8 resultados para 4n-removal cross section
em Aston University Research Archive
Resumo:
The object of this thesis is to develop a method for calculating the losses developed in steel conductors of circular cross-section and at temperatures below 100oC, by the direct passage of a sinusoidally alternating current. Three cases are considered. 1. Isolated solid or tubular conductor. 2. Concentric arrangement of tube and solid return conductor. 3. Concentric arrangement of two tubes. These cases find applications in process temperature maintenance of pipelines, resistance heating of bars and design of bus-bars. The problems associated with the non-linearity of steel are examined. Resistance heating of bars and methods of surface heating of pipelines are briefly described. Magnetic-linear solutions based on Maxwell's equations are critically examined and conditions under which various formulae apply investigated. The conditions under which a tube is electrically equivalent to a solid conductor and to a semi-infinite plate are derived. Existing solutions for the calculation of losses in isolated steel conductors of circular cross-section are reviewed, evaluated and compared. Two methods of solution are developed for the three cases considered. The first is based on the magnetic-linear solutions and offers an alternative to the available methods which are not universal. The second solution extends the existing B/H step-function approximation method to small diameter conductors and to tubes in isolation or in a concentric arrangement. A comprehensive experimental investigation is presented for cases 1 and 2 above which confirms the validity of the proposed methods of solution. These are further supported by experimental results reported in the literature. Good agreement is obtained between measured and calculated loss values for surface field strengths beyond the linear part of the d.c. magnetisation characteristic. It is also shown that there is a difference in the electrical behaviour of a small diameter conductor or thin tube under resistance or induction heating conditions.
Resumo:
In this paper, we address this policy issue using a stylised methodology that relies on estimates of the cash flow sensitivity of firms’ investment, as well as a relatively new methodology that enables us to generate a (0, 1) bounded measure of investment efficiency of firms, i.e., the efficiency with which firms can convert their sales into investment, after controlling for unobserved year- and industry-specific effects. Higher investment efficiency is associated with lower financing constraint. Our results indicate that there is considerable heterogeneity in investment efficiency across firms, during a given year; the range being 0.57-0.82. However, the average investment efficiency measure is similar across years, regions and NACE 2-digit industries. We also do not find discernible patterns in the relationship between investment efficiency and firm size, both before and during the financial crisis. The results suggest that while some firms are clearly less efficient at translating their performance into investment, broad policies targeting firms of a certain size, or those within a particular industry or region, may not successfully address the problem of financing constraint in the United Kingdom. The targeting of firms with financing constraints may have to be considerably more refined, and look at not easily observable factors such as credit history/events and organisational capacity of the firms.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
This field work study furthers understanding about expatriate management, in particular, the nature of cross-cultural management in Hong Kong involving Anglo-American expatriate and Chinese host national managers, the important features of adjustment for expatriates living and working there, and the type of training which will assist them to adjust and to work successfully in this Asian environment. Qualitative and quantitative data on each issue was gathered during in-depth interviews in Hong Kong, using structured interview schedules, with 39 expatriate and 31 host national managers drawn from a cross-section of functional areas and organizations. Despite the adoption of Western technology and the influence of Western business practices, micro-level management in Hong Kong retains a cultural specificity which is consistent with the norms and values of Chinese culture. There are differences in how expatriates and host nationals define their social roles, and Hong Kong's recent colonial history appears to influence cross-cultural interpersonal interactions. The inability of the spouse and/or family to adapt to Hong Kong is identified as a major reason for expatriate assignments to fail, though the causes have less to do with living away from family and friends, than with Hong Kong's highly urbanized environment and the heavy demands of work. Culture shock is not identified as a major problem, but in Hong Kong micro-level social factors require greater adjustment than macro-level societal factors. The adjustment of expatriate managers is facilitated by a strong orientation towards career development and hard work, possession of technical/professional expertise, and a willingness to engage in a process of continuous 'active learning' with respect to the host national society and culture. A four-part model of manager training suitable for Hong Kong is derived from the study data. It consists of a pre-departure briefing, post-arrival cross-cultural training, language training in basic Cantonese and in how to communicate more effectively in English with non-native speakers, and the assignment of a mentor to newly arrived expatriate managers.
Resumo:
A cross-sectional study aims to describe the overall picture of a phenomenon, a situational problem, an attitude or an issue, by asking a cross-section of a given population at one specified moment in time. This paper describes the key features of the cross-sectional survey method. It begins by highlighting the main principles of the method, then discusses stages in the research process, drawing on two surveys of primary care pharmacists to illustrate some salient points about planning, sampling frames, definition and conceptual issues, research instrument design and response rates. Four constraints in prescribing studies were noted. First the newness of the subject meant a low basis of existing knowledge to design a questionnaire. Second, there was no public existing database for the sampling frame, so a pragmatic sampling exercise was used. Third, the definition of a Primary Care Pharmacist (PCP) [in full] and respondents recognition of that name and identification with the new role limited the response. Fourth, a growing problem for all surveys, but particularly with pharmacists and general practitioners (GP) [in full] is the growing danger of survey fatigue, which has a negative impact on response levels.
Resumo:
We present data on the development a new type of optical fibre polariser and the characterisation of its wavelength properties. The device is fashioned using a two step process. Firstly, a standard UV long period grating (LPG) with a period of 330μm is inscribed into hydrogenated SMF-28, followed by femtosecond laser ablation of a groove parallel to the fibre axis. The UV inscribed LPGs have inherently low birefringence. However, the removal of the cladding layer parallel to the location of the LPG within the fibre core (as a result the ablation) modifies the cladding modes that couple with the LPG. Furthermore, the groove breaks the fibre symmetry introducing a non-uniform stress profile across the fibre cross section leading to significant birefringence. We show that increasing the depth of the groove increases the birefringence, and this behaviour coupled with the ability to control the wavelength location of the LPGs attenuations peaks results in a polariser able to operate at almost any wavelength and birefringence. The maximum birefringence reported here as polarisation mode splitting was approximately 39±0.1nm with a polarisation loss of 10dB. © 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).