5 resultados para CAPS

em Aston University Research Archive


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Regulation is subject to information asymmetries that can lead to allocative and productive inefficiencies. One solution, suggested by Shleifer in 1985 and now adopted by many regulatory bodies round the world, is 'benchmarking', which is sometimes called 'yardstick competition'. In this paper we consider Shleifer's original approach to benchmarking and contrast this with the actual use of benchmarking by UK regulatory bodies in telecommunications, water and the energy sector since the privatizations of the 1980s and early 1990s. We find that benchmarking plays only one part and sometimes a small part in the setting of regulatory price caps in the UK. We also find that in practice benchmarking has been subject to a number of difficulties, which mean that it is never likely to be more than one tool in the regulator's armoury. The UK's experience provides lessons for regulation internationally. © 2006 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study we apply an index number approach to allow for cross sectional comparisons of relative profitability, productivity and price performance of the regulated Water and Sewerage companies (WaSCs) in England and Wales during the years 1991-2008. In order to better analyse the impact of regulation on WaSC performance, we decompose actual economic profits into spatial multilateral Fisher productivity (TFP) index, the inverse of which is demonstrated to be a regulatory excess cost index that measures the deviation of a firm’s actual costs from benchmark costs, and a newly developed regulatory total price performance (TPP) index, which measures the excess of regulated revenues relative to benchmark costs. Increases (decreases) in regulatory price performance are indicative of the loosening (tightening) of price cap regulation. Moreover, we also show that the relationship between actual economic profitability, regulatory excess costs and regulatory price performance indices can be used to categorize regulatory price caps as “weak”, “powerful” or “catch-up promoting”. The results indicated that throughout the entire 1991-2008 period, price caps were never “powerful”, in the sense that they required less productive firms to immediately and fully catch-up to the most productive firm to regain economic profitability. More specifically, during the years 1991-2000 price caps were “weak” as prices were high enough for the firms to achieve economic profits despite their low productivity levels. However, after 2001 prices became “catch up promoting” as they required less productive companies to eliminate at least some excess costs in order to eliminate economic losses. Finally, we emphasize that as our results also clearly demonstrated a much closer alignment between allowed revenues and benchmark costs after 2001, Ofwat’s approach during this period was not only appropriate, but should also be continued in the 2009 price review.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The microbial contamination rate of luers of central venous catheters (CVCs) with either PosiFlow® needleless connectors or standard caps attached was investigated. The efficacy of 70% (v/v) isopropyl alcohol, 0.5% (w/v) chlorhexidine in gluconate 70% (v/v) isopropyl alcohol and 10% (w/v) aqueous povidone-iodine to disinfect the intravenous connections was also assessed. Seventy-seven patients undergoing cardiac surgery who required a CVC as part of their clinical management were randomly allocated either needleless connectors or standard caps. Patients were also designated to receive chlorhexidine/alcohol, isopropyl alcohol or povidone-iodine for pre-CVC insertion skin preparation and disinfection of the connections. After 72 h in situ the microbial contamination rate of 580 luers, 306 with standard caps and 274 with needleless connectors attached, was determined. The microbial contamination rate of the external compression seals of 274 needleless connectors was also assessed to compare the efficacy of the three disinfectants. The internal surfaces of 55 out of 306 (18%) luers with standard caps were contaminated with micro-organisms, whilst only 18 out of 274 (6.6%) luers with needleless connectors were contaminated (P<0.0001). Of those needleless connectors disinfected with isopropyl alcohol, 69.2% were externally contaminated with micro-organisms compared with 30.8% disinfected with chlorhexidine/alcohol (P<0.0001) and 41.6% with povidone-iodine (P<0.0001). These results suggest that the use of needleless connectors may reduce the microbial contamination rate of CVC luers compared with the standard cap. Furthermore, disinfection of needleless connectors with either chlorhexidine/alcohol or povidone-iodine significantly reduced external microbial contamination. Both these strategies may reduce the risk of catheter-related infections acquired via the intraluminal route. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Needleless connectors are being increasingly used for direct access to intravascular catheters. However, the potential for microbial contamination of these devices and subsequent infection risk is still widely debated. In this study the microbial contamination rate associated with three-way stopcock luers with standard caps attached was compared to those with Y-type extension set luers with Clearlink® needleless connectors attached. Fifty patients undergoing cardiothoracic surgery who required a central venous catheter (CVC) as part of their peri- and postoperative management were studied for microbial contamination of CVC luers following 72 hrs in situ. Each patient's CVC was randomly designated to have either the three-way stopcocks with caps (control patients) or Clearlink® Y-type extension sets (test patients). Prior to, and following each manipulation of the three-way stopcock luers or Clearlink® devices, a 70% (v/v) isopropyl alcohol swab was used for disinfection of the connections. The microbial contamination of 393 luers, 200 with standard caps and 193 with Clearlink® attached, was determined. The internal surfaces of 20 of 200 (10%) three-way stopcock luers with standard caps were contaminated with micro-organisms whereas only one of 193 (0.5%) luers with Clearlink® attached was contaminated (P < 0.0001). These results demonstrate that the use of the Clearlink® device with a dedicated disinfection regimen reduces the internal microbial contamination rate of CVC luers compared with standard caps. The use of such needle-free devices may therefore reduce the intraluminal risk of catheter-related bloodstream infection and thereby supplement current preventive guidelines. © 2006 The Hospital Infection Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper will explore a data-driven approach called Sales Resource Management (SRM) that can provide real insight into sales management. The DSMT (Diagnosis, Strategy, Metrics and Tools) framework can be used to solve field sales management challenges. This paper focus on the 6P's strategy of SRM and illustrates how to use them to solve the CAPS (Concentration, Attrition, Performance and Spend) challenges. © 2010 IEEE.