14 resultados para Cross Infection, prevention
em Aston University Research Archive
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
The aim of this research work was primarily to examine the relevance of patient parameters, ward structures, procedures and practices, in respect of the potential hazards of wound cross-infection and nasal colonisation with multiple resistant strains of Staphylococcus aureus, which it is thought might provide a useful indication of a patient's general susceptibility to wound infection. Information from a large cross-sectional survey involving 12,000 patients from some 41 hospitals and 375 wards was collected over a five-year period from 1967-72, and its validity checked before any subsequent analysis was carried out. Many environmental factors and procedures which had previously been thought (but never conclusively proved) to have an influence on wound infection or nasal colonisation rates, were assessed, and subsequently dismissed as not being significant, provided that the standard of the current range of practices and procedures is maintained and not allowed to deteriorate. Retrospective analysis revealed that the probability of wound infection was influenced by the patient's age, duration of pre-operative hospitalisation, sex, type of wound, presence and type of drain, number of patients in ward, and other special risk factors, whilst nasal colonisation was found to be influenced by the patient's age, total duration of hospitalisation, sex, antibiotics, proportion of occupied beds in the ward, average distance between bed centres and special risk factors. A multi-variate regression analysis technique was used to develop statistical models, consisting of variable patient and environmental factors which were found to have a significant influence on the risks pertaining to wound infection and nasal colonisation. A relationship between wound infection and nasal colonisation was then established and this led to the development of a more advanced model for predicting wound infections, taking advantage of the additional knowledge of the patient's state of nasal colonisation prior to operation.
Resumo:
Objective. To determine whether copper incorporated into hospital ward furnishings and equipment can reduce their surface microbial load. Design. A crossover study. Setting. Acute care medical ward with 19 beds at a large university hospital. Methods. Fourteen types of frequent-touch items made of copper alloy were installed in various locations on an acute care medical ward. These included door handles and push plates, toilet seats and flush handles, grab rails, light switches and pull cord toggles, sockets, overbed tables, dressing trolleys, commodes, taps, and sink fittings. Their surfaces and those of equivalent standard items on the same ward were sampled once weekly for 24 weeks. The copper and standard items were switched over after 12 weeks of sampling to reduce bias in usage patterns. The total aerobic microbial counts and the presence of indicator microorganisms were determined. Results. Eight of the 14 copper item types had microbial counts on their surfaces that were significantly lower than counts on standard materials. The other 6 copper item types had reduced microbial numbers on their surfaces, compared with microbial counts on standard items, but the reduction did not reach statistical significance. Indicator microorganisms were recovered from both types of surfaces; however, significantly fewer copper surfaces were contaminated with vancomycin-resistant enterococci, methicillin-susceptible Staphylococcus aureus, and coliforms, compared with standard surfaces. Conclusions. Copper alloys (greater than or equal to 58% copper), when incorporated into various hospital furnishings and fittings, reduce the surface microorganisms. The use of copper in combination with optimal infection-prevention strategies may therefore further reduce the risk that patients will acquire infection in healthcare environments.
