6 resultados para Assessment Instruments
em Aston University Research Archive
Resumo:
This review compares the results of studies that have investigated the impact of lutein and zeaxanthin supplementation on macular pigment optical density (MPOD) with those that have investigated the reliability of techniques used to measure macular pigment optical density. The review will focus on studies that have used heterochromatic flicker photometry for measurement of macular pigment optical density, as this is the only technique that is currently available commercially to clinicians. We identified articles that reported on supplementation with lutein and/or zeaxanthin and/or meso-zeaxanthin on macular pigment optical density measurement techniques published in peer-reviewed journals, through a multi-staged, systematic approach. Twenty-four studies have investigated the repeatability of MPOD measurements using heterochromatic flicker photometry. Of these, 10 studies provided a coefficient of repeatability or data from which the coefficient could be calculated, with a range in values of 0.06 to 0.58. The lowest coefficient of repeatability assessed on naïve subjects alone was 0.08. These values tell us that, at best, changes greater than 0.08 can be considered clinically significant and at worst, only changes greater than 0.58 can be considered clinically significant. Six studies assessed the effect of supplementation with up to 20 mg/day lutein on macular pigment optical density measured using heterochromatic flicker photometry and the mean increase in macular pigment optical density ranged from 0.025 to 0.09. It seems reasonable to conclude that the chance of eliciting an increase in macular pigment optical density during six months of daily supplementation with between 10 and 20 mg lutein that is of sufficient magnitude to be detected by using heterochromatic flicker photometry on an individual basis is small. Commercially available heterochromatic flicker photometers for macular pigment optical density assessment in the clinical environment appear to demonstrate particularly poor coefficient of repeatability values. Clinicians should exercise caution when considering the purchase of these instruments for potential monitoring of macular pigment optical density in response to supplementation in individual patients.
Resumo:
BACKGROUND: The use of quality of life (QoL) instruments in menorrhagia research is increasing but there is concern that not enough emphasis is placed on patient-focus in these measurements, i.e. on issues which are of importance to patients and reflect their experiences and concerns (clinical face validity). The objective was to assess the quality of QoL instruments in studies of menorrhagia. STUDY DESIGN: A systematic review of published research. Papers were identified through MEDLINE (1966-April 2000), EMBASE (1980-April 2000), Science Citation Index (1981-April 2000), Social Science Citation Index (1981-April 2000), CINAHL (1982-1999) and PsychLIT (1966-1999), and by manual searching of bibliographies of known primary and review articles. Studies were selected if they assessed women with menorrhagia for life quality, either developing QoL instruments or applying them as an outcome measure. Selected studies were assessed for quality of their QoL instruments, using a 17 items checklist including 10 items for clinical face validity (issues of relevance to patients' expectations and concerns) and 7 items for measurement properties (such as reliability, responsiveness, etc.). RESULTS: A total of 19 articles, 8 on instrument development and 11 on application, were included in the review. The generic Short Form 36 Health Survey Questionnaire (SF36) was used in 12/19 (63%) studies. Only two studies developed new specific QoL instruments for menorrhagia but they complied with 7/17 (41%) and 10/17 (59%) of the quality criteria. Quality assessment showed that only 7/19 (37%) studies complied with more than half the criteria for face validity whereas 17/19 (90%) studies complied with more than half of the criteria for measurement properties (P = 0.0001). CONCLUSION: Among existing QoL instruments, there is good compliance with the quality criteria for measurement properties but not with those for clinical face validity. There is a need to develop methodologically sound disease specific QoL instruments in menorrhagia focussing both on face validity and measurement properties.
