18 resultados para 390404 Detection and Prevention of Crime

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to design and build an equipment which can detect ferrous and non-ferrous objects in conveyed commodities, discriminate between them and locate the object along the belt and on the width of the belt. The magnetic induction mechanism was used as a means of achieving the objectives of this research. In order to choose the appropriate geometry and size of the induction field source, the field distributions of different source geometries and sizes were studied in detail. From these investigations it was found the square loop geometry is the most appropriate as a field generating source for the purpose of this project. The phenomena of field distribution in the conductors was also investigated. An equipment was designed and built at the preliminary stages of thework based on a flux-gate magnetometer with the ability to detect only ferrous objects.The instrument was designed such that it could be used to detect ferrous objects in the coal conveyors of power stations. The advantages of employing this detector in the power industry over the present ferrous metal electromagnetic separators were also considered. The objectives of this project culminated in the design and construction of a ferrous and non-ferrous detector with the ability to discriminate between ferrous and non-ferrous metals and to locate the objects on the conveying system. An experimental study was carried out to test the performance of the equipment in the detection of ferrous and non-ferrous objects of a given size carried on the conveyor belt. The ability of the equipment to discriminate between the types of metals and to locate the object on the belt was also evaluated experimentally. The benefits which can be gained from the industrial implementations of the equipment were considered. Further topics which may be investigated as an extension of this work are given.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of fixation points (FPs) in visual psychophysics is common practice, though the costs and benefits of different fixation regimens have not been compared. Here we investigate the influence of several different types of FP configurations on the contrast detection of patches of sine-wave gratings. We find that for small targets (1°), the addition of a superimposed central FP can increase thresholds by a factor of 1.3 (2.5 dB) in comparison with no FP, and a factor of 1.5 (3.6 dB) in comparison with FPs that surround the target. These results are consistent with (i) a suppressive influence on the central region of the target from a central FP, and (ii) facilitatory influences from surrounding FPs. Our analysis of the slope of the psychometric function suggests that the facilitatory influence is not due to reduction of uncertainty. Plausible candidate causes for the facilitation are: (i) sensory interactions, (ii) aids to ocular accommodation and convergence, (iii) a reduction in eye-movements and (iv) more accurate placement of the observer’s window of attention. Masking by a central FP is not found for the suprathreshold task of contrast discrimination, suggesting that the masking effects of pedestal and FP do not combine linearly. This means that estimates of the level of masking produced by a contrast pedestal can depend on the details of the fixation point.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Central venous catheters have become an integral part of patient management however they are associated with many complications including infection. Despite efforts being made to reduce the incidence of such infect ions the problem continues to increase and has resource implications for the Health Service. Studies relating to the source of microorganisms causing CVC-associated infection, the cost of such infections and the efficacy of an antimicrobial catheter have been undertaken. Thirty patients who required a CVC as part of their medical management and underwent cardiac surgery had the distal tips of their catheters sampled whilst in situ. Sampling took place within 1 h of catheter placement. Bacteria were isolated from 16% of the catheter distal tips sampled in situ. The guidewires used to insert the devices were also contaminated (50%). When CVC were inserted via a protective sheath, avoiding contact with the skin. the incidence of microbial contamination was reduced. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted onto the distal tip of CVC during the insertion procedure. Needleless intravascular access devices have been introduced in order to reduce the incidence of need1estick injury. However, it was unclear whether such connectors would act as a portal of entry for microorganisms to CVC. The efficacy of these devices was investigated. Within the controlled laboratory environment it was demonstrated that needleless devices, when challenged with microorganisms, did not allow the passage of microbes when flu id was injected. This therefore suggested that the devices should not increase the risk of catheter colonisation. When used in clinical practice however microbial contamination of the needleless connectors was 55 % in comparison to the routinely used luer connectors (23%). The cost of infections associated with CVC was determined. Twenty patients catheterised with a CVC designed for long term use who were admitted to hospital with a presumptive diagnosis of catheter-related infection were studied. The treatment given specifically for this infection was costed. The