22 resultados para Ambulatory

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ambulatory EEG recording enables patients with epilepsy and related disorders to be monitored in an unrestricted environment for prolonged periods. Attacks can therefore be recorded and EEG changes at the time can aid diagnosis. The relevant Iiterature is reviewed and a study made of' 250 clinical investigations. A study was also made of the artefacts,encountered during ambulatory recording. Three quarters of referrals were for distinguishing between epileptic and non-epileptic attacks. Over 60% of patients showed no abnormality during attacks. In comparison with the basic EEG the ambulatory EEG provided about ten times as much information. A preliminary follow-up study showed that results, of ambulatory monitoring agreed with the final diagnosis in 8 of 12 patients studied. Of 10 patients referred, for monitoring the occurrence of absence seizures, 8 showed abnormality during the baslcJ EEG .and 10 during the ambulatory EEG. Other patients. were referred: for sleep recording and to clarify the seizure type. An investigation into once daily (OD) versus twice daily administration of sodium valproate in patients with absence seizures showed that an OD regime was equally as effective as a BD regime. Circadian variations in spike and wave activity in patients on and off treatment were also examined. There was significant agreement between subjects on the time of occurrence of abnormality during sleep only, This pattern was not ,affected with treatment nor was there any difference in the daily pattern of occurrence of abnormality between the two regimes. Overall findings suggested that ambulatory monitoring was a valuable tool in the diagnosis and treatment of epilepsy which with careful planning and patient selection could be used in any EEG department and would benefit a:wide range of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an innovative sensing approach allowing capture, discrimination, and classification of transients automatically in gait. A walking platform is described, which offers an alternative design to that of standard force plates with advantages that include mechanical simplicity and less restriction on dimensions. The scope of the work is to investigate as an experiment the sensitivity of the distributive tactile sensing method with the potential to address flexibility on gait assessment, including patient targeting and the extension to a variety of ambulatory applications. Using infrared sensors to measure plate deflection, gait patterns are compared with stored templates using a pattern recognition algorithm. This information is input into a neural network to classify normal and affected walking events, with a classification accuracy of just under 90 per cent achieved. The system developed has potential applications in gait analysis and rehabilitation, whereby it can be used as a tool for early diagnosis of walking disorders or to determine changes between pre- and post-operative gait.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ambulatory electroencephalogram has been used for differentiating epileptic from nonepileptic events, recording seizure frequency and classification of seizure type. We studied 100 consecutive children prospectively aged 11 days to 16 years that were referred for an ambulatory electroencephalogram to a regional children's hospital. Ambulatory electroencephalogram was clinically useful in contributing to a clinical diagnosis in 71% of children who were referred with a range of clinical questions. A diagnosis of epileptic disorder was confirmed by obtaining an ictal record in 26% and this included 11 children that had previously normal awake and or sleep electroencephalogram. We recommend making a telephone check of the current target event frequency and prioritising those with typical events on most days in order to improve the frequency of recording a typical attack.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate the relationship between the occurrence of transient cardiac ischaemic episodes and variations in the ambulatory 24-h blood pressure and heart rate measurements in a group of unselected glaucoma patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background & Aims: Esophageal hypersensitivity is thought to be important in the generation and maintenance of symptoms in noncardiac chest pain (NCCP). In this study, we explored the neurophysiologic basis of esophageal hypersensitivity in a cohort of NCCP patients. Methods: We studied 12 healthy controls (9 women; mean age, 37.1 ± 8.7 y) and 32 NCCP patients (23 women; mean age, 47.2 ± 10 y). All had esophageal manometry, esophageal evoked potentials to electrical stimulation, and NCCP patients had 24-hour ambulatory pH testing. Results: The NCCP patients had reduced pain thresholds (PT) (72.1 ± 19.4 vs 54.2 ± 23.6, P = .02) and increased P1 latencies (P1 = 105.5 ± 11.1 vs 118.1 ± 23.4, P = .02). Subanalysis showed that the NCCP group could be divided into 3 distinct phenotypic classifications. Group 1 had reduced pain thresholds in conjunction with normal/reduced latency P1 latencies (n = 9). Group 2 had reduced pain thresholds in conjunction with increased (>2.5 SD) P1 latencies (n = 7), and group 3 had normal pain thresholds in conjunction with either normal (n = 10) or increased (>2.5 SD, n = 3) P1 latencies. Conclusions: Normal esophageal evoked potential latencies with reduced PT, as seen in group 1 patients, is indicative of enhanced afferent transmission and therefore increased esophageal afferent pathway sensitivity. Increased esophageal evoked potential latencies with reduced PT in group 2 patients implies normal afferent transmission to the cortex but heightened secondary cortical processing of this information, most likely owing to psychologic factors such as hypervigilance. This study shows that NCCP patients with esophageal hypersensitivity may be subclassified into distinct phenotypic subclasses based on sensory responsiveness and objective neurophysiologic profiles. © 2006 by the American Gastroenterological Association.