Resumo:
Healthcare providers and policy makers are faced with an ever-increasing number of medical publications. Searching for relevant information and keeping up to date with new research findings remains a constant challenge. It has been widely acknowledged that narrative reviews of the literature are susceptible to several types of bias and a systematic approach may protect against these biases. The aim of this thesis was to apply quantitative methods in the assessment of outcomes of topical therapies for psoriasis. In particular, to systematically examine the comparative efficacy, tolerability and cost-effectiveness of topical calcipotriol in the treatment of mild-to-moderate psoriasis. Over the years, a wide range of techniques have been used to evaluate the severity of psoriasis and the outcomes from treatment. This lack of standardisation complicates the direct comparison of results and ultimately the pooling of outcomes from different clinical trials. There is a clear requirement for more comprehensive tools for measuring drug efficacy and disease severity in psoriasis. Ideally, the outcome measures need to be simple, relevant, practical, and widely applicable, and the instruments should be reliable, valid and responsive. The results of the meta-analysis reported herein show that calcipotriol is an effective antipsoriatic agent. In the short-tenn, the pooled data found calcipotriol to be more effective than calcitriol, tacalcitol, coal tar and short-contact dithranol. Only potent corticosteroids appeared to have comparable efficacy, with less short-term side-effects. Potent corticosteroids also added to the antipsoriatic effect of calcipotriol, and appeared to suppress the occurrence of calcipotriol-induced irritation. There was insufficient evidence to support any large effects in favour of improvements in efficacy when calcipotriol is used in combination with systemic therapies in patients with severe psoriasis. However, there was a total absence of long-term morbidity data on the effectiveness of any of the interventions studied. Decision analysis showed that, from the perspective of the NHS as payer, the relatively small differences in efficacy between calcipotriol and short-contact dithranol lead to large differences in the direct cost of treating patients with mildto-moderate plaque psoriasis. Further research is needed to examine the clinical and economic issues affecting patients under treatment for psoriasis in the UK. In particular, the maintenance value and cost/benefit ratio for the various treatment strategies, and the assessment of patient's preferences has not yet been adequately addressed for this chronic recurring disease.
Resumo:
The work present in this thesis was aimed at assessing the efficacy of lithium in the acute treatment of mania and for the prophylaxis of bipolar disorder, and investigating the value of plasma haloperidol concentration for predicting response to treatment in schizophrenia. The pharmacogenetics of psychotropic drugs is critically appraised to provide insights into interindividual variability in response to pharmacotherapy, In clinical trials of acute mania, a number of measures have been used to assess the severity of illness and its response to treatment. Rating instruments need to be validated in order for a clinical study to provide reliable and meaningful estimates of treatment effects, Eight symptom-rating scales were identified and critically assessed, The Mania Rating Scale (MRS) was the most commonly used for assessing treatment response, The advantage of the MRS is that there is a relatively extensive database of studies based on it and this will no doubt ensure that it remains a gold standard for the foreseeable future. Other useful rating scales are available for measuring mania but further cross-validation and validation against clinically meaningful global changes are required. A total of 658 patients from 12 trials were included in an evaluation of the efficacy of lithium in the treatment of acute mania. Treatment periods ranged from 3 to 4 weeks. Efficacy was estimated using (i) the differences in the reduction in mania severity scores, and (ii) the ratio and difference in improvement response rates. The response rate ratio for lithium against placebo was 1.95 (95% CI 1.17 to 3.23). The mean number needed to treat was 5 (95% CI 3 to 20). Patients were twice as likely to obtain remission with lithium than with chlorpromazine (rate ratio = 1.96, 95% CI 1.02 to 3.77). The mean number needed to treat (NNT) was 4 (95% CI 3 to 9). Neither carbamazepine nor valproate was more effective than lithium. The response rate ratios were 1.01 (95% CI 0.54 to 1.88) for lithium compared to carbarnazepine and 1.22 (95% CI 0.91 to 1.64) for lithium against valproate. Haloperidol was no better than lithium on the basis of improvement based on assessment of global severity. The differences in effects between lithium and risperidone were -2.79 (95% CI -4.22 to -1.36) in favour of risperidone with respect to symptom severity improvement and -0.76 (95% CI -1.11 to -0,41) on the basis of reduction in global severity of disease. Symptom and global severity was at least as well controlIed with lithium as with verapamil. Lithium caused more side-effects than placebo and verapamil, but no more than carbamazepine or valproate. A total of 554 patients from 13 trials were included in the statistical analysis of lithium's efficacy in the prophylaxis of bipolar disorder. The mean follow-up period was 5-34 months. The relapse risk ratio for lithium versus placebo was 0.47 (95% CI 0.26 to 0.86) and the NNT was 3 (95% CI 2 to 7). The relapse risk ratio for lithium versus imipramine was 0.62 (95% CI 0.46 to 0.84) and the NNT was 4 (951% Cl 3 to 7), The combination of lithium and imipramine was no more effective than lithium alone. The risk of relapse was greater with lithium alone than with the lithium-divalproate combination. A risk difference of 0.60 (95% CI 0.21 to 0.99) and an NNT of 2 (95% CI 1 to 5) were obtained. Lithium was as effective as carbamazepine. Based on individual data concerning plasma haloperidol concentration and percent improvement in psychotic symptoms, our results suggest an acceptable concentration range of 11.20-30.30 ng/mL A minimum of 2 weeks should be allowed before evaluating therapeutic response. Monitoring of drug plasma levels seems not to be necessary unless behavioural toxicity or noncompliance is suspected. Pharmacokinetics and pharmacodynamics, which are mainly determined by genetic factors, contribute to interindividual and interethnic variations in clinical response to drugs. These variations are primarily due to differences in drug metabolism. Variability in pharmacokinetics of a number of drugs is associated with oxidation polymorphism. Debrisoquine/sparteine hydroxylase (CYP2D6) and the S-mephenytoin hydroxylase (CYP2C19) are polymorphic P450 enzymes with particular importance in psychopharmacotherapy. The enzymes are responsible for the metabolism of many commonly used antipsychotic and antidepressant drugs. The incidence of poor metabolisers of debrisoquine and S-mephenytoin varies widely among populations. Ethnic variations in polymorphic isoenzymes may, at least in part, explain ethnic differences in response to pharmacotherapy of antipsychotics and antidepressant drugs.
