8 resultados para Clinical Trial

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The CancerGrid consortium is developing open-standards cancer informatics to address the challenges posed by modern cancer clinical trials. This paper presents the service-oriented software paradigm implemented in CancerGrid to derive clinical trial information management systems for collaborative cancer research across multiple institutions. Our proposal is founded on a combination of a clinical trial (meta)model and WSRF (Web Services Resource Framework), and is currently being evaluated for use in early phase trials. Although primarily targeted at cancer research, our approach is readily applicable to other areas for which a similar information model is available.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The microbial contamination rate of luers of central venous catheters (CVCs) with either PosiFlow® needleless connectors or standard caps attached was investigated. The efficacy of 70% (v/v) isopropyl alcohol, 0.5% (w/v) chlorhexidine in gluconate 70% (v/v) isopropyl alcohol and 10% (w/v) aqueous povidone-iodine to disinfect the intravenous connections was also assessed. Seventy-seven patients undergoing cardiac surgery who required a CVC as part of their clinical management were randomly allocated either needleless connectors or standard caps. Patients were also designated to receive chlorhexidine/alcohol, isopropyl alcohol or povidone-iodine for pre-CVC insertion skin preparation and disinfection of the connections. After 72 h in situ the microbial contamination rate of 580 luers, 306 with standard caps and 274 with needleless connectors attached, was determined. The microbial contamination rate of the external compression seals of 274 needleless connectors was also assessed to compare the efficacy of the three disinfectants. The internal surfaces of 55 out of 306 (18%) luers with standard caps were contaminated with micro-organisms, whilst only 18 out of 274 (6.6%) luers with needleless connectors were contaminated (P<0.0001). Of those needleless connectors disinfected with isopropyl alcohol, 69.2% were externally contaminated with micro-organisms compared with 30.8% disinfected with chlorhexidine/alcohol (P<0.0001) and 41.6% with povidone-iodine (P<0.0001). These results suggest that the use of needleless connectors may reduce the microbial contamination rate of CVC luers compared with the standard cap. Furthermore, disinfection of needleless connectors with either chlorhexidine/alcohol or povidone-iodine significantly reduced external microbial contamination. Both these strategies may reduce the risk of catheter-related infections acquired via the intraluminal route. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Needleless connectors are being increasingly used for direct access to intravascular catheters. However, the potential for microbial contamination of these devices and subsequent infection risk is still widely debated. In this study the microbial contamination rate associated with three-way stopcock luers with standard caps attached was compared to those with Y-type extension set luers with Clearlink® needleless connectors attached. Fifty patients undergoing cardiothoracic surgery who required a central venous catheter (CVC) as part of their peri- and postoperative management were studied for microbial contamination of CVC luers following 72 hrs in situ. Each patient's CVC was randomly designated to have either the three-way stopcocks with caps (control patients) or Clearlink® Y-type extension sets (test patients). Prior to, and following each manipulation of the three-way stopcock luers or Clearlink® devices, a 70% (v/v) isopropyl alcohol swab was used for disinfection of the connections. The microbial contamination of 393 luers, 200 with standard caps and 193 with Clearlink® attached, was determined. The internal surfaces of 20 of 200 (10%) three-way stopcock luers with standard caps were contaminated with micro-organisms whereas only one of 193 (0.5%) luers with Clearlink® attached was contaminated (P < 0.0001). These results demonstrate that the use of the Clearlink® device with a dedicated disinfection regimen reduces the internal microbial contamination rate of CVC luers compared with standard caps. The use of such needle-free devices may therefore reduce the intraluminal risk of catheter-related bloodstream infection and thereby supplement current preventive guidelines. © 2006 The Hospital Infection Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background/aims To investigate the efficacy and safety of the MGDRx EyeBag (The Eyebag Company, Halifax, UK) eyelid warming device. Methods Twenty-five