10 resultados para 1995_12201025 Optics-21

em Aston University Research Archive


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ophthalmophakometric measurements of ocular surface radius of curvature and alignment were evaluated on physical model eyes encompassing a wide range of human ocular dimensions. The results indicated that defocus errors arising from imperfections in the ophthalmophakometer camera telecentricity and light source collimation were smaller than experimental errors. Reasonable estimates emerged for anterior lens surface radius of curvature (accuracy: 0.02–0.10 mm; precision 0.05–0.09 mm), posterior lens surface radius of curvature (accuracy: 0.10–0.55 mm; precision 0.06–0.20 mm), eye rotation (accuracy: 0.00–0.32°; precision 0.06–0.25°), lens tilt (accuracy: 0.00–0.33°; precision 0.05–0.98°) and lens decentration (accuracy: 0.00–0.07 mm; precision 0.00–0.07 mm).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A clinical evaluation of the Shin-Nippon SRW-5000 (Japan), a newly released commercial autorefractor, was undertaken to assess its repeatability and validity compared to subjective refraction. Measurements of refractive error were performed on 200 eyes of 100 subjects (aged 24.4±8.0 years) subjectively (non-cycloplegic) by one optometrist and objectively with the SRW-5000 autorefractor by a second. Repeatability was assessed by examining the differences between the seven autorefractor readings taken from each eye and by re-measuring the objective prescription of 50 eyes at a subsequent session. Although the SRW-5000 read slightly more plus than subjective refraction (mean spherical equivalent +0.16±0.44D), it was found to be highly valid (accurate) compared to subjective refraction and repeatable over the prescription range of +6.50 to -15.00D examined. The Shin-Nippon SRW-5000 autorefractor is therefore a valuable complement to subjective refraction and as it offers the advantage of a binocular open field-of-view, has a great potential benefit for accommodation research studies. Copyright © 2001 The College of Optometrists.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We propose a simple Er-doped fiber laser configuration for achieving stable dual-wavelength oscillation at room temperature, in which a high birefringence fiber Bragg grating was used as the wavelength-selective component. Stable dual-wavelength oscillation at room temperature with a wavelength spacing of 0.23 nm and mutually orthogonal polarization stages was achieved by utilizing the polarization hole-burning effect. An amplitude variation of less than 0.7 dB over an 80 s period was obtained for both wavelengths.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A newly released commercial autorefractor, the Shin-Nippon SRW-5000 (Japan), has been found to be valid compared to subjective refraction and repeatable over a wide prescription range. Its binocular open field-of-view allows the accommodative state to be monitored while a natural environment is viewed. In conventional static mode, the device can take up to 45 readings in 1min using digital image analysis of the reflected retinal image of a measurement ring. Continuous on-line analysis of the ring provides high (up to 60Hz) temporal resolution of the refractive state to an accuracy of <0.001D. Pupil size can also be analysed to a resolution of <0.001mm. The measurement of accommodation and pupil size was relatively unaffected by eccentricity of viewing up to ±10° and instrument focusing inaccuracies of ±5mm. The resolution properties of the analysis are shown to be ideal for measurement of dynamic accommodation and pupil responses. Copyright © 2001 The College of Optometrists.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Systemic hypertension is an important public health concern. If optometrists are to perform a more active role in the detection and monitoring of high blood pressure (BP), there is a need to improve the consistency of describing the retinal vasculature and to assess patient's ability to correctly report the diagnosis of hypertension, its control and medication. One hundred and one patients aged >40 years were dilated and had fundus photography performed. BP was measured and a self-reported history of general health and current medication was compared with the records of their general practitioner (GP). The status of the retinal vasculature was quantified using a numeric scale by five clinicians and this was compared to the same evaluation performed with the aid of a basic pictorial grading scale. Image analysis was used to objectively measure the artery-to-vein (A/V) ratio and arterial reflex. Arteriolar tortuosity and calibre changes were found to be the most sensitive retinal signs of high BP. Using the grading scale to describe the retinal vasculature significantly improved inter- and intra-observer repeatability. Almost half the patients examined were on medication for high BP or cardiovascular disease. Patients' ability to give their complete medical history was poor, as was their ability to recall what medication they had been prescribed. GPs indicated it was useful to receive details of their patient's BP when it was >140/90 mmHg. The use of improved description of the retinal vasculature and stronger links between optometrists and GPs may enhance future patient care. © 2001 The College of Optometrists. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cardiovascular disease and stroke continue to be the chief causes of death in developed countries and one of the leading causes of visual impairment. The individual with systemic hypertension may remain asymptomatic for many years. Systemic mortality and morbidity are markedly higher for hypertensives than normotensives, but can be significantly reduced by early diagnosis and then efficient management. However, the ability of Optometrists to detect and appropriately refer systemic hypertensives remains generally poor. This review examines the disease, its effects and detection by observation of the retinal signs, particularly those considered to be pre-malignant. Previous methods of classifying retinal hypertensive signs are discussed along with more recent image analysis techniques. The role of the optometrist in detecting, monitoring and appropriate referral of systemic hypertensives is discussed in relation to current research. (C) 2001 The College of Optometrists. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Urinary bladder diseases are a common problem throughout the world and often difficult to accurately diagnose. Furthermore, they pose a heavy financial burden on health services. Urinary bladder tissue from male pigs was spectrophotometrically measured and the resulting data used to calculate the absorption, transmission, and reflectance parameters, along with the derived coefficients of scattering and absorption. These were employed to create a "generic" computational bladder model based on optical properties, simulating the propagation of photons through the tissue at different wavelengths. Using the Monte-Carlo method and fluorescence spectra of UV and blue excited wavelength, diagnostically important biomarkers were modeled. Additionally, the multifunctional noninvasive diagnostics system "LAKK-M" was used to gather fluorescence data to further provide essential comparisons. The ultimate goal of the study was to successfully simulate the effects of varying excited radiation wavelengths on bladder tissue to determine the effectiveness of photonics diagnostic devices. With increased accuracy, this model could be used to reliably aid in differentiating healthy and pathological tissues within the bladder and potentially other hollow organs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present recent results on femtosecond microfabrication of key components for integrated optics such as highly curved low-loss waveguides in glasses, depressed cladding waveguides in crystals. Details of microfabrication and characterisation are discussed.