Resumo:
The need to measure the response of the oculomotor system, such as ocular accommodation, accurately and in real-world environments is essential. New instruments have been developed over the past 50 years to measure eye focus including the extensively utilised and well validated Canon R-1, but in general these have had limitations such as a closed field-of-view, a poor temporal resolution and the need for extensive instrumentation bulk preventing naturalistic performance of environmental tasks. The use of photoretinoscopy and more specifically the PowerRefractor was examined in this regard due to its remote nature, binocular measurement of accommodation, eye movement and pupil size and its open field-of-view. The accuracy of the PowerRefractor to measure refractive error was on averaging similar, but more variable than subjective refraction and previously validated instrumentation. The PowerRefractor was found to be tolerant to eye movements away from the visual axis, but could not function with small pupil sizes in brighter illumination. The PowerRefractor underestimated the lead of accommodation and overestimated the slope of the accommodation stimulus response curve. The PowerRefractor and the SRW-5000 were used to measure the oculomotor responses in a variety of real-world environment: spectacles compared to single vision contract lenses; the use of multifocal contact lenses by pre-presbyopes (relevant to studies on myopia retardation); and ‘accommodating’ intraocular lenses. Due to the accuracy concerns with the PowerRefractor, a purpose-built photoretinoscope was designed to measure the oculomotor response to a monocular head-mounted display. In conclusion, this thesis has shown the ability of photoretinoscopy to quantify changes in the oculomotor system. However there are some major limitations to the PowerRefractor, such as the need for individual calibration for accurate measures of accommodation and vergence, and the relatively large pupil size necessary for measurement.
Resumo:
BACKGROUND: The use of quality of life (QoL) instruments in menorrhagia research is increasing but there is concern that not enough emphasis is placed on patient-focus in these measurements, i.e. on issues which are of importance to patients and reflect their experiences and concerns (clinical face validity). The objective was to assess the quality of QoL instruments in studies of menorrhagia. STUDY DESIGN: A systematic review of published research. Papers were identified through MEDLINE (1966-April 2000), EMBASE (1980-April 2000), Science Citation Index (1981-April 2000), Social Science Citation Index (1981-April 2000), CINAHL (1982-1999) and PsychLIT (1966-1999), and by manual searching of bibliographies of known primary and review articles. Studies were selected if they assessed women with menorrhagia for life quality, either developing QoL instruments or applying them as an outcome measure. Selected studies were assessed for quality of their QoL instruments, using a 17 items checklist including 10 items for clinical face validity (issues of relevance to patients' expectations and concerns) and 7 items for measurement properties (such as reliability, responsiveness, etc.). RESULTS: A total of 19 articles, 8 on instrument development and 11 on application, were included in the review. The generic Short Form 36 Health Survey Questionnaire (SF36) was used in 12/19 (63%) studies. Only two studies developed new specific QoL instruments for menorrhagia but they complied with 7/17 (41%) and 10/17 (59%) of the quality criteria. Quality assessment showed that only 7/19 (37%) studies complied with more than half the criteria for face validity whereas 17/19 (90%) studies complied with more than half of the criteria for measurement properties (P = 0.0001). CONCLUSION: Among existing QoL instruments, there is good compliance with the quality criteria for measurement properties but not with those for clinical face validity. There is a need to develop methodologically sound disease specific QoL instruments in menorrhagia focussing both on face validity and measurement properties.