7 resultados para Antenatal
em Aston University Research Archive
Resumo:
Circulating antiangiogenic factors and proinflammatory cytokines are implicated in the pathogenesis of preeclampsia. This study was performed to test the hypothesis that steroids modify the balance of inflammatory and proangiogenic and antiangiogenic factors that potentially contribute to the patient’s evolving clinical state. Seventy singleton women, admitted for antenatal corticosteroid treatment, were enrolled prospectively. The study group consisted of 45 hypertensive women: chronic hypertension (n=6), severe preeclampsia (n=32), and superimposed preeclampsia (n=7). Normotensive women with shortened cervix (<2.5 cm) served as controls (n=25). Maternal blood samples of preeclampsia cases were obtained before steroids and then serially up until delivery. A clinical severity score was designed to clinically monitor disease progression. Serum levels of angiogenic factors (soluble fms-like tyrosine kinase-1 [sFlt-1], placental growth factor [PlGF], soluble endoglin [sEng]), endothelin-1 (ET-1), and proinflammatory markers (IL-6, C-reactive protein [CRP]) were assessed before and after steroids. Soluble IL-2 receptor (sIL-2R) and total immunoglobulins (IgG) were measured as markers of T- and B-cell activation, respectively. Steroid treatment coincided with a transient improvement in clinical manifestations of preeclampsia. A significant decrease in IL-6 and CRP was observed although levels of sIL-2R and IgG remained unchanged. Antenatal corticosteroids did not influence the levels of angiogenic factors but ET-1 levels registered a short-lived increase poststeroids. Although a reduction in specific inflammatory mediators in response to antenatal steroids may account for the transient improvement in clinical signs of preeclampsia, inflammation is unlikely to be the major contributor to severe preeclampsia or useful for therapeutic targeting.
Resumo:
Circulating antiangiogenic factors and proinflammatory cytokines are implicated in the pathogenesis of preeclampsia. This study was performed to test the hypothesis that steroids modify the balance of inflammatory and proangiogenic and antiangiogenic factors that potentially contribute to the patient's evolving clinical state. Seventy singleton women, admitted for antenatal corticosteroid treatment, were enrolled prospectively. The study group consisted of 45 hypertensive women: chronic hypertension (n=6), severe preeclampsia (n=32), and superimposed preeclampsia (n=7). Normotensive women with shortened cervix (<2.5 cm) served as controls (n=25). Maternal blood samples of preeclampsia cases were obtained before steroids and then serially up until delivery. A clinical severity score was designed to clinically monitor disease progression. Serum levels of angiogenic factors (soluble fms-like tyrosine kinase-1 [sFlt-1], placental growth factor [PlGF], soluble endoglin [sEng]), endothelin-1 (ET-1), and proinflammatory markers (IL-6, C-reactive protein [CRP]) were assessed before and after steroids. Soluble IL-2 receptor (sIL-2R) and total immunoglobulins (IgG) were measured as markers of T- and B-cell activation, respectively. Steroid treatment coincided with a transient improvement in clinical manifestations of preeclampsia. A significant decrease in IL-6 and CRP was observed although levels of sIL-2R and IgG remained unchanged. Antenatal corticosteroids did not influence the levels of angiogenic factors but ET-1 levels registered a short-lived increase poststeroids. Although a reduction in specific inflammatory mediators in response to antenatal steroids may account for the transient improvement in clinical signs of preeclampsia, inflammation is unlikely to be the major contributor to severe preeclampsia or useful for therapeutic targeting. © 2014 American Heart Association, Inc.
Resumo:
Background The risk of adverse pregnancy outcome for women with type 1 diabetes is reduced through tight diabetes control. Most women enter pregnancy with inadequate blood glucose control. Interview studies with women suggest the concept of ‘planned’ and ‘unplanned’ pregnancies is unhelpful. Aim To explore women's accounts of their journeys to becoming pregnant while living with type 1 diabetes. Design of study Semi-structured interviews with 15 women living with pre-gestational type 1 diabetes, between 20 and 30 weeks gestation and with a normal pregnancy ultrasound scan. Setting Four UK specialist diabetes antenatal clinics. Method Interviews explored women's journeys to becoming pregnant and the impact of health care. Analysis involved comparison of women's accounts of each pregnancy and a thematic analysis. Results Women's experiences of becoming pregnant were diverse. Of the 40 pregnancies described, at least one positive step towards becoming pregnant was taken by 11 women in 23 pregnancies but not in the remaining 17 pregnancies, with variation between pregnancies. Prior to and in early pregnancy, some women described themselves as experts in their diabetes but most described seeking and/or receiving advice from their usual health professionals. Three women described pre-conception counselling and the anxiety this provoked. Conclusion For women living with type 1 diabetes each pregnancy is different. The concept of planned and unplanned pregnancy is unhelpful for designing health care. Formal preconception counselling can have unintended consequences. Those providing usual care to women are well positioned to provide advice and support to women about becoming pregnant, tailoring it to the changing needs and situation of each woman.
