7 resultados para Continuous glucose monitoring
em Aston University Research Archive
Resumo:
Aim: To evaluate OneTouch® Verio™ test strip performance at hypoglycaemic blood glucose (BG) levels (<3.9mmol/L [<70mg/dL]) at seven clinical studies. Methods: Trained clinical staff performed duplicate capillary BG monitoring system tests on 700 individuals with type 1 and type 2 diabetes using blood from a single fingerstick lancing. BG reference values were obtained using a YSI 2300 STAT™ Glucose Analyzer. The number and percentage of BG values within ±0.83. mmol/L (±15. mg/dL) and ±0.56. mmol/L (±10. mg/dL) were calculated at BG concentrations of <3.9. mmol/L (<70. mg/dL), <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL). Results: At BG concentrations <3.9. mmol/L (<70. mg/dL), 674/674 (100%) of meter results were within ±0.83. mmol/L (±15. mg/dL) and 666/674 (98.8%) were within ±0.56. mmol/L (±10. mg/dL) of reference values. At BG concentrations <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL), 358/358 (100%) and 270/270 (100%) were within ±0.56. mmol/L (±10. mg/dL) of reference values, respectively. Conclusion: In this analysis of data from seven independent studies, OneTouch Verio test strips provide highly accurate results at hypoglycaemic BG levels. © 2012 Elsevier Ireland Ltd.
Resumo:
Lowering glucose levels, while avoiding hypoglycaemia, can be challenging in insulin-treated patients with diabetes. We evaluated the role of ambulatory glucose profile in optimising glycaemic control in this population. Insulin-treated patients with type 1 and type 2 diabetes were recruited into a prospective, multicentre, 100-day study and randomised to control (n = 28) or intervention (n = 59) groups. The intervention group used ambulatory glucose profile, generated by continuous glucose monitoring, to assess daily glucose levels, whereas the controls relied on capillary glucose testing. Patients were reviewed at days 30 and 45 by the health care professional to adjust insulin therapy. Comparing first and last 2 weeks of the study, ambulatory glucose profile-monitored type 2 diabetes patients (n = 28) showed increased time in euglycaemia (mean ± standard deviation) by 1.4 ± 3.5 h/day (p = 0.0427) associated with reduction in HbA1c from 77 ± 15 to 67 ± 13 mmol/mol (p = 0.0002) without increased hypoglycaemia. Type 1 diabetes patients (n = 25) showed reduction in hypoglycaemia from 1.4 ± 1.7 to 0.8 ± 0.8 h/day (p = 0.0472) associated with a marginal HbA1c decrease from 75 ± 10 to 72 ± 8 mmol/mol (p = 0.0508). Largely similar findings were observed comparing intervention and control groups at end of study. In conclusion, ambulatory glucose profile helps glycaemic management in insulin-treated diabetes patients by increasing time spent in euglycaemia and decreasing HbA1c in type 2 diabetes patients, while reducing hypoglycaemia in type 1 diabetes patients.
Resumo:
Background: Self-monitoring of blood glucose is controversial in the management of type 2 diabetes. Some research suggests that self-monitoring improves glycaemic control, whereas other research is sceptical about its value for people with type 2 diabetes who are not on insulin. Although blood glucose meters are widely available and used by this group, patients' own views are absent from the debate. Aim: To explore the pros and cons of glucose monitoring from the patients' perspectives. Design of study: Qualitative repeat-interview study. Setting: Patients were recruited from 16 general practices and three hospital clinics within four local healthcare cooperatives in Lothian, Scotland. Method: Interview data from 40 patients diagnosed with type 2 diabetes within the previous 6 months were analysed using thematic analysis informed by grounded theory. We report findings from round 1 and round 2 interviews. Results: Glucose monitoring can heighten patients' awareness of the impact of lifestyle; for example, dietary choices, on blood glucose levels. Glucose monitoring amplifies a sense of 'success' or 'failure' about self-management, often resulting in anxiety and self-blame if glucose readings remain consistently high. Moreover, monitoring can negatively effect patients' self-management when readings are counter-intuitive. Conclusion: Our analysis highlights the importance of understanding the meanings that newly diagnosed patients attach to glucose self-monitoring. To maximise the positive effects of self-monitoring, health professionals should ensure that patients understand the purpose of monitoring and should clarify with patients how readings should be interpreted. © British Journal of General Practice.