Resumo:
Central venous catheters have become an integral part of patient management however they are associated with many complications including infection. Despite efforts being made to reduce the incidence of such infect ions the problem continues to increase and has resource implications for the Health Service. Studies relating to the source of microorganisms causing CVC-associated infection, the cost of such infections and the efficacy of an antimicrobial catheter have been undertaken. Thirty patients who required a CVC as part of their medical management and underwent cardiac surgery had the distal tips of their catheters sampled whilst in situ. Sampling took place within 1 h of catheter placement. Bacteria were isolated from 16% of the catheter distal tips sampled in situ. The guidewires used to insert the devices were also contaminated (50%). When CVC were inserted via a protective sheath, avoiding contact with the skin. the incidence of microbial contamination was reduced. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted onto the distal tip of CVC during the insertion procedure. Needleless intravascular access devices have been introduced in order to reduce the incidence of need1estick injury. However, it was unclear whether such connectors would act as a portal of entry for microorganisms to CVC. The efficacy of these devices was investigated. Within the controlled laboratory environment it was demonstrated that needleless devices, when challenged with microorganisms, did not allow the passage of microbes when flu id was injected. This therefore suggested that the devices should not increase the risk of catheter colonisation. When used in clinical practice however microbial contamination of the needleless connectors was 55 % in comparison to the routinely used luer connectors (23%). The cost of infections associated with CVC was determined. Twenty patients catheterised with a CVC designed for long term use who were admitted to hospital with a presumptive diagnosis of catheter-related infection were studied. The treatment given specifically for this infection was costed. The mean cost of such an infection was £ 1781.81. Throughout the UK this may amount to £1.565.906 per annum. The cost of infections associated with CVC designed for short term use was estimated to be between 5 and 7 million pounds per annum in the UK. In an attempt to reduce both the incidence and cost of catheter- related infection antimicrobial CVC have been developed. The efficacy of a novel polyurethane CVC impregnated on both the internal and external catheter surface with the quaternary ammonium compound benzalkonium chloride was investigated. Eighty eight patients received an antimicrobial catheter and 78 patients a conventional polyurethane CVC. The anti-microbial CVC resulted in a reduction in microbial colonisation of the external and internal polymer surfaces as compared to the control device. The observed reduction in microbial colonisation with the anti-microbial CVC may decrease the likelihood of subsequent infection offering a useful approach to the prevention of catheter-related infections.
Resumo:
The potential source of CVC colonisation was assessed. Isolates of coagulase-negative staphylococci (CoNS) recovered from the skin and CVC components of 3 cardiothoracic surgery patients were characterised by pulsed-field gel electrophoresis (PFGE). The genetic heterogeneity of CoNS isolated from the skin was demonstrated and specific genotypes implicated in catheter colonisation. In addition, phenotypic and genotypic typing techniques were assessed for their ability to characterise strains of CoNS recovered from 33 patients who developed catheter-related bloodstream infection (CR-BSI) on a bone marrow transplant (BMT) unit and Siaphylococcus aureus recovered from 6 cardiothoracic surgery patients with surgical site infection (SSI) following median sternotomy. This epidemiological investigation revealed that common strains of CoNS and 51 aureus where not associated with infection in patients with CR-BSI or sternal SSI during the study period. Furthermore, there was no correlation between phenotypic and genotypic characterisation results. The variable expression of phenotypic traits within strains of staphylococci was evident whilst PFGE and randomly amplified polymorphic DNA (RAPD) were highly discriminatory for the molecular characterisation of S. aureus and CoNS. This was highlighted in 8 stem cell transplant (SCT) patients whereby it was demonstrated that routine identification and characterisation of CoNS by phenotypic techniques may not be adequate for the diagnosis of CR-BSI by current guidelines. The potential of the lipid S ELISA to facilitate the diagnosis of CR-BSI in 38 haematology/SCT patients and sternal SSI in 57 cardiothoracic surgery patients was also assessed. The ELISA proved to be a sensitive test for the rapid serodiagnosis of infection due to staphylococci in immunocompetent patients. The acridine orange leucocyte cytospin test (AOLC) was also evaluated for the rapid diagnosis of CR-BSI in 16 haematology/SCT patients with Hickman CVC in situ. Although the sensitivity of the test was low, it may provide a useful adjunct to conventional methods for the in situ sampling of catheters to predict and diagnose CR-BSI, preventing the unnecessary removal of CVC.