Resumo:
Women are actively encouraged to educate themselves about pregnancy from formal sources (e.g., information leaflets, antenatal classes, books). In addition, informal stories of pregnancy and birth are routinely told between women. However, increased prenatal testing means that more fetuses are diagnosed with abnormalities, shifting the information requirements during pregnancy. Traditional sources of information cannot cover all possible outcomes, and the Internet is beginning to fill this gap. In this article, we draw from interviews about experiences of antenatal screening and pregnancy to explore how the Internet provides a unique resource for problematic pregnancies. It allows access to information about rarer conditions beyond standard pregnancy texts, as well as personal narratives about conditions. Learning how others have coped or are coping in similar situations can help alleviate feelings of isolation, and also places women back in a familiar territory of shared pregnancy narratives.
Resumo:
Poster section Design. Retrospective study. Purpose. To assess whether there are changes in foveal thickness (FT) and total macular volume (TMV) in pregnancy in diabetic subjects. Methods. The audit consisted of pregnant women with diabetes, with no maculopathy, who completed their antenatal care at Birmingham Heartlands Hospital. The Zeiss Stratus Optical coherence tomography (OCT) was performed on patients attending diabetic retinopathy (DR) screening at intervals throughout their pregnancy. To be included in the audit patients had to have at least one OCT scan during their pregnancy. Results. Altogether there were 8 type 1 and 22 type 2 patients with mean diabetes duration of 6 years (range 1-20). Mean gestation at DR screening with OCT during the first trimester was 9.7 weeks (6-13) (n=22). The mean and standard deviation for FT for the right was 179.1 µm ± 21.49 and for the left eye was 187.3 µm ± 23.55. The mean TMV was right 6.43 µm ± 0.35 and left 6.50 µm ± 0.39. The mean gestation at DR screening with OCT during the second trimester was 23.4 weeks (18-26) (n=25). The mean FT for the right was 191.4 µm ± 22.70 and the left 195.6 µm ± 24.77. The mean TMV was right 6.74 µm ± 0.45 and left 6.91 µm ± 0.35. The gestation of DR screening with OCT during the third trimester was 31.1 weeks (27-36) (n=15). The mean FT for the right was 181.5 µm ± 24.84 and for the left 193.1 µm ± 28.55. The mean TMV was right 6.80 µm ± 0.40 and left 6.84 µm ± 0.31. There were no significant differences in FT over the 3 trimesters. The TMV showed a significant difference when comparing the first and second trimesters (p<0.05). However, there was no significant statistical difference in TMV in the second and third trimesters. None of the patients showed any macula edema on the OCT. Conclusions. The results suggest there is no significant change in foveal thickness in pregnancy in diabetic subjects. There was a significant statistical difference in total macular volume in the second trimester; however, this would not be clinically significant. This is an important observation proven by the OCT which has not been previously studied.
Resumo:
Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. Setting: Six UK maternity units. Participants: These were 20,055 asymptomatic newborns at = 35 weeks’ gestation, their mothers and health-care staff. Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). Main outcome measures: Detection of major CHDs – defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.
Resumo:
Aims: The Tuberous Sclerosis 2000 Study is the first comprehensive longitudinal study of tuberous sclerosis (TS) and aims to identify factors that determine prognosis. Mode of presentation and findings at initial assessments are reported here. Methods: Children aged 0-16 years newly diagnosed with TS in the UK were evaluated. Results: 125 children with TS were studied. 114 (91%) met clinical criteria for a definite diagnosis and the remaining 11 (9%) had pathogenic TSC1 or TSC2 mutations. In families with a definite clinical diagnosis, the detection rate for pathogenic mutations was 89%. 21 cases (17%) were identified prenatally, usually with abnormalities found at routine antenatal ultrasound examination. 30 cases (24%) presented before developing seizures and in 10 of these without a definite diagnosis at onset of seizures, genetic testing could have confirmed TS. 77 cases (62%) presented with seizures. Median age at recruitment assessment was 2.7 years (range:4 weeks-18 years). Dermatological features of TS were present in 81%. The detection rate of TS abnormalities was 20/107 (19%) for renal ultrasound including three cases with polycystic kidney disease, 51/88 (58%) for echocardiography, 29/35 (83%) for cranial CT and 95/104 (91%) for cranial MRI. 91% of cases had epilepsy and 65% had intellectual disability (IQ<70). Conclusions: Genetic testing can be valuable in confirming the diagnosis. Increasing numbers of cases present prenatally or in early infancy, before onset of seizures, raising important questions about whether these children should have EEG monitoring and concerning the criteria for starting anticonvulsant therapy.