109 resultados para intraocular lens
Resumo:
The principal theme of this thesis is the identification of additional factors affecting, and consequently to better allow, the prediction of soft contact lens fit. Various models have been put forward in an attempt to predict the parameters that influence soft contact lens fit dynamics; however, the factors that influence variation in soft lens fit are still not fully understood. The investigations in this body of work involved the use of a variety of different imaging techniques to both quantify the anterior ocular topography and assess lens fit. The use of Anterior-Segment Optical Coherence Tomography (AS-OCT) allowed for a more complete characterisation of the cornea and corneoscleral profile (CSP) than either conventional keratometry or videokeratoscopy alone, and for the collection of normative data relating to the CSP for a substantial sample size. The scleral face was identified as being rotationally asymmetric, the mean corneoscleral junction (CSJ) angle being sharpest nasally and becoming progressively flatter at the temporal, inferior and superior limbal junctions. Additionally, 77% of all CSJ angles were within ±50 of 1800, demonstrating an almost tangential extension of the cornea to form the paralimbal sclera. Use of AS-OCT allowed for a more robust determination of corneal diameter than that of white-to-white (WTW) measurement, which is highly variable and dependent on changes in peripheral corneal transparency. Significant differences in ocular topography were found between different ethnicities and sexes, most notably for corneal diameter and corneal sagittal height variables. Lens tightness was found to be significantly correlated with the difference between horizontal CSJ angles (r =+0.40, P =0.0086). Modelling of the CSP data gained allowed for prediction of up to 24% of the variance in contact lens fit; however, it was likely that stronger associations and an increase in the modelled prediction of variance in fit may have occurred had an objective method of lens fit assessment have been made. A subsequent investigation to determine the validity and repeatability of objective contact lens fit assessment using digital video capture showed no significant benefit over subjective evaluation. The technique, however, was employed in the ensuing investigation to show significant changes in lens fit between 8 hours (the longest duration of wear previously examined) and 16 hours, demonstrating that wearing time is an additional factor driving lens fit dynamics. The modelling of data from enhanced videokeratoscopy composite maps alone allowed for up to 77% of the variance in soft contact lens fit, and up to almost 90% to be predicted when used in conjunction with OCT. The investigations provided further insight into the ocular topography and factors affecting soft contact lens fit.
Resumo:
More information on the biochemical interactions taking place between the tear film and the contact lens is required to further our understanding of the causative mechanisms behind the symptoms of dryness and grittiness often experienced by contact lens wearers. These symptoms can often lead to an intolerance to contact lens wear.
Resumo:
The kinin family are a group of bioactive peptides that are closely involved in the modulation of vascular inflammation and local injury. We have demonstrated here, for the first time, a link between kinin activity and contact lens wear. Protein extracts from daily and extended wear etafilcon A, Group IV, Acuvue lenses (Vistakon), were analysed by counter immunoelectrophoresis. In this way, kinin activity associated with contact lens wear was detected. High molecular weight kininogen was used as the marker protein. In contrast, no kinin activity was detected in the non-lens wearing normal eye. © 2002 British Contact Lens Association. Published by Elsevier Science Ltd. All rights reserved.
Resumo:
Many factors can be, and have been, attributed to the appearance of complications in lens wear, but the greatest is associated with deposition. Reduced acuity, irritation and inflammatory responses are often referred to as adverse reactions arising as a result of deposition. In this study, particular attention was paid to the potential role of adsorbed proteins in activating, mediating and/or stimulating a host immune response, i.e., the hypothesis that the adsorption of certain proteins from the tears and ocular surfaces may actively affect successful lens wear. In particular, the purpose of this study was to investigate the presence of a group of proteins previously undiscovered in the ocular environment. The intention was to target a family of proteins/glycoproteins that have become prominent recently in a variety of inflammatory responses and disorders at many other mucosal associated sites around the body, e.g. in nasal rhinitis and in joint inflammation. The protein cascade in question is the kinin family of inflammatory mediators. The aim was to investigate their presence in the ocular environment, specifically in relation to contact lens wear, and consequently assess the implications of their discovery. High molecular weight kininogen (HMWK), with its central role in kinin responses, was investigated initially as the marker of kinin activity, with subsequent members examined thereafter.
