15 resultados para Compliant cannula

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent developments in aerostatic thrust bearings have included: (a) the porous aerostatic thrust bearing containing a porous pad and (b) the inherently compensated compliant surface aerostatic thrust bearing containing a thin elastomer layer. Both these developments have been reported to improve the bearing load capacity compared to conventional aerostatic thrust bearings with rigid surfaces. This development is carried one stage further in a porous and compliant aerostatic thrust bearing incorporating both a porous pad and an opposing compliant surface. The thin elastomer layer forming the compliant surface is bonded to a rigid backing and is of a soft rubber like material. Such a bearing is studied experimentally and theoretically under steady state operating conditions. A mathematical model is presented to predict the bearing performance. In this model is a simplified solution to the elasticity equations for deflections of the compliant surface. Account is also taken of deflections in the porous pad due to the pressure difference across its thickness. The lubrication equations for flow in the porous pad and bearing clearance are solved by numerical finite difference methods. An iteration procedure is used to couple deflections of the compliant surface and porous pad with solutions to the lubrication equations. Comparisons between experimental results and theoretically predicted bearing performance are in good agreement. However these results show that the porous and compliant aerostatic thrust bearing performance is lower than that of a porous aerostatic thrust bearing with a rigid surface in place of the compliant surface. This discovery is accounted to the recess formed in the bearing clearance by deflections of the compliant surface and its effect on flow through the porous pad.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

How does the non-executant state ensure that its agents are fulfilling their obligations to deliver nationally determined policies? In the case of elected local government in England and Wales, this function is carried out by the Audit Commission (AC) for Local Authorities and the Health Service for England and Wales. Since being established in 1983, it is the means by which local authorities are held to account by central government, both for its own purposes and on behalf of other interested stakeholders. Although the primary function of the AC is to ensure that local authorities are fulfilling their obligations, it does so by using different methods. By acting as a regulator, an independent expert, an opinion former and a mediator, the AC steers local authorities to ensure that they are compliant with the regulatory regime and are implementing legislation properly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adopting and maintaining a healthy diet is pivotal to diabetic regimens. Behavioural research has focused on strategies to modify/maintain healthy behaviours; thus 'compliance' and 'non-compliance' are operationalized by researchers. In contrast, discursive psychology focuses on the actions different accounts accomplish-in this case regarding diets. Using thematic discourse analysis, we examine dietary management talk in repeat-interviews with 40 newly diagnosed type 2 diabetes patients. Women in our study tended to construct dietary practices as an individual concern, while men presented food consumption as a family matter. Participants accounted for 'cheating' in complex ways that aim to accomplish, for instance, a compliant identity. Discursive psychology may facilitate fluidity in our understandings of dietary management, and challenge fixed notions of 'compliant' and 'non-compliant' diabetes patients. Copyright © 2005 SAGE Publications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis is an evaluation of practices to control antibiotic prescribing in UK NHS hospitals. Within the past ten years there has been increasing international concern about escalating antibiotic resistance, and the UK has issued several policy documents for pmdent antibiotic prescribing. Chief Pharmacists in 253 UK NHS hospitals were surveyed about the availability and nature of documents to control antibiotic prescribing (formularies, policies and guidelines), and the role of pharmacists and medical microbiologists in monitoring prescribers' compliance with the recommendations of such documents. Although 235 hospitals had at least one document, only 60% had both an antibiotic formulary and guidelines, and only about one-half planned an annual revision of document(s). Pharmacists were reported as mostly checking antibiotic prescribing on every ward whilst medical microbiologists mostly visited selected units only. Response to a similar questionnaire was obtained from the Chief Medical Microbiologists in 131 UK NHS hospitals. Comparisons of the questionnaires indicated areas of apparent disagreement about the roles of pharmacists and medical microbiologists. Eighty three paired-responses received from pharmacists and medical microbiologists in the same hospital revealed poor agreement and awareness about controls. A total of 205 institutional prescribing guidelines were analysed for recommendations for the empirical antibiotic prescribing of Community-Acquired Pneumonia (CAP). Variation was observed in recommendations and