113 resultados para Visual acuity.
Resumo:
Aim: Contrast sensitivity (CS) provides important information on visual function. This study aimed to assess differences in clinical expediency of the CS increment-matched new back-lit and original paper versions of the Melbourne Edge Test (MET) to determine the CS of the visually impaired. Methods: The back-lit and paper MET were administered to 75 visually impaired subjects (28-97 years). Two versions of the back-lit MET acetates were used to match the CS increments with the paper-based MET. Measures of CS were repeated after 30 min and again in the presence of a focal light source directed onto the MET. Visual acuity was measured with a Bailey-Lovie chart and subjects rated how much difficulty they had with face and vehicle recognition. Results: The back-lit MET gave a significantly higher CS than the paper-based version (14.2 ± 4.1 dB vs 11.3 ± 4.3 dB, p < 0.001). A significantly higher reading resulted with repetition of the paper-based MET (by 1.0 ± 1.7 dB, p < 0.001), but this was not evident with the back-lit MET (by 0.1 ± 1.4 dB, p = 0.53). The MET readings were increased by a focal light source, in both the back-lit (by 0.3 ± 0.81, p < 0.01) and paper-based (1.2 ± 1.7, p < 0.001) versions. CS as measured by the back-lit and paper-based versions of the MET was significantly correlated to patients' perceived ability to recognise faces (r = 0.71, r = 0.85 respectively; p < 0.001) and vehicles (r = 0.67, r = 0.82 respectively; p < 0.001), and with distance visual acuity (both r =-0.64; p < 0.001). Conclusions: The CS increment-matched back-lit MET gives higher CS values than the old paper-based test by approximately 3 dB and is more repeatable and less affected by external light sources. Clinically, the MET score provides information on patient difficulties with visual tasks, such as recognising faces. © 2005 The College of Optometrists.
Resumo:
Aim: To determine whether eyes implanted with the Lenstec KH-3500 "accommodative" intraocular lenses (IOLs) have improved subjective and objective focusing performance compared to a standard monofocal IOLs. Methods: 28 participants were implanted monocularly with a KH-3500 " accommodative" IOL and 20 controls with a Softec1 IOL. Outcome measures of refraction, visual acuity, subjective amplitude of accommodation, objective accommodative stimulus response curve, aberrometry, and Scheimpflug imaging were taken at ∼3 weeks and repeated after 6 months. Results: Best corrected acuity with the KH-3500 was 0.06 (SD 0.13) logMAR at distance and 0.58 (0.20) logMAR at near. Accommodation was 0.39 (0.53) D measured objectively and 3.1 (1.6) D subjectively. Higher order aberrations were 0.87 (0.85) μm and lower order were 0.24 (0.39) μm. Posterior subcapsular light scatter was 0.95% (1.37%) greater than IOL clarity. In comparison, all control group measures were similar except objective (0.17 (0.13) D; p = 0.032) and subjective (2.0 (0.9) D; p = 0.009) amplitude of accommodation. Six months following surgery, posterior subcapsular scatter had increased (p<0.01) in the KH-3500 implanted subjects and near word acuity had decreased (p<0.05). Conclusions: The objective accommodating effects of the KH-3500 IOL appear to be limited, although the subjective and objective accommodative range is significantly increased compared to control subjects implanted with conventional IOLs. However, this "accommodative" ability of the lens appears to have decreased by 6 months post-surgery.
