4 resultados para 854

em Aston University Research Archive


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To perform advanced analysis of the corneal deformation response to air pressure in keratoconics compared with age- and sex-matched controls. METHODS: The ocular response analyzer was used to measure the air pressure-corneal deformation relationship of 37 patients with keratoconus and 37 age (mean 36 ± 10 years)- and sex-matched controls with healthy corneas. Four repeat air pressure-corneal deformation profiles were averaged, and 42 separate parameters relating to each element of the profiles were extracted. Corneal topography and pachymetry were performed with the Orbscan II. The severity of the keratoconus was graded based on a single metric derived from anterior corneal curvatures, difference in astigmatism in each meridian, anterior best-fit sphere, and posterior best-fit sphere. RESULTS: Most of the biomechanical characteristics of keratoconic eyes were significantly different from normal eyes (P <0.001), especially during the initial corneal applanation. With increasing keratoconus severity, the cornea was thinner (r = -0.407, P <0.001), the speed of corneal concave deformation past applanation was quicker (dive; r = -0.314, P = 0.01), and the tear film index was lower (r = -0.319, P = 0.01). The variance in keratoconus severity could be accounted for by the corneal curvature and central corneal thickness (r = 0.80) with biomechanical characteristics contributing an additional 4% (total r = 0.84). The area under the receiver operating characteristic curve was 0.919 ± 0.025 for keratometry alone, 0.965 ± 0.014 with the addition of pachymetry, and 0.972 ± 0.012 combined with ocular response analyzer biomechanical parameters. CONCLUSIONS: Characteristics of the air pressure-corneal deformation profile are more affected by keratoconus than the traditionally extracted corneal hysteresis and corneal resistance factors. These biomechanical metrics slightly improved the detection and severity prediction of keratoconus above traditional keratometric and pachymetric assessment of corneal shape.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relationship between organizational networks and employees' affect was examined in 2 organizations. In Study 1, social network analysis of work ties and job-related affect for 259 employees showed that affect converged within work interaction groups. Similarity of affect between employees depended on the presence of work ties and structural equivalence. Affect was also related to the size and density of employees' work networks. Study 2 used a 10-week diary study of 31 employees to examine a merger of 2 organizational divisions and found that negative changes in employees' affect were related to having fewer cross-divisional ties and to experiencing greater reductions in network density. The findings suggest that affect permeates through and is shaped by organizational networks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To analyse the relationship between measured intraocular pressure (IOP) and central corneal thickness (CCT), corneal hysteresis (CH) and corneal resistance factor (CRF) in ocular hypertension (OHT), primary open-angle (POAG) and normal tension glaucoma (NTG) eyes using multiple tonometry devices. Methods: Right eyes of patients diagnosed with OHT (n=47), normal tension glaucoma (n=17) and POAG (n=50) were assessed, IOP was measured in random order with four devices: Goldmann applanation tonometry (GAT); Pascal(R) dynamic contour tonometer (DCT); Reichert(R) ocular response analyser (ORA); and Tono-Pen(R) XL. CCT was then measured using a hand-held ultrasonic pachymeter. CH and CRF were derived from the air pressure to corneal reflectance relationship of the ORA data. Results: Compared to the GAT, the Tonopen and ORA Goldmann equivalent (IOPg) and corneal compensated (IOPcc) measured higher IOP readings (F=19.351, p<0.001), particularly in NTG (F=12.604, p<0.001). DCT was closest to Goldmann IOP and had the lowest variance. CCT was significantly different (F=8.305, p<0.001) between the 3 conditions as was CH (F=6.854, p=0.002) and CRF (F=19.653, p<0.001). IOPcc measures were not affected by CCT. The DCT was generally not affected by corneal biomechanical factors. Conclusion: This study suggests that as the true pressure of the eye cannot be determined non-invasively, measurements from any tonometer should be interpreted with care, particularly when alterations in the corneal tissue are suspected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ramipril is used mainly for the treatment of hypertension and to reduce incidence of fatality following heart attacks in patients who develop indications of congestive heart failure. In the paediatric population it is used most commonly for the treatment of heart failure, hypertension in type 1 diabetes and diabetic nephropathy. Due to the lack of a suitable liquid formulation, the current study evaluates the development of a range of oral liquid formulations of ramipril along with their in vitro and in vivo absorption studies. Three different formulation development approaches were studied: solubilisation using acetic acid as a co-solvent, complexation with hydroxypropyl-β-cyclodextrin (HP-β-CD) and suspension development using xanthan gum. Systematic optimisation of formulation parameters for the different strategies resulted in the development of products stable for twelve months at long term stability conditions. In vivo evaluation showed CMAX of 10.48 µg/mL for co-solvent, 13.04µg/ml for the suspension and 29.58µg/mL for the cyclodextrin based ramipril solution. Interestingly, both ramipril solution (co-solvent) and the suspension showed a TMAX of 2.5h, however, cyclodextrin based ramipril produced TMAX at 0.75h following administration. The results presented in this study provide translatable products for oral liquid ramipril which offer preferential paediatric use over existing alternatives.