agreement with national guidance from the British Thoracic Society (BTS). A questionnaire was subsequently sent to 235 Chief Pharmacists to investigate their awareness of this new guidance from the BTS, and subsequent revision of institutional guidelines. Documents had been revised in only about one-half of hospitals where pharmacists were aware of the new guidance. An audit of empirical antibiotic prescribing practices for CAP was performed at one hospital. Although problems were experienced with retrieval of medical records, diagnostic criteria were poorly recorded, and only 57% of prescribing for non-severe CAP was compliant with institutional guidelines. A survey of clinicians at the same hospital identified that almost one-half used the institutional guidelines and most found them useful. However, areas for improvement concernmg awareness of the guidelines and ease of access were identified. It is important that hospitals are equipped to react to changes in the hospital environment including frequent movement of junior doctors between institutions, the employment of specialist "infectious diseases pharmacists" and the increasing benefits offered by information technology. Recommendations for policy have been suggested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis presents the design, fabrication and testing of novel grating based Optical Fibre Sensor (OFS) systems being interrogated using “off the shelf” interrogation systems, with the eventual development of marketable commercial systems at the forefront of the research. Both in the industrial weighing and aerospace industries, there has been a drive to investigate the feasibility of using optical fibre sensors being deployed where traditionally their electrical or mechanical counterparts would traditionally have been. Already, in the industrial weighing industry, commercial operators are deploying OFS-based Weigh-In-Motion (WIM) systems. Likewise, in the aerospace industry, OFS have been deployed to monitor such parameters as load history, impact detection, structural damage, overload detection, centre of gravity and the determination of blade shape. Based on the intrinsic properties of fibre Bragg gratings (FBGs) and Long Period Fibre Gratings (LPFGs), a number of novel OFS-based systems have been realised. Experimental work has shown that in the case of static industrial weighing, FBGs can be integrated with current commercial products and used to detect applied loads. The work has also shown that embedding FBGs in e-glass, to form a sensing patch, can result in said patches being bonded to rail track, forming the basis of an FBG-based WIM system. The results obtained have been sufficiently encouraging to the industrial partner that this work will be progressed beyond the scope of the work presented in this thesis. Likewise, and to the best of the author’s knowledge, a novel Bragg grating based systems for aircraft fuel parameter sensing has been presented. FBG-based pressure sensors have been shown to demonstrate good sensitivity, linearity and repeatability, whilst LPFG-based systems have demonstrated a far greater sensitivity when compared to FBGs, as well the advantage of being potentially able to detect causes of fuel adulteration based on their sensitivity to refractive index (RI). In the case of the LPFG-based system, considerable work remains to be done on the mechanical strengthening to improve its survivability in a live aircraft fuel tank environment. The FBG system has already been developed to an aerospace compliant prototype and is due to be tested at the fuel testing facility based at Airbus, Filton, UK. It is envisaged by the author that in both application areas, continued research in this area will lead to the eventual development of marketable commercial products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiovascular disease (CVD) continues to be one of the top causes of mortality in the world. World Heart Organization (WHO) reported that in 2004, CVD contributed to almost 30% of death from estimated worldwide death figures of 58 million[1]. Heart failure treatment varies from lifestyle adjustment to heart transplantation; its aims are to reduce HF symptoms, prolong patient survival and minimize risk [2]. One alternative available in the market for HF treatment is Left Ventricular Assist Device (LVAD). Chronic Intermittent Mechanical Support (CIMS) device is a novel (LVAD) heart failure treatment using counterpulsation similar to Intra Aortic Balloon Pumps (IABP). However, the implantation site of the CIMS balloon is in the ascending aorta just distal to aortic valve contrasted with IABP in the descending aorta. Counterpulsation coupled with implantation close to the aortic valve enables comparable flow augmentation with reduced balloon volume. Two prototypes of the CIMS balloon were constructed using rapid prototyping: the straight-body model is a cylindrical tube with a silicone membrane lining with zero expansive compliance. The compliant-body model had a bulging structure that allowed the membrane to expand under native systolic pressure increasing the device’s static compliance to 1.5 mL/mmHg. This study examined the effect of device compliance and vascular compliance on counterpulsating flow augmentation. Both prototypes were tested on a two-element Windkessel model human mock circulatory loop (MCL). The devices were placed just distal