57 resultados para 111300 OPTOMETRY AND OPHTHALMOLOGY

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This chapter deals with the physicochemical aspects of structure-property relationships in synthetic hydrogels, with particular reference to their application in optometry and ophthalmology. It demonstrates the ways in which the amount of water contained in the hydrogel network can be manipulated by changes in copolymer composition and illustrates the advantages and limitations imposed by use of water as a means of influencing surface, transport and mechanical properties of the gel. The chapter then illustrates how this basic understanding has formed a platform for the development of synthetic interpenetrating networks and macroporous materials, and of hybrids of natural and synthetic hydrogels. The behaviour of these more complex systems is not so centrally dominated by the equilibrium water content as is the case with homogeneous synthetic hydrogels, thus providing advantageous ways of extending the properties and applications of these interesting materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. High myopia in childhood is associated with important ocular and systemic conditions. However in the UK, high myopia in early childhood is not specifically identified in current ophthalmology, optometry, or orthoptic protocols for screening, referral, or investigation. An ongoing study in the West Midlands, UK, is investigating high myopia presenting to community health care clinics with the aim of compiling guidelines for assessment and subsequent referral. Methods. Children with high myopia were identified from community optometric and orthoptic sources and invited for an ophthalmology and optometry examination to ascertain possible ocular or systemic disease. Results. High myopia with no associated ocular or systemic condition was present in 15 (56%) of the children. In seven children (25%), associated ocular problems were found including unrecognized retinal dystrophies and amblyopia. Systemic disorders associated with high myopia were found in five children (19%) and included Sticklers syndrome, Weill-Marchesani syndrome, and homocystinuria. In one child, the diagnosis made before this study was found to be incorrect, and in another child, the results were inconclusive. In two cases, the diagnosis of a systemic condition in the child led to the identification of the disease in at least one relative. Conclusions. There is a high prevalence of ocular and systemic abnormality in young children seen in the community. Optometric and ophthalmologic assessment of children less than 10 years with myopia ≥5 D is likely to identify significant ocular or systemic disease, a proportion of which will respond to medical intervention. Detection and prompt referral of these cases by community health care services may be expected to prolong vision and possibly life expectancy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A number of neurodegenerative diseases caused by prions have been described recently. These include Creutzfeldt-Jakob disease (CJD) in humans, scrapie in sheep and BSE in cows. Patients with CJD may suffer a range of visual problems including eye movement deficits and visual hallucinations. In addition, it is possible that CJD may be acquired via corneal transplant and that prions may be transmitted by reusable contact lenses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alzheimer's disease is the commonest degenerative disease of the nervous system to affect elderly people. It is characterised by 'dementia', a global cognitive decline involving loss of short term memory, judgement and emotional control. In addition, patients may suffer a range of visual problems including impairment of visual acuity, colour vision, eye movement problems and complex visual disturbances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To investigate objectively and noninvasively the role of cognitive demand on autonomic control of systemic cardiovascular and ocular accommodative responses in emmetropes and myopes of late-onset. METHODS. Sixteen subjects (10 men, 6 women) aged between 18 and 34 years (mean ± SD: 22.6 ± 4.4 years), eight emmetropes (EMMs; mean spherical equivalent [MSE] refractive error ± SD: 0.05 ± 0.24 D) and eight with late-onset myopia (LOMs; MSE ± SD: -3.66 ± 2.31 D) participated in the study. Subjects viewed stationary numerical digits monocularly within a Badal optical system (at both 0.0 and -3.0 D) while performing a two-alternative, forced-choice paradigm that matched cognitive loading across subjects. Five individually matched cognitive levels of increasing difficulty were used in random order for each subject. Five 20-second, continuous-objective recordings of the accommodative response measured with an open-view infrared autorefractor were obtained for each cognitive level, whereas simultaneous measurement of heart rate was continuously recorded with a finger-mounted piezoelectric pulse transducer for 5 minutes. Fast Fourier transformation of cardiovascular function allowed the relative power of the autonomic components to be assessed in the frequency domain, whereas heart period gave an indication of the time-domain response. RESULTS. Increasing the cognitive demand led to a significant reduction in the accommodative response in all subjects (0.0 D: by -0.35 ± 0.33 D; -3.0 D: by -0.31 ± 0.40 D, P < 0.001). The greater lag of LOMs compared with EMMs was not significant (P = 0.07) at both distance (0.38 ± 0.35 D) and near (0.14 ± 0.42 D). Mean heart period reduced with