10 resultados para Bilateral osteoradionecrosis
em Aston University Research Archive
Resumo:
The authors investigate channel incentives as extra-contractual governance processes that maintain and extend marketing channel relationships. More specifically, instrumental incentives are monetary-based payments made by a manufacturer in a unilateral channel arrangement to motivate distributor compliance, while equity incentives are bilateral expectations of fair treatment that motivate both parties to continue to cooperate with one another. A model of the antecedents and performance consequences of channel incentives is conceptualized and tested on 314 marketing channel relationships using a structural equation modeling methodology. The findings support the conceptual model and suggest that unique facets of the channel relationship explain the type of incentive mechanism in use.
Resumo:
Purpose - To assess clinical outcomes and subjective experience after bilateral implantation of a diffractive trifocal intraocular lens (IOL). Setting - Midland Eye Institute, Solihull, United Kingdom. Design - Cohort study. Methods - Patients had bilateral implantation of Finevision trifocal IOLs. Uncorrected distance visual acuity, corrected distance visual acuity (CDVA), and manifest refraction were measured 2 months postoperatively. Defocus curves were assessed under photopic and mesopic conditions over a range of +1.50 to -4.00 diopters (D) in 0.50 D steps. Contrast sensitivity function was assessed under photopic conditions. Halometry was used to measure the angular size of monocular and binocular photopic scotomas arising from a glare source. Patient satisfaction with uncorrected near vision was assessed using the Near Activity Visual Questionnaire (NAVQ). Results - The mean monocular CDVA was 0.08 logMAR ± 0.08 (SD) and the mean binocular CDVA, 0.06 ± 0.08 logMAR. Defocus curve testing showed an extended range of clear vision from +1.00 to -2.50 D defocus, with a significant difference in acuity between photopic conditions and mesopic conditions at -1.50 D defocus only. Photopic contrast sensitivity was significantly better binocularly than monocularly at all spatial frequencies. Halometry showed a glare scotoma of a mean size similar to that in previous studies of multifocal and accommodating IOLs; there were no subjective complaints of dysphotopsia. The mean NAVQ Rasch score for satisfaction with near vision was 15.9 ± 10.7 logits. Conclusions - The trifocal IOL implanted binocularly produced good distance visual acuity and near and intermediate visual function. Patients were very satisfied with their uncorrected near vision.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
Whereas there are numerous reported ocular side effects from systemic sulpha medication, most are rare and reversible, with myopia being the most common reaction observed. A case report is presented of sudden bilateral onset of -1.0 DS of myopia (from -3.0 to -4.0 DS) in a young adult female following the addition of a sulphonamide (sulphasalazine) to oral non-steroidal anti-inflammatory treatment (meloxicam) for rheumatoid arthritis. The myopia regressed to -3.50 DS after 2 weeks when all medication was withdrawn and stabilised at this level when subsequent treatment was resumed after 8 weeks with the non-steroidal anti-inflammatory drug celecoxib. The case indicates that account needs to be taken of the possibility that relatively modest myopic shifts encountered in young adult contact lens wearers may be associated with concomitant systemic medication. © 2003 The College of Optometrists.
Resumo:
In France, the tradition of contracting out local public services has been predominantly one of partnership and co-operation rather than competition and antagonism. However, in recent years the traditional approach has come under intense criticism, something which has far-reaching implications for public-private governance. Adopting the socio-legal approach to the study of contract governance set out by Peter Vincent-Jones, this paper explores the discrepancy between descriptions of a traditional French approach to local public services governance, in which the bilateral values of trust and co-operation are emphasized, and a new discourse of local public services governance, which argues for detailed contract planning and close contract monitoring. It is argued that this discrepancy reveals the beginning of a shift in the governance of public service exchange relationships from relatively noncontractual and bilateral to relatively contractual and trilateral. The French case highlights the importance of regulatory and accountability frameworks to the manner in which contracting parties perceive exchange governance. © Blackwell Publishing Ltd. 2005.
Resumo:
Background: The aim of this study was to describe bilateral visual outcomes and the effect of incomplete follow-up after 3 years of ranibizumab therapy for neovascular age-related macular degeneration. Secondarily, the demands on service provision over a 3-year period were described. Methods: Data on visual acuity, hospital visits, and injections were collected over 36 months on consecutive patients commencing treatment over a 9-month period. Visual outcome was determined for 1) all patients, using last observation carried forward for missed visits due to early discontinuation and 2) only those patients completing full 36-month follow-up. Results: Over 3 years, 120 patients cumulatively attended hospital for 1,823 noninjection visits and 1,365 injection visits. A visual acuity loss of <15 letters (L) was experienced by 78.2% of patients. For all patients (n=120), there was a mean loss of 1.68 L using last observation carried forward for missing values. Excluding five patients who died and 30 who discontinued follow-up, mean gain was 1.47 L. In bilateral cases, final acuity was on average 9 L better in second eyes compared to first eyes. Also, 91% of better-seeing eyes continued to be the better-seeing eye. Conclusion: We have demonstrated our approach to describing the long-term service provision and visual outcomes of ranibizumab therapy for neovascular age-related macular degeneration in a consecutive cohort of patients. Although there was a heavy burden with very frequent injections and clinic visits, patients can expect a good level of visual stability and a very high chance of maintaining their better-seeing eye for up to 3 years. © 2014 Chavan et al. This work is published by Dove Medical Press Limited.
Resumo:
Purpose: To examine visual outcomes following bilateral implantation of the FineVision trifocal intraocular lens (IOL; PhysIOL, Liège, Belgium). Methods: 26 patients undergoing routine cataract surgery were implanted bilaterally with the FineVision Trifocal IOL and followed up post-operatively for 3 months. The FineVision optic features a combination of 2 diffractive structures, resulting in distance, intermediate (+1.75 D add) and near vision (+3.50 D add) zones. Apodization of the optic surface increases far vision dominance with pupil aperture. Data collected at the 3 month visit included uncorrected and corrected distance (CDVA) and near vision; subjective refraction; defocus curve testing (photopic and mesopic); contrast sensitivity (CSV-1000); halometry glare testing and a questionnaire (NAVQ) to gauge near vision function and patient satisfaction. Results: The cohort comprised 15 males and 11 females, aged 52.5–82.4 years (mean 70.6 ± 8.2 years). Mean post-operative UDVA was 0.22 ± 0.14 logMAR, with a mean spherical equivalent refraction of +0.02 ± 0.35 D. Mean CDVA was 0.13 ± 0.10 logMAR monocularly, and 0.09 ± 0.07 logMAR binocularly. Defocus curve testing showed an extensive range of clear vision in both photopic and mesopic conditions. Patients showed high levels of satisfaction with their near vision (mean ± 0.9 ± 0.6, where 0 = completely satisfied, and 4 = completely unsatisfied) and demonstrated good spectacle independence. Conclusion: The FineVision IOL can be considered in patients seeking spectacle dependence following cataract surgery, and provide good patient satisfaction with uncorrected vision.
Resumo:
Bilateral Perisylvian Syndrome (BPS) often presents with epilepsy and significant behavioral impairments that can include mental retardation, dysarthria, delayed speech development, and delayed fine motor development (Graff-Radford et al., 1986 and Kuzniecky et al., 1993). While a small subset of BPS cases have been described as having relatively isolated language delays (Leventer et al., 2010), BPS is not expected in children with dyslexia. As part of a Medical University of South Carolina, IRB approved multi-site study involving retrospective and de-identified dyslexia data, we unexpectedly identified a 14.05 year old male with evidence of BPS whose father had been diagnosed with dyslexia and dysgraphia. This child had been recruited for a neuroimaging study on dyslexia from a school specializing in educating children with dyslexia. The T1-weighted MRI scan from this child demonstrated a highly unusual perisylvian sulcal/gyral patterning that is a defining feature of BPS (Fig. 1). BPS cases exhibit bilateral dysgenesis of the Sylvian fissure and surrounding gyri, which appears to occur because of a limited or absent arcuate fasciculus (Kilinc, Ekinci, Demirkol, & Agan, 2015). This BPS case also had a relatively enlarged atrium of the lateral ventricle that is consistent with the BPS anatomical presentation and reduction of parietal white matter (Graff-Radford et al., 1986, Kilinc et al., 2015 and Toldo et al., 2011).
Resumo:
The auditory evoked N1m-P2m response complex presents a challenging case for MEG source-modelling, because symmetrical, phase-locked activity occurs in the hemispheres both contralateral and ipsilateral to stimulation. Beamformer methods, in particular, can be susceptible to localisation bias and spurious sources under these conditions. This study explored the accuracy and efficiency of event-related beamformer source models for auditory MEG data under typical experimental conditions: monaural and diotic stimulation; and whole-head beamformer analysis compared to a half-head analysis using only sensors from the hemisphere contralateral to stimulation. Event-related beamformer localisations were also compared with more traditional single-dipole models. At the group level, the event-related beamformer performed equally well as the single-dipole models in terms of accuracy for both the N1m and the P2m, and in terms of efficiency (number of successful source models) for the N1m. The results yielded by the half-head analysis did not differ significantly from those produced by the traditional whole-head analysis. Any localisation bias caused by the presence of correlated sources is minimal in the context of the inter-individual variability in source localisations. In conclusion, event-related beamformers provide a useful alternative to equivalent-current dipole models in localisation of auditory evoked responses.
Resumo:
OBJECTIVE: This study aimed to assess prevalence and risk factors for mild/high-frequency bilateral sensorineural hearing loss within a UK population of children at age 11 years. DESIGN: Prospective birth cohort study. STUDY SAMPLE: Repeat hearing thresholds were measured in 5032 children, as part of the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 7, 9, and 11 years. Pregnancy, birth, and early medical history were obtained prospectively through parental questionnaires and medical records. RESULTS: Twenty children had mild and seven had high-frequency bilateral sensorineural hearing loss, giving a combined prevalence of 0.5% (95% CI 0.4-0.8%). These children were more likely than the rest of the study sample to have been admitted to hospital at 6-18 months (OR 2.7, 95% CI 1.00-7.30). Parents of these children were more likely to have suspected a hearing problem when the children were 3 years old (OR 2.4, 95% CI 1.05-5.60). CONCLUSIONS: This is the first UK prospective cohort study to investigate the prevalence of mild and high-frequency hearing loss. This study, which has the advantage of a large sample size and repeat hearing measures over a four year period, reports lower prevalence values than US cross-sectional studies.