38 resultados para ANGLE-RESOLVED PHOTOEMISSION
em Aston University Research Archive
Resumo:
Mechanical, physical and chemical changes in the surface of commercial thin film metal evaporated magnetic recording media have been correlated to recording error and signal degradation measurements. Modified and adapted commercial Hi-8 video recorders have been used for sample generation whilst analytical techniques such as SXPS,IMS and SEM have been employed in the surface characterisation. The durability of the media was assessed through stop motion (still frame) and cycling tests, where error growth and signal degradation were measured as a function of running time. The tests were performed under ambient (22°C, 40% RH) and high humidity (22°C, 80% RH) conditions. Characterisation of the lubricant layer on each tape was performed through models based on XPS and angle resolved XPS. The lubricant thickness can significantly affect the durability and signal output level of a thin film tape and thus it is important that reliable quantification can be achieved. Various models were considered for determining the lubricant thickness although ultimately, the most suitable technique was deemed to be a model that assumed a uniform layer structure. In addition to thin film metal evaporated media, equivalent durability tests and surface analysis experiments were performed using a commercial metal particle tape in order that comparisons could be made between the two types of recording media. The signal performance of the thin film metal evaporated media was found to be quite different from that for the metal particle tape since dropout errors and signal degradation increased at a much earlier stage. Extensive surface analyses enabled the mechanisms responsible for media failure and error growth to be identified in the ME and MP tapes and these were found to result from cyclic stressing and fatigue on the immediate substrate of the media.
Resumo:
Recent work has highlighted the potential of sol-gel-derived calcium silicate glasses for the regeneration or replacement of damaged bone tissue. The work presented herein provides new insight into the processing of bioactive calcia-silica sol-gel foams, and the reaction mechanisms associated with them when immersed in vitro in a simulated body fluid (SBF). Small-angle X-ray scattering and wide-angle X-ray scattering (diffraction) have been used to study the stabilization of these foams via heat treatment, with analogous in situ time-resolved data being gathered for a foam immersed in SBF. During thermal processing, pore sizes have been identified in the range of 16.5-62.0 nm and are only present once foams have been heated to 400 degrees C and above. Calcium nitrate crystallites were present until foams were heated to 600 degrees C; the crystallite size varied from 75 to 145 nm and increased in size with heat treatment up to 300 degrees C, then decreased in size down to 95 rim at 400 degrees C. The in situ time-resolved data show that the average pore diameter decreases as a function of immersion time in SBF, as calcium phosphates grow on the glass surfaces. Over the same time, Bragg peaks indicative of tricalcium phosphate were evident after only 1-h immersion time, and later, hydroxycarbonate apatite was also seen. The hydroxycarbonate apatite appears to have preferred orientation in the (h,k,0) direction.
Resumo:
PURPOSE. To assess the level of plasma glutathione in patients with untreated primary open-angle glaucoma. METHODS. Twenty-one patients with newly diagnosed primary open-angle glaucoma and 34 age- and gender-matched control subjects were subjected to a blood analysis to detect the level of circulating glutathione in its reduced and oxidized forms. The effect of age, gender, and systemic blood pressure on circulating glutathione levels was also analyzed. RESULTS. Age had a negative effect on the level of both reduced and total glutathione (P = 0.002, r = -0.52 and P = 0.002, r = -0.52, respectively) in control subjects but not in patients with glaucoma (P > 0.05, r = 0.27, and P > 0.05, r = 0.22, respectively). In the control group, men demonstrated higher levels of both reduced and total glutathione than did women (P = 0.024 and P = 0.032, respectively). After correction for age and gender influences on blood glutathione levels, patients with glaucoma exhibited significantly lower levels of reduced and total glutathione than did control subjects (P = 0.010, F = 7.24 and P = 0.006, F = 8.38, respectively). No differences between study groups were observed in either oxidized glutathione levels or redox index (P > 0.05, F = 0.50; and P > 0.05, F = 0.30, respectively). CONCLUSIONS. Patients with glaucoma exhibit low levels of circulating glutathione, suggesting a general compromise of the antioxidative defense. Copyright © Association for Research in Vision and Ophthalmology.
Resumo:
To investigate the relationship between the occurrence of transient cardiac ischaemic episodes and variations in the ambulatory 24-h blood pressure and heart rate measurements in a group of unselected glaucoma patients.
