scalable up to an industrial scale application of 10 tones/hr. The whole process consists of a bladed ablative pyrolysis reactor, two high efficiency cyclones for char removal and a disk and doughnut quench column combined with a wet walled electrostatic precipitator, which is directly mounted on top, for liquids collection. In order to aid design and scale-up calculations, detailed mathematical modelling was undertaken of the reaction system enabling sizes, efficiencies and operating conditions to be determined. Specifically, a modular approach was taken due to the iterative nature of some of the design methodologies, with the output from one module being the input to the next. Separate modules were developed for the determination of the biomass ablation rate, specification of the reactor capacity, cyclone design, quench column design and electrostatic precipitator design. These models enabled a rigorous design protocol to be developed capable of specifying the required reactor and product collection system size for specified biomass throughputs, operating conditions and collection efficiencies. The reactor proved capable of generating an ablation rate of 0.63 mm/s for pine wood at a temperature of 525 'DC with a relative velocity between the heated surface and reacting biomass particle of 12.1 m/s. The reactor achieved a maximum throughput of 2.3 kg/hr, which was the maximum the biomass feeder could supply. The reactor is capable of being operated at a far higher throughput but this would require a new feeder and drive motor to be purchased. Modelling showed that the reactor is capable of achieving a reactor throughput of approximately 30 kg/hr. This is an area that should be considered for the future as the reactor is currently operating well below its theoretical maximum. Calculations show that the current product collection system could operate efficiently up to a maximum feed rate of 10 kg/Fir, provided the inert gas supply was adjusted accordingly to keep the vapour residence time in the electrostatic precipitator above one second. Operation above 10 kg/hr would require some modifications to the product collection system. Eight experimental runs were documented and considered successful, more were attempted but due to equipment failure had to be abandoned. This does not detract from the fact that the reactor and product collection system design was extremely efficient. The maximum total liquid yield was 64.9 % liquid yields on a dry wood fed basis. It is considered that the liquid yield would have been higher had there been sufficient development time to overcome certain operational difficulties and if longer operating runs had been attempted to offset product losses occurring due to the difficulties in collecting all available product from a large scale collection unit. The liquids collection system was highly efficient and modeling determined a liquid collection efficiency of above 99% on a mass basis. This was validated due to the fact that a dry ice/acetone condenser and a cotton wool filter downstream of the collection unit enabled mass measurements of the amount of condensable product exiting the product collection unit. This showed that the collection efficiency was in excess of 99% on a mass basis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

More-electric vehicle technology is becoming prevalent in a number of transportation systems because of its ability to improve efficiency and reduce costs. This paper examines the specific case of an Uninhabited Autonomous Vehicle (UAV), and the system topology and control elements required to achieve adequate dc distribution voltage bus regulation. Voltage control methods are investigated and a droop control scheme is implemented on the system. Simulation results are also presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper studies the impact that a change from a dealer system to a market-maker supported auction system has on market quality. We study the impact that the introduction of SETSmm at the London Stock Exchange had on firm value, price efficiency and liquidity. We discover a small SETSmm return premium associated with the announcement that securities are to migrate to the new trading system. Moreover, securities that migrate to SETSmm are characterized by improvements to liquidity and pricing efficiency. We find that these changes are related to the return premium.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT One of the current research trends in Enterprise Resource Planning (ERP) involves examining the critical factors for its successful implementation. However, such research is limited to system implementation, not focusing on the flexibility of ERP to respond to changes in business. Therefore, this study explores a combination system, made up of an ERP and informality, intended to provide organisations with efficient and flexible performance simultaneously. In addition, this research analyses the benefits and challenges of using the system. The research was based on socio-technical system (STS) theory which contains two dimensions: 1) a technical dimension which evaluates the performance of the system; and 2) a social dimension which examines the impact of the system on an organisation. A mixed method approach has been followed in this research. The qualitative part aims to understand the constraints of using a single ERP system, and to define a new system corresponding to these problems. To achieve this goal, four Chinese companies operating in different industries were studied, all of which faced challenges in using an ERP system due to complexity and uncertainty in their business environments. The quantitative part contains a discrete-event simulation study that is intended to examine the impact of operational performance when a company implements the hybrid system in a real-life situation. Moreover, this research conducts a further qualitative case study, the better to understand the influence of the system in an organisation. The empirical aspect of the study reveals that an ERP with pre-determined business activities cannot react promptly to unanticipated changes in a business. Incorporating informality into an ERP can react to different situations by using different procedures that are based on the practical knowledge of frontline employees. Furthermore, the simulation study shows that the combination system can achieve a balance between efficiency and flexibility. Unlike existing research, which emphasises a continuous improvement in the IT functions of an enterprise system, this research contributes to providing a definition of a new system in theory, which has mixed performance and contains both the formal practices embedded in an ERP and informal activities based on human knowledge. It supports both cost-efficiency in executing business transactions and flexibility in coping with business uncertainty.This research also indicates risks of using the system, such as using an ERP with limited functions; a high cost for performing informally; and a low system acceptance, owing to a shift in organisational culture. With respect to practical contribution, this research suggests that companies can choose the most suitable enterprise system approach in accordance with their operational strategies. The combination system can be implemented in a company that needs to operate a medium amount of volume and variety. By contrast, the traditional ERP system is better suited in a company that operates a high-level volume market, while an informal system is more suitable for a firm with a requirement for a high level of variety.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study is to provide a comparative analysis of the efficiency of Islamic and conventional banks in Gulf Cooperation Council (GCC) countries. In this study, we explain inefficiencies obtained by introducing firm-specific as well as macroeconomic variables. Our findings indicate that during the eight years of study, conventional banks largely outperform Islamic banks with an average technical efficiency score of 81% compared to 95.57%. However, it is clear that since 2008, efficiency of conventional banks was in a downward trend while the efficiency of their Islamic counterparts was in an upward trend since 2009. This indicates that Islamic banks have succeeded to maintain a level of efficiency during the subprime crisis period. Finally, for the whole sample, the analysis demonstrates the strong link of macroeconomic indicators with efficiency for GCC banks. Surprisingly, we have not found any significant relationship in the case of Islamic banks.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this project is to design a new desalination system with energy efficiency approaching the theoretical thermodynamic limit—even at high recovery ratio. The system uses reverse osmosis (RO) and a batch principle of operation to overcome the problem of concentration factor which prevents continuous-flow RO systems from ever reaching this limit and thus achieving the minimum possible specific energy consumption, SEC. Batch operation comprises a cycle in three phases: pressurisation, purge, and refill. Energy recovery is inherent to the design. Unlike in closed-circuit desalination (CCD), no feedwater is added to the pressure circuit during the pressurisation phase. The batch configuration is compared to standard configurations such as continuous single-stage RO (with energy recovery) and CCD. Theoretical analysis has shown that the new system is able to use 33% less energy than CCD at a recovery ratio of 80%. A prototype has been constructed using readily available parts and tested with feedwater salinities and recovery ratios ranging from 2,000 to 5,000 ppm and 17.2–70.6%, respectively. Results compare very well against the standard configurations. For example, with feedwater containing 5,000 ppm NaCl and recovery ratio of 69%, a hydraulic SEC of 0.31 kWh/m3 was obtained—better than the minimum theoretically possible with a single-stage continuous flow system with energy recovery device.