18 resultados para Congenital anomalies
em Aston University Research Archive
Resumo:
As in other areas of the body, developmental anomalies of the eye arise as a result of the disturbance of events during embryology and in a proportion of cases these anomalies are genetically inherited. Developmental anomalies that occur early in embryonic life may be so severe that the embryo may not survive but others result in the birth of healthy babies but with developmental eye defects of varying severity. The most dramatic developmental defects of the eye include anophthalmos (complete absence of an eye), microphthalmos (a general failure of the eye to develop resulting in a small, undeveloped eye), coloboma (caused by failure of the optic vesicle to invaginate), and aniridia (complete or partial loss of the iris). The present article does not provide an exhaustive review of the topic but considers the major types of developmental anomaly to affect the eye and will discuss how recent progress in genetics has increased our understanding of these disorders. The major genes linked to the developmental anomalies are discussed as well as how defects in these genes might lead to specific problems.
Resumo:
One of the objectives of the molecular biological study of glaucoma is to establish how the disease develops as a result of the production of aberrant gene products. Many of the genes associated with glaucoma code for proteins which are likely to be directly or indirectly involved in the development and/or function of cells within the trabecular meshwork. The identification of specific defects in these genes is likely to lead to a better understanding of the mechanisms involved in PCG and glaucoma in general and to the development of alternative therapies to surgery. The CYP1B1 gene in particular, which is a linked to congenital glaucoma, and is expressed in the trabecular meshwork, codes for a member of the cytochrome P450 group of proteins. These iron binding proteins constitute a family of enzymes involved in the processes of xenobiotic metabolism, growth, and development. The discovery of the CYP1B1 gene in PCG emphases the importance of abnormalities in the molecular structure of proteins expressed in cells of the trabecular network as a cause of PCG. The identification of specific genetic defects leads to the possibility of more widespread screening for PCG especially in affected families and hence, the possibility of the identification of asymptomatic carriers of the disease. Early identification of 'at risk' parents may then enable earlier detection of PCG and intervention in the infant.
Resumo:
Purpose: To report the outcome of retinal artery macroaneurysm associated with a congenital anomalous retinal artery. Methods: The patient was examined with ophthalmoscopy and fluorescein angiography. Results: A 60-year-old woman presented with visual acuity of 20/80 in her right eye. She was found to have an abnormal retinal vessel emerging from the optic disk, passing toward the center of the macula, and looping back toward the disk. The center of the loop had a leaking macroaneurysm, which was treated conservatively. At the 4-month follow-up visit, the visual acuity in the right eye had improved to 20/20 with resolution of most of the macular edema, exudates, and hemorrhage. Conclusion: This case demonstrates that retinal artery macroaneurysm can be successfully managed with a conservative approach, even when associated with a congenital anomalous retinal vessel.
Resumo:
Background: Introducing neonatal screening procedures may not be readily accepted by parents and may increase anxiety. The acceptability of pulse oximetry screening to parents has not been previously reported. Objective: To assess maternal acceptability of pulse oximetry screening for congenital heart defects and to identify factors predictive of participation in screening. Design and setting: A questionnaire was completed by a cross-sectional sample of mothers whose babies were recruited into the PulseOx Study which investigated the test accuracy of pulse oximetry screening. Participants: A total of 119 mothers of babies with false-positive (FP) results, 15 with true-positive and 679 with true-negative results following screening. Main outcome measures: Questionnaires included measures of satisfaction with screening, anxiety, depression and perceptions of test results. Results: Participants were predominantly satisfied with screening. The anxiety of mothers given FP results was not significantly higher than that of mothers given true-negative results (median score 32.7 vs 30.0, p=0.09). White British/Irish mothers were more likely to participate in screening, with a decline rate of 5%; other ethnic groups were more likely to decline with the largest increase in declining being for Black African mothers (21%, OR 4.6, 95% CI 3.8 to 5.5). White British mothers were also less anxious (p<0.001) and more satisfied (p<0.001) than those of other ethnicities Conclusions: Pulse oximetry screening was acceptable to mothers and FP results were not found to increase anxiety. Factors leading to differences in participation and satisfaction across ethnic groups need to be identified so that staff can support parents appropriately.
Resumo:
Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. Setting: Six UK maternity units. Participants: These were 20,055 asymptomatic newborns at = 35 weeks’ gestation, their mothers and health-care staff. Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). Main outcome measures: Detection of major CHDs – defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.
Resumo:
The tear film, cornea and lens dictate the refractive power of the eye and the retinal image quality is principally defined by diffraction, whole eye wavefront error, scatter, and chromatic aberration. Diffraction and wave aberration are fundamentally pupil diameter dependent; however scatter can be induced by refractive surgery and in the normal ageing eye becomes an increasingly important factor defining retinal image quality. The component of visual quality most affected by the tear film, refractive surgery and multifocal contact and intraocular lenses is the wave aberration of the eye. This body of work demonstrates the effects of each of these anomalies on the visual quality of the eye. When assessing normal or borderline self-diagnosed dry eye subjects using aberrometry, combining lubricating eye drops and spray does not offer any benefit over individual products. However, subjects perceive a difference in comfort for all interventions after one hour. Total higher order aberrations increase after laser assisted sub-epithelial keratectomy performed using a solid-state laser on myopes, but this causes no significant decrease in contrast sensitivity or increase in glare disability. Mean sensitivity and reliability indices for perimetry were comparable to pre-surgery results. Multifocal contact lenses and intraocular lenses are designed to maximise vision when the patient is binocular, so any evaluation of the eyes individually is confounded by reduced individual visual acuity and visual quality. Different designs of aspheric multifocal contact lenses do not provide the same level of visual quality. Multifocal contact lenses adversely affect mean deviation values for perimetry and this should be considered when screening individuals with multifocal contact or intraocular lenses. Photographic image quality obtained through a multifocal contact or intraocular lens appears to be unchanged. Future work should evaluate the effect of these anomalies in combination; with the aim of providing the best visual quality possible and supplying normative data for screening purposes.
Resumo:
Congenital nystagmus is an ocular-motor disorder characterised by involuntary, conjugated and bilateral to and fro ocular oscillations. In this study a method to recognise automatically jerk waveform inside a congenital nystagmus recording and to compute foveation time and foveation position variability is presented. The recordings were performed with subjects looking at visual targets, presented in nine eye gaze positions; data were segmented into blocks corresponding to each gaze position. The nystagmus cycles were identified searching for local minima and maxima (SpEp sequence) in intervals centred on each slope change of the eye position signal (position criterion). The SpEp sequence was then refined using an adaptive threshold applied to the eye velocity signal; the outcome is a robust detection of each slow phase start point, fundamental to accurately compute some nystagmus parameters. A total of 1206 slow phases was used to compute the specificity in waveform recognition applying only the position criterion or adding the adaptive threshold; results showed an increase in negative predictive value of 25.1% using both features. The duration of each foveation window was measured on raw data or using an interpolating function of the congenital nystagmus slow phases; foveation time estimation less sensitive to noise was obtained in the second case. © 2010.
Resumo:
The recent development of using negative stiffness inclusions to achieve extreme overall stiffness and mechanical damping of composite materials reveals a new avenue for constructing high performance materials. One of the negative stiffness sources can be obtained from phase transforming materials in the vicinity of their phase transition, as suggested by the Landau theory. To understand the underlying mechanism from a microscopic viewpoint, we theoretically analyze a 2D, nested triangular lattice cell with pre-chosen elements containing negative stiffness to demonstrate anomalies in overall stiffness and damping. Combining with current knowledge from continuum models, based on the composite theory, such as the Voigt, Reuss, and Hashin-Shtrikman model, we further explore the stability of the system with Lyapunov's indirect stability theorem. The evolution of the microstructure in terms of the discrete system is discussed. A potential application of the results presented here is to develop special thin films with unusual in-plane mechanical properties. © 2006 Elsevier B.V. All rights reserved.
Resumo:
Congenital nystagmus (CN) is an ocular-motor disorder characterised by involuntary, conjugated ocular oscillations and its pathogenesis is still under investigation. This kind of nystagmus is termed congenital (or infantile) since it could be present at birth or it can arise in the first months of life. Most of CN patients show a considerable decrease of their visual acuity: image fixation on the retina is disturbed by nystagmus continuous oscillations, mainly horizontal. However, the image of a given target can still be stable during short periods in which eye velocity slows down while the target image is placed onto the fovea (called foveation intervals). To quantify the extent of nystagmus, eye movement recording are routinely employed, allowing physicians to extract and analyse nystagmus main features such as waveform shape, amplitude and frequency. Using eye movement recording, it is also possible to compute estimated visual acuity predictors: analytical functions which estimates expected visual acuity using signal features such as foveation time and foveation position variability. Use of those functions extend the information from typical visual acuity measurement (e.g. Landolt C test) and could be a support for therapy planning or monitoring. This study focuses on detection of CN patients' waveform type and on foveation time measure. Specifically, it proposes a robust method to recognize cycles corresponding to the specific CN waveform in the eye movement pattern and, for those cycles, evaluate the exact signal tracts in which a subject foveates. About 40 eyemovement recordings, either infrared-oculographic or electrooculographic, were acquired from 16 CN subjects. Results suggest that the use of an adaptive threshold applied to the eye velocity signal could improve the estimation of slow phase start point. This can enhance foveation time computing and reduce influence of repositioning saccades and data noise on the waveform type identification.
Resumo:
Congenital nystagmus (CN) is an ocular-motor disorder that appears at birth or during the first few months of life; it is characterised by involuntary, conjugated, bilateral to and fro ocular oscillations. Pathogenesis of congenital nystagmus is still unknown. Eye movement recording allow to extract and analyse nystagmus main features such as shape, amplitude and frequency; depending on the morphology of the oscillations nystagmus can be classified in different categories (pendular, jerk, horizontal unidirectional, bidirectional). In general, CN patient show a considerable decrease of the visual acuity: image fixation on the retina is disturbed by nystagmus continuous oscillations; however, image stabilisation is still achieved during the short foveation periods in which eye velocity slows down while the target image is placed onto the fovea. Visual acuity was found to be mainly dependent on foveation periods duration, but cycle-to-cycle foveation repeatability and reduction of retinal image velocities also contribute in increasing visual acuity. This study concentrate on cycle-to-cycle image position variation onto fovea, trying to characterise the sequences of foveation positions. Eye-movement (infrared oculographic or electro oculographic) recordings, relative to different gaze positions and belonging to more than 30 CN patients, were analysed. Preliminary results suggest that sequences of foveations show a cyclic pattern with a dominant frequency (around 0.3 Hz on average) much lower than that of the nystagmus (about 3.3 Hz on average). Sequences of foveations reveals an horizontal ocular swing of more than 2 degree on average, which can explain the low visual acuity of the CN patient. Current CN therapies, pharmacological treatment or surgery of the ocular muscles, mainly aim to increase the patient's visual acuity. Hence, it is fundamental to have an objective parameter (expected visual acuity) for therapy planning. The information about sequences of foveations can improve estimation of patient visual acuity. © 2008 Springer-Verlag.
Resumo:
Infantile Nystagmus Syndrome, or Congenital Nystagmus, is an ocular-motor disorder characterized by involuntary, conjugated and bilateral to and fro ocular oscillations. Good visual acuity in congenital nystagmus can be achieved during the foveation periods in which eye velocity slows down while the target image crosses the fovea. Visual acuity was found to be mainly dependent on the duration of the foveation periods. In this work a new approach is proposed for estimation of foveation parameters: a cubic spline interpolation of the nystagmus recording before localizing the start point of foveation window and to estimate its duration. The performances of the proposed algorithm were assessed in comparison with a previously developed algorithm, used here as gold standard. The obtained results suggest that the spline interpolation could be a useful tool to filter the eye movement recordings before applying an algorithm to estimate the foveation window parameters. © 2013 IEEE.
Resumo:
Along with other diseases that can affect binocular vision, reducing the visual quality of a subject, Congenital Nystagmus (CN) is of peculiar interest. CN is an ocular-motor disorder characterized by involuntary, conjugated ocular oscillations and, while identified more than forty years ago, its pathogenesis is still under investigation. This kind of nystagmus is termed congenital (or infantile) since it could be present at birth or it can arise in the first months of life. The majority of CN patients show a considerable decrease of their visual acuity: image fixation on the retina is disturbed by nystagmus continuous oscillations, mainly horizontal. However, the image of a given target can still be stable during short periods in which eye velocity slows down while the target image is placed onto the fovea (called foveation intervals). To quantify the extent of nystagmus, eye movement recordings are routinely employed, allowing physicians to extract and analyze nystagmus main features such as waveform shape, amplitude and frequency. Use of eye movement recording, opportunely processed, allows computing "estimated visual acuity" predictors, which are analytical functions that estimate expected visual acuity using signal features such as foveation time and foveation position variability. Hence, it is fundamental to develop robust and accurate methods to measure both those parameters in order to obtain reliable values from the predictors. In this chapter the current methods to record eye movements in subjects with congenital nystagmus will be discussed and the present techniques to accurately compute foveation time and eye position will be presented. This study aims to disclose new methodologies in congenital nystagmus eye movements analysis, in order to identify nystagmus cycles and to evaluate foveation time, reducing the influence of repositioning saccades and data noise on the critical parameters of the estimation functions. Use of those functions extends the information acquired with typical visual acuity measurement (e.g., Landolt C test) and could be a support for treatment planning or therapy monitoring. © 2010 by Nova Science Publishers, Inc. All rights reserved.
Foveation time measure in Congenital Nystagmus through second order approximation of the slow phases
Resumo:
Congenital Nystagmus (CN) is an ocular-motor disorder characterised by involuntary, conjugated ocular oscillations, and its pathogenesis is still unknown. The pathology is de fined as "congenital" from the onset time of its arise which could be at birth or in the first months of life. Visual acuity in CN subjects is often diminished due to nystagmus continuous oscillations, mainly on the horizontal plane, which disturb image fixation on the retina. However, during short periods in which eye velocity slows down while the target image is placed onto the fovea (called foveation intervals) the image of a given target can still be stable, allowing a subject to reach a higher visual acuity. In CN subjects, visual acuity is usually assessed both using typical measurement techniques (e.g. Landolt C test) and with eye movement recording in different gaze positions. The offline study of eye movement recordings allows physicians to analyse nystagmus main features such as waveform shape, amplitude and frequency and to compute estimated visual acuity predictors. This analytical functions estimates the best corrected visual acuity using foveation time and foveation position variability, hence a reliable estimation of this two parameters is a fundamental factor in assessing visual acuity. This work aims to enhance the foveation time estimation in CN eye movement recording, computing a second order approximation of the slow phase components of nystag-mus oscillations. About 19 infraredoculographic eye-movement recordings from 10 CN subjects were acquired and the visual acuity assessed with an acuity predictor was compared to the one measured in primary position. Results suggest that visual acuity measurements based on foveation time estimation obtained from interpolated data are closer to value obtained during Landolt C tests. © 2010 IEEE.
Resumo:
Congenital nystagmus is an ocular-motor disorder that develops in the first few months of life; its pathogenesis is still unknown. Patients affected by congenital nystagmus show continuous, involuntary, rhythmical oscillations of the eyes. Monitoring eye movements, nystagmus main features such as shape, amplitude and frequency, can be extracted and analysed. Previous studies highlighted, in some cases, a much slower and smaller oscillation, which appears added up to the ordinary nystagmus waveform. This sort of baseline oscillation, or slow nystagmus, hinder precise cycle-to-cycle image placement onto the fovea. Such variability of the position may reduce patient visual acuity. This study aims to analyse more extensively eye movements recording including the baseline oscillation and investigate possible relationships between these slow oscillations and nystagmus. Almost 100 eye movement recordings (either infrared-oculographic or electrooculographic), relative to different gaze positions, belonging to 32 congenital nystagmus patients were analysed. The baseline oscillation was assumed sinusoidal; its amplitude and frequency were computed and compared with those of the nystagmus by means of a linear regression analysis. The results showed that baseline oscillations were characterised by an average frequency of 0.36 Hz (SD 0.11 Hz) and an average amplitude of 2.1° (SD 1.6°). It also resulted in a considerable correlation (R2 scored 0.78) between nystagmus amplitude and baseline oscillation amplitude; the latter, on average, resulted to be about one-half of the correspondent nystagmus amplitude. © 2009 Elsevier Ltd. All rights reserved.