7 resultados para 59.19(79.8)
em Aston University Research Archive
Resumo:
BACKGROUND: The use of quality of life (QoL) instruments in menorrhagia research is increasing but there is concern that not enough emphasis is placed on patient-focus in these measurements, i.e. on issues which are of importance to patients and reflect their experiences and concerns (clinical face validity). The objective was to assess the quality of QoL instruments in studies of menorrhagia. STUDY DESIGN: A systematic review of published research. Papers were identified through MEDLINE (1966-April 2000), EMBASE (1980-April 2000), Science Citation Index (1981-April 2000), Social Science Citation Index (1981-April 2000), CINAHL (1982-1999) and PsychLIT (1966-1999), and by manual searching of bibliographies of known primary and review articles. Studies were selected if they assessed women with menorrhagia for life quality, either developing QoL instruments or applying them as an outcome measure. Selected studies were assessed for quality of their QoL instruments, using a 17 items checklist including 10 items for clinical face validity (issues of relevance to patients' expectations and concerns) and 7 items for measurement properties (such as reliability, responsiveness, etc.). RESULTS: A total of 19 articles, 8 on instrument development and 11 on application, were included in the review. The generic Short Form 36 Health Survey Questionnaire (SF36) was used in 12/19 (63%) studies. Only two studies developed new specific QoL instruments for menorrhagia but they complied with 7/17 (41%) and 10/17 (59%) of the quality criteria. Quality assessment showed that only 7/19 (37%) studies complied with more than half the criteria for face validity whereas 17/19 (90%) studies complied with more than half of the criteria for measurement properties (P = 0.0001). CONCLUSION: Among existing QoL instruments, there is good compliance with the quality criteria for measurement properties but not with those for clinical face validity. There is a need to develop methodologically sound disease specific QoL instruments in menorrhagia focussing both on face validity and measurement properties.
Resumo:
BACKGROUND: The use of quality of life (QoL) instruments in menorrhagia research is increasing but there is concern that not enough emphasis is placed on patient-focus in these measurements, i.e. on issues which are of importance to patients and reflect their experiences and concerns (clinical face validity). The objective was to assess the quality of QoL instruments in studies of menorrhagia. STUDY DESIGN: A systematic review of published research. Papers were identified through MEDLINE (1966-April 2000), EMBASE (1980-April 2000), Science Citation Index (1981-April 2000), Social Science Citation Index (1981-April 2000), CINAHL (1982-1999) and PsychLIT (1966-1999), and by manual searching of bibliographies of known primary and review articles. Studies were selected if they assessed women with menorrhagia for life quality, either developing QoL instruments or applying them as an outcome measure. Selected studies were assessed for quality of their QoL instruments, using a 17 items checklist including 10 items for clinical face validity (issues of relevance to patients' expectations and concerns) and 7 items for measurement properties (such as reliability, responsiveness, etc.). RESULTS: A total of 19 articles, 8 on instrument development and 11 on application, were included in the review. The generic Short Form 36 Health Survey Questionnaire (SF36) was used in 12/19 (63%) studies. Only two studies developed new specific QoL instruments for menorrhagia but they complied with 7/17 (41%) and 10/17 (59%) of the quality criteria. Quality assessment showed that only 7/19 (37%) studies complied with more than half the criteria for face validity whereas 17/19 (90%) studies complied with more than half of the criteria for measurement properties (P = 0.0001). CONCLUSION: Among existing QoL instruments, there is good compliance with the quality criteria for measurement properties but not with those for clinical face validity. There is a need to develop methodologically sound disease specific QoL instruments in menorrhagia focussing both on face validity and measurement properties.