increasing levels of workload (P < 0.0005). LOMs exhibited a relative elevation in sympathetic system activity compared to EMMs. Within refractive groups, however, accommodative shifts with increasing cognition correlated with parasympathetic activity (r = 0.99, P < 0.001), more than with sympathetic activity (r = 0.62, P > 0.05). CONCLUSIONS. In an equivalent workload paradigm, increasing cognitive demand caused a reduction in accommodative response that was attributable principally to a concurrent reduction in the relative power of the parasympathetic component of the autonomic nervous system (ANS). The disparity in accommodative response between EMMs and LOMs, however, appears to be augmented by changes in the sympathetic nervous component of the systemic ANS. Copyright © Association for Research in Vision and Ophthalmology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. The prevalence of myopia is known to vary with age, ethnicity, level of education, and socioeconomic status, with a high prevalence reported in university students and in people from East Asian countries. This study determines the prevalence of ametropia in a mixed ethnicity U.K. university student population and compares associated ocular biometric measures. Methods. Refractive error and related ocular component data were collected on 373 first-year U.K. undergraduate students (mean age = 19.55 years ± 2.99, range = 17-30 years) at the start of the academic year at Aston University, Birmingham, and the University of Bradford, West Yorkshire. The ethnic variation of the students was as follows: white 38.9%, British Asian 58.2%, Chinese 2.1%, and black 0.8%. Noncycloplegic refractive error was measured with an infrared open-field autorefractor, the Shin-Nippon NVision-K 5001 (Shin Nippon, Ryusyo Industrial Co. Ltd, Osaka, Japan). Myopia was defined as a mean spherical equivalent (MSE) less than or equal to -0.50 D. Hyperopia was defined as an MSE greater than or equal to +0.50 D. Axial length, corneal curvature, and anterior chamber depth were measured using the Zeiss IOLMaster (Carl Zeiss, Jena, GmBH). Results. The analysis was carried out only for white and British Asian groups. The overall distribution of refractive error exhibited leptokurtosis, and prevalence levels were similar for white and British Asian (the predominant ethnic group) students across each ametropic group: myopia (50% vs. 53.4%), hyperopia (18.8% vs. 17.3%), and emmetropia (31.2% vs. 29.3%). There were no significant differences in the distribution of ametropia and biometric components between white and British Asian samples. Conclusion. The absence of a significant difference in refractive error and ocular components between white and British Asian students exposed to the same educational system is of interest. However, it is clear that a further study incorporating formal epidemiologic methods of analysis is required to address adequately the recent proposal that juvenile myopia develops principally from myopiagenic environments and is relatively independent of ethnicity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the correlation between tests of visual function and perceived visual ability recorded with a 'quality-of-life' questionnaire for patients with central field loss. Method: 12 females and 7 males (mean age = 53.1 years; Range = 23 - 80 years) with subfoveal neovascular membranes underwent a comprehensive assessment of visual function. Tests included unaided distance vision, high and low contrast distance logMAR visual acuity (VA), Pelli-Robson contrast senstivity (at 1m), near logMAR word VA and text reading speed. All tests were done both monocularly and binocularly. The patients also completed a 28 point questionnaire separated into a 'core' section consisting of general questions about perceived visual function and a 'module' section with specific questions on reading function. Results: Step-wise multiple regression analysis was used to determine which visual function tests were correlated with the patients's perceived visual function and to rank them in order of importance. The visual function test that explains most of the variance in both 'core' score (66%0 and the 'module' score (68%) of the questionnaire is low contrast VA in the better eye (P<0.001 in both cases). Further, the module score also accounts for a significant proportion of the variance (P<0.01) of the distance logMAR VA in both the better and worse eye, and the near logMAR in both the better eye and binocularly. Conclusions: The best predictor of both perceived reading ability and of general perceived visual ability in this study is low contrast logMAR VA. The results highlight that distance VA is not the only relevant measure of visual fucntion in relation to a patients's perceived visual performance and should not be considered a determinant of surgical or management success.