Resumo:
As we settle into a new year, this second issue of Contact Lens and Anterior Eye allows us to reflect on how new research in this field impacts our understanding, but more importantly, how we use this evidence basis to enhance our day to day practice, to educate the next generation of students and to construct the research studies to deepen our knowledge still further. The end of 2014 saw the publication of the UK governments Research Exercise Framework (REF) which ranks Universities in terms of their outputs (which includes their paper, publications and research income), environment (infrastructure and staff support) and for the first time impact (defined as “any effect on, change or benefit to the economy, society, culture, public policy or services, health, the environment or quality of life, beyond academia” [8]). The REF is a process of expert review, carried out in 36 subject-based units of assessment, of which our field is typically submitted to the Allied Health, Dentistry, Nursing and Pharmacy panel. Universities that offer Optometry did very well with Cardiff, Manchester and Aston in the top 10% out of the 94 Universities that submitted to this panel (Grade point Average ranked order). While the format of the new exercise (probably in 2010) to allocate the more than £2 billion of UK government research funds is yet to be determined, it is already rumoured that impact will contribute an even larger proportion to the weighting. Hence it is even more important to reflect on the impact of our research. In this issue, Elisseef and colleagues [5] examine the intriguing potential of modifying a lens surface to allow it to bind to known wetting agents (in this case hyaluronic acid) to enhance water retention. Such a technique has the capacity to reduced friction between the lens surface and the eyelids/ocular surface, presumably leading to higher comfort and less reason for patients to discontinue with lens wear. Several papers in this issue report on the validity of new high precision, fast scanning imaging and quantification equipment, utilising techniques such as Scheimpflug, partial coherence interferometry, aberrometry and video allowing detailed assessment of anterior chamber biometry, corneal topography, corneal biomechanics, peripheral refraction, ocular aberrations and lens fit. The challenge is how to use this advanced instrumentation which is becoming increasingly available to create real impact. Many challenges in contact lenses and the anterior eye still prevail in 2015 such as: -While contact lens and refractive surgery complications are relatively rare, they are still too often devastating to the individual and their quality of life (such as the impact and prognosis of patients with Acanthmoeba Keratitis reported by Jhanji and colleagues in this issue [7]). How can we detect those patients who are going to be affected and what modifications do we need to make to contact lenses and patient management prevent this occurring? -Drop out from contact lenses still occurs at a rapid rate and symptoms of dry eye seem to be the leading cause driving this discontinuation of wear [1] and [2]. What design, coating, material and lubricant release mechanism will make a step change in end of day comfort in particular? -Presbyopia is a major challenge to hassle free quality vision and is one of the first signs of ageing noticed by many people. As an emmetrope approaching presbyopia, I have a vested interest in new medical devices that will give me high quality vision at all distances when my arms won’t stretch any further. Perhaps a new definition of presbyopia could be when you start to orientate your smartphone in the landscape direction to gain the small increase in print size needed to read! Effective accommodating intraocular lenses that truly mimic the pre-presbyopic crystalline lenses are still a way off [3] and hence simultaneous images achieved through contact lenses, intraocular lenses or refractive surgery still have a secure future. However, splitting light reaching the retina and requiring the brain to supress blurred images will always be a compromise on contrast sensitivity and is liable to cause dysphotopsia; so how will new designs account for differences in a patient's task demands and own optical aberrations to allow focused patient selection, optimising satisfaction? -Drug delivery from contact lenses offers much in terms of compliance and quality of life for patients with chronic ocular conditions such as glaucoma, dry eye and perhaps in the future, dry age-related macular degeneration; but scientific proof-of-concept publications (see EIShaer et al. [6]) have not yet led to commercial products. Part of this is presumably the regulatory complexity of combining a medical device (the contact lens) and a pharmaceutical agent. Will 2015 be the year when this innovation finally becomes a reality for patients, bringing them an enhanced quality of life through their eye care practitioners and allowing researchers to further validate the use of pharmaceutical contact lenses and propose enhancements as the technology matures? -Last, but no means least is the field of myopia control, the topic of the first day of the BCLA's Conference in Liverpool, June 6–9th 2015. The epidemic of myopia is a blight, particularly in Asia, with significant concerns over sight threatening pathology resulting from the elongated eye. This is a field where real impact is already being realised through new soft contact lens optics, orthokeratology and low dose pharmaceuticals [4], but we still need to be able to better predict which technique will work best for an individual and to develop new techniques to retard myopia progression in those who don’t respond to current treatments, without increasing their risk of complications or the treatment impacting their quality of life So what will your New Year's resolution be to make 2015 a year of real impact, whether by advancing science or applying the findings published in journals such as Contact Lens and Anterior Eye to make a real difference to your patients’ lives?