Resumo:
Purpose To evaluate the effect of latanoprost 0.005% on the optic nerve head (ONH) and retinal circulation of newly diagnosed and previously untreated primary open-angle glaucoma (POAG) patients. Methods Twenty-two newly diagnosed and previously untreated POAG patients (mean age±SD: 68.38±11.92 years) were included in this longitudinal open-label study. Patients were treated with latanoprost 0.005% once a day. Intraocular pressure (IOP), systemic blood pressure (BP), mean ocular perfusion pressure (MOPP), and ocular perfusion parameters ‘volume’, ‘velocity’, and ‘flow’ measured at the optic nerve head (ONH) and retina by means of Heidelberg Retina Flowmeter system were evaluated during a 6-month follow-up period. Results Treatment with latanoprost 0.005% resulted in a significant decrease in IOP (P<0.0001) and increase in MOPP (P<0.0001). After correcting for changes in MOPP, the blood velocity measured at the ONH level was significantly higher after 6 months of treatment than at baseline (P=0.0310). In addition, blood volume and flow measured at the peripapillary retina level improved after 3 and 6 months of treatment (P=0.0170; P=0.0260, and P=0.0170; P=0.0240 respectively). Conclusion Previously untreated POAG patients exhibit reduced IOP, increased MOPP and improved ocular perfusion at the ONH and retina levels when treated with Latanoprost 0.005%. These effects could be beneficial for glaucoma patients suffering from ocular vascular dysregulation.
Autonomic dysfunction in unselected and untreated primary open angle glaucoma patients:A pilot study
Resumo:
Purpose: To investigate the presence of silent cardiac ischaemic episodes and the status of autonomic function in consecutive, newly diagnosed and untreated primary open-angle glaucoma patients. Methods: Twenty-four consecutively diagnosed glaucoma patients and 22 age-matched controls were subjected to ambulatory 24-h blood pressure (BP) and electrocardiogram (ECG) monitoring by using Cardiotens-01 (Meditech Ltd). Based on the ECG recordings, heart rate variability (HRV) frequency domain parameters [low-frequency (LF), high-frequency (HF) and LF/HF ratio] were calculated and analysed in the two study groups. Results: Glaucoma patients demonstrated higher LF and LF/HF values than normal subjects for both the active period (p = 0.020 and 0.029) and the passive period (p = 0.044 and 0.049 respectively). HRV parameters were similar in patients and controls suffering from silent cardiac ischaemia (p > 0.05); however, glaucoma patients with normal ECG demonstrated higher LF and LF/HF values during the active period of the 24-h measurement period than control subjects characterized by the same cardiac activity (p = 0.010 and 0.021 respectively). Conclusion: Independent of a history and/or clinical signs of cardiovascular disease, glaucoma patients exhibit abnormal autonomic function. © 2007 The Authors.
Resumo:
A typical liquid state NMR spectrum is composed of a number of discrete absorptions which can be readily interpreted to yield detailed information about the chemical environment of the nuclei found within the sample. The same cannot be said about the spectra of solid samples. For these the absorptions are typically broad, featureless and yield little information directly. This situation may be further exacerbated by the characteristically long T1 values of nuclei bound within a solid lattice which, consequently, require long inter-sequence delays that necessitate lengthy experiments. This work attempts to address both of these inherent problems. Classically, the resolution of the broad-line spectra of solids into discrete resonances has been achieved by imparting to the sample coherent rotation about specific axes in relation to the polarising magnetic field, as implemented in the magic-angle spinning (MAS) [1], dynamic angle spinning (DAS) [2] and double rotation (DOR) [3] NMR experiments. Recently, an alternative method, sonically induced narrowing of the NMR spectra of solids (SINNMR) [4], has been reported which yields the same well resolved solid-state spectra as the classic solid-state NMR experiments, but which achieves the resolution of the broad-line spectra through the promotion of incoherent motion in a suspension of solid particles. The first part of this work examines SINNMR and, in particular, concentrates on ultrasonically induced evaluation, a phenomenon which is thought to be essential to the incoherent averaging mechanism. The second part of this work extends the principle of incoherent motion, implicit in SINNMR, to a new genre of particulate systems, air fluidized beds, and examines the feasibility of such systems to provide well resolved solid state NMR spectra. Samples of trisodium phosphate dodecahydrate and of aluminium granules are examined using the new method with partially resolved spectra being reported in the case of the latter.
Resumo:
We report for the first time forward propagating cladding modes coupling by using tilted gratings. The spectral responses of these gratings were investigated and their thermal characteristics and sensitivity to environmental refractive index were evaluated.
