PURPOSE: To validate a new miniaturised, open-field wavefront device which has been developed with the capacity to be attached to an ophthalmic surgical microscope or slit-lamp. SETTING: Solihull Hospital and Aston University, Birmingham, UK DESIGN: Comparative non-interventional study. METHODS: The dynamic range of the Aston Aberrometer was assessed using a calibrated model eye. The validity of the Aston Aberrometer was compared to a conventional desk mounted Shack-Hartmann aberrometer (Topcon KR1W) by measuring the refractive error and higher order aberrations of 75 dilated eyes with both instruments in random order. The Aston Aberrometer measurements were repeated five times to assess intra-session repeatability. Data was converted to vector form for analysis. RESULTS: The Aston Aberrometer had a large dynamic range of at least +21.0 D to -25.0 D. It gave similar measurements to a conventional aberrometer for mean spherical equivalent (mean difference ± 95% confidence interval: 0.02 ± 0.49D; correlation: r=0.995, p<0.001), astigmatic components (J0: 0.02 ± 0.15D; r=0.977, p<0.001; J45: 0.03 ± 0.28; r=0.666, p<0.001) and higher order aberrations RMS (0.02 ± 0.20D; r=0.620, p<0.001). Intraclass correlation coefficient assessments of intra-sessional repeatability for the Aston Aberrometer were excellent (spherical equivalent =1.000, p<0.001; astigmatic components J0 =0.998, p<0.001, J45=0.980, p<0.01; higher order aberrations RMS =0.961, p<0.001). CONCLUSIONS: The Aston Aberrometer gives valid and repeatable measures of refractive error and higher order aberrations over a large range. As it is able to measure continuously, it can provide direct feedback to surgeons during intraocular lens implantations and corneal surgery as to the optical status of the visual system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poster Purpose: A study to validate a prototype Hartmann-Shack (HS) wavefront aberrometer. Methods: The dynamic range was assessed using a calibrated model eye. It was validated against a conventional HS-aberrometer (Topcon KR1W) in 75 eyes using both instruments in random order. Additionally, intra-sessional repeatability was tested. Results: The aberrometer showed a large dynamic range of +21.0 D to −25.0 D. It was comparable to a conventional HS aberrometer for spherical-equivalent SE (MD ± 95% CI: 0.02 ± 0.49D; correlation: r = 0.995, p < 0.001), astigmatic components (J0: 0.02 ± 0.15D; r = 0.977, p < 0.001; J45: 0.03 ± 0.28; r = 0.666, p < 0.001) and HOAs RMS (0.02 ± 0.20D; r = 0.620, p < 0.001). Intra-sessional repeatability correlation was also excellent (SE = 1.000, p < 0.001; astigmatic-components J0 = 0.998, p < 0.001, J45 = 0.980, p < 0.01; HOAs RMS = 0.961, p < 0.001). Conclusions: This study confirms the validity of the prototype aberrometer. The prototype aberrometer can measure continuously to provide direct feedback of the optical status of the eye during surgery.