Resumo:
As we welcome 2014 we say goodbye to 2013 and I must start with an apology to authors who have submitted papers to CLAE and seen a delay in either the review process or the hard copy publication of their proofed article. The delays were caused by a major hike in the number of submissions to the journal in 2012 that increased further in 2013. In the 12 months leading to the end of October 2011 we had 94 new paper submissions, and for the same period to the end of 2012 the journal had 116 new papers. In 2012 we were awarded an impact factor for the first time and following that the next 12 month period to the end of October 2013 saw a massive increase in submissions with 171 new manuscripts being submitted. This is nearly twice as many papers as 2 years ago and 3 times as many as when I took over as Editor-in-Chief. In addition to this the UK academics will know that 2014 is a REF year (Research Excellence Framework) where universities are judged on their research and one of the major components of this measure remains to be published papers so there is a push to publishing before the REF deadline for counting. The rejection rate at CLAE has gone up too and currently is around 50% (more than double the rejection rate when I took over as Editor-in-Chief). At CLAE the number of pages that we publish each year has remained the same since 2007. When compiling issue 1 for 2014 I chose the papers to be included from the papers that were proofed and ready to go and there were around 200 proofed pages ready, which is enough to fill 3½ issues! At present Elsevier and the BCLA are preparing to increase the number the pages published per issue so that we can clear some of this backlog and remain up to date with the papers published in CLAE. I should add that on line publishing of papers is still available and there may have been review delays but there are no publishing online so authors can still get an epub on line final version of their paper with a DOI (digital object identifier) number enabling the paper to be cited. There are two awards that were made in 2013 that I would like to make special mention of. One was for my good friend Jan Bergmanson, who was awarded an honorary life fellowship of the College of Optometrists. Jan has served on the editorial board of CLAE for many years and in 2013 also celebrated 30 years of his annual ‘Texan Corneal and contact lens meeting’. The other award I wish to mention is Judith Morris, who was the BCLA Gold Medal Award winner in 2013. Judith has had many roles in her career and worked at Moorfields Eye Hospital, the Institute of Optometry and currently at City University. She has been the Europe Middle East and Africa President of IACLE (International Association of Contact Lens Educators) for many years and I think I am correct in saying that Judith is the only person who was President of both the BCLA (1983) and a few years later she was the President College of Optometrists (1989). Judith was also instrumental in introducing Vivien Freeman to the BCLA as they had been friends and Judith suggested that Vivien apply for an administrative job at the BCLA. Fast forward 29 years and in December 2013 Vivien stepped down as Secretary General of the BCLA. I would like to offer my own personal thanks to Vivien for her support of CLAE and of me over the years. The BCLA will not be the same and I wish you well in your future plans. But 2014 brings in a new position to the BCLA – Cheryl Donnelly has been given the new role of Chief Executive Officer. Cheryl was President of the BCLA in 2000 and has previously served on council. I look forward to working with Cheryl and envisage a bright future for the BCLA and CLAE. In this issue we have some great papers including some from authors who have not published with CLAE before. There is a nice paper on contact lens compliance in Nepal which brings home some familiar messages from an emerging market. A paper on how corneal curvature is affected by the use of hydrogel lenses is useful when advising patients how long they should leave their contact lenses out for to avoid seeing changes in refraction or curvature. This is useful information when refracting these patients or pre-laser surgery. There is a useful paper offering tips on fitting bitoric gas permeable lenses post corneal graft and a paper detailing surgery to implant piggyback multifocal intraocular lenses. One fact that I noted from the selection of papers in the current issue is where they were from. In this issue none of the corresponding authors are from the United Kingdom. There are two papers each from the United States, Spain and Iran, and one each from the Netherlands, Ireland, Republic of Korea, Australia and Hong Kong. This is an obvious reflection of the widening interest in CLAE and the BCLA and indicates the new research groups emerging in the field.
