9 resultados para Capacitor eletrolítico de nióbio
em Aston University Research Archive
Resumo:
DC distribution and transmission provides an efficient, cost effective and reliable alternative to traditional AC systems for offshore wind farm integration. High power DC-DC converters are key components to realise future offshore voltage DC grids and multi-terminal HVDC systems. Different DC-DC converter topologies have been proposed for this application. The aim of this paper is to investigate the viability of Switched Capacitor (SC) converters in high power application particularly the interconnection of offshore windfarms to a medium voltage DC grid. In addition, a comparison of alternative topologies that have been proposed will be presented. Simulation and experimental results are provided to verify the analysis.
Resumo:
Switched Capacitor (SC) converters have been used for several years in low-power, power electronic energy conversion systems. However, because of their attractive features such as low-weight and high-density energy conversion and with the emergence of new circuit topologies and SiC switching devices, these circuits have recently been proposed for higher power applications. The resonant switched capacitor topology is a good candidate for high-power due to its very low-switching loss, but circuit parasitic inductance and resistance can have a significant effect on the resonant frequency of each cell. This paper discusses the influence of these parasitics on the performance of the converter and proposes a method by which these parasitics can be estimated. Simulation results and measurements from a hardware prototype are used to validate the technique.
Resumo:
There is an increase in the use of multi-pulse, rectifier-fed motor-drive equipment on board more-electric aircraft. Motor drives with feedback control appear as constant power loads to the rectifiers, which can cause instability of the DC filter capacitor voltage at the output of the rectifier. This problem can be exacerbated by interactions between rectifiers that share a common source impedance. In order that such a system can be analysed, there is a need for average, dynamic models of systems of rectifiers. In this study, an efficient, compact method for deriving the approximate, linear, large-signal, average models of two heterogeneous systems of rectifiers, which are fed from a common source impedance, is presented. The models give insight into significant interaction effects that occur between the converters, and that arise through the shared source impedance. First, a 6-pulse and doubly wound, transformer-fed, 12-pulse rectifier system is considered, followed by a 6-pulse and autotransformer-fed, 12-pulse rectifier system. The system models are validated against detailed simulations and laboratory prototypes, and key characteristics of the two system types are compared.
Resumo:
Cascaded multilevel inverters-based Static Var Generators (SVGs) are FACTS equipment introduced for active and reactive power flow control. They eliminate the need for zigzag transformers and give a fast response. However, with regard to their application for flicker reduction in using Electric Arc Furnace (EAF), the existing multilevel inverter-based SVGs suffer from the following disadvantages. (1) To control the reactive power, an off-line calculation of Modulation Index (MI) is required to adjust the SVG output voltage. This slows down the transient response to the changes of reactive power; and (2) Random active power exchange may cause unbalance to the voltage of the d.c. link (HBI) capacitor when the reactive power control is done by adjusting the power angle d alone. To resolve these problems, a mathematical model of 11-level cascaded SVG, was developed. A new control strategy involving both MI (modulation index) and power angle (d) is proposed. A selected harmonics elimination method (SHEM) is taken for switching pattern calculations. To shorten the response time and simplify the controls system, feed forward neural networks are used for on-line computation of the switching patterns instead of using look-up tables. The proposed controller updates the MI and switching patterns once each line-cycle according to the sampled reactive power Qs. Meanwhile, the remainder reactive power (compensated by the MI) and the reactive power variations during the line-cycle will be continuously compensated by adjusting the power angles, d. The scheme senses both variables MI and d, and takes action through the inverter switching angle, qi. As a result, the proposed SVG is expected to give a faster and more accurate response than present designs allow. In support of the proposal there is a mathematical model for reactive powered distribution and a sensitivity matrix for voltage regulation assessment, MATLAB simulation results are provided to validate the proposed schemes. The performance with non-linear time varying loads is analysed and refers to a general review of flicker, of methods for measuring flickers due to arc furnace and means for mitigation.
Resumo:
As a source or sink of reactive power, compensators can be made from a voltage sourced inverter circuit with the a.c. terminals of the inverter connected to the system through an inductive link and with a capacitor connected across the d.c. terminals. Theoretical calculations on linearised models of the compensators have shown that the parameters characterising the performance are the reduced firing angle and the resonance ratio. The resonance ratio is the ratio of the natural frequency of oscillation of the energy storage components in the circuit to the system frequency. The reduced firing angle of the inverter divided by the damping coefficient, β, where β is half the R to X ratio of the link between the inverter and the system. The theoretical results have been verified by computer simulation and experiment. There is a narrow range of values for the resonance ratio below which there is no appreciable improvement in performance, despite an increase in the cost of the energy storage components, and above which the performance of the equipment is poor with the current being dominated by harmonics. The harmonic performance of the equipment is improved by using multiple inverters and phase shifting transformers to increase the pulse number. The optimum value of the resonance ratio increases pulse number, indicating a reduction in the energy storage components needed at high pulse numbers. The reactive power output from the compensator varies linearly with the reduced firing angle while the losses vary as the square of it.