to aortic valve and left coronary artery. The MCL mimicked HF with cardiac output of 3 L/min, left ventricular pressure of 85/15 mmHg, aortic pressure of 70/50 mmHg and left coronary artery flow rate of 66 mL/min. The mean arterial pressure (MAP) was calculated to be 57 mmHg. Arterial compliance was set to be1.25 mL/mmHg and 2.5 mL/mmHg. Inflation of the balloon was triggered at the dicrotic notch while deflation was at minimum aortic pressure prior to systole. Important haemodynamics parameters such as left ventricular pressure (LVP), aortic pressure (AoP), cardiac output (CO), left coronary artery flowrate (QcorMean), and dP (Peak aortic diastolic augmentation pressure – AoPmax ) were simultaneously recorded for both non-assisted mode and assisted mode. ANOVA was used to analyse the effect of both factors (balloon and arterial compliance) to flow augmentation. The results showed that for cardiac output and left coronary artery flowrate, there were significant difference between balloon and arterial compliance at p < 0.001. Cardiac output recorded maximum output at 18% for compliant body and stiff arterial compliance. Left coronary artery flowrate also recorded around 20% increase due to compliant body and stiffer arterial compliance. Resistance to blood ejection recorded highest difference for combination of straight body and stiffer arterial compliance. From these results it is clear that both balloon and arterial compliance are statistically significant factors for flow augmentation on peripheral artery and reduction of resistance. Although the result for resistance reduction was different from flow augmentation, these results serves as an important aspect which will influence the future design of the CIMS balloon and its control strategy. References: 1. Mathers C, Boerma T, Fat DM. The Global Burden of disease:2004 update. Geneva: World Heatlh Organization; 2008. 2. Jessup M, Brozena S. Heart Failure. N Engl J Med 2003;348:2007-18.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A multicore fibre (MCF) sensor to measure the radial deformation of a compliant cylinder under compression is presented. The sensor is connectorised and need not be permanently bonded to the test object. A differential measurement technique using FBGs written into the MCF makes the sensor temperature insensitive. FBG measurement of axial strain of a cylinder under compression is also reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the importance of dataset fitness-for-use evaluation and intercomparison is widely recognised within the GIS community, no practical tools have yet been developed to support such interrogation. GeoViQua aims to develop a GEO label which will visually summarise and allow interrogation of key informational aspects of geospatial datasets upon which users rely when selecting datasets for use. The proposed GEO label will be integrated in the Global Earth Observation System of Systems (GEOSS) and will be used as a value and trust indicator for datasets accessible through the GEO Portal. As envisioned, the GEO label will act as a decision support mechanism for dataset selection and thereby hopefully improve user recognition of the quality of datasets. To date we have conducted 3 user studies to (1) identify the informational aspects of geospatial datasets upon which users rely when assessing dataset quality and trustworthiness, (2) elicit initial user views on a GEO label and its potential role and (3), evaluate prototype label visualisations. Our first study revealed that, when evaluating quality of data, users consider 8 facets: dataset producer information; producer comments on dataset quality; dataset compliance with international standards; community advice; dataset ratings; links to dataset citations; expert value judgements; and quantitative quality information. Our second study confirmed the relevance of these facets in terms of the community-perceived function that a GEO label should fulfil: users and producers of geospatial data supported the concept of a GEO label that provides a drill-down interrogation facility covering all 8 informational aspects. Consequently, we developed three prototype label visualisations and evaluated their comparative effectiveness and user preference via a third user study to arrive at a final graphical GEO label representation. When integrated in the GEOSS, an individual GEO label will be provided for each dataset in the GEOSS clearinghouse (or other data portals and clearinghouses) based on its available quality information. Producer and feedback metadata documents are being used to dynamically assess information availability and generate the GEO labels. The producer metadata document can either be a standard ISO compliant metadata record supplied with the dataset, or an extended version of a GeoViQua-derived metadata record, and is used to assess the availability of a producer profile, producer comments, compliance with standards, citations and quantitative quality information. GeoViQua is also currently developing a feedback server to collect and encode (as metadata records) user and producer feedback on datasets; these metadata records will be used to assess the availability of user comments, ratings, expert reviews and user-supplied citations for a dataset. The GEO label will provide drill-down functionality which will allow a user to navigate to a GEO label page offering detailed