patients with confirmed meibomian gland dysfunction (MGD)-related evaporative dry eye were enrolled into a randomised, single masked, contralateral clinical trial. Test eyes received a heated device; control eyes a non-heated device for 5 min twice a day for 2 weeks. Efficacy (ocular symptomology, noninvasive break-up time, lipid layer thickness, osmolarity, meibomian gland dropout and function) and safety (visual acuity, corneal topography, conjunctival hyperaemia and staining) measurements were taken at baseline and follow-up. Subsequent patient device usage and ocular comfort was ascertained at 6 months. Results Differences between test and control eyes at baseline were not statistically signi ficant for all measurements ( p>0.05). After 2 weeks, statistically significant improvements occurred in all efficacy measurements in test eyes ( p<0.05). Visual acuity and corneal topography were unaffected (p>0.05). All patients maintained higher ocular comfort after 6 months ( p<0.05), although the bene fit was greater in those who continued usage 1-8 times a month (p<0.001). Conclusions The MGDRx EyeBag is a safe and effective device for the treatment of MGD-related evaporative dry eye. Subjective benefit lasts at least 6 months, aided by occasional retreatment. Trial registration number NCT01870180.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and aims: Glucagon-like peptide-1 (GLP-1) receptor agonists improve islet function and delay gastric emptying in subjects with type 2 diabetes mellitus. We evaluated 2-hour glucose, glucagon and insulin changes following a standardized mixed-meal tolerance test before and after 24 weeks of treatment with the once-daily prandial GLP-1 receptor agonist lixisenatide (approved for a therapeutic dose of 20 μg once daily) in six randomized, placebo-controlled studies within the lixisenatide Phase III GetGoal programme. In the studies, the mixed-meal test was conducted before and after: (1) lixisenatide treatment in patients insufficiently controlled despite diet and exercise (GetGoal-Mono), (2) lixisenatide treatment in combination with oral antidiabetic drugs (OADs) (GetGoal-M and GetGoal-S), or (3) lixisenatide treatment in combination with basal insulin ± OAD (GetGoal-Duo 1, GetGoal-L and GetGoal-L-Asia).Materials and methods: A meta-analysis was performed (lixisenatide n=1124 vs placebo n=707) combining ANCOVA least squares (LS) mean values using an inverse variance weighted analysis. Results: Lixisenatide significantly reduced 2-hour postprandial glucose from baseline (LS mean difference vs placebo: -4.9 mmol/L, p<0.0001, Figure) and glucose excursions (LS mean difference vs placebo: -4.5 mmol/L, p<0.0001). As measured in two studies, lixisenatide also reduced postprandial glucagon (LS mean difference vs placebo: -19.0 ng/L, p<0.0001) and insulin (LS mean difference vs placebo: -64.8 pmol/L, p<0.0001), although the glucagon/insulin ratio was increased (LS mean difference vs placebo: 0.15, p=0.02) compared with placebo. Conclusion: The results show that lixisenatide potently reduces the glucose excursion after meal ingestion in subjects with type 2 diabetes, in association with marked reductions in glucagon and insulin levels. It is suggested that diminished glucagon secretion and slower gastric emptying contribute to reduced hepatic glucose production and delayed glucose absorption, enabling postprandial glycaemia to be controlled with less demand on beta-cell insulin secretion. Clinical Trial Registration Number: NCT00688701; NCT00712673; NCT00713830; NCT00975286; NCT00715624; NCT00866658 Supported by: Sanofi

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This thesis sets out to examine in detail the condition of systemic hypertension (high Blood Pressure) in relation to optometric practice in the United Kingdom. Systemic hypertension, which is asymptomatic in the early stages, is diagnosed from the Blood Pressure (BP) measurement recorded by a sphygmomanometer and/or from the complications that have developed in target organs. Optometric practice based surveys revealed that diagnosed systemic hypertension was the most prevalent cardiovascular medical condition (20.5%). Measurement of BP of patients in this sample revealed that if an optometrist included sphygmomanometry into the sight examination then at least one patient each day would be referred for suspect systemic hypertension. Optometric opinion felt that the measurement of BP in optometric practice would advance the profession, being appreciated by both patients and General Practitioners (GPs), but was felt to be an unnecessary routine procedure. The present sight examination for the systemic hypertensive is similar to that of the normotensive patient, but may involve an altered fundus examination and a visual field test. The GPs were in favour of optometric BP measurement and a future role in the share care management of the systemic hypertensive. The application of a new pictorial grading scale for the grading of vascular changes associated with pre-malignant systemic hypertension was found to be both accurate and reliable. Clinical trial of the grading scale in optometric practice found positive correlations between BP and increasing severity of the retinal vascular features. The subtle pre-malignant vascular changes require reliable accurate detection and analysis to assist in the management of the systemic hypertensive patient. Vessel width was shown to decrease with increasing age. Image analysis of the A/V ratio, arteriolar tortuosity and focal calibre changes revealed a positive correlation to the patient's BP (p<0.001). The retinal vasculature is relatively stable longitudinally with only minor changes in response to early disease states. Age and elevated BP increased a patient's risk of developing systemic medical conditions over a two-year period. The application of the pictorial grading scale to optometric practice and training the optometrist in the use of sphygmomanometry would improve the management of the systemic hypertensive patient in optometric practice. Future advances in image analysis hold substantial benefits for the detection and monitoring of subtle vascular changes associated with systemic hypertension.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Management of type 2 diabetes with metformin often does not provide adequate glycemic control, thereby necessitating add-on treatment. In a 24-week clinical trial, dapagliflozin, an investigational sodium glucose cotransporter 2 inhibitor, improved glycemic control in patients inadequately controlled with metformin. The present study is an extension that was undertaken to evaluate dapagliflozin as long-term therapy in this population.Methods: This was a long-term extension (total 102 weeks) of a 24-week phase 3, multicenter, randomized, placebo-controlled, double-blind, parallel-group trial. Patients were randomly assigned (1:1:1:1) to blinded daily treatment (placebo, or dapagliflozin 2.5 to 5, or 10 mg) plus open-label metformin (=1,500 mg). The previously published primary endpoint was change from baseline in glycated hemoglobin (HbA1c) at 24 weeks. This paper reports the follow-up to week 102, with analysis of covariance model performed at 24 weeks with last observation carried forward; a repeated measures analysis was utilized to evaluate changes from baseline in HbA1c, fasting plasma glucose (FPG), and weight.Results: A total of 546 patients were randomized to 1 of the 4 treatments. The completion rate for the 78-week double-blind extension period was lower for the placebo group (63.5%) than for the dapagliflozin groups (68.3% to 79.8%). At week 102, mean changes from baseline HbA1c (8.06%) were +0.02% for placebo compared with -0.48% (P = 0.0008), -0.58% (P

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To describe changes in intraocular pressure (IOP) in the 'alternative treatments to Inhibit VEGF in Age-related choroidal Neovascularisation (IVAN)' trial (registered as ISRCTN92166560). DESIGN: Randomised controlled clinical trial with factorial design. PARTICIPANTS: Patients (n=610) with treatment naïve neovascular age-related macular degeneration were enrolled and randomly assigned to receive either ranibizumab or bevacizumab and to two regimens, namely monthly (continuous) or as needed (discontinuous) treatment. METHODS: At monthly visits, IOP was measured preinjection in both eyes, and postinjection in the study eye. OUTCOME MEASURES: The effects of 10 prespecified covariates on preinjection IOP, change in IOP (postinjection minus preinjection) and the difference in preinjection IOP between the two eyes were examined. RESULTS: For every month in trial, there was a statistically significant rise in both the preinjection IOP and the change in IOP postinjection during the time in the trial (estimate 0.02 mm Hg, 95% CI 0.01 to 0.03, p<0.001 and 0.03 mm Hg, 95% CI 0.01 to 0.04, p=0.002, respectively). There was also a small but significant increase during the time in trial in the difference in IOP between the two eyes (estimate 0.01 mm Hg, 95% CI 0.005 to 0.02, p<0.001). There were no differences between bevacizumab and ranibizumab for any of the three outcomes (p=0.93, p=0.22 and p=0.87, respectively). CONCLUSIONS: Anti-vascular endothelial growth factor agents induce increases in IOP of small and uncertain clinical significance.