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the presence of silent cardiac ischaemic episodes and the status of autonomic function in consecutive, newly diagnosed and untreated primary open-angle glaucoma patients. Methods: Twenty-four consecutively diagnosed glaucoma patients and 22 age-matched controls were subjected to ambulatory 24-h blood pressure (BP) and electrocardiogram (ECG) monitoring by using Cardiotens-01 (Meditech Ltd). Based on the ECG recordings, heart rate variability (HRV) frequency domain parameters [low-frequency (LF), high-frequency (HF) and LF/HF ratio] were calculated and analysed in the two study groups. Results: Glaucoma patients demonstrated higher LF and LF/HF values than normal subjects for both the active period (p = 0.020 and 0.029) and the passive period (p = 0.044 and 0.049 respectively). HRV parameters were similar in patients and controls suffering from silent cardiac ischaemia (p > 0.05); however, glaucoma patients with normal ECG demonstrated higher LF and LF/HF values during the active period of the 24-h measurement period than control subjects characterized by the same cardiac activity (p = 0.010 and 0.021 respectively). Conclusion: Independent of a history and/or clinical signs of cardiovascular disease, glaucoma patients exhibit abnormal autonomic function. © 2007 The Authors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Respiration is a complex activity. If the relationship between all neurological and skeletomuscular interactions was perfectly understood, an accurate dynamic model of the respiratory system could be developed and the interaction between different inputs and outputs could be investigated in a straightforward fashion. Unfortunately, this is not the case and does not appear to be viable at this time. In addition, the provision of appropriate sensor signals for such a model would be a considerable invasive task. Useful quantitative information with respect to respiratory performance can be gained from non-invasive monitoring of chest and abdomen motion. Currently available devices are not well suited in application for spirometric measurement for ambulatory monitoring. A sensor matrix measurement technique is investigated to identify suitable sensing elements with which to base an upper body surface measurement device that monitors respiration. This thesis is divided into two main areas of investigation; model based and geometrical based surface plethysmography. In the first instance, chapter 2 deals with an array of tactile sensors that are used as progression of existing and previously investigated volumetric measurement schemes based on models of respiration. Chapter 3 details a non-model based geometrical approach to surface (and hence volumetric) profile measurement. Later sections of the thesis concentrate upon the development of a functioning prototype sensor array. To broaden the application area the study has been conducted as it would be fore a generically configured sensor array. In experimental form the system performance on group estimation compares favourably with existing system on volumetric performance. In addition provides continuous transient measurement of respiratory motion within an acceptable accuracy using approximately 20 sensing elements. Because of the potential size and complexity of the system it is possible to deploy it as a fully mobile ambulatory monitoring device, which may be used outside of the laboratory. It provides a means by which to isolate coupled physiological functions and thus allows individual contributions to be analysed separately. Thus facilitating greater understanding of respiratory physiology and diagnostic capabilities. The outcome of the study is the basis for a three-dimensional surface contour sensing system that is suitable for respiratory function monitoring and has the prospect with future development to be incorporated into a garment based clinical tool.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sixty coagulase-negative staphylococcus (CNS) isolates were recovered from the blood cultures or peritoneal dialysate effluent of 43 patients on renal dialysis. The patients had either renal dialysis catheter-related sepsis (CRS) or continuous ambulatory peritoneal dialysis (CAPD)-associated peritonitis. Isolates were characterized by biotyping, and genotyped by pulsed-field gel electrophoresis (PFGE). Phenotypic properties of the strains were also investigated. Several genotypes were identified with no one specific strain of CNS being associated with CRS. However, closely related strains were isolated from several patients within the units studied, suggesting horizontal transfer of micro-organisms. Genotypic macro-restriction profiles did not concur with phenotypic profiles or biotypes, confirming that genotyping is required for epidemiological studies. All staphylococcal strains were investigated for the production of phenotypic characteristics. Significant differences were predominantly seen in the production of lipase, esterase and elastase in strains isolated from the renal patients with CRS and CAPD-associated peritonitis, compared with a non-septic control group. These phenotypic characteristics may therefore have a role in the maintenance of CRS in renal patients. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gram-positive microorganisms, specifically coagulase-negative staphylococci are the most common species recovered from clinical culture specimens of patients with end-stage renal disease. The propensity of coagulase-negative staphylococci (CNS) to cause infection in this patient group has been widely debated. However, it is still unclear how this usually avirulent commensal microorganism produces infection that contributes to high rates of morbidity and mortality in patients with end-stage renal disease. The aim of this thesis was to investigate the rate, geographical distribution, molecular and phenotypic mechanisms of Gram-positive microorganisms associated with infection in renal dialysis patients. In addition, it sought to assess the value of early serological diagnosis of dialysis catheter-associated infection and the effect of antimicrobial treatment regimens on the faecal carriage of enteric microorganisms. In this study, the incidence of haemodialysis catheter-associated infection was established with the Meditrend audit tool. This tool was used to assess the infection outcomes of catheter insertion and management procedures until the catheter was explanted. Introduction of a catheter management protocol decreased the incidence of catheter-related infection. Staphylococcal species recovered from episodes of haemodialysis catheter-associated infection and continuous ambulatory peritoneal dialysis (CAPD)-associated peritonitis were genotyped by determination of macrorestriction profiles with pulsed-field gel electrophoresis. This highlighted horizontal transfer of microorganisms between different patients and the environment. The phenotypic characteristics of these strains were also investigated to determine characteristics that could be used as markers for dialysis catheter-associated infection. The expression of elastase, lipase and esterase by CNS was significantly associated with infection. A rapid enzyme-linked immunosorbent assay incorporating a novel staphylococcal antigen (lipid S) was used to evaluate the early detection of anti-staphylococcal immunoglobulin gamma in patient sera. The comparison of culture positive and culture negative patients demonstrated a steady state of immune activation in both groups. However anti-lipid S serum antibody titres > 1000 were found to be a predictor of infection. The effect on faecal carriage of vancomycin resistant enterococci (VRE) and Clostridium difficile toxins in patients treated with CAPD when empiric cephalosporin therapy was substituted for piperacillin/tazobactam was investigated. The introduction of piperacillin/tazobactam demonstrated a decrease in the faecal carriage of VRE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the following studies was to explore the effect of systemic vascular and endothelial dysfunction upon the ocular circulation and functionality of the retina. There are 6 principal sections to the present work. Retinal vessel activity in smokers and non-smokers: the principal findings of this work were: chronic smoking affects retinal vessel motion at baseline and during stimulation with flickering light; chronic smoking leads to a vaso-constrictory shift in retinal arteriolar reactivity to flicker; retinal arteriolar elasticity is decreased in chronic smokers. The effect of acute smoking on retinal vessel dynamics in smokers and non-smokers: the principal finding of this work was that retinal reactivity in chronic smokers is blunted when exposed to clicker light provocation immediately after smoking one cigarette. Ocular blood flow in coronary artery disease: The principal findings of this work were: retrobulbar and retinal blood flow is preserved in CAD patients, despite a change pulse wave transmission; arterial retinal response to flickering light provocation is significantly delayed in CAD patients; retinal venular diameters are significantly dilated in CAD patients. Autonomic nervous system function and peripheral circulation in CAD: The principal findings in this work were: CAD patients demonstrate a sympathetic overdrive during a 24 period; a delay in peripheral vascular reactivity (nail-fold capillaries) as observed in patients suffering from CAD could be caused by either arteriosclerotic changes of the vascular walls or due to systemic haemodynamic changes. Visual function in CAD: The principal findings in this work were: overall visual function in CAD patients is preserved, despite a decrease in contrast sensitivity; applying a filtering technique selecting those with greater coefficient of variance which in turn represents a decrease in reliability, some patients appear to have an impaired visual function as assessed using FDT visual field evaluation. Multiple functional, structural and biochemical vascular endothelial dysfunctions in patients suffering from CAD: relationships and possible implications: The principal findings of this work were: BMI significantly correlated with vWF (a marker of endothelial function) in CAD patients. Retinal vascular reactivity showed a significant correlation with peripheral reactivity parameters in controls which lacked in the CAD group and could reflect a loss in vascular endothelial integrity; visual field parameters as assessed by frequency doubling technology were strongly related with systemic vascular elasticity (ambulatory arterial stiffness index) in controls but not CAD patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare and contrast the presence of ocular and systemic vascular function in newly diagnosed and previously untreated primary open angle glaucoma (POAG) and normal tension glaucoma (NTG) patients with comparable, early stage, functional loss. Methods: The systemic vascular function of 19 POAG patients, 19 NTG patients and 20 healthy controls was assessed by means of 24 hour ambulatory blood pressure (ABPM), peripheral pulse