Resumo:
The study utilised a Normal group, an Ocular Hypertensive (OHT) group and a Primary Open Angle Glaucoma (POAG) group to investigate two aspects. Firstly, the within- and between-visit variability for stereometric measurements of the optic nerve head (ONH) using the Heidelberg Retina Tomograph (HRT); retinal nerve fibre layer (RNFL) thickness using the HRT and using optical coherence tomography with the Optical Coherence Tomography Scanner (OCT); the visual field using white-on-white (W-W), short-wavelength (SWAP) and Frequency Doubling perimetry (FDT); and retinal haemodynamics using the Heidelberg Retinal Flowmeter (HRF). Secondly, the association demonstrated between some of the derived variables. The within- and between-visit variability for stereometric measurements of the entire ONH and the between-visit variability for sectoral measurements were similar for Normals and OHTs but greater for POAGs. The within-visit variability of the visual field pointwise parameters for SWAP were greater than for W-W and FDT particularly with increase in eccentricity and for the OHT group. The between-visit variability increased with increase in defect depth for the POAG group, across all types of perimetry. The MS was greater, the MD and PSD smaller and the examination duration shorter in FDT compared to W-W and SWAP across all groups. The within-visit variability was less than the between-visit variability for the OCT circumferential and sector RNFL thickness using the 1.5R, 2.0R and the fixed 1.73mm circular scan radii, across the three groups. The variability increased with decrease in the RNFL thickness, and was least for the 2.0R scan radius.
Resumo:
Purpose: Dynamic contact angle (DCA) methods have advantages over other contact angle methodologies, not least that they can provide more than single contact angle values. Here we illustrate the use of DCA analysis to provide “fingerprint” characterisation of contact lens surfaces, and the way that different materials change in the early stages of wear. Method: The DCA method involves attaching to a microbalance weighted strips cut from a lens. The strips are then cyclically inserted into and removed from an aqueous solution. Conventionally, readings of force taken from linear portions of the resultant dipping curves are translated into advancing (CAa) and receding contact (CAr) angles. Additionally, analysis of the force versus immersion profile provides a “fingerprint” characterisation of the state of the lens surface. Results: CAa and CAr values from DCA traces provide a useful means of differentiating gross differences in hydrophilicity and molecular mobility of surfaces under particular immersion and emersion conditions, such as dipping rate and dwell times. Typical values for etafilcon A (CAa:63.1; CAr:37) and balafilcon B (CAa:118.4; CAr:36.4) illustrate this. Surface modifications induced in lens manufacture are observed to produce not only changes in these value, which may be small, but also changes in the DCA “fingerprint” (slope, undulations, length of plateau). Interestingly, similar changes are induced in the first few hours of lens wear with some lens-patient combinations. Conclusions: Although single parameter contact angles are useful for material characterisation, information of potential clinical interest can be obtained from more detailed analysis of DCA traces.
Resumo:
The influence of ionic strength and of the chemical nature of cations on the protein-protein interactions in ovalbumin solution was studied using small-angle X-ray and neutron scattering (SAXS/SANS). The globular protein ovalbumin is found in dimeric form in solutions as suggested by SANS/SAXS experiments. Due to the negative charge of the proteins at neutral pH, the protein-protein interactions without any salt addition are dominated by electrostatic repulsion. A structure factor related to screened Coulombic interactions together with an ellipsoid form factor was used to fit the scattering intensity. A monovalent salt (NaCl) and a trivalent salt (YCl3) were used to study the effect of the chemical nature of cations on the interaction in protein solutions. Upon addition of NaCl, with ionic strength below that of physiological conditions (150 mM), the effective interactions are still dominated by the surface charge of the proteins and the scattering data can be understood using the same model. When yttrium chloride was used, a reentrant condensation behavior, i.e., aggregation and subsequent redissolution of proteins with increasing salt concentration, was observed. SAXS measurements reveal a transition from effective repulsion to attraction with increasing salt concentration. The solutions in the reentrant regime become unstable after long times (several days). The results are discussed and compared with those from bovine serum albumin (BSA) in solutions.
Resumo:
Purpose: To report the outcome of retinal artery macroaneurysm associated with a congenital anomalous retinal artery. Methods: The patient was examined with ophthalmoscopy and fluorescein angiography. Results: A 60-year-old woman presented with visual acuity of 20/80 in her right eye. She was found to have an abnormal retinal vessel emerging from the optic disk, passing toward the center of the macula, and looping back toward the disk. The center of the loop had a leaking macroaneurysm, which was treated conservatively. At the 4-month follow-up visit, the visual acuity in the right eye had improved to 20/20 with resolution of most of the macular edema, exudates, and hemorrhage. Conclusion: This case demonstrates that retinal artery macroaneurysm can be successfully managed with a conservative approach, even when associated with a congenital anomalous retinal vessel.