mean cost of such an infection was £ 1781.81. Throughout the UK this may amount to £1.565.906 per annum. The cost of infections associated with CVC designed for short term use was estimated to be between 5 and 7 million pounds per annum in the UK. In an attempt to reduce both the incidence and cost of catheter- related infection antimicrobial CVC have been developed. The efficacy of a novel polyurethane CVC impregnated on both the internal and external catheter surface with the quaternary ammonium compound benzalkonium chloride was investigated. Eighty eight patients received an antimicrobial catheter and 78 patients a conventional polyurethane CVC. The anti-microbial CVC resulted in a reduction in microbial colonisation of the external and internal polymer surfaces as compared to the control device. The observed reduction in microbial colonisation with the anti-microbial CVC may decrease the likelihood of subsequent infection offering a useful approach to the prevention of catheter-related infections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A scintillation proximity assay (SPA) has been used successfully to detect and quantify, in real-time, the kinetic progress of hydrolysis of [ H]acetate esters from scintillant-containing styrenic and poly(ethylene glycol) (PEG)-based polymer supports in both organic and aqueous media.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The prevalence rates of type2 diabetes mellitus (T2DM) continues to rise among British Pakistanis. The aim of this project was to explore T2DM perceptions and any preventative intentions among British Pakistani women and to discover whether they are doing anything to prevent the onset in themselves and their families. Initially a systematic review was conducted to investigate 20 existing prevention interventions and to assess their effectiveness (n=12,419). Mixed methods approach was adopted and three studies were conducted. The first study consisted of two focus groups with T2DM mothers (n=8) and three focus groups with non-T2DM mothers (n=17). The second study consisted of four focus groups young British Pakistani females (n=11). All focus groups were transcribed verbatim and analysed using thematic analysis. Following these a quantitative study was undertaken comprising of a questionnaire survey; 12 prevention-perception items (derived from the qualitative data) and the Illness-Perception Questionnaire Revised (IPQ-R) using participants from the same populations: T2DM mothers (n=41), non-T2DM mother (n=47) and young women (n=42). Results were analysed using multiple/hierarchical regression. The systematic review highlighted that the most effective prevention programmes focussed on behaviour and lifestyle with a combination of support and education to participants. The research studies demonstrated that T2DM was seen as an older person’s disease to be dealt with if/when it happens. T2DM mothers demonstrated knowledge and prevention understanding. There were non-significant relationships between prevention perceptions and T2DM illness perceptions across all three groups. The finding of this thesis emphasised that lifestyle interventions are crucial to aiding T2DM preventions as a good healthy diet and regular physical activity are the key components to T2DM prevention, and the importance of personal experience in perceived severity and lay-beliefs regarding T2DM and on family/cultural influences in British-Pakistanis. The findings of this project can be used to design culturally specific interventions towards preventing T2DM in the British Pakistani community.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oxidised biomolecules in aged tissue could potentially be used as biomarkers for age-related diseases; however, it is still unclear whether they causatively contribute to ageing or are consequences of the ageing process. To assess the potential of using protein oxidation as markers of ageing, mass spectrometry (MS) was employed for the identification and quantification of oxidative modifications in obese (ob/ob) mice. Lean muscle mass and strength is reduced in obesity, representing a sarcopenic model in which the levels of oxidation can be evaluated for different muscular systems including calcium homeostasis, metabolism and contractility. Several oxidised residues were identified by tandem MS (MS/MS) in both muscle homogenate and isolated sarcoplasmic reticulum (SR), an organelle that regulates intracellular calcium levels in muscle. These modifications include oxidation of methionine, cysteine, tyrosine, and tryptophan in several proteins such as sarcoplasmic reticulum calcium ATPase (SERCA), glycogen phosphorylase, and myosin. Once modifications had been identified, multiple reaction monitoring MS (MRM) was used to quantify the percentage modification of oxidised residues within the samples. Preliminary data suggests proteins in ob/ob mice are more oxidised than the controls. For example SERCA, which constitutes 60-70% of the SR, had approximately a 2-fold increase in cysteine trioxidation of Cys561 in the obese model when compared to the control. Other obese muscle proteins have also shown a similar increase in oxidation for various residues. Further analysis with complex protein mixtures will determine the potential diagnostic use of MRM experiments for analysing protein oxidation in small biological samples such as muscle needle biopsies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Holistic face perception, i.e. the mandatory integration of featural information across the