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Variant Creutzfeldt-Jakob disease (vCJD) was first described in the UK in 1996 and is one of a group of diseases, the transmissible spongiform encephalopathies (TSEs) which affect both animals and humans. This review discusses vCJD in the context of other TSEs, considers the controversial 'prion' hypothesis as to the cause of the disease, the ocular features of vCJD, and the possible transmission of the disease via optoetric devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To compare axial length growth between white children with myopia wearing orthokeratology contact lenses (OK) and distance single-vision spectacles (SV) over a 2-year period. METHODS. Subjects 6 to 12 years of age with myopia -0.75 to -4.00 diopters of sphere (DS) and astigmatism ≤1.00 diopters of cylinder (DC) were prospectively allocated OK or SV correction. Measurements of axial length (Zeiss IOLMaster), corneal topography, and cycloplegic refraction were taken at 6-month intervals. RESULTS. Thirty-one children were fitted with OK and 30 with SV. Following 24 months, axial length increased significantly over time for both the OK group (0.47 mm) and SV group (0.69 mm; P < 0.001), with a significant interaction between time and group (P = 0.05) reflecting a greater increase in the SV group. Significant differences in refraction were found over time, between groups and for the interaction between time and group for spherical (all P < 0.001) but not cylindrical components of refraction (all P > 0.05). Significantly greater corneal flattening was evident in the OK group for the flatter and steeper corneal powers and for corneal shape factor (all P ≤0.05). CONCLUSIONS. Orthokeratology contact lens wear reduces axial elongation in comparison to distance single-vision spectacles in children. © 2012 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To evaluate the influence of soft contact lens midperipheral shape profile and edge design on the apparent epithelial thickness and indentation of the ocular surface with lens movement. Methods. Four soft contact lens designs comprising of two different plano midperipheral shape profiles and two edge designs (chiseled and knife edge) of silicone-hydrogel material were examined in 26 subjects aged 24.7 ± 4.6 years, each worn bilaterally in randomized order. Lens movement was imaged enface on insertion, at 2 and 4 hours with a high-speed, high-resolution camera simultaneous to the cross-section of the edge of the contact lens interaction with the ocular surface captured using optical coherence tomography (OCT) nasally, temporally, and inferiorly. Optical imaging distortions were individually corrected for by imaging the apparent distortion of a glass slide surface by the removed lens. Results. Apparent epithelial thickness varied with edge position (P < 0.001). When distortion was corrected for, epithelial indentation decreased with time after insertion (P = 0.010), changed after a blink (P < 0.001), and varied with position on the lens edge (P < 0.001), with the latter being affected by midperipheral lens shape profile and edge design. Horizontal and vertical lens movement did not change with time postinsertion. Vertical motion was affected by midperipheral lens shape profile (P < 0.001) and edge design (P < 0.001). Lens movement was associated with physiologic epithelium thickness for lens midperipheral shape profile and edge designs. Conclusions. Dynamic OCT coupled with high-resolution video demonstrated that soft contact lens movement and image-corrected ocular surface indentation were influenced by both lens edge design and midperipheral lens shape profiles. © 2013 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate eyelid temperature change and short-term effects on tear film stability and lipid layer thickness in healthy patients using a commercially available warm compress (MGDRx EyeBag) for ophthalmic use. Methods: Eyelid temperature, noninvasive tear film breakup time (NITBUT), and tear film lipid layer thickness (TFLLT) of 22 healthy subjects were measured at baseline, immediately after, and 10 minutes after application of a heated eyebag for 5 minutes to one eye selected at random. A nonheated eyebag was applied to the contralateral eye as a control. Results: Eyelid temperatures, NITBUT, and TFLLT increased significantly from baseline in test eyes immediately after removal of the heated eyebag compared with those in control eyes (maximum temperature change, 2.3 +/- 1.2[degrees]C vs. 0.3 +/- 0.5[degrees]C, F = 20.533, p < 0.001; NITBUT change, 4.0 +/- 2.3 seconds vs. 0.4 +/- 1.7 seconds, p < 0.001; TFLLT change, 2.0 +/- 0.9 grades vs. 0.1 +/- 0.4 grades, Z = -4.035, p < 0.001). After 10 minutes, measurements remained significantly higher than those in controls (maximum temperature change, 1.0 +/- 0.7[degrees]C vs. 0.1 +/- 0.3[degrees]C, F = 14.247, p < 0.001; NITBUT change, 3.6 +/- 2.1 seconds vs. 0.1 +/- 1.9 seconds, p < 0.001; TFLLT change, 1.5 +/- 0.9 vs. 0.2 +/- 0.5 grades, Z = -3.835, p < 0.001). No adverse events occurred during the study. Conclusions: The MGDRx EyeBag is a simple device for heating the eyelids, resulting in increased NITBUT and TFLLT in subjects without meibomian gland dysfunction that seem to be clinically significant. Future studies are required to determine clinical efficacy and evaluate safety after long-term therapy in meibomian gland dysfunction patients. © 2013 American Academy of Optometry

