4 resultados para 0.0 per mil

em Aston University Research Archive


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Silicone elastomers are commonly used in the manufacture of single-piece joint replacement implants for the finger joints. However, the survivorship of these implants can be poor, with failure typically occurring from fracture of the stems. The aim of this paper was to investigate the crack growth of medical-grade silicone using pure shear tests. Two medical-grade silicones (C6-180 and Med82-5010-80) were tested. Each sample had a 20 mm crack introduced and was subjected to a sinusoidally varying tensile strain, with a minimum of 0 per cent and a maximum in the range 10 to 77 per cent. Testing was undertaken at a frequency of 10 Hz. At various times during testing, the testing machine was stopped, the number of cycles completed was noted, and the crack length measured. Graphs of crack length against number of cycles were plotted, as well as the crack growth rate against tearing energy. The results show that Med82-5010-80 is more crack resistant than C6-180. Graphs of crack growth rate against tearing energy can be used to predict the failure of these medical-grade elastomers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. Setting: Six UK maternity units. Participants: These were 20,055 asymptomatic newborns at = 35 weeks’ gestation, their mothers and health-care staff. Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). Main outcome measures: Detection of major CHDs – defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Prescribing magnification is typically based on distance or near visual acuity. this presumes a constant minimum angle of visual resolution with working distance and therefore enlargement of an object moved to a shorter working distance (relative distance enlargement). this study examines this premise in a visually impaired population. methods: distance letter visual acuity was measured prospectively for 380 low vision patients (distance visual acuity between 0.3 and 2.1 logmar) over the age of 57 years, along with near word visual acuity at an appropriate distance for near lens additions from +4 d to +20 D. demographic information, the disease causing low vision, contrast sensitivity, visual field and psychological status were also recorded. results: distance letter acuity was significantly related to (r = 0.84) but on average 0.1 ± 0.2 logmar better (1 ± 2 lines on a logmar chart) than near word acuity at 25 cm with a +4 d lens addition. in 39. 8 per cent of patients, near word acuity was more than 0.1 logmar worse than distance letter acuity. in 11.0 per cent of subjects, near visual acuity was more than 0.1 logmar better than distance letter acuity. the group with near word acuity worse than distance letter acuity also had lower contrast sensitivity. the group with near word acuity better than distance letter acuity was less likely to have age-Related macular degeneration. smaller print size could be read by reducing working distance (achieved by using higher near lens additions) in 86. 1 per cent, although not by as much as predicted by geometric progression in 14. 5 per cent. discussion: although distance letter and near word acuity are highly related, they are on average 1 logmar line different and this varies significantly between individuals. near word acuity did not increase linearly with relative distance enlargement in approximately one in seven visually impaired, suggesting that the measurement of visual resolution over a range of working distances will assist appropriate prescribing of magnification aids.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Objective - To evaluate long-term safety of intravitreal ranibizumab 0.5-mg injections in neovascular age-related macular degeneration (nAMD). Design - Twenty-four–month, open-label, multicenter, phase IV extension study. Participants - Two hundred thirty-four patients previously treated with ranibizumab for 12 months in the EXCITE/SUSTAIN study. Methods - Ranibizumab 0.5 mg administered at the investigator's discretion as per the European summary of product characteristics 2007 (SmPC, i.e., ranibizumab was administered if a patient experienced a best-corrected visual acuity [BCVA] loss of >5 Early Treatment Diabetic Retinopathy Study letters measured against the highest visual acuity [VA] value obtained in SECURE or previous studies [EXCITE and SUSTAIN], attributable to the presence or progression of active nAMD in the investigator's opinion). Main Outcome Measures - Incidence of ocular or nonocular adverse events (AEs) and serious AEs, mean change in BCVA from baseline over time, and the number of injections. Results - Of 234 enrolled patients, 210 (89.7%) completed the study. Patients received 6.1 (mean) ranibizumab injections over 24 months. Approximately 42% of patients had 7 or more visits at which ranibizumab was not administered, although they had experienced a VA loss of more than 5 letters, indicating either an undertreatment or that factors other than VA loss were considered for retreatment decision by the investigator. The most frequent ocular AEs (study eye) were retinal hemorrhage (12.8%; 1 event related to study drug), cataract (11.5%; 1 event related to treatment procedure), and increased intraocular pressure (6.4%; 1 event related to study drug). Cataract reported as serious due to hospitalization for cataract surgery occurred in 2.6% of patients; none was suspected to be related to study drug or procedure. Main nonocular AEs were hypertension and nasopharyngitis (9.0% each). Arterial thromboembolic events were reported in 5.6% of the patients. Five (2.1%) deaths occurred during the study, none related to the study drug or procedure. At month 24, mean BCVA declined by 4.3 letters from the SECURE baseline. Conclusions - The SECURE study showed that ranibizumab administered as per a VA-guided flexible dosing regimen recommended in the European ranibizumab SmPC at the investigator's discretion was well tolerated over 2 years. No new safety signals were identified in patients who received ranibizumab for a total of 3 years. On average, patients lost BCVA from the SECURE study baseline, which may be the result of disease progression or possible undertreatment.