wave analysis (PWA) and carotid intima-media thickness (IMT). Retinal vascular reactivity to flicker light was assessed using dynamic retinal vessel analysis (DVA,IMEDOS, GmbH, Jena, Germany). Results: When compared to normal controls, both POAG and NTG patients exhibited similarly increased nocturnal systemic blood pressure variability (p=0.011); peripheral arterial stiffness (p=0.015), carotid IMT (p=0.040) and reduced ocular perfusion pressure (OPP) (p<0.001). Furthermore, on DVA analysis, both groups of glaucoma patients also exhibited steeper retinal arterial constriction slopes (slope AC) following cessation of flicker (p=0.007) and a similarly increased fluctuation in arterial and venous baseline diameter (p=0.008 and p=0.009 respectively) in comparison to controls. Conclusion: POAG and NTG patients exhibit similar alterations in both ocular and systemic circulation at the early stages of their disease process. This highlights not only the importance of considering vascular risk factors in both conditions, but also raises questions about the current separation of the two conditions into completely distinct clinical entities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

NADPH oxidase (Nox)-derived reactive oxygen species (ROS) are known to be involved in angiotensin II-induced hypertension and endothelial dysfunction. Several Nox isoforms are expressed in the vessel wall, among which Nox2 is especially abundant in the endothelium. Endothelial Nox2 levels rise during hypertension but little is known about the cell-specific role of endothelial Nox2 in vivo. To address this question, we generated transgenic mice with endothelial-specific overexpression of Nox2 (Tg) and studied the effects on endothelial function and blood pressure. Tg had an about twofold increase in endothelial Nox2 levels which was accompanied by an increase in p22phox levels but no change in levels of other Nox isoforms or endothelial nitric oxide synthase (eNOS). Basal NADPH oxidase activity, endothelial function and blood pressure were unaltered in Tg compared to wild-type littermates. Angiotensin II caused a greater increase in ROS production in Tg compared to wild-type aorta and attenuated acetylcholine-induced vasorelaxation. Both low and high dose chronic angiotensin II infusion increased telemetric ambulatory blood pressure more in Tg compared to wild-type, but with different patterns of BP change and aortic remodeling depending upon the dose of angiotensin II dose. These results indicate that an increase in endothelial Nox2 levels contributes to angiotensin II-induced endothelial dysfunction, vascular remodeling and hypertension. © 2011 The Author(s).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An einer Studie zum Zusammenhang zwischen der Gesundheit von Unternehmern, deren Arbeitsmerkmalen und deren Erfolg nahmen 53 klein- und mittelständische Unternehmer teil. Erfasste Arbeitsmerkmale waren: Handlungs-/Entscheidungsspielraum, Arbeitsintensität, Arbeitszeit, Konkurrenzdruck und Prognose über die Auftragsentwicklung. Der Unternehmenserfolg wurde über das Mitarbeiterwachstum, die Möglichkeit des Unternehmers, von seiner Firma abwesend zu sein (Urlaubstage), und dem erlebten Unternehmenserfolg operationalisiert. Gesundheitsindikatoren waren Depression, Angst, vitale Erschöpfung, Schlafstörungen und Bluthochdruck. Im Vergleich zur Gesamtbevölkerung wiesen die Unternehmer in allen untersuchten Gesundheitsvariablen häufiger Beeinträchtigungen auf. Regressionsanalysen ergaben, dass lange Arbeitszeiten und Konkurrenzdruck mit einer verzögerten Rückstellung des systolischen Blutdrucks (SBD) in der Freizeit und Nacht einhergingen. Alle untersuchten Erfolgsmerkmale waren für die Gesundheit prädiktiv. So war Mitarbeiterwachstum negativ mit dem SBD während der Arbeit sowie Schlafstörungen assoziiert. Je mehr Unternehmenserfolg erlebt wurde, desto geringer waren die Werte für vitale Erschöpfung und Depression. Die Urlaubsdauer war negativ mit Angst und vitaler Erschöpfung korreliert. Insgesamt hatte von den Arbeitsmerkmalen nur die Dauer der Arbeitszeit einen Effekt auf die Gesundheit von Unternehmern. Daneben existieren aber offensichtlich weitere Faktoren, die mit der Unternehmergesundheit in Beziehung stehen. Dies sind neben dem Konkurrenzdruck am Markt insbesondere Indikatoren des Unternehmenserfolgs. The relationship between health and workload as well as entrepreneurial success was analyzed in 53 entrepreneurs. Workload data (decision latitude, job demand, working time, competition, market development) were determined by using structured interviews and Karasek's job content questionnaire. Firm success was operationalized by employee growth, the possibility of absence from the company (days of holiday), and perceived success. Health was measured by questionnaires for sleep disturbances, vital exhaustion, depression, and anxiety, and by 24 hour ambulatory blood pressure monitoring. Regression analyses showed that working time and strength of competition within the market were predictive for systolic blood pressure (SBP) during leisure time and night, but not during work. All variables measuring entrepreneurial success were predictive for health. Employee growth was related to decreasing SBP during work and to fewer sleep disturbances. The duration of holidays was negatively related to vital exhaustion and anxiety. Perceived company success was negatively related to depression and vital exhaustion. In conclusion, only the relationship between working time and bad health conformed to findings reported for the relationship between work and health in employees. However, there were additional indicators, especially indicators of competition and entrepreneurial success, that affected the health of entrepreneurs.