3 resultados para 15d-PGJ2
em Aston University Research Archive
Resumo:
Oxidative stress has been implicated in the pathogenesis of many neurodegenerative diseases including Alzheimer’s disease. The transcription factor, Nrf2 (nuclear factor E2-related factor 2) that binds to the antioxidant responsive element (ARE) activates a battery of genes encoding enzymes and factors essential for neuronal survival. We have investigated the hypothesis that a downstream product of cyclooxygenase(COX-2), 15-deoxy-delta (12, 14)-prostagland in J2 (15d-PGJ2) has protective effects by activating the Nrf2 pathway during oxidative stress.Human neuroblastoma cells (SHSY5Y) were differentiated intoneuronal-like cells as described previously (Gimenez-Cassina et al.,2006). SHSY5Y cells were co-treated with 10 mM buthionine sulfoximine (BSO) 7 10 mM 15d-PGJ2. Cell viability was measured by MTT assay and cellular glutathione (GSH) levels were measured after treating cells for0.5-24 hours by GSH recycling assay. Cellular Nrf2 levels were determined by immunoblotting. IL-6 levels were measured by ELISA.15d-PGJ2 alone lowered GSH levels 30min after the treatment(12.870.64 nmol/mg protein) and returned to untreated control levels at 16hours (28.173.6 nmol/mg protein; Po0.01). Compared to intracellular GSH levels in untreated cells (27.871.8 nmol/mg protein) BSO treatment alone significantly decreased GSH (9.672.1 nmol/mg protein;Po0.001) but co-incubation with 15d-PGJ2 for 24 hours prevented the depletion elicited by BSO(21.372.7 nmol/mg protein). Compared to untreated cells BSO treatment decrease dIL-6 secretion (from 0.941.6ng/ml to 0.6971.3ng/ml) and total Nrf2 protein levels (by21%). Co-incubation with15d-PGJ2 for 24 hours with BSO did not change IL-6(0.6771.4ng/ml) or total Nrf2 level at any time point. This study suggests that neuronal toxicity resulting from glutathione depletion canbere stored by the induction of Nrf2-ARE pathway and the role of the Nrf2 signalling merits further investigation in neurodegenerative diseases.
Resumo:
PURPOSE: To validate a new miniaturised, open-field wavefront device which has been developed with the capacity to be attached to an ophthalmic surgical microscope or slit-lamp. SETTING: Solihull Hospital and Aston University, Birmingham, UK DESIGN: Comparative non-interventional study. METHODS: The dynamic range of the Aston Aberrometer was assessed using a calibrated model eye. The validity of the Aston Aberrometer was compared to a conventional desk mounted Shack-Hartmann aberrometer (Topcon KR1W) by measuring the refractive error and higher order aberrations of 75 dilated eyes with both instruments in random order. The Aston Aberrometer measurements were repeated five times to assess intra-session repeatability. Data was converted to vector form for analysis. RESULTS: The Aston Aberrometer had a large dynamic range of at least +21.0 D to -25.0 D. It gave similar measurements to a conventional aberrometer for mean spherical equivalent (mean difference ± 95% confidence interval: 0.02 ± 0.49D; correlation: r=0.995, p<0.001), astigmatic components (J0: 0.02 ± 0.15D; r=0.977, p<0.001; J45: 0.03 ± 0.28; r=0.666, p<0.001) and higher order aberrations RMS (0.02 ± 0.20D; r=0.620, p<0.001). Intraclass correlation coefficient assessments of intra-sessional repeatability for the Aston Aberrometer were excellent (spherical equivalent =1.000, p<0.001; astigmatic components J0 =0.998, p<0.001, J45=0.980, p<0.01; higher order aberrations RMS =0.961, p<0.001). CONCLUSIONS: The Aston Aberrometer gives valid and repeatable measures of refractive error and higher order aberrations over a large range. As it is able to measure continuously, it can provide direct feedback to surgeons during intraocular lens implantations and corneal surgery as to the optical status of the visual system.
Resumo:
Poster Purpose: A study to validate a prototype Hartmann-Shack (HS) wavefront aberrometer. Methods: The dynamic range was assessed using a calibrated model eye. It was validated against a conventional HS-aberrometer (Topcon KR1W) in 75 eyes using both instruments in random order. Additionally, intra-sessional repeatability was tested. Results: The aberrometer showed a large dynamic range of +21.0 D to −25.0 D. It was comparable to a conventional HS aberrometer for spherical-equivalent SE (MD ± 95% CI: 0.02 ± 0.49D; correlation: r = 0.995, p < 0.001), astigmatic components (J0: 0.02 ± 0.15D; r = 0.977, p < 0.001; J45: 0.03 ± 0.28; r = 0.666, p < 0.001) and HOAs RMS (0.02 ± 0.20D; r = 0.620, p < 0.001). Intra-sessional repeatability correlation was also excellent (SE = 1.000, p < 0.001; astigmatic-components J0 = 0.998, p < 0.001, J45 = 0.980, p < 0.01; HOAs RMS = 0.961, p < 0.001). Conclusions: This study confirms the validity of the prototype aberrometer. The prototype aberrometer can measure continuously to provide direct feedback of the optical status of the eye during surgery.