Resumo:
The focus of this research was defined by a poorly characterised filtration train employed to clarify culture broth containing monoclonal antibodies secreted by GS-NSO cells: the filtration train blinded unpredictably and the ability of the positively charged filters to adsorb DNA from process material was unknown. To direct the development of an assay to quantify the ability of depth filters to adsorb DNA, the molecular weight of DNA from a large-scale, fed-batch, mammalian cell culture vessel was evaluated as process material passed through the initial stages of the purification scheme. High molecular weight DNA was substantially cleared from the broth after passage through a disc stack centrifuge and the remaining low molecular weight DNA was largely unaffected by passage through a series of depth filters and a sterilising grade membrane. Removal of high molecular weight DNA was shown to be coupled with clarification of the process stream. The DNA from cell culture supernatant showed a pattern of internucleosomal cleavage of chromatin when fractionated by electrophoresis but the presence of both necrotic and apoptotic cells throughout the fermentation meant that the origin of the fragmented DNA could not be unequivocally determined. An intercalating fluorochrome, PicoGreen, was elected for development of a suitable DNA assay because of its ability to respond to low molecular weight DNA. It was assessed for its ability to determine the concentration of DNA in clarified mammalian cell culture broths containing pertinent monoclonal antibodies. Fluorescent signal suppression was ameliorated by sample dilution or by performing the assay above the pI of secreted IgG. The source of fluorescence in clarified culture broth was validated by incubation with RNase A and DNase I. At least 89.0 % of fluorescence was attributable to nucleic acid and pre-digestion with RNase A was shown to be a requirement for successful quantification of DNA in such samples. Application of the fluorescence based assay resulted in characterisation of the physical parameters governing adsorption of DNA by various positively charged depth filters and membranes in test solutions and the DNA adsorption profile of the manufacturing scale filtration train. Buffers that reduced or neutralised the depth filter or membrane charge, and those that impeded hydrophobic interactions were shown to affect their operational capacity, demonstrating that DNA was adsorbed by a combination of electrostatic and hydrophobic interactions. Production-scale centrifugation of harvest broth containing therapeutic protein resulted in the reduction of total DNA in the process stream from 79.8 μg m1-1 to 9.3 μg m1-1 whereas the concentration of DNA in the supernatant of pre-and post-filtration samples had only marginally reduced DNA content: from 6.3 to 6.0 μg m1-1 respectively. Hence the filtration train was shown to ineffective in DNA removal. Historically, blinding of the depth filters had been unpredictable with data such as numbers of viable cells, non-viable cells, product titre, or process shape (batch, fed-batch, or draw and fill) failing to inform on the durability of depth filters in the harvest step. To investigate this, key fouling contaminants were identified by challenging depth filters with the same mass of one of the following: viable healthy cells, cells that had died by the process of apoptosis, and cells that had died through the process of necrosis. The pressure increase across a Cuno Zeta Plus 10SP depth filter was 2.8 and 16.5 times more sensitive to debris from apoptotic and necrotic cells respectively, when compared to viable cells. The condition of DNA released into the culture broth was assessed. Necrotic cells released predominantly high molecular weight DNA in contrast to apoptotic cells which released chiefly low molecular weight DNA. The blinding of the filters was found to be largely unaffected by variations in the particle size distribution of material in, and viscosity of, solutions with which they were challenged. The exceptional response of the depth filters to necrotic cells may suggest the cause of previously noted unpredictable filter blinding whereby a number of necrotic cells have a more significant impact on the life of a depth filter than a similar number of viable or apoptotic cells. In a final set of experiments the pressure drop caused by non-viable necrotic culture broths which had been treated with DNase I or benzonase was found to be smaller when compared to untreated broths: the abilities of the enzyme treated cultures to foul the depth filter were reduced by 70.4% and 75.4% respectively indicating the importance of DNA in the blinding of the depth filter studied.
Resumo:
Background: Management of type 2 diabetes with metformin often does not provide adequate glycemic control, thereby necessitating add-on treatment. In a 24-week clinical trial, dapagliflozin, an investigational sodium glucose cotransporter 2 inhibitor, improved glycemic control in patients inadequately controlled with metformin. The present study is an extension that was undertaken to evaluate dapagliflozin as long-term therapy in this population.Methods: This was a long-term extension (total 102 weeks) of a 24-week phase 3, multicenter, randomized, placebo-controlled, double-blind, parallel-group trial. Patients were randomly assigned (1:1:1:1) to blinded daily treatment (placebo, or dapagliflozin 2.5 to 5, or 10 mg) plus open-label metformin (=1,500 mg). The previously published primary endpoint was change from baseline in glycated hemoglobin (HbA1c) at 24 weeks. This paper reports the follow-up to week 102, with analysis of covariance model performed at 24 weeks with last observation carried forward; a repeated measures analysis was utilized to evaluate changes from baseline in HbA1c, fasting plasma glucose (FPG), and weight.Results: A total of 546 patients were randomized to 1 of the 4 treatments. The completion rate for the 78-week double-blind extension period was lower for the placebo group (63.5%) than for the dapagliflozin groups (68.3% to 79.8%). At week 102, mean changes from baseline HbA1c (8.06%) were +0.02% for placebo compared with -0.48% (P = 0.0008), -0.58% (P
Resumo:
ε-caprolactam is a monomer of high value. Therefore, the chemical reutilization of polyamide 6 containing carpets for ε-caprolactam recovery offers some economic benefit and is performed on a technical scale with the help of the Zimmer-process. By this process polyamide 6 is depolymerized with steam and phosphoric acid. An alternative to this process is the thermal depolymerization - catalyzed or non-catalyzed. To investigate this alternative in more detail, the formal kinetic parameters of (i) the thermal depolymerization of polyamide 6, (ii) the thermal depolymerization in presence of sodium/potassium hydoxide, and (iii) the thermal depolymerization in presence of phosphoric acid are determined in this work. Based on the kinetics of the catalyzed or non-catalyzed depolymerization a stepwise pyrolysis procedure is designed by which the formation of ε-caprolactam from polyamide 6 can be separated from the formation of other pyrolysis products. © 2001 Elsevier Science B.V.
