6 resultados para Color vision Evaluation tests

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The classic hypothesis of Livingstone and Hubel (1984, 1987) proposed two types of color pathways in primate visual cortex based on recordings from single cells: a segregated, modularpathway that signals color but provides little information about shape or form and a second pathway that signals color differences and so defines forms without the need to specify their colors. A major problem has been to reconcile this neurophysiological hypothesis with the behavioral data. A wealth of psychophysical studies has demonstrated that color vision has orientation-tuned responses and little impairment on form related tasks, but these have not revealed any direct evidence for nonoriented mechanisms. Here we use a psychophysical method of subthreshold summation across orthogonal orientations for isoluminant red-green gratings in monocular and dichoptic viewing conditions to differentiate between nonoriented and orientation-tuned responses to color contrast. We reveal nonoriented color responses at low spatial frequencies (0.25-0.375 c/deg) under monocular conditions changing to orientation-tuned responses at higher spatial frequencies (1.5 c/deg) and under binocular conditions. We suggest that two distinct pathways coexist in color vision at the behavioral level, revealed at different spatial scales: one is isotropic, monocular, and best equipped for the representation of surface color, and the other is orientation-tuned, binocular, and selective for shape and form. This advances our understanding of the organization of the neural pathways involved in human color vision and provides a strong link between neurophysiological and behavioral data. © 2013 ARVO.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To study the density and cross-sectional area of axons in the optic nerve in elderly control subjects and in cases of Alzheimer's disease (AD) using an image analysis system. Methods: Sections of optic nerves from control and AD patients were stained with toluidine blue to reveal axon profiles. Results: The density of axons was reduced in both the center and peripheral portions of the optic nerve in AD compared with control patients. Analysis of axons with different cross-sectional areas suggested a specific loss of the smaller sized axons in AD, i.e., those with areas less that 1.99 μm2. An analysis of axons >11 μm2 in cross-sectional area suggested no specific loss of the larger axons in this group of patients. Conclusions: The data suggest that image analysis provides an accurate and reproducible method of quantifying axons in the optic nerve. In addition, the data suggest that axons are lost throughout the optic nerve with a specific loss of the smaller-sized axons. Loss of the smaller axons may explain the deficits in color vision observed in a significant proportion of patients with AD.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the UK, low vision rehabilitation is delivered by a wide variety of providers with different strategies being used to integrate services from health, social care and the voluntary sector. In order to capture the current diversity of service provision the Low vision Service Model Evaluation (LOVSME) project aimed to profile selected low vision services using published standards for service delivery as a guide. Seven geographically and organizationally varied low-vision services across England were chosen for their diversity and all agreed to participate. A series of questionnaires and follow-up visits were undertaken to obtain a comprehensive description of each service, including the staff workloads and the cost of providing the service. In this paper the strengths of each model of delivery are discussed, and examples of good practice identified. As a result of the project, an Assessment Framework tool has been developed that aims to help other service providers evaluate different aspects of their own service to identify any gaps in existing service provision, and will act as a benchmark for future service development.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background/Aims: To develop and assess the psychometric validity of a Chinese language Vision Health related quality-of-life (VRQoL) measurement instrument for the Chinese visually impaired. Methods: The Low Vision Quality of Life Questionnaire (LVQOL) was translated and adapted into the Chinese-version Low Vision Quality of Life Questionnaire (CLVQOL). The CLVQOL was completed by 100 randomly selected people with low vision (primary group) and 100 people with normal vision (control group). Ninety-four participants from the primary group completed the CLVQOL a second time 2 weeks later (test-retest group). The internal consistency reliability, test-retest reliability, item-internal consistency, item-discrimination validity, construct validity and discriminatory power of the CLVQOL were calculated. Results: The review committee agreed that the CLVQOL replicated the meaning of the LVQOL and was sensitive to cultural differences. The Cronbach's α coefficient and the split-half coefficient for the four scales and total CLVQOL scales were 0.75-0.97. The test-retest reliability as estimated by the intraclass correlations coefficient was 0.69-0.95. Item-internal consistency was >0.4 and item-discrimination validity was generally <0.40. The Varimax rotation factor analysis of the CLVQOL identified four principal factors. the quality-of-life rating of four subscales and the total score of the CLVQOL of the primary group were lower than those of the Control group, both in hospital-based subjects and community-based subjects. Conclusion: The CLVQOL Chinese is a culturally specific vision-related quality-of-life measure instrument. It satisfies conventional psychometric criteria, discriminates visually healthy populations from low vision patients and may be valuable in screening the local community as well as for use in clinical practice or research. © Springer 2005.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A sizeable amount of the testing in eye care, requires either the identification of targets such as letters to assess functional vision, or the subjective evaluation of imagery by an examiner. Computers can render a variety of different targets on their monitors and can be used to store and analyse ophthalmic images. However, existing computing hardware tends to be large, screen resolutions are often too low, and objective assessments of ophthalmic images unreliable. Recent advances in mobile computing hardware and computer-vision systems can be used to enhance clinical testing in optometry. High resolution touch screens embedded in mobile devices, can render targets at a wide variety of distances and can be used to record and respond to patient responses, automating testing methods. This has opened up new opportunities in computerised near vision testing. Equally, new image processing techniques can be used to increase the validity and reliability of objective computer vision systems. Three novel apps for assessing reading speed, contrast sensitivity and amplitude of accommodation were created by the author to demonstrate the potential of mobile computing to enhance clinical measurement. The reading speed app could present sentences effectively, control illumination and automate the testing procedure for reading speed assessment. Meanwhile the contrast sensitivity app made use of a bit stealing technique and swept frequency target, to rapidly assess a patient’s full contrast sensitivity function at both near and far distances. Finally, customised electronic hardware was created and interfaced to an app on a smartphone device to allow free space amplitude of accommodation measurement. A new geometrical model of the tear film and a ray tracing simulation of a Placido disc topographer were produced to provide insights on the effect of tear film breakdown on ophthalmic images. Furthermore, a new computer vision system, that used a novel eye-lash segmentation technique, was created to demonstrate the potential of computer vision systems for the clinical assessment of tear stability. Studies undertaken by the author to assess the validity and repeatability of the novel apps, found that their repeatability was comparable to, or better, than existing clinical methods for reading speed and contrast sensitivity assessment. Furthermore, the apps offered reduced examination times in comparison to their paper based equivalents. The reading speed and amplitude of accommodation apps correlated highly with existing methods of assessment supporting their validity. Their still remains questions over the validity of using a swept frequency sine-wave target to assess patient’s contrast sensitivity functions as no clinical test provides the range of spatial frequencies and contrasts, nor equivalent assessment at distance and near. A validation study of the new computer vision system found that the authors tear metric correlated better with existing subjective measures of tear film stability than those of a competing computer-vision system. However, repeatability was poor in comparison to the subjective measures due to eye lash interference. The new mobile apps, computer vision system, and studies outlined in this thesis provide further insight into the potential of applying mobile and image processing technology to enhance clinical testing by eye care professionals.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Age-related macular degeneration (ARMD) is a major cause of irreversible visual loss in the elderly and a significant threat to their quality of life. Although low vision services often improve the functional outcomes of individuals with macular disease, it remains unclear whether or not they have any impact on quality of life. The principal aim of this study was to determine the effect of a hospital-based low vision clinic on the quality of life of individuals with ARMD. Methods: Forty patients with ARMD attended the low vision clinic at Milton Keynes University Hospital. Quality of life was measured with the vision-specific Low Vision Quality of Life (LVQOL) questionnaire and the general health EuroQol (EQ-5D-5L) questionnaire. Measures were completed at baseline (time zero, T0), and at three- (T3) and six-month (T6) follow-up visits. Results: The near visual acuity of individuals attending the low vision clinic for the first time improved significantly between visits T0 and T3 (p=0.005), reflecting the practiced use of their newly-dispensed low vision aids. As expected, there was no significant change in near acuity over this time period for existing patients. For both new and existing patients, a significant increase in LVQOL score was evident between visits T0 and T3, with a further significant improvement between T3 and T6. Similarly, there was a significant decrease in EQ-5D-5L questionnaire scores between visits T0 and T6. Conclusions: The higher LVQOL scores obtained at the end of the study period (T6) provide evidence that low vision services at Milton Keynes University Hospital served to improve patient quality of life. The reduction in EQ-5D-5L scores over the same time period suggests that low vision services also provide for an improvement in general health-related quality of life. Impact: The findings support the cause of low vision services to improve not only the vision and functional outcomes of individuals with macular disease but also their quality of life. Moreover, the findings suggest that a more efficient allocation of resources at low vision clinics may be possible through the standardisation of patient follow-up frequency.