Resumo:
PURPOSE. To compare the objective accommodative amplitude and dynamics of eyes implanted with the one-compartment-unit (1CU; HumanOptics AG, Erlangen, Germany) accommodative intraocular lenses (IOLs) with that measured subjectively. METHODS. Twenty eyes with a 1CU accommodative IOL implanted were refracted and distance and near acuity measured with a logMAR (logarithm of the minimum angle of resolution) chart. The objective accommodative stimulus-response curve for static targets between 0.17 and 4.00 D accommodative demand was measured with the SRW-5000 (Shin-Nippon Commerce Inc., Tokyo, Japan) and PowerRefractor (PlusOptiX, Nürnberg, Germany) autorefractors. Continuous objective recording of dynamic accommodation was measured with the SRW-5000, with the subject viewing a target moving from 0 to 2.50 D at 0.3 Hz through a Badal lens system. Wavefront aberrometry measures (Zywave; Bausch & Lomb, Rochester, NY) were made through undilated pupils. Subjective amplitude of accommodation was measured with the RAF (Royal Air Force accommodation and vergence measurement) rule. RESULTS. Four months after implantation best-corrected acuity was -0.01 ± 0.16 logMAR at distance and 0.60 ± 0.09 logMAR at near. Objectively, the static amplitude of accommodation was 0.72 ± 0.38 D. The average dynamic amplitude of accommodation was 0.71 ± 0.47 D, with a lag behind the target of 0.50 ± 0.48 seconds. Aberrometry showed a decrease in power of the lens-eye combination from the center to the periphery in all subjects (on average, -0.38 ± 0.28 D/mm). Subjective amplitude of accommodation was 2.24 ± 0.42 D. Two years after 1CU implantation, refractive error and distance visual acuity remained relatively stable, but near visual acuity, and the subjective and objective amplitudes of accommodation decreased. CONCLUSIONS. The objective accommodating effects of the 1CU lens appear to be limited, although patients are able to track a moving target. Subjective and objective accommodation was reduced at the 2-year follow-up. The greater subjective amplitude of accommodation is likely to result from the eye's depth of focus of and the aspheric nature of the IOL. Copyright © Association for Research in Vision and Ophthalmology.
Resumo:
The treatment of choroidal neovascularisation (CNV) secondary to pathological myopia has presented a number of problems to ophthalmologists over the years, but the advent of photodynamic therapy (PDT) with verteporfin has changed how we manage these patients. Until PDT became available, the use of laser photocoagulation for extra and juxtafoveal lesions had been shown to be effective in the short term in preventing loss of vision, although the risk of regrowth of CNV and undertreatment were well recognised. However, even in apparent successful cases of photocoagulation, laser scar enlargement and creepage into the fovea in the mid-to-long term often occurred with resulting loss of central vision.1 Other options for treatment were very limited with little evidence that other modalities such as transpupillary thermotherapy or submacular surgery and macular transplantation surgery would be successful in highly myopic eyes. The evidence for the role of PDT and verteporfin CNV secondary to pathological myopia comes from the verteporfin in photodynamic therapy (VIP) study that has shown how effective this treatment is in eyes with subfoveal CNV.2, 3 Now in this publication, Lam et al4 from Hong Kong have shown that PDT is also effective in juxtafoveal CNV, with high myopia. They performed a small prospective study of 11 patients of mean age 44.8 years, with 12 months of follow-up. They found that there was a mean improvement of 1.8 lines of LogMAR best-corrected visual acuity (BCVA) at 12 months, with a mean number of 2.3 PDT treatments. The most rapid improvement occurred within the first 3 months of treatment and by 12 months none of the patients had suffered a deterioration in BCVA from baseline. There were no cases of adverse effects from the infusion or laser treatment. For ophthalmologists dealing with patients with CNV secondary to causes other than AMD, this is further evidence of the effectiveness of PDT with verteporfin in maintaining vision. These patients are likely to be younger than those with AMD and are likely to be in active employment and supporting families, and clearly the preservation of best vision possible is imperative in this group. It is therefore encouraging for ophthalmologists in the United Kingdom that the verteporfin in PDT Cohort Study (VPDT Study) includes the ability to treat patients with subfoveal CNV secondary to high myopia if they fulfill National Institute of Clinical Excellence guidelines, and will allow representations to be made on an individual basis for treatment of juxtafoveal lesions.5 For those ophthalmologists used to juggling increased patient expectations with scarce NHS resources, this is promising news and will allow us to offer a better standard of care to our patients.
Resumo:
Background/aims To investigate the efficacy and safety of the MGDRx EyeBag (The Eyebag Company, Halifax, UK) eyelid warming device. Methods Twenty-five patients with confirmed meibomian gland dysfunction (MGD)-related evaporative dry eye were enrolled into a randomised, single masked, contralateral clinical trial. Test eyes received a heated device; control eyes a non-heated device for 5 min twice a day for 2 weeks. Efficacy (ocular symptomology, noninvasive break-up time, lipid layer thickness, osmolarity, meibomian gland dropout and function) and safety (visual acuity, corneal topography, conjunctival hyperaemia and staining) measurements were taken at baseline and follow-up. Subsequent patient device usage and ocular comfort was ascertained at 6 months. Results Differences between test and control eyes at baseline were not statistically signi ficant for all measurements ( p>0.05). After 2 weeks, statistically significant improvements occurred in all efficacy measurements in test eyes ( p<0.05). Visual acuity and corneal topography were unaffected (p>0.05). All patients maintained higher ocular comfort after 6 months ( p<0.05), although the bene fit was greater in those who continued usage 1-8 times a month (p<0.001). Conclusions The MGDRx EyeBag is a safe and effective device for the treatment of MGD-related evaporative dry eye. Subjective benefit lasts at least 6 months, aided by occasional retreatment. Trial registration number NCT01870180.