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To assess the relative clinical success of orthokeratology contact lenses (OK) and distance single-vision spectacles (SV) in children in terms of incidences of adverse events and discontinuations over a 2-year period. Methods. Sixty-one subjects 6 to 12 years of age with myopia of - 0.75 to - 4.00DS and astigmatism =1.00DC were prospectively allocated OK or SV correction. Subjects were followed at 6-month intervals and advised to report to the clinic immediately should adverse events occur. Adverse events were categorized into serious, significant, and non-significant. Discontinuation was defined as cessation of lens wear for the remainder of the study. Results. Thirty-one children were corrected with OK and 30 with SV. A higher incidence of adverse events was found with OK compared with SV (p < 0.001). Nine OK subjects experienced 16 adverse events (7 significant and 9 non-significant). No adverse events were found in the SV group. Most adverse events were found between 6 and 12 months of lens wear, with 11 solely attributable to OK wear. Significantly more discontinuations were found with SV in comparison with OK (p < 0.05). Conclusions. The relatively low incidence of adverse events and discontinuations with OK is conducive for the correction of myopia in children with OK contact lenses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To examine the relation between ocular surface temperature (OST) assessed by dynamic thermal imaging and physical parameters of the anterior eye in normal subjects. METHODS. Dynamic ocular thermography (ThermoTracer 7102MX) was used to record body temperature and continuous ocular surface temperature for 8 s after a blink in the right eyes of 25 subjects. Corneal thickness, corneal curvature, and anterior chamber depth (ACD) were assessed using Orbscan II; noninvasive tear break-up time (NIBUT) was assessed using the tearscope; slit lamp photography was used to record tear meniscus height (TMH) and objective bulbar redness. RESULTS. Initial OST after a blink was significantly correlated only with body temperature (r = 0.80, p < 0.0005), NIBUT (r = -0.68, p < 0.005) and corneal curvature (r = -0.40, p = 0.05). A regression model containing all the variables accounted for 70% (p = 0.002) of the variance in OST, of which NIBUT (29%, p = 0.004), and body temperature (18%, p = 0.005) contributed significantly. CONCLUSIONS. The results support previous theoretical models that OST radiation is principally related to the tear film; and demonstrate that it is less related to other characteristics such as corneal thickness, corneal curvature, and anterior chamber depth. © 2007 American Academy of Optometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. The purpose of this study was to evaluate the longitudinal changes in ocular physiology, tear film characteristics, and symptomatology experienced by neophyte silicone hydrogel (SiH) contact lens wearers in a daily-wear compared with a continuous-wear modality and with the different commercially available lenses over an 18-month period. Methods. Forty-five neophyte subjects were enrolled in the study and randomly assigned to wear one of two SiH materials: lotrafilcon A or balafilcon A lenses on either a daily- (LDW; BDW) or continuous-wear (LCW; BCW) basis. Additionally, a group of noncontact lens-wearing subjects (control group) was also recruited and followed over the same study period. Objective and subjective grading of ocular physiology were carried out together with tear meniscus height (TMH) and noninvasive tear breakup time (NITBUT). Subjects also subjectively rated symptoms and judgments with lens wear. After initial screening, subsequent measurements were taken after 1, 3, 6, 12, and 18 months. Results. Subjective and objective grading of ocular physiology revealed a small increase in bulbar, limbal, and palpebral hyperemia as well as corneal staining over time with both lens materials and regimes of wear (p < 0.05). No significant changes in NITBUT or TMH were found (p > 0.05). Subjective symptoms and judgment were not material- or modality-specific. Conclusions. Daily and continuous wear of SiH contact lenses induced small but statistically significant changes in ocular physiology and symptomatology. Clinical measures of tear film characteristics were unaffected by lens wear. Both materials and regimes of wear showed similar clinical performance. Long-term SiH contact lens wear is shown to be a successful option for patients. Copyright © 2006 American Academy of Optometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. The purpose of this study was to evaluate the potential of the portable Grand Seiko FR-5000 autorefractor to allow objective, continuous, open-field measurement of accommodation and pupil size for the investigation of the visual response to real-world environments and changes in the optical components of the eye. METHODS. The FR-5000 projects a pair of infrared horizontal and vertical lines on either side of fixation, analyzing the separation of the bars in the reflected image. The measurement bars were turned on permanently and the video output of the FR-5000 fed into a PC for real-time analysis. The calibration between infrared bar separation and the refractive error was assessed over a range of 10.0 D with a model eye. Tolerance to longitudinal instrument head shift was investigated over a ±15 mm range and to eye alignment away from the visual axis over eccentricities up to 25.0°. The minimum pupil size for measurement was determined with a model eye. RESULTS. The separation of the measurement bars changed linearly (r = 0.99), allowing continuous online analysis of the refractive state at 60 Hz temporal and approximately 0.01 D system resolution with pupils >2 mm. The pupil edge could be analyzed on the diagonal axes at the same rate with a system resolution of approximately 0.05 mm. The measurement of accommodation and pupil size were affected by eccentricity of viewing and instrument focusing inaccuracies. CONCLUSIONS. The small size of the instrument together with its resolution and temporal properties and ability to measure through a 2 mm pupil make it useful for the measurement of dynamic accommodation and pupil responses in confined environments, although good eye alignment is important. Copyright © 2006 American Academy of Optometry.