8 resultados para 917
em Aston University Research Archive
Resumo:
Researchers often use 3-way interactions in moderated multiple regression analysis to test the joint effect of 3 independent variables on a dependent variable. However, further probing of significant interaction terms varies considerably and is sometimes error prone. The authors developed a significance test for slope differences in 3-way interactions and illustrate its importance for testing psychological hypotheses. Monte Carlo simulations revealed that sample size, magnitude of the slope difference, and data reliability affected test power. Application of the test to published data yielded detection of some slope differences that were undetected by alternative probing techniques and led to changes of results and conclusions. The authors conclude by discussing the test's applicability for psychological research. Copyright 2006 by the American Psychological Association.
Resumo:
The importance of informal institutions and in particular culture for entrepreneurship is a subject of ongoing interest. Past research has mostly concentrated on cross-national comparisons, cultural values and the direct effects of culture on entrepreneurial behaviour, but in the main found inconsistent results. We add a fresh perspective to this research stream by turning attention to community-level culture and cultural norms. We hypothesize indirect effects of cultural norms on venture emergence: Community-level cultural norms (performance-based culture and socially supportive institutional norms) impact important supply-side variables (entrepreneurial self-efficacy and entrepreneurial motivation) which in turn influence nascent entrepreneurs' success in creating operational ventures (venture emergence). We test our predictions on a unique longitudinal dataset, tracking nascent entrepreneurs' venture creation efforts over a five-year time span, and find evidence supporting them. Our research contributes to a more fine-grained understanding of how culture, in particular perceptions of community cultural norms, influences venture emergence. Based on these findings, we discuss how venture creation efforts can be supported. Our research highlights the embeddedness of entrepreneurial behaviour and its immediate antecedent beliefs in the local, community context. © 2012 Copyright Taylor and Francis Group, LLC.
Resumo:
Objective of the study To determine the extent and nature of unlicensed/off-label prescribing patterns in hospitalised children in Palestine. Setting Four paediatric wards in two public health system hospitals in Palestine [Caritas children’s hospital (Medical and neonatal intensive care units) and Rafidia general hospital (Medical and surgical units)]. Method A prospective survey of drugs administered to infants and children <18 years old was carried out over a five-week period in the four paediatric wards. Main outcome measure Drug-licensing status of all prescriptions was determined according to the Palestinian Registered Product List and the Physician’s Desk Reference. Results Overall, 917 drug prescriptions were administered to 387children. Of all drug prescriptions, 528 (57.5%) were licensed for use in children; 65 (7.1%) were unlicensed; and 324 (35.3%) were used off-label. Of all children, 49.6% received off-label prescriptions, 10.1% received unlicensed medications and 8.2% received both. Seventy-two percent of off-label drugs and 66% of unlicensed drugs were prescribed for children <2 years. Multivariate analysis showed that patients who were admitted to the neonatal intensive care unit and infants aged 0–1 years were most likely to receive a greater number of off-label or unlicensed medications (OR 1.80; 95% CI 1.03–3.59 and OR 1.99; 95% CI 0.88–3.73, respectively). Conclusion The present findings confirmed the elevated prevalence of unlicensed and off-label paediatric drugs use in Palestine and strongly support the need to perform well designed clinical studies in children.
Resumo:
In the Paramecium tetraurelia genome, 17 genes encoding the 100-kDa-subunit (a-subunit) of the vacuolar-proton-ATPase were identified, representing by far the largest number of a-subunit genes encountered in any organism investigated so far. They group into nine clusters, eight pairs with >82% amino acid identity and one single gene. Green fluorescent protein-tagging of representatives of the nine clusters revealed highly specific targeting to at least seven different compartments, among them dense core secretory vesicles (trichocysts), the contractile vacuole complex, and phagosomes. RNA interference for two pairs confirmed their functional specialization in their target compartments: silencing of the trichocyst-specific form affected this secretory pathway, whereas silencing of the contractile vacuole complex-specific form altered organelle structure and functioning. The construction of chimeras between selected a-subunits surprisingly revealed the targeting signal to be located in the C terminus of the protein, in contrast with the N-terminal targeting signal of the a-subunit in yeast. Interestingly, some chimeras provoked deleterious effects, locally in their target compartment, or remotely, in the compartment whose specific a-subunit N terminus was used in the chimera.
Resumo:
We report the first experimental demonstration of single transmissive fiber Bragg grating implementation of a first-order optical differentiation. The device has been designed and fabricated, and the experimental results show a good performance over an operational bandwidth of ∼2 nm. © 2013 Optical Society of America.
Resumo:
AIM: To determine the force needed to extract a drop from a range of current prostaglandin monotherapy eye droppers and how this related to the comfortable and maximum pressure subjects could exert. METHODS: The comfortable and maximum pressure subjects could apply to an eye dropper constructed around a set of cantilevered pressure sensors and mounted above their eye was assessed in 102 subjects (mean 51.2±18.7 years), repeated three times. A load cell amplifier, mounted on a stepper motor controlled linear slide, was constructed and calibrated to test the force required to extract the first three drops from 13 multidose or unidose latanoprost medication eye droppers. RESULTS: The pressure that could be exerted on a dropper comfortably (25.9±17.7 Newtons, range 1.2-87.4) could be exceeded with effort (to 64.8±27.1 Newtons, range 19.9-157.8; F=19.045, p<0.001), and did not differ between repeats (F=0.609, p=0.545). Comfortable and maximum pressures exerted were correlated (r=0.618, p<0.001), neither were influenced strongly by age (r=0.138, p=0.168; r=-0.118, p=0237, respectively), but were lower in women than in men (F=12.757, p=0.001). The force required to expel a drop differed between dropper designs (F=22.528, p<0.001), ranging from 6.4 Newtons to 23.4 Newtons. The force needed to exert successive drops increased (F=36.373, p<0.001) and storing droppers in the fridge further increased the force required (F=7.987, p=0.009). CONCLUSIONS: Prostaglandin monotherapy droppers for glaucoma treatment vary in their resistance to extract a drop and with some a drop could not be comfortably achieved by half the population, which may affect compliance and efficacy.