Surface roughness after excimer laser ablation using a PMMA model:profilometry and effects on vision
Resumo:
PURPOSE: To show that the limited quality of surfaces produced by one model of excimer laser systems can degrade visual performance with a polymethylmethacrylate (PMMA) model. METHODS: A range of lenses of different powers was ablated in PMMA sheets using five DOS-based Nidek EC-5000 laser systems (Nidek Technologies, Gamagori, Japan) from different clinics. Surface quality was objectively assessed using profilometry. Contrast sensitivity and visual acuity were measured through the lenses when their powers were neutralized with suitable spectacle trial lenses. RESULTS: Average surface roughness was found to increase with lens power, roughness values being higher for negative lenses than for positive lenses. Losses in visual contrast sensitivity and acuity measured in two subjects were found to follow a similar pattern. Findings are similar to those previously published with other excimer laser systems. CONCLUSIONS: Levels of surface roughness produced by some laser systems may be sufficient to degrade visual performance under some circumstances.
Resumo:
Aim: To examine the academic literature on the grading of corneal transparency and to assess the potential use of objective image analysis. Method: Reference databases of academic literature were searched and relevant manuscripts reviewed. Annunziato, Efron (Millennium Edition) and Vistakon-Synoptik corneal oedema grading scale images were analysed objectively for relative intensity, edges detected, variation in intensity and maximum intensity. In addition, corneal oedema was induced in one subject using a low oxygen transmissibility (Dk/t) hydrogel contact lens worn for 3 hours under a light eye patch. Recovery from oedema was monitored over time using ultrasound pachymetry, high and low contrast visual acuity measures, bulbar hyperaemia grading and transparency image analysis of the test and control eyes. Results: Several methods for assessing corneal transparency are described in the academic literature, but none have gained widespread in clinical practice. The change in objective image analysis with printed scale grade was best described by quadratic parametric or sigmoid 3-parameter functions. ‘Pupil image scales’ (Annunziato and Vistakon-Synoptik) were best correlated to average intensity; however, the corneal section scale (Efron) was strongly correlated to variations in intensity. As expected, patching an eye wearing a low Dk/t hydrogel contact lens caused a significant (F=119.2, P<0.001) 14.3% increase in corneal thickness, which gradually recovered under open eye conditions. Corneal section image analysis was the most affected parameter and intensity variation across the slit width, in isolation, was the strongest correlate, accounting for 85.8% of the variance with time following patching, and 88.7% of the variance with corneal thickness. Conclusion: Corneal oedema is best determined objectively by the intensity variation across the width of a corneal section. This can be easily measured using a slit-lamp camera connected to a computer. Oedema due to soft contact lens wear is not easily determined over the pupil area by sclerotic scatter illumination techniques.
Resumo:
Purpose: Tilted disc syndrome has been described to be associated with obliquely directed long axis of the disc, oblique direction of vessels, retinal pigment epithelial conus, hypoplasia of retina, visual field defects and myopic astigmatism. This prospective study looks at corneal astigmatism in eyes with a tilted optic disc. Refractive errors in these eyes were also analyzed. Methods: Patients with tilted optic discs were identified prospectively by clinical evaluation (BI, VK). All the patients with obliquely directed long axis of the disc, oblique direction of vessels and retinal pigment epithelial conus were included in the study. Best corrected visual acuity, slit-lamp examination, optic disc measurements, keratometry and refraction were recorded. Results: Twenty four patients (41 eyes) were recruited for the study. Eighteen (75%) patients had bilateral tilted optic discs. Eighteen patients (75%) were females and six (25%) were males. The mean age was 62 years(range 9 – 86 years). 76% of the patients were myopic and 24% hypermetropic. The mean spherical equivalent was –7.49 dioptres (SD 1.7D, range +6D to -17D). The mean corneal astigmatism was 1.09D (SD 0.9D, range 0.25D to 3.80D). The 6 patients who had unilateral, untilted discs were used as a control group to compare their mean corneal astigmatism (1.32 D) with the rest. Student "t" test was performed. ("p" = 0.49). Conclusions: In our study, tilted disc syndