3 resultados para Bone density
em Aston University Research Archive
Resumo:
Whole body vibration treatment is a non-pharmacological intervention intended to stimulate muscular response and increase bone mineral density, particularly for postmenopausal women. The literature related to this topic is controversial, heterogeneous, and unclear despite the prospect of a major clinical effect. The aim of this study was to identify and systematically review the literature to assess the effect of whole body vibration treatments on bone mineral density (BMD) in postmenopausal women with a specific focus on the experimental factors that influence the stimulus. Nine studies fulfilled the inclusion criteria, including 527 postmenopausal women and different vibration delivery designs. Cumulative dose, amplitudes and frequency of treatments as well as subject posture during treatment vary widely among studies. Some of the studies included an associated exercise training regime. Both randomized and controlled clinical trials were included. Whole body vibration was shown to produce significant BMD improvements on the hip and spine when compared to no intervention. Conversely, treatment associated with exercise training resulted in negligible outcomes when compared to exercise training or to placebo. Moreover, side-alternating platforms were more effective in improving BMD values than synchronous platforms and mechanical oscillations of magnitude higher than 3 g and/or frequency lower than 25 Hz were also found to be effective. Treatments with a cumulative dose over 1000 minutes in the follow-up period were correlated to positive outcomes. Our conclusion is that whole body vibration treatments in elderly women can reduce BMD decline.However, many factors (e.g. amplitude, frequency and subject posture) affect the capacity of the vibrations to propagate to the target site; the adequate level of stimulation required to produce these effects has not yet been defined. Further biomechanical analyses to predict the propagation of the vibration waves along the body and assess the stimulation levels are required.
Resumo:
Background: Electrosurgery units are widely employed in modern surgery. Advances in technology have enhanced the safety of these devices, nevertheless, accidental burns are still regularly reported. This study focuses on possible causes of sacral burns as complication of the use of electrosurgery. Burns are caused by local densifications of the current, but the actual pathway of current within patient's body is unknown. Numerical electromagnetic analysis can help in understanding the issue. Methods: To this aim, an accurate heterogeneous model of human body (including seventy-seven different tissues), electrosurgery electrodes, operating table and mattress was build to resemble a typical surgery condition. The patient lays supine on the mattress with the active electrode placed onto the thorax and the return electrode on his back. Common operating frequencies of electrosurgery units were considered. Finite Difference Time Domain electromagnetic analysis was carried out to compute the spatial distribution of current density within the patient's body. A differential analysis by changing the electrical properties of the operating table from a conductor to an insulator was also performed. Results: Results revealed that distributed capacitive coupling between patient body and the conductive operating table offers an alternative path to the electrosurgery current. The patient's anatomy, the positioning and the different electromagnetic properties of tissues promote a densification of the current at the head and sacral region. In particular, high values of current density were located behind the sacral bone and beneath the skin. This did not occur in the case of non-conductive operating table. Conclusion: Results of the simulation highlight the role played from capacitive couplings between the return electrode and the conductive operating table. The concentration of current density may result in an undesired rise in temperature, originating burns in body region far from the electrodes. This outcome is concordant with the type of surgery-related sacral burns reported in literature. Such burns cannot be immediately detected after surgery, but appear later and can be confused with bedsores. In addition, the dosimetric analysis suggests that reducing the capacity coupling between the return electrode and the operating table can decrease or avoid this problem. © 2013 Bifulco et al.; licensee BioMed Central Ltd.
Resumo:
Poster. Introduction: One in five menand one half of women over the age of 50 will experience a bone fracture, whichis frequently accompanied by poor bone health. This combination of poor bonehealth and fracture is a two edge sword, because not only does poor bone healthmake fractures more likely, it also reduces the efficacy of standard fracturetreatments. Currently available surgical fixation devices that were originallydeveloped for healthy bone, such as pins, plates and bone screws, are often noteffective for patients with osteoporosis, resulting in unsatisfactory outcomesor longer and more painful recovery times. One major issue is the design ofbone screws, which can loosen or pull-out from osteoporotic bone. Osteopenicscrews with larger outer thread diameters have been developed to try andaddress this problem. The larger diameter screws have been shown to be 60–70 %stronger in lab tests of individual screws but the larger diameter screwscannot be used with the standard spacing in fixation plates without the risk ofcausing fractures between the screws. In addition, many fractures occur nearjoints where there is not room to increase the spacing between screws.Therefore, new bone screws are needed for treatment of fractures in osteoporoticbone. Materials and Methods: Afterdeveloping a novel bone screw design, we fabricated screws using rapidprototyping methods. Screws were inserted into 10 pcf density sawbones polyurethanefoam as a model for osteoporotic bone. Pull-out tests were conducted using theprototype bone screw design and the standard screw design for comparison inaccordance with ASTM 543-13. Results and Discussion: Ourprototype screws have the same outer diameter as standard bone screws, but haveoptimised threads. For pull-out tests in 10 psf density sawbones poly-urethanefoam, the prototype screw design was 60 % stronger than the standard bone screwdesign (p<0.01). Conclusion: Our novel bonescrew design provides significant improvement in standard tests with syntheticbone material. Additional tests are needed to determine if the bone screwswould be suitable for human trials.