11 resultados para Antepartum non-stress test

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Distortion is one type of defect in the weld, which is troublesome for some reasons, especially in thin plate welding. Distortion was found in fibre laser welding processing for 0.7mm thickness Ti6Al4V plate. The purpose of this paper is to understand and evaluate the effect of distortion on stress level by FEA and tensile test. A group of 0.7mm Ti6Al4V plates welded using continuous wave fibre laser. FEA models were established for fibre laser welded Ti6Al4V in abaqus 6.7. © (2011) Trans Tech Publications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

John Bowlby's use of evolutionary theory as a cornerstone of his attachment theory was innovative in its day and remains useful. Del Giudice's target article extends Belsky et al.'s and Chisholm's efforts to integrate attachment theory with more current thinking about evolution, ecology, and neuroscience. His analysis would be strengthened by (1) using computer simulation to clarify and simulate the effects of early environmental stress, (2) incorporating information about non-stress related sources of individual differences, (3) considering the possibility of adaptive behavior without specific evolutionary adaptations, and (4) considering whether the attachment construct is critical to his analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Kolmogorov-Smirnov (KS) test is a non-parametric test which can be used in two different circumstances. First, it can be used as an alternative to chi-square (?2) as a ‘goodness-of-fit’ test to compare whether a given ‘observed’ sample of observations conforms to an ‘expected’ distribution of results (KS, one-sample test). An example of the use of the one-sample test to determine whether a sample of observations was normally distributed was described previously. Second, it can be used as an alternative to the Mann-Whitney test to compare two independent samples of observations (KS, two-sample test). Hence, this statnote describes the use of the KS test with reference to two scenarios: (1) to compare the observed frequency (Fo) of soil samples containing cysts of the protozoan Naegleria collected each month for a year with an expected equal frequency (Fe) across months (one-sample test), and (2) to compare the abundance of bacteria on cloths and sponges sampled in a domestic kitchen environment (two-sample test).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many patients are not reassured after receiving normal results following cardiac investigations. While previous studies have shown anxiety to be a contributing factor, little research has investigated the influence of patients’ illness perceptions on reassurance. In this study we investigated whether illness perceptions predicted patients’ reassurance following normal exercise stress test results. Sixty-two chest pain patients without prior diagnosed cardiac pathology completed questionnaires assessing anxiety and illness perceptions prior to exercise stress testing. Patients completed a reassurance questionnaire immediately following their appointment and again one month later. Illness perceptions (consequences, timeline, identity, illness concern, and emotional effect) but not anxiety, significantly predicted reassurance immediately following testing. We found both state anxiety and illness perceptions to predict reassurance one month later. After controlling for anxiety, longer timeline and lower treatment control beliefs predicted lower reassurance. The results suggest that an intervention targeting patients who have high anxiety and negative illness perceptions prior to testing may improve reassurance and decrease disability and the subsequent use of medical care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sign test is a simple non-parametric test which can be used on paired data, i.e., two related samples, matched samples, or repeated measurements on the same sample. It was developed by Wilcoxon before the more powerful and familiar ‘Wilcoxon signed-rank test’ described in a previous statnote . This statnote describes the use of the sign test with reference to two scenarios: (1) to compare the cleanliness of two hospital wards as assessed by a sample of observers and (2) to compare bacterial contamination on cloths and sponges from a domestic kitchen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Edge blur is an important perceptual cue, but how does the visual system encode the degree of blur at edges? Blur could be measured by the width of the luminance gradient profile, peak ^ trough separation in the 2nd derivative profile, or the ratio of 1st-to-3rd derivative magnitudes. In template models, the system would store a set of templates of different sizes and find which one best fits the `signature' of the edge. The signature could be the luminance profile itself, or one of its spatial derivatives. I tested these possibilities in blur-matching experiments. In a 2AFC staircase procedure, observers adjusted the blur of Gaussian edges (30% contrast) to match the perceived blur of various non-Gaussian test edges. In experiment 1, test stimuli were mixtures of 2 Gaussian edges (eg 10 and 30 min of arc blur) at the same location, while in experiment 2, test stimuli were formed from a blurred edge sharpened to different extents by a compressive transformation. Predictions of the various models were tested against the blur-matching data, but only one model was strongly supported. This was the template model, in which the input signature is the 2nd derivative of the luminance profile, and the templates are applied to this signature at the zero-crossings. The templates are Gaussian derivative receptive fields that covary in width and length to form a self-similar set (ie same shape, different sizes). This naturally predicts that shorter edges should look sharper. As edge length gets shorter, responses of longer templates drop more than shorter ones, and so the response distribution shifts towards shorter (smaller) templates, signalling a sharper edge. The data confirmed this, including the scale-invariance implied by self-similarity, and a good fit was obtained from templates with a length-to-width ratio of about 1. The simultaneous analysis of edge blur and edge location may offer a new solution to the multiscale problem in edge detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When testing the difference between two groups, if previous data indicate non-normality, then either transform the data if they comprise percentages, integers or scores or use a non-parametric test. If there is uncertainty whether the data are normally distributed, then deviations from normality are likely to be small if the data are measurements to three significant figures. Unless there is clear evidence that the distribution is non-normal, it is more efficient to use the conventional t-tests. It is poor statistical practice to carry out both the parametric and non-parametric tests on a set of data and then choose the result that is most convenient to the investigator!