Resumo:
There are several methods of providing series compensation for transmission lines using power electronic switches. Four methods of series compensation have been examined in this thesis, the thyristor controlled series capacitor, a voltage sourced inverter series compensator using a capacitor as the series element, a current sourced inverter series compensator and a voltage sourced inverter using an inductor as the series element. All the compensators examined will provide a continuously variable series voltage which is controlled by the switching of the electronic switches. Two of the circuits will offer both capacitive and inductive compensation, the thyristor controlled series capacitor and the current sourced inverter series compensator. The other two will produce either capacitive or inductive series compensation. The thyristor controlled series capacitor offers the widest range of series compensation. However, there is a band of unavailable compensation between 0 and 1 pu capacitive compensation. Compared to the other compensators examined the harmonic content of the compensating voltage is quite high. An algebraic analysis showed that there is more than one state the thyristor controlled series capacitor can operate in. This state has the undesirable effect of introducing large losses. The voltage sourced inverter series compensator using a capacitor as the series element will provide only capacitive compensation. It uses two capacitors which increase the cost of the compensator significantly above the other three. This circuit has the advantage of very low harmonic distortion. The current sourced inverter series compensator will provide both capacitive and inductive series compensation. The harmonic content of the compensating voltage is second only to the voltage sourced inverter series compensator using a capacitor as the series element. The voltage sourced inverter series compensator using an inductor as the series element will only provide inductive compensation, and it is the least expensive compensator examined. Unfortunately, the harmonics introduced by this circuit are considerable.
Resumo:
Electrolytic capacitors are extensively used in power converters but they are bulky, unreliable, and have short lifetimes. This paper proposes a new capacitor-free high step-up dc-dc converter design for renewable energy applications such as photovoltaics (PVs) and fuel cells. The primary side of the converter includes three interleaved inductors, three main switches, and an active clamp circuit. As a result, the input current ripple is greatly reduced, eliminating the necessity for an input capacitor. In addition, zero voltage switching (ZVS) is achieved during switching transitions for all active switches, so that switching losses can be greatly reduced. Furthermore, a three-phase modular structure and six pulse rectifiers are employed to reduce the output voltage ripple. Since magnetic energy stored in the leakage inductance is recovered, the reverse-recovery issue of the diodes is effectively solved. The proposed converter is justified by simulation and experimental tests on a 1-kW prototype.
Resumo:
This paper presents an integrated multilevel converter of switched reluctance motors (SRMs) fed by a modular front-end circuit for plug-in hybrid electric vehicle (PHEV) applications. Several operating modes can be achieved by changing the on-off states of the switches in the front-end circuit. In generator driving mode, the battery bank is employed to elevate the phase voltage for fast excitation and demagnetization. In battery driving mode, the converter is reconfigured as a four-level converter, and the capacitor is used as an additional charge capacitor to produce multilevel voltage outputs, which enhances the torque capability. The operating modes of the proposed drive are explained and the phase current and voltage are analyzed in details. The battery charging is naturally achieved by the demagnetization current in motoring mode and by the regenerative current in braking mode. Moreover, the battery can be charged by the external AC source or generator through the proposed converter when the vehicle is in standstill condition. The SRM-based PHEV can operate at different speeds by coordinating the power flow between the generator and battery. Simulation in MATLAB/Simulink and experiments on a three-phase 12/8 SRM confirm the effectiveness of the proposed converter topology.
Resumo:
A novel open-winding brushless doubly-fed generator (BDFG) system with two two-level bidirectional converters is proposed. This topology is equivalent to a three-level bidirectional converter connected to the typical BDFG, but solves the unbalanced-voltage-division problem of DC capacitor in the three-level converter, and has lower converter capacity, more flexible control mode, and better fault-tolerant ability. The direct power control (DPC) based on the twelve sections is adopted to implement the power tracking of the open-winding BDFG system, which is compared with the typical BDFG DPC system based on the six and twelve sections to verify the advantages of the proposed scheme.