8 resultados para Absorption and attenuation meter AC-9
em Aston University Research Archive
Resumo:
Gastric absorption of feruloylquinic acid and di-O-caffeoylquinic acid analogs has never been investigated despite their potential contribution to the proposed beneficial health effects leading to reduced risk of type 2 diabetes. Using a cultured gastric epithelial model, with an acidic apical pH, the relative permeability coefficients (P(app)) and metabolic fate of a series of chlorogenic acids (CGAs) were investigated. Mechanistic studies were performed in the apical to basal direction and demonstrated differential rates of absorption for different CGA subgroups. For the first time, we show intact absorption of feruloylquinic acids and caffeoylquinic acid lactones across the gastric epithelium (P(app) ~ 0.2 cm/s). Transport seemed to be mainly by passive diffusion, because good linearity was observed over the incubation period and test concentrations, and we speculate that a potential carrier-mediated component may be involved in uptake of certain 4-acyl CGA isomers. In contrast, absorption of intact di-O-caffeoylquinic acids was rapid (P(app) ~ 2-10 cm/s) but nonlinear with respect to time and concentration dependence, which was potentially limited by interaction with an efflux transporter and/or pH gradient dependence. For the first time, methylation is shown in gastric mucosa. Furthermore, isoferulic acid, dimethoxycinnamic acid, and ferulic acid were identified as novel gastric metabolites of CGA biotransformation. We propose that the stomach is the first location for the release of hydroxycinnamic acids, which could explain their early detection after coffee consumption.
Resumo:
This thesis describes the study of various grating based optical fibre sensors for applications in refractive index sensing. The sensitivity of these sensors has been studied and in some cases enhanced using novel techniques. The major areas of development are as follows. The sensitivity of long period gratings (LPGs) to surrounding medium refractive index (SRI) for various periods was investigated. The most sensitive period of LPG was found to be around 160 µm and this was due to the core mode coupling to a single cladding mode but phase matching at two wavelength locations, creating two attenuation peaks, close to the waveguide dispersion turning point. Large angle tilted fibre gratings (TFGs) have similar behaviour to LPGs, in that they couple to the co-propagating cladding modes. The tilted structure of the index modulation within the core of the fibre gives rise to a polarisation dependency, differing the large angle TFG from a LPG. Since the large angle TFG couple to the cladding mode they are SRI sensitive, the sensitivity to SRI can be further increased through cladding etching using HF acid. The thinning of the cladding layer caused a reordering of the cladding modes and shifted to more SRI sensitive cladding modes as the investigation discovered. In a SRI range of 1.36 to 1.40 a sensitivity of 506.9 nm/URI was achieved for the etched large angle TFG, which is greater than the dual resonance LPG. UV inscribed LPGs were coated with sol-gel materials with high RIs. The high RI of the coating caused an increase in cladding mode effective index which in turn caused an increase in the LPG sensitivity to SRI. LPGs of various periods of LPG were coated with sol-gel TiO2 and the optimal thickness was found to vary for each period. By coating of the already highly SRI sensitive 160µm period LPG (which is a dual resonance) with a sol-gel TiO2, the SRI sensitivity was further increased with a peak value of 1458 nm/URI, which was an almost 3 fold increase compared to the uncoated LPG. LPGs were also inscribed using a femtosecond laser which produced a highly focused index change which was no uniform throughout the core of the optical fibre. The inscription technique gave rise to a large polarisation sensitivity and the ability to couple to multiple azimuthal cladding mode sets, not seen with uniform UV inscribed gratings. Through coupling of the core mode to multiple sets of cladding modes, attenuation peaks with opposite wavelength shifts for increasing SRI was observed. Through combining this opposite wavelength shifts, a SRI sensitivity was achieved greater than any single observed attenuations peak. The maximum SRI achieved was 1680 nm/URI for a femtosecond inscribed LPG of period 400 µm. Three different types of surface plasmon resonance (SPR) sensors with a multilayer metal top coating were investigated in D shape optical fibre. The sensors could be separated into two types, utilized a pre UV inscribed tilted Bragg grating and the other employed a post UV exposure to generate surface relief grating structure. This surface perturbation aided the out coupling of light from the core but also changed the sensing mechanism from SPR to localised surface plasmon resonance (LSPR). This greatly increased the SRI sensitivity, compared to the SPR sensors; with the gold coated top layer surface relief sensor producing the largest SRI sensitivity of 2111.5nm/URI was achieved. While, the platinum and silver coated top layer surface relief sensors also gave high SRI sensitivities but also the ability to produce resonances in air (not previously seen with the SPR sensors). These properties were employed in two applications. The silver and platinum surface relief devices were used as gas sensors and were shown to be capable of detecting the minute RI change of different gases. The calculated maximum sensitivities produced were 1882.1dB/URI and 1493.5nm/URI for silver and platinum, respectively. Using a DFB laser and power meter a cheap alternative approach was investigated which showed the ability of the sensors to distinguish between different gases and flow rates of those gases. The gold surface relief sensor was coated in a with a bio compound called an aptamer and it was able to detect various concentrations of a biological compound called Thrombin, ranging from 1mM to as low as 10fM. A solution of 2M NaCl was found to give the best stripping results for Thrombin from the aptamer and showed the reusability of the sensor. The association and disassociation constants were calculated to be 1.0638×106Ms-1 and 0.2482s-1, respectively, showing the high affinity of the Aptamer to thrombin. This supports existing working stating that aptamers could be alternative to enzymes for chemical detection and also helps to explain the low detection limit of the gold surface relief sensor.