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There may be circumstances where it is necessary for microbiologists to compare variances rather than means, e,g., in analysing data from experiments to determine whether a particular treatment alters the degree of variability or testing the assumption of homogeneity of variance prior to other statistical tests. All of the tests described in this Statnote have their limitations. Bartlett’s test may be too sensitive but Levene’s and the Brown-Forsythe tests also have problems. We would recommend the use of the variance-ratio test to compare two variances and the careful application of Bartlett’s test if there are more than two groups. Considering that these tests are not particularly robust, it should be remembered that the homogeneity of variance assumption is usually the least important of those considered when carrying out an ANOVA. If there is concern about this assumption and especially if the other assumptions of the analysis are also not likely to be met, e.g., lack of normality or non additivity of treatment effects then it may be better either to transform the data or to carry out a non-parametric test on the data.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The object of this work was to further develop the idea introduced by Muaddi et al (1981) which enables some of the disadvantages of earlier destructive adhesion test methods to be overcome. The test is non-destructive in nature but it does need to be calibrated against a destructive method. Adhesion is determined by measuring the effect of plating on internal friction. This is achieved by determining the damping of vibrations of a resonating specimen before and after plating. The level of adhesion was considered by the above authors to influence the degree of damping. In the major portion of the research work the electrodeposited metal was Watt's nickel, which is ductile in nature and is therefore suitable for peel adhesion testing. The base metals chosen were aluminium alloys S1C and HE9 as it is relatively easy to produce varying levels of adhesion between the substrate and electrodeposited coating by choosing the appropriate process sequence. S1C alloy is the commercially pure aluminium and was used to produce good adhesion. HE9 aluminium alloy is a more difficult to plate alloy and was chosen to produce poorer adhesion. The "Modal Testing" method used for studying vibrations was investigated as a possible means of evaluating adhesion but was not successful and so research was concentrated on the "Q" meter. The method based on the use of a "Q" meter involves the principle of exciting vibrations in a sample, interrupting the driving signal and counting the number of oscillations of the freely decaying vibrations between two known preselected amplitudes of oscillations. It was not possible to reconstruct a working instrument using Muaddi's thesis (1982) as it had either a serious error or the information was incomplete. Hence a modified "Q" meter had to be designed and constructed but it was then difficult to resonate non-magnetic materials, such as aluminium, therefore, a comparison before and after plating could not be made. A new "Q" meter was then developed based on an Impulse Technique. A regulated miniature hammer was used to excite the test piece at the fundamental mode instead of an electronic hammer and test pieces were supported at the two predetermined nodal points using nylon threads. This instrument developed was not very successful at detecting changes due to good and poor pretreatments given before plating, however, it was more sensitive to changes at the surface such as room temperature oxidation. Statistical analysis of test results from untreated aluminium alloys show that the instrument is not always consistent, the variation was even bigger when readings were taken on different days. Although aluminium is said to form protective oxides at room temperature there was evidence that the aluminium surface changes continuously due to film formation, growth and breakdown. Nickel plated and zinc alloy immersion coated samples also showed variation in Q with time. In order to prove that the variations in Q were mainly due to surface oxidation, aluminium samples were lacquered and anodised Such treatments enveloped the active surfaces reacting with the environment and the Q variation with time was almost eliminated especially after hard anodising. This instrument detected major differences between different untreated aluminium substrates.Also Q values decreased progressively as coating thicknesses were increased. This instrument was also able to detect changes in Q due to heat-treatment of aluminium alloys.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The early stages of dieting to lose weight have been associated with neuro-psychological impairments. Previous work has not elucidated whether these impairments are a function solely of unsupported or supported dieting. Raised cortico-steroid levels have been implicated as a possible causal mechanism. Healthy, overweight, pre-menopausal women were randomised to one of three conditions in which they dieted either as part of a commercially available weight loss group, dieted without any group support or acted as non-dieting controls for 8 weeks. Testing occurred at baseline and at 1, 4 and 8 weeks post baseline. During each session, participants completed measures of simple reaction time, motor speed, vigilance, immediate verbal recall, visuo-spatial processing and (at Week 1 only) executive function. Cortisol levels were gathered at the beginning and 30 min into each test session, via saliva samples. Also, food intake was self-recorded prior to each session and fasting body weight and percentage body fat were measured at each session. Participants in the unsupported diet condition displayed poorer vigilance performance (p=0.001) and impaired executive planning function (p=0.013) (along with a marginally significant trend for poorer visual recall (p=0.089)) after 1 week of dieting. No such impairments were observed in the other two groups. In addition, the unsupported dieters experienced a significant rise in salivary cortisol levels after 1 week of dieting (p<0.001). Both dieting groups lost roughly the same amount of body mass (p=0.011) over the course of the 8 weeks of dieting, although only the unsupported dieters experienced a significant drop in percentage body fat over the course of dieting (p=0.016). The precise causal nature of the relationship between stress, cortisol, unsupported dieting and cognitive function is, however, uncertain and should be the focus of further research. © 2005 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents MRI measurements of a novel semi solid MR contrast agent to pressure. The agent is comprised of potassium chloride cross linked carageenan gum at a concentration of 2% w/v, with micron size lipid coated bubbles of air at a concentration of 3% v/v. The choice for an optimum suspending medium, the methods of production and the preliminary MRI results are presented herein. The carageenan gum is shown to be ideally elastic for compressions relating to volume changes less than 15%, in contrast to the inelastic gellan gum also tested. Although slightly lower than that of gellan gum, carageenan has a water diffusion coefficient of 1.72×10-9 m2.s-1 indicating its suitability to this purpose. RARE imaging is performed whilst simultaneously compressing test and control samples and a maximum sensitivity of 1.6% MR signal change per % volume change is found which is shown to be independent of proton density variations due to the presence of microbubbles and compression. This contrast agent could prove useful for numerous applications, and particularly in chemical engineering. More generally the method allows the user to non-invasively image with MRI any process that causes, within the solid, local changes either in bubble size or bubble shape. © 2008 American Institute of Physics.