Resumo:
Surgical site infections (SSI) are a prevalent health care-associated infection (HAl). Prior to the mid-19th century, surgical sites commonly developed postoperative wound complications. It was in the 1860's, after Joseph Lister introduced carbolic acid and the principles of antisepsis that postoperative wound infection significantly decreased. Today, patient preoperative skin preparation with an antiseptic agent prior to surgery is a standard of practice. Povidone-iodine and chlorhexidine gluconate are currently the most commonly used antimicrobial agents used to prep the patient's skin. In this current study, the epidemiology, diagnosis, surveillance and prevention of SSI with chlorhexidine were investigated. The antimicrobial activity of chlorhexidine was assessed. In in-vitro and in-vivo studies the antimicrobial efficacy of 2% (w/v) chlorhexidine gluconate (CHG) in 70% isopropyl alcohol (IPA) and 10% povidoneiodine (PVP-I) in the presence of 0.9% normal saline or blood were examined. The 2% CHG in 70% IPA solutions antimicrobial activity was not diminished in the presence of 0.9% normal saline or blood. In comparison, the traditional patient preoperative skin preparation, 10% PVP-I antimicrobial activity was not diminished in the presence of 0.9% normal saline, but was diminished in the presence of blood. In an in-vivo human volunteer study the potential for reduction of the antimicrobial efficacy of aqueous patient preoperative skin preparations compromised by mechanical removal of wet product from the application site (blot) was assessed. In this evaluation, 2% CHG and 10% povidone-iodine (PVP-I) were blotted from the patient's skin after application to the test site. The blotting, or mechanical removal, of the wet antiseptic from the application site did not produce a significant difference in product efficacy. In a clinical trial to compare 2% CHG in 70% IPA and PVP-! scrub and paint patient preoperative skin preparation for the prevention of SSI, there were 849 patients randomly assigned to the study groups (409 in the chlorhexidine-alcohol and 440 in the povidone-iodine group) in the intention-to-treat analysis. The overall surgical site infection was significantly lower in the 2% CHG in 70% IPA group than in the PVP-I group (9.5% versus 16.1 %, p=0.004; relative risk, 0.59 with 95% confidence interval of 0.41 to 0.85). Preoperative cleansing of the patient's skin with chlorhexidine-alcohol is superior to povidone-iodine in preventing surgical site infection after clean-contaminated surgery.
Resumo:
Contraceptive diaphragms offer a discreet method of pregnancy protection that women can use when needed with no side effects. Incorporating antiretroviral HIV microbicides into such devices may also provide protection against HIV infection. The paper gives a brief outline of the work being conducted by PATH, CONRAD and QUB on the development of a microbicide-releasing SILCS diaphragm. The design, engineering and manufacturing challenges that have been encountered will be discussed, as well as the potential impact such a device could have in the developing world.
Resumo:
The theory of planned behaviour (TPB) has been used successfully in the past to account for pedestrians' intentions to cross the road in risky situations. However, accident statistics show age and gender differences in the likelihood of adult pedestrian accidents. This study extends earlier work by examining the relative importance of the model components as predictors of intention to cross for four different adult age groups, men, women, drivers and nondrivers. The groups did not differ in the extent to which they differentiated between two situations of varying perceived risk. The model fit was good, but accounted for less of the variance in intention for the youngest group (17-24) than for other age groups. Differences between the age groups in intention to cross seemed to be due to differences in perceived value of crossing rather than differences in perceived risk. Women were less likely to intend to cross than men and perceived more risk, and there were important age, gender and driver status differences in the importance of the TPB variables as predictors of intention. A key implication of these findings is that road safety interventions need to be designed differently for different groups. © 2006 Elsevier Ltd. All rights reserved.
Resumo:
The objectives are to examine rural road accident data in order to develop a method by which high accident rate locations and accident causes can be identified, and also to develop proposals for improvements at such locations and to identify measures which will improve road safety throughout the country. The problem of road safety in Iran is an important issue, because of the tragic and unnecessary loss of life, and the enormous cost of accidents in the country. The resources available to deal with the problems are limited and must be allocated on priority basis. This study represents an initial effort to identify the extent of the problem in order to take remedial measures. A study was made of all the available road accident data collected by agencies related to road safety in Iran, and the major organisations responsible for road safety development were visited. The Vice Minister of Roads and Transportation selected for this study a 280 Km rural road in South West Iran. Mainly because of the lack of suitable maps and plans of the roads, it was not possible to accurately identify the location of accidents. Accident scene data was subsequently collected by the highway police and personally by the author. The data for the study road was then analysed to identify 'high accident rate' locations, and also to determine, as far as was possible, the reasons for the accidents. The study suggests specific improvements for each of the high accident rate locations examined (eg. the building of dual carriageways with central guard rails to reduce the risk of collision with oncoming vehicles, pedestrian facilities to allow pedestrians to cross dangerous roadsl]. In addition recommendations are made to guide and assist the major organisations responsible for road safety in Iran. These recommendations are: (al for improving accident data collection and storage (bl for subsequent analysis for taking remedial measures with a view to accident prevention