quality information for its associated dataset. At this stage, we are developing the GEO label service that will be used to provide GEO labels on demand based on supplied metadata records. In this presentation, we will provide a comprehensive overview of the GEO label development process, with specific emphasis on the GEO label implementation and integration into the GEOSS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Objective: To maximise the benefit from statin therapy, patients must maintain regular therapy indefinitely. Non-compliance is thought to be common in those taking medication at regular intervals over long periods of time, especially where they may perceive no immediate benefit (News editorial, 2002). This study extends previous work in which commonly held prescribing data is used as a surrogate marker of compliance and was designed to examine compliance in those stabilised on statins in a large General Practice. Design: Following ethical approval, details of all patients who had a single statin for 12 consecutive months with no changes in drug, frequency or dose, between December 1999 and March 2003, were obtained. Setting: An Eastern Birmingham Primary Care Trust GP surgery. Main Outcome Measures: A compliance ratio was calculated by dividing the number of days treatment by the number of doses prescribed. For a once daily regimen the ratio for full compliance_1. Results: 324 patients were identified. The average compliance ratio for the first six months of the study was 1.06 ± 0.01 (range 0.46 – 2.13) and for the full twelve months was 1.05 ± 0.01 (range 0.58 – 2.08). Conclusions: The data shown here indicates that as a group, long-term, stabilised statin users appear compliant. However, the range of values obtained show that there are identifiable subsets of patients who are not taking their therapy as prescribed. Although the apparent use of more doses than prescribed in some patients may result from medication hording, this cannot be the case in the patients who apparently take less. It has been demonstrated here that the compliance ratio can be used as an early indicator of problems allowing targeted compliance advice can be given where it will have the most benefit. References: News Editorial. Pharmacy records could be used to enhance statin compliance in elderly. Pharm. J. 2002; 269: 121.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A multicore fibre (MCF) sensor to measure the radial deformation of a compliant cylinder under compression is presented. The sensor is connectorised and need not be permanently bonded to the test object. A differential measurement technique using FBGs written into the MCF makes the sensor temperature insensitive. FBG measurement of axial strain of a cylinder under compression is also reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This book provides a practical guide for accountants working in practice or in business faced with the complexity of moving to adopt IFRS-based financial reporting. The book offers not only an overview of the regulatory framework and the requirements to produce IFRS-compliant financial statements but also guidance on developing an implementation strategy including project management, identifying and responding to challenges, dealing with change management and communication with external stakeholders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a method of uncertainty evaluation for axi-symmetric measurement machines which is compliant with GUM and PUMA methodologies. Specialized measuring machines for the inspection of axisymmetric components enable the measurement of properties such as roundness (radial runout), axial runout and coning. These machines typically consist of a rotary table and a number of contact measurement probes located on slideways. Sources of uncertainty include the probe calibration process, probe repeatability, probe alignment, geometric errors in the rotary table, the dimensional stability of the structure holding the probes and form errors in the reference hemisphere which is used to calibrate the system. The generic method is described and an evaluation of an industrial machine is described as a worked example. Type A uncertainties were obtained from a repeatability study of the probe calibration process, a repeatability study of the actual measurement process, a system stability test and an elastic deformation test. Type B uncertainties were obtained from calibration certificates and estimates. Expanded uncertainties, at 95% confidence, were then calculated for the measurement of; radial runout (1.2 µm with a plunger probe or 1.7 µm with a lever probe); axial runout (1.2 µm with a plunger probe or 1.5 µm with a lever probe); and coning/swash (0.44 arc seconds with a plunger probe or 0.60 arc seconds with a lever probe).