Resumo:
A prominent feature of several type of cancer is cachexia. This syndrome causes a marked loss of lean body mass and muscle wasting, and appears to be mediated by cytokines and tumour products. There are several proteases and proteolytic pathways that could be responsible for the protein breakdown. In the present study, we investigated whether caspases are involved in the proteolytic process of skeletal muscle catabolism observed in a murine model of cancer cachexia (MAC16), in comparison with a related tumour (MAC13), which does not induce cachexia. Using specific peptide substrates, there was an increase of 54% in the proteolytic activity of caspase-1, 84% of caspase-8, 98% of caspase-3 151% to caspase-6 and 177% of caspase-9, in the gastrocnemius muscle of animals bearing the MAC16 tumour (up to 25% weight loss), in relation to muscle from animals bearing the MAC13 tumour (1-5% weight loss). The dual pattern of 89 kDa and 25 kDa fragmentation of poly (ADP-ribose) polymerase (PARP) occurred in the muscle samples from animals bearing the MAC16 tumour and with a high amount of caspase-like activity. Cytochrome c was present in the cytosolic fractions of gastrocnemius muscles from both groups of animals, suggesting that cytochrome c release from mitochondria may be involved in caspase activation. There was no evidence for DNA fragmentation into a nucleosomal ladder typical of apoptosis in the muscles of either group of mice. This data supports a role for caspases in the catabolic events in muscle involved in the cancer cachexia syndrome. © 2001 Cancer Research Campaign.
Resumo:
We consider non-degenerate two-wave mixing in photorefractive Bi12SiO20. It is shown theoretically that the presence of absorption and optical activity in the photorefractive media may result in a number of maxima for the gain as the frequency detuning between the two beams is varied. Further, when the beam interaction is used for optical amplification, there may also exist an optimum crystal length beyond which there is a reduction in the useful gain obtainable. Experimental results are presented in confirmation of the theory.
Resumo:
The small intestine poses a major barrier to the efficient absorption of orally administered therapeutics. Intestinal epithelial cells are an extremely important site for extrahepatic clearance, primarily due to prominent P-glycoprotein-mediated active efflux and the presence of cytochrome P450s. We describe a physiologically based pharmacokinetic model which incorporates geometric variations, pH alterations and descriptions of the abundance and distribution of cytochrome 3A and P-glycoprotein along the length of the small intestine. Simulations using preclinical in vitro data for model drugs were performed to establish the influence of P-glycoprotein efflux, cytochrome 3A metabolism and passive permeability on drug available for absorption within the enterocytes. The fraction of drug escaping the enterocyte (F(G)) for 10 cytochrome 3A substrates with a range of intrinsic metabolic clearances were simulated. Following incorporation of P-glycoprotein in vitro efflux ratios all predicted F(G) values were within 20% of observed in vivo F(G). The presence of P-glycoprotein increased the level of cytochrome 3A drug metabolism by up to 12-fold in the distal intestine. F(G) was highly sensitive to changes in intrinsic metabolic clearance but less sensitive to changes in intestinal drug permeability. The model will be valuable for quantifying aspects of intestinal drug absorption and distribution.
Resumo:
We consider non-degenerate two-wave mixing in photorefractive Bi12SiO20. It is shown theoretically that the presence of absorption and optical activity in the photorefractive media may result in a number of maxima for the gain as the frequency detuning between the two beams is varied. Further, when the beam interaction is used for optical amplification, there may also exist an optimum crystal length beyond which there is a reduction in the useful gain obtainable. Experimental results are presented in confirmation of the theory.