Resumo:
PURPOSE: To examine the optimum time at which fluorescein patterns of gas permeable lenses (GPs) should be evaluated. METHODS: Aligned, 0.2mm steep and 0.2mm flat GPs were fitted to 17 patients (aged 20.6±1.1 years, 10 male). Fluorescein was applied to their upper temporal bulbar conjunctiva with a moistened fluorescein strip. Digital slit lamp images (CSO, Italy) at 10× magnification of the fluorescein pattern viewed with blue light through a yellow filter were captured every 15s. Fluorescein intensity in central, mid peripheral and edge regions of the superior, inferior, temporal and nasal quadrants of the lens were graded subjectively using a +2 to -2 scale and using ImageJ software on the simultaneously captured images. RESULTS: Subjectively graded and objectively image analysed fluorescein intensity changed with time (p<0.001), lens region (centre, mid-periphery and edge: p<0.05) and there was interaction between lens region with lens fit (p<0.001). For edge band width, there was a significant effect of time (F=118.503, p<0.001) and lens fit (F=5.1249, p=0.012). The expected alignment, flat and steep fitting patterns could be seen from approximately after 30 to 180s subjectively and 15 to 105s in captured images. CONCLUSION: Although the stability of fluorescein intensity can start to decline in as little as 45s post fluorescein instillation, the diagnostic pattern of alignment, steep or flat fit is seen in each meridian by subjective observation from about 30s to 3min indicating this is the most appropriate time window to evaluate GP lenses in clinical practice.
Resumo:
Aim: To appraise history and symptom taking for contact lens consultations, to determine current practice and to make recommendations for best practice. Method: The peer reviewed academic literature was reviewed and the results informed a survey completed by 256 eye care practitioners (ECPs) on their current practice and influences. Results: The last eye-test date, last contact lens aftercare (for existing wearers) and reason for visit are key questions for most ECPs. Detailed use of contact lens questions are more commonly applied in aftercares than when refitting patients who have previously discontinued wear (87% vs 56% use), whereas questions on ocular and general history, medication and lifestyle were generally more commonly utilised for new patients than in aftercares (72% vs 50%). 75% of ECPs requested patients bring a list of their medication to appointments. Differential diagnosis questioning was thorough in most ECPs (87% of relevant questions asked). Attempts to optimise compliance included oral instruction (95% always) and written patient instructions (95% at least sometimes). Abbreviations were used by 39% of respondents (26% used ones provided by a professional body). Conclusion: There is scope for more consistency in history and symptom taking for contact lens consultations and recommendations are made.
Resumo:
Purpose: To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Methods: Thirty-nine subjects (22.1. ±. 3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16. h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Results: Lens fit assessments were not different between brands (P > 0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12. h (P <. 0.05), but remained stable from 12 to 16. h (P > 0.05). Movement-on-blink was unaffected by wear-time (F = 0.403, P = 0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r = -0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P > 0.01). Conclusions: Among the lenses tested, objective lens fit changed between 8. h and 12. h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit.
Resumo:
Pseudophakic patients are frequently encountered in optometric practice, often the result of cataract extraction but also presbyopia correction. Given advances in technology and surgery, the demand for intraocular lenses for correcting a variety of refractive requirements has increased owing to an ageing population. Based on the patient’s needs, either fixed focus, toric, accommodating or multifocal intraocular lenses (IOLs) may be implanted. During optometric examination, attention should be drawn to a history of IOLs and the potential complications they may cause in order to manage them effectively, particularly where sight is threatened. Although objective and subjective refraction does not differ greatly between phakic and pseudophakic patients, care should be taken to set the patient up correctly and the reflex during retinoscopy observed for posterior sub-capsular opacification. Additional tests such as reading speed, and glare and contrast sensitivity are necessary to determine the outcome of IOL surgery and detect potential problems associated with multifocal and accommodating IOLs. Based upon the results of these tests, refraction, and type of IOL, contact lens or spectacle correction may be required to meet the visual demands of the patient.