Resumo:
Aims To date, there is no convincing evidence that non-insulin treated patients who undertake self-blood glucose monitoring (SBGM) have better glycaemic control than those who test their urine. This has led to a recommendation that non-insulin dependent patients undertake urine testing, which is the cheaper option. This recommendation does not take account of patients' experiences and views. This study explores the respective merits of urine testing and SBGM from the perspectives of newly diagnosed patients with Type 2 diabetes. Methods Qualitative study using repeat in-depth interviews with 40 patients. Patients were interviewed three times at 6-monthly intervals over 1 year. Patients were recruited from hospital clinics and general practices in Lothian, Scotland. The study was informed by grounded theory, which involves concurrent data collection and analysis. Results Patients reported strongly negative views of urine testing, particularly when they compared it with SBGM. Patients perceived urine testing as less convenient, less hygienic and less accurate than SBGM. Most patients assumed that blood glucose meters were given to those with a more advanced or serious form of diabetes. This could have implications for how they thought about their own disease. Patients often interpreted negative urine results as indicating that they could not have diabetes. Conclusions Professionals should be aware of the meanings and understandings patients attach to the receipt and use of different types of self-monitoring equipment. Guidelines that promote the use of consistent criteria for equipment allocation are required. The manner in which negative urine results are conveyed needs to be reconsidered.
Resumo:
I was recently part of a small committee looking at higher qualifications in contact lens practice and the discussion turned to future technologies. There was mention of different materials and different applications of contact lenses. Drug delivery with contact lenses was discussed as this has been talked about in the literature for a while. The first paper I could find that talked about using contact lenses for drug delivery dates back over 40 years. There was a review paper in CLAE in 2008 that looked specifically at this too [1]. However, where are these products? Why are we not seeing them in the market place? Maybe the technology is not quite there yet, or maybe patents are prohibiting usage or maybe the market is not big enough to develop such products? We do have lenses on the market with slow release of lubricating agents but not therapeutic agents used for ocular or systemic conditions. Contact lenses with pathogen detectors may be part of our contact lens armoury of the future and again we can already see papers in the literature that have trialled this technology for glucose monitoring in diabetics or lactate concentration in the tear film. Future contact lenses may incorporate better optics based on aberration control and we see this starting to emerge with aspheric designs designed to minimise spherical aberration. Irregular corneas can be fitted with topography based designs and again this technology exists and is being used by some manufacturers in their designs already. Moreover, the topography based fitting of irregular corneas is certainly something we see a lot of today and CLAE has seen many articles related to this over the last decade or so. What about further into the future? Well one interesting area must the 3-dimensional contact lenses, or contact lenses with electronic devices built in that simulate a display screen. A little like the virtual display spectacles that are already sold by electronics companies. It does not take much of a stretch of the imagination to see a large electronic company taking this technology on and making it viable. Will we see people on the train watching movies on these electronic virtual reality contact lenses? I think we will, but when is harder to know.
Resumo:
Objective: To explore views of patients with type 2 diabetes about self monitoring of blood glucose over time. Design: Longitudinal, qualitative study. Setting: Primary and secondary care settings across Lothian, Scotland. Participants: 18 patients with type 2 diabetes. Main outcome measures: Results from repeat in-depth interviews with patients over four years after clinical diagnosis. Results: Analysis revealed three main themes - the role of health professionals, interpreting readings and managing high values, and the ongoing role of blood glucose self monitoring. Self monitoring decreased over time, and health professionals' behaviour seemed crucial in this: participants interpreted doctors' focus on levels of haemoglobin A1c, and lack of perceived interest in meter readings, as indicating that self monitoring was not worth continuing. Some participants saw readings as a proxy measure of good and bad behaviour - with women especially, chastising themselves when readings were high. Some participants continued to find readings difficult to interpret, with uncertainty about how to respond to high readings. Reassurance and habit were key reasons for continuing. There was little indication that participants were using self monitoring to effect and maintain behaviour change. Conclusions: Clinical uncertainty about the efficacy and role of blood glucose self monitoring in patients with type 2 diabetes is mirrored in patients' own accounts. Patients tended not to act on their self monitoring results, in part because of a lack of education about the appropriate response to readings. Health professionals should be explicit about whether and when such patients should self monitor and how they should interpret and act upon the results, especially high readings.
Resumo:
Background: To examine the views and current practice of SMBG among Black Caribbean and South Asian individuals with non-insulin treated Type 2 diabetes mellitus. Methods: Twelve participants completed semi-structured interviews that were guided by the Health Belief Model and analyzed using thematic network analysis. Results: The frequency of monitoring among participants varied from several times a day to once per week. Most participants expressed similar experiences regarding their views and practices of SMBG. Minor differences across gender and culture were observed. All participants understood the benefits, but not all viewed SMBG as beneficial to their personal diabetes management. SMBG can facilitate a better understanding and maintenance of self-care behaviours. However, it can trigger both positive and negative emotional responses, such as a sense of disappointment when high readings are not anticipated, resulting in emotional distress. Health care professionals play a key role in the way SMBG is perceived and used by patients. Conclusion: While the majority of participants value SMBG as a self-management tool, barriers exist that impede its practice, particularly its cost. How individuals cope with these barriers is integral to understanding why some patients adopt SMBG more than others. © 2013 Gucciardi et al.; licensee BioMed Central Ltd.