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A cost-effective radio over fiber system to up-convert and transmit multigigabit signals at 60 GHz is presented. A low intermediate frequency OFDM signal is used to directly modulate a laser, which is combined with an independent unmodulated laser. The generated millimeter wave frequency can be adjusted by tuning the frequency separation between the lasers. Since no external modulator is required, this technique is low-cost and it is easily integrable in a single chip. In this paper, we present numerical results showing the feasibility of generating an IEEE 802.15.3c compliant 3.5-Gbps 60-GHz OFDM. We show that received signal quality is not limited by the lasers' linewidth but by the relative intensity noise. © 2013 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optical fibre based sensors are transforming industry by permitting monitoring in hitherto inaccessible environments or measurement approaches that cannot be reproduced using conventional electronic sensors. A multitude of techniques have been developed to render the fibres sensitive to a wide range of parameters including: temperature, strain, pressure (static and dynamic), acceleration, rotation, gas type, and specific biochemical species. Constructed entirely of glass or polymer material, optical fibre devices like fibre gratings offer the properties: low loss, dielectric construction, small size, multiplexing, and so on [1-3]. In this paper, the authors will show the latest developing industrial applications, using polymer optical fibre (POF) devices, and comparing their performance with silica optical fibre devices. The authors address two pressing commercial requirements. The first concerns the monitoring of fuel level in civil aircraft. There is a strong motivation in the aerospace industry to move away from electrical sensors, especially in the fuel system. This is driven by the need to eliminate potential ignition hazards, the desire to reduce cabling weight and the need to mitigate the effects of lightning strikes in aircraft where the conventional metallic skin is increasingly being replaced by composite materials. In this case, the authors have developed pressure sensors based on a diaphragm in which a polymer fibre Bragg grating (POFBG) has been embedded [3]. These devices provide high pressure sensitivity enabling level measurement in the mm range. Also, it has developed an approach incorporating several such sensors which can compensate for temperature drifts and is insensitive to fluid density. Compared with silica fibre-based sensors, their performance is highly enhanced. Initial results have attracted the interest of Airbus from UK, who is keen to explore the potential of optical technology in commercial aircraft. The second concerns the monitoring of acoustic signals and vibration in the subsea environment, for applications in geophysical surveying and security (detection of unwanted craft or personnel). There is strong motivation to move away from electrical sensors due to the bulk of the sensor and associated cabling and the impossibility of monitoring over large distances without electrical amplification. Optical approaches like optical hydrophones [5] offer a means of overcoming these difficulties. In collaboration with Kongsberg from Norway, the authors will exploit the sensitivity improvements possible by using POF instead of silica fibre. These improvements will arise as a result of the much more compliant nature of POF compared to silica fibre (3 GPa vs 72 GPa, respectively). Essentially, and despite the strain sensitivity of silica and POFBGs being very similar, this renders the POF much more sensitive to the applied stress resulting from acoustic signals or vibration. An alternative way of viewing this is that the POF is better impedance-matched to the surrounding environment (water for the intended applications), because although its impedance is higher than that of water, it is nearly an order of magnitude smaller than that of silica. Finally, other future industrial applications will be presented and discussed, showing the vast range of the optical fiber devices in sensing applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the compliance of Daily Disposable Contact Lenses (DDCLs) wearers with replacing lenses at a manufacturer-recommended replacement frequency. To evaluate the ability of two different Health Behavioural Theories (HBT), The Health Belief Model (HBM) and The Theory of Planned Behaviour (TPB), in predicting compliance. Method: A multi-centre survey was conducted using a questionnaire completed anonymously by contact lens wearers during the purchase of DDCLs. Results: Three hundred and fifty-four questionnaires were returned. The survey comprised 58.5% females and 41.5% males (mean age 34. ±. 12. years). Twenty-three percent of respondents were non-compliant with manufacturer-recommended replacement frequency (re-using DDCLs at least once). The main reason for re-using DDCLs was "to save money" (35%). Predictions of compliance behaviour (past behaviour or future intentions) on the basis of the two HBT was investigated through logistic regression analysis: both TPB factors (subjective norms and perceived behavioural control) were significant (p. <. 0.01); HBM was less predictive with only the severity (past behaviour and future intentions) and perceived benefit (only for past behaviour) as significant factors (p. <. 0.05). Conclusions: Non-compliance with DDCLs replacement is widespread, affecting 1 out of 4 Italian wearers. Results from the TPB model show that the involvement of persons socially close to the wearers (subjective norms) and the improvement of the procedure of behavioural control of daily replacement (behavioural control) are of paramount importance in improving compliance. With reference to the HBM, it is important to warn DDCLs wearers of the severity of a contact-lens-related eye infection, and to underline the possibility of its prevention.