Resumo:
The environment may act as a reservoir for pathogens that cause healthcare-associated infections (HCAIs). Approaches to reducing environmental microbial contamination in addition to cleaning are thus worthy of consideration. Copper is well recognised as having antimicrobial activity but this property has not been applied to the clinical setting. We explored its use in a novel cross-over study on an acute medical ward. A toilet seat, set of tap handles and a ward entrance door push plate each containing copper were sampled for the presence of micro-organisms and compared to equivalent standard, non-copper-containing items on the same ward. Items were sampled once weekly for 10 weeks at 07:00 and 17:00. After five weeks, the copper-containing and non-copper-containing items were interchanged. The total aerobic microbial counts per cm2 including the presence of ‘indicator micro-organisms’ were determined. Median numbers of microorganisms harboured by the copper-containing items were between 90% and 100% lower than their control equivalents at both 07:00 and 17:00. This reached statistical significance for each item with one exception. Based on the median total aerobic cfu counts from the study period, five out of ten control sample points and zero out of ten copper points failed proposed benchmark values of a total aerobic count of <5 cfu/cm2. All indicator micro-organisms were only isolated from control items with the exception of one item during one week. The use of copper-containing materials for surfaces in the hospital environment may therefore be a valuable adjunct for the prevention of HCAIs and requires further evaluation.
Resumo:
Tissue transglutaminase (tTG) is a Ca2+-dependent enzyme which cross-links proteins via e(g-glutamyl)lysine bridges. There is increasing evidence that tTG is involved in wound repair and tissue stabilization, as well as in physiological mechanisms leading to cell death. To investigate the role of this enzyme in tissue wounding leading to loss of Ca2+ homoeostasis, we initially used a model involving electroporation to reproduce cell wounding under controlled conditions. Two cell models were used whereby tTG expression is regulated either by antisense silencing in ECV 304 cells or by using transfected Swiss 3T3 cells in which tTG expression is under the control of the tet regulatory system. Using these cells, loss of Ca2+ homoeostasis following electroporation led to a tTG-dependent formation of highly cross-linked proteinaceous shells from intracellular proteins. Formation of these structures is dependent on elevated intracellular Ca2+, but it is independent of intracellular proteases and is near maximal after only 20min post-wounding. Using labelled primary amines as an indicator of tTG activity within these 'wounded cells', we demonstrate that tTG modifies a wide range of proteins that are present in both the perinuclear and intranuclear spaces. The demonstration of entrapped DNA within these shell structures, which showed limited fragmentation, provides evidence that the high degree of transglutaminase cross-linking results in the prevention of DNA release, which may serve to dampen any subsequent inflammatory response. Comparable observations were shown when monolayers of cells were mechanically wounded by scratching. In this second model of cell wounding, redistribution of tTG activity to the extracellular matrix was also demonstrated, an effect which may serve to stabilize tissues post-trauma, and thus contribute to the maintenance of tissue integrity.
Resumo:
Letter to the Editor
Resumo:
Virus-specific CD8+ T cells are known to play an important role in the control of HIV infection. In this study we investigated whether there may be qualitative differences in the CD8+ T cell response in HIV-1- and HIV-2-infected individuals that contribute to the relatively efficient control of the latter infection. A molecular comparison of global TCR heterogeneity showed a more oligoclonal pattern of CD8 cells in HIV-1- than HIV-2-infected patients. This was reflected in restricted and conserved TCR usage by CD8+ T cells recognizing individual HLA-A2- and HLA-B57-restricted viral epitopes in HIV-1, with limited plasticity in their response to amino acid substitutions within these epitopes. The more diverse TCR usage observed for HIV-2-specific CD8 T cells was associated with an enhanced potential for CD8+ expansion and IFN- production on cross-recognition of variant epitopes. Our data suggest a mechanism that could account for any possible cross-protection that may be mediated by HIV-2-specific CD8+ T cells against HIV-1 infection. Furthermore, they have implications for HIV vaccine development, demonstrating an association between a polyclonal, virus-specific CD8+ T cell response and an enhanced capacity to tolerate substitutions within T cell epitopes.