Resumo:
Glycidyl methacrylate (GMA) was grafted on ethylene-propylene copolymer during melt processing with peroxide initiation in the presence and absence of a more reactive comonomer (coagent), trimethylolpropane triacrylate (Tris). The characteristics of the grafting systems in terms of the grafting reaction yield and the nature and extent of the competing side reactions were examined. The homopolymers of GMA (Poly-GMA) and Tris (Poly-Tris) and the GMA-Tris copolymer (GMA-co-Tris) were synthesized and characterized. In the absence of the coagent, high levels of poly-GMA, which constituted the major competing reaction, was formed, giving rise to low GMA grafting levels. Further, this grafting system resulted in a high extent of gel formation and polymer crosslinking due to the high levels of peroxide needed to achieve optimum GMA grafting and a consequent large drop in the melt index (increased viscosity) of the polymer. In the presence of the coagent, however, the grafting system required much lower peroxide concentration, by almost an order of magnitude, to achieve the optimum grafting yield. The coagent-containing GMA-grafting system has also resulted in a drastic reduction in the extent of all competing reactions, and in particular, the GMA homopolymerization, leading to improved GMA grafting efficiency with no detectable gel or crosslinking. The mechanisms of the grafting reactions, in the presence and absence of Tris, are proposed.
Resumo:
Background and aims: The selective SGLT2 inhibitor dapagliflozin (DAPA) reduces hyperglycaemia independently of insulin secretion or action by inhibiting renal glucose reabsorption. This study (MB102014) is a randomised double-blind, placebo (PBO)-controlled trial of DAPA added to metformin (MET) in T2DM (n=546) inadequately controlled with MET alone. Previously reported short-term data at week 24 showed significant mean reductions in the primary [HbA1c] and secondary [fasting plasma glucose (FPG) and weight] endpoints with DAPA compared to PBO. Here we report efficacy and safety results at week 102 of the long-term extension. Materials and methods: Patients aged 18-77 years with HbA1c 7-10% received DAPA 2.5 mg, 5 mg, 10 mg or PBO, plus open-label MET (≥1500mg/d). Exploratory endpoints at week 102 included changes from baseline in HbA1c, FPG and weight, and were analyzed by longitudinal repeated measures analysis. Results: Overall 71.2% of patients completed 102 weeks of the study; fewer on PBO (63.5%) than on DAPA 2.5 mg, 5 mg, and 10 mg (68.3%, 73.0%, 79.8%), due mainly to more patients on PBO discontinuing for lack of efficacy. At week 102, all DAPA groups showed greater mean reductions from baseline in HbA1c, FPG and weight compared to PBO (table), effects that were similar to those observed at week 24 and maintained throughout the trial. More patients at week 102 also achieved a therapeutic response of HbA1c<7% with DAPA 2.5 mg, 5 mg, and 10 mg (20.7%, 26.4%, 31.5%) than with PBO (15.4%). Adverse events (AEs), serious AEs and AEs leading to discontinuation were balanced across all groups. Signs and symptoms suggestive of genital infection (GenInf) were reported in 11.7%, 14.6%, 12.6% (DAPA 2.5 mg, 5 mg, 10 mg) and 5.1% (PBO) of patients, with 1 discontinuation due to GenInf. Signs and symptoms suggestive of urinary tract infection (UTI) were reported in 8.0%, 8.8%, 13.3% (DAPA 2.5 mg, 5 mg, 10 mg) and 8.0% (PBO), with 1 discontinuation due to UTI. No event of pyelonephritis was reported. Conclusion: In comparison to PBO, DAPA added to MET over 102 weeks demonstrated greater and sustained improvements in glycaemic control, clinically meaningful reduction in weight, and no increased risk of hypoglycaemia in patients with T2DM inadequately controlled with MET alone.