Resumo:
Aim: To validate the accuracy and repeatability of a mobile app reading speed test compared with the traditional paper version. Method: Twenty-one subjects wearing their full refractive correction glasses read 14 sentences of decreasing print size between 1.0 and -0.1 logMAR, each consisting of 14 words (Radner reading speed test) at 40 cm with a paper-based chart and twice on iPad charts. Time duration was recorded with a stop watch for the paper chart and on the App itself for the mobile chart allowing critical print size (CPS) and optimal reading speed (ORS) to be derived objectively. Results: The ORS was higher for the mobile app charts (194±29 wpm; 195±25 wpm) compared with the paper chart (166±20 wpm; F=57.000, p<0.001). The CPS was lower for the mobile app charts (0.17±0.20 logMAR; 0.18±0.17 logMAR) compared with the paper chart (0.25±0.17 logMAR; F=5.406, p=0.009). The mobile app test had a mean difference repeatability of 0.30±22.5 wpm, r=0.917 for ORS, and a CPS of 0.0±0.2 logMAR, r=0.769. Conclusions: Repeatability of the app reading speed test is as good (ORS) or better (CPS) than previous studies on the paper test. While the results are not interchangeable with paper-based charts, mobile app tablet-based tests of reading speed are reliable and rapid to perform, with the potential to capture functional visual ability in research studies and clinical practice.
Resumo:
Presbyopia is a consequence of ageing and is therefore increasing inprevalence due to an increase in the ageing population. Of the many methods available to manage presbyopia, the use of contact lenses is indeed a tried and tested reversible option for those wishing to be spectacle free. Contact lens options to correct presbyopia include multifocal contact lenses and monovision.Several options have been available for many years with available guides to help choose multifocal contact lenses. However there is no comprehensive way to help the practitioner selecting the best option for an individual. An examination of the simplest way of predicting the most suitable multifocal lens for a patient will only enhance and add to the current evidence available. The purpose of the study was to determine the current use of presbyopic correction modalities in an optometric practice population in the UK and to evaluate and compare the optical performance of four silicone hydrogel soft multifocal contact lenses and to compare multifocal performance with contact lens monovision. The presbyopic practice cohort principal forms of refractive correction were distance spectacles (with near and intermediate vision providedby a variety of other forms of correction), varifocal spectacles and unaided distance with reading spectacles, with few patients wearing contact lenses as their primary correction modality. The results of the multifocal contact lens randomised controlled trial showed that there were only minor differences in corneal physiology between the lens options. Visual acuity differences were observed for distance targets, but only for low contrast letters and under mesopic lighting conditions. At closer distances between 20cm and 67cm, the defocus curves demonstrated that there were significant differences in acuity between lens designs (p < 0.001) and there was an interaction between the lens design and the level of defocus (p < 0.001). None of the lenses showed a clear near addition, perhaps due to their more aspheric rather than zoned design. As expected, stereoacuity was reduced with monovision compared with the multifocal contact lens designs, although there were some differences between the multifocal lens designs (p < 0.05). Reading speed did not differ between lens designs (F = 1.082, p = 0.368), whereas there was a significant difference in critical print size (F = 7.543, p < 0.001). Glare was quantified with a novel halometer and halo size was found to significantly differ between lenses(F = 4.101, p = 0.004). The rating of iPhone image clarity was significantly different between presbyopic corrections (p = 0.002) as was the Near Acuity Visual Questionnaire (NAVQ) rating of near performance (F = 3.730, p = 0.007).The pupil size did not alter with contact lens design (F = 1.614, p = 0.175), but was larger in the dominant eye (F = 5.489, p = 0.025). Pupil decentration relative to the optical axis did not alter with contact lens design (F = 0.777, p =0.542), but was also greater in the dominant eye (F = 9.917, p = 0.003). It was interesting to note that there was no difference in spherical aberrations induced between the contact lens designs (p > 0.05), with eye dominance (p > 0.05) oroptical component (ocular, corneal or internal: p > 0.05). In terms of subjective patient lens preference, 10 patients preferred monovision,12 Biofinity multifocal lens, 7 Purevision 2 for Presbyopia, 4 AirOptix multifocal and 2 Oasys multifocal contact lenses. However, there were no differences in demographic factors relating to lifestyle or personality, or physiological characteristics such as pupil size or ocular aberrations as measured at baseline,which would allow a practitioner to identify which lens modality the patient would prefer. In terms of the performance of patients with their preferred lens, it emerged that Biofinity multifocal lens preferring patients had a better high contrast acuity under photopic conditions, maintained their reading speed at smaller print sizes and subjectively rated iPhone clarity as better with this lens compared with the other lens designs trialled. Patients who preferred monovision had a lower acuity across a range of distances and a larger area of glare than those patients preferring other lens designs that was unexplained by the clinical metrics measured. However, it seemed that a complex interaction of aberrations may drive lens preference. New clinical tests or more diverse lens designs which may allow practitioners to prescribe patients the presbyopic contact lens option that will work best for them first time remains a hope for the future.