face, hasbeen considered to play a key role when recognizing emotional face expressions (e.g., Tanaka et al.,2002). However, despite their early onset holistic processing skills continue to improvethroughout adolescence (e.g., Schwarzer et al., 2010) and therefore might modulate theevaluation of facial expressions. We tested this hypothesis using an attentional blink (AB)paradigm to compare the impact of happy, fearful and neutral faces in adolescents (10–13 years)and adults on subsequently presented neutral target stimuli (animals, plants and objects) in a rapidserial visual presentation stream. Adolescents and adults were found to be equally reliable whenreporting the emotional expression of the face stimuli. However, the detection of emotional butnot neutral faces imposed a significantly stronger AB effect on the detection of the neutral targetsin adults compared to adolescents. In a control experiment we confirmed that adolescents ratedemotional faces lower in terms of valence and arousal than adults. The results suggest a protracteddevelopment of the ability to evaluate facial expressions that might be attributed to the latematuration of holistic processing skills.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surgical site infections (SSI) are a prevalent health care-associated infection (HAl). Prior to the mid-19th century, surgical sites commonly developed postoperative wound complications. It was in the 1860's, after Joseph Lister introduced carbolic acid and the principles of antisepsis that postoperative wound infection significantly decreased. Today, patient preoperative skin preparation with an antiseptic agent prior to surgery is a standard of practice. Povidone-iodine and chlorhexidine gluconate are currently the most commonly used antimicrobial agents used to prep the patient's skin. In this current study, the epidemiology, diagnosis, surveillance and prevention of SSI with chlorhexidine were investigated. The antimicrobial activity of chlorhexidine was assessed. In in-vitro and in-vivo studies the antimicrobial efficacy of 2% (w/v) chlorhexidine gluconate (CHG) in 70% isopropyl alcohol (IPA) and 10% povidoneiodine (PVP-I) in the presence of 0.9% normal saline or blood were examined. The 2% CHG in 70% IPA solutions antimicrobial activity was not diminished in the presence of 0.9% normal saline or blood. In comparison, the traditional patient preoperative skin preparation, 10% PVP-I antimicrobial activity was not diminished in the presence of 0.9% normal saline, but was diminished in the presence of blood. In an in-vivo human volunteer study the potential for reduction of the antimicrobial efficacy of aqueous patient preoperative skin preparations compromised by mechanical removal of wet product from the application site (blot) was assessed. In this evaluation, 2% CHG and 10% povidone-iodine (PVP-I) were blotted from the patient's skin after application to the test site. The blotting, or mechanical removal, of the wet antiseptic from the application site did not produce a significant difference in product efficacy. In a clinical trial to compare 2% CHG in 70% IPA and PVP-! scrub and paint patient preoperative skin preparation for the prevention of SSI, there were 849 patients randomly assigned to the study groups (409 in the chlorhexidine-alcohol and 440 in the povidone-iodine group) in the intention-to-treat analysis. The overall surgical site infection was significantly lower in the 2% CHG in 70% IPA group than in the PVP-I group (9.5% versus 16.1 %, p=0.004; relative risk, 0.59 with 95% confidence interval of 0.41 to 0.85). Preoperative cleansing of the patient's skin with chlorhexidine-alcohol is superior to povidone-iodine in preventing surgical site infection after clean-contaminated surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The potential source of CVC colonisation was assessed. Isolates of coagulase-negative staphylococci (CoNS) recovered from the skin and CVC components of 3 cardiothoracic surgery patients were characterised by pulsed-field gel electrophoresis (PFGE). The genetic heterogeneity of CoNS isolated from the skin was demonstrated and specific genotypes implicated in catheter colonisation. In addition, phenotypic and genotypic typing techniques were assessed for their ability to characterise strains of CoNS recovered from 33 patients who developed catheter-related bloodstream infection (CR-BSI) on a bone marrow transplant (BMT) unit and Siaphylococcus aureus recovered from 6 cardiothoracic surgery patients with surgical site infection (SSI) following median sternotomy. This epidemiological investigation revealed that common strains of CoNS and 51 aureus where not associated with infection in patients with CR-BSI or sternal SSI during the study period. Furthermore, there was no correlation between phenotypic and genotypic characterisation results. The variable expression of phenotypic traits within strains of staphylococci was evident whilst PFGE and randomly amplified polymorphic DNA (RAPD) were highly discriminatory for the molecular characterisation of S. aureus and CoNS. This was highlighted in 8 stem cell transplant (SCT) patients whereby it was demonstrated that routine identification and characterisation of CoNS by phenotypic techniques may not be adequate for the diagnosis of CR-BSI by current guidelines. The potential of the lipid S ELISA to facilitate the diagnosis of CR-BSI in 38 haematology/SCT patients and sternal SSI in 57 cardiothoracic surgery patients was also assessed. The ELISA proved to be a sensitive