Resumo:
Purpose: To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically-powered RGP (rigid gas-permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15°) and translation (up to 1mm) from their ideal position. Methods: The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point-spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher-order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation. Results: In agreement with the results of other authors, the RGP lenses markedly reduced both lower-order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies. Conclusions: At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort. © 2012 The College of Optometrists.
Resumo:
Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p <. 0.001). Horizontal lens centration was on average close to central as assessed both objectively and subjectively (p > 0.05). The 95% confidence interval of subjective repeatability was better than objective assessment (±0.128. mm versus ±0.168. mm, p = 0.417), but utilised only 78% of the objective range. Vertical centration assessed objectively showed a slight inferior decentration (0.371. ±. 0.381. mm) with good inter- and intrasession repeatability (p > 0.05). Movement-on-blink was lower estimated subjectively than measured objectively (0.269. ±. 0.179. mm versus 0.352. ±. 0.355. mm; p = 0.035), but had better repeatability (±0.124. mm versus ±0.314. mm 95% confidence interval) unless correcting for the smaller range (47%). Horizontal lag was lower estimated subjectively (0.562. ±. 0.259. mm) than measured objectively (0.708. ±. 0.374. mm, p <. 0.001), had poorer repeatability (±0.132. mm versus ±0.089. mm 95% confidence interval) and had a smaller range (63%). Subjective categorisation of push-up speed of recovery showed reasonable differentiation relative to objective measurement (p <. 0.001). Conclusions: The objective image analysis allows an accurate, reliable and repeatable assessment of soft contact lens fit characteristics, being a useful tool for research and optimisation of lens fit in clinical practice.
Resumo:
The literature suggests that diabetic patients may have altered tear chemistry and tear secretion as well as structural and functional changes to the corneal epithelium, endothelium and nerves. These factors, together with a reported increased incidence of corneal infection, suggest that diabetic patients may be particularly susceptible to developing ocular complications during contact lens wear. Reports of contact lens-induced complications in diabetic patients do exist, although a number of these reports concern patients with advanced diabetic eye disease using lenses on an extended wear basis. Over the past decade or so, there have been published studies documenting the response of the diabetic eye to more modern contact lens modalities. The results of these studies suggest that contact lenses can be a viable mode of refractive correction for diabetic patients. Furthermore, new research suggests that the measurement of tear glucose concentration could, in future, be used to monitor metabolic control non-invasively in diabetic patients. This could be carried out using contact lenses manufactured from hydrogel polymers embedded with glucose-sensing agents or nanoscale digital electronic technology. The purpose of this paper is to review the literature on the anterior ocular manifestations of diabetes, particularly that pertaining to contact lens wear. © 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.
Resumo:
Lipids play a vital role in the body at many interfaces. Examples include the lubrication of articulating joints by synovial fluid, the coating of the lung by pulmonary surfactant and the functions of the tear film in the protection of the anterior eye. The role of the lipids is similar at each site - acting as boundary lubricants and reducing surface and interfacial tension. This review focuses on how and why contact lens wear can disrupt the normal function of lipids within the tear film and explains how the otherwise advantageous presence and function of tear lipids can become disadvantageous, causing problems for the wearer. Because the contact lens is some ten times thicker than the tear film, lipids deposited on the anterior surface become immobilised, reducing lipid turnover and thus leading to prolonged exposure to oxygen and light with consequent generation of degradation products. These degraded lipids reduce lens wettability and have additionally been linked to problems of contact lens discomfort and intolerance. Lipid problems are influenced by the thickness of the lens, the material, surface modification, mode of wear and ultimately the subject. The most influential of these variables is frequently the subject. © 2012.