6 resultados para Angle measurement
em Aston University Research Archive
Resumo:
This paper shows how the angular uncertainties can be determined for a rotary-laser automatic theodolite of the type used in (indoor-GPS) iGPS networks. Initially, the fundamental physics of the rotating head device is used to propagate uncertainties using Monte Carlo simulation. This theoretical element of the study shows how the angular uncertainty is affected by internal parameters, the actual values of which are estimated. Experiments are then carried out to determine the actual uncertainty in the azimuth angle. Results are presented that show that uncertainty decreases with sampling duration. Other significant findings are that uncertainty is relatively constant throughout the working volume and that the uncertainty value is not dependent on the size of the reference angle. © 2009 IMechE.
Autonomic dysfunction in unselected and untreated primary open angle glaucoma patients:A pilot study
Resumo:
Purpose: To investigate the presence of silent cardiac ischaemic episodes and the status of autonomic function in consecutive, newly diagnosed and untreated primary open-angle glaucoma patients. Methods: Twenty-four consecutively diagnosed glaucoma patients and 22 age-matched controls were subjected to ambulatory 24-h blood pressure (BP) and electrocardiogram (ECG) monitoring by using Cardiotens-01 (Meditech Ltd). Based on the ECG recordings, heart rate variability (HRV) frequency domain parameters [low-frequency (LF), high-frequency (HF) and LF/HF ratio] were calculated and analysed in the two study groups. Results: Glaucoma patients demonstrated higher LF and LF/HF values than normal subjects for both the active period (p = 0.020 and 0.029) and the passive period (p = 0.044 and 0.049 respectively). HRV parameters were similar in patients and controls suffering from silent cardiac ischaemia (p > 0.05); however, glaucoma patients with normal ECG demonstrated higher LF and LF/HF values during the active period of the 24-h measurement period than control subjects characterized by the same cardiac activity (p = 0.010 and 0.021 respectively). Conclusion: Independent of a history and/or clinical signs of cardiovascular disease, glaucoma patients exhibit abnormal autonomic function. © 2007 The Authors.
Resumo:
Purpose: To analyse the relationship between measured intraocular pressure (IOP) and central corneal thickness (CCT), corneal hysteresis (CH) and corneal resistance factor (CRF) in ocular hypertension (OHT), primary open-angle (POAG) and normal tension glaucoma (NTG) eyes using multiple tonometry devices. Methods: Right eyes of patients diagnosed with OHT (n=47), normal tension glaucoma (n=17) and POAG (n=50) were assessed, IOP was measured in random order with four devices: Goldmann applanation tonometry (GAT); Pascal(R) dynamic contour tonometer (DCT); Reichert(R) ocular response analyser (ORA); and Tono-Pen(R) XL. CCT was then measured using a hand-held ultrasonic pachymeter. CH and CRF were derived from the air pressure to corneal reflectance relationship of the ORA data. Results: Compared to the GAT, the Tonopen and ORA Goldmann equivalent (IOPg) and corneal compensated (IOPcc) measured higher IOP readings (F=19.351, p<0.001), particularly in NTG (F=12.604, p<0.001). DCT was closest to Goldmann IOP and had the lowest variance. CCT was significantly different (F=8.305, p<0.001) between the 3 conditions as was CH (F=6.854, p=0.002) and CRF (F=19.653, p<0.001). IOPcc measures were not affected by CCT. The DCT was generally not affected by corneal biomechanical factors. Conclusion: This study suggests that as the true pressure of the eye cannot be determined non-invasively, measurements from any tonometer should be interpreted with care, particularly when alterations in the corneal tissue are suspected.
Resumo:
We demonstrate the sensitivity of Bragg gratings in a multicore fiber to transverse load. The Bragg peaks are split because of stress-induced birefringence, the magnitude of which depends upon the load and grating position relative to the load axis. Experiments show that a set of gratings in a four-core fiber can measure a load axis angle to ±5° and a load magnitude to ±15 N m-1 up to 2500 N m-1. We consider alternative designs of multicore fiber for optimal load sensing and compare experimental and modeled data. © 2005 Optical Society of America.
Resumo:
Accurate measurement of intervertebral kinematics of the cervical spine can support the diagnosis of widespread diseases related to neck pain, such as chronic whiplash dysfunction, arthritis, and segmental degeneration. The natural inaccessibility of the spine, its complex anatomy, and the small range of motion only permit concise measurement in vivo. Low dose X-ray fluoroscopy allows time-continuous screening of cervical spine during patient's spontaneous motion. To obtain accurate motion measurements, each vertebra was tracked by means of image processing along a sequence of radiographic images. To obtain a time-continuous representation of motion and to reduce noise in the experimental data, smoothing spline interpolation was used. Estimation of intervertebral motion for cervical segments was obtained by processing patient's fluoroscopic sequence; intervertebral angle and displacement and the instantaneous centre of rotation were computed. The RMS value of fitting errors resulted in about 0.2 degree for rotation and 0.2 mm for displacements. © 2013 Paolo Bifulco et al.