test for the rapid serodiagnosis of infection due to staphylococci in immunocompetent patients. The acridine orange leucocyte cytospin test (AOLC) was also evaluated for the rapid diagnosis of CR-BSI in 16 haematology/SCT patients with Hickman CVC in situ. Although the sensitivity of the test was low, it may provide a useful adjunct to conventional methods for the in situ sampling of catheters to predict and diagnose CR-BSI, preventing the unnecessary removal of CVC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Initially the study focussed on the factors affecting the ability of the police to solve crimes. An analysts of over twenty thousand police deployments revealed the proportion of time spent investigating crime contrasted to its perceived importance and the time spent on other activities. The fictional portrayal of skills believed important in successful crime investigation were identified and compared to the professional training and 'taught skills’ given to police and detectives. Police practitioners and middle management provided views on the skills needed to solve crimes. The relative importance of the forensic science role. fingerprint examination and interrogation skills were contrasted with changes in police methods resulting from the Police and Criminal Evidence Act and its effect on confessions. The study revealed that existing police systems for investigating crime excluding specifically cases of murder and other serious offences, were unsystematic, uncoordinated, unsupervised and unproductive in using police resources. The study examined relevant and contemporary research in the United States and United Kingdom and with organisational support introduced an experimental system of data capture and initial investigation with features of case screening and management. Preliminary results indicated increases in the collection of essential information and more effective use of investigative resources. In the managerial framework within which this study has been conducted, research has been undertaken in the knowledge elicitation area as a basis for an expert system of crime investigation and the potential organisational benefits of utilising the Lap computer in the first stages of data gathering and investigation. The conclusions demonstrate the need for a totally integrated system of criminal investigation with emphasis on an organisational rather than individual response. In some areas the evidence produced is sufficient to warrant replication, in others additional research is needed to further explore other concepts and proposed systems pioneered by this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sodium formate, potassium acetate and a mixture of calcium and magnesium acetate (CMA) have all been identified as effective de-icing agents. In this project an attempt has been made to elucidate potentially deleterious effects of these substances on the durability of reinforced concrete. Aspects involving the corrosion behaviour of embedded steel along with the chemical and physical degradation of the cementitious matrix were studied. Ionic diffusion characteristics of deicer/pore solution systems in hardened cement paste were also studied since rates of ingress of deleterious agents into cement paste are commonly diffusion-controlled. It was found that all the compounds tested were generally non-corrosive to embedded steel, however, in a small number of cases potassium acetate did cause corrosion. Potassium acetate was also found to cause cracking in concrete and cement paste samples. CMA appeared to degrade hydrated cement paste although this was apparently less of a problem when commercial grade CMA was used in place of the reagent grade chemical. This was thought to be due to the insoluble material present in the commercial formulation forming a physical barrier between the concrete and the de-icing solution. With the test regimes used sodium formate was not seen to have any deleterious effect on the integrity of reinforced concrete. As a means of restoring the corrosion protective character of chloride-contaminated concrete the process of electrochemical chloride removal has been previously developed. Potential side-effects of this method and the effect of external electrolyte composition on chloride removal efficiency were investigated. It was seen that the composition of the external electrolyte has a significant effect on the amount of chloride removed. It was also found that, due to alterations to the composition of the C3A hydration reaction products, it was possible to remove bound chloride as well as that in the pore solution. The use of an external electrolyte containing lithium ions was also tried as a means of preventing cathodically-induced alkali-silica reaction in concretes containing potentially reactive aggregates. The results obtained were inconclusive and further practical development of this approach is needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a novel device for the characterisation of static magnetic fields through monitoring wavelength shifts of femtosecond inscribed fibre Bragg grating and micromachined slot, coated with Terfenol-D. The device was sensitive to static magnetic fields and can be used as a vectoral sensor for the detection of magnetic fields as low as 0.046 mT with a resolution of ± 0.3mT in transmission and ± 0.7mT in reflection. The use of a femtosecond laser to both inscribe the FBGs and micromachine the slot in a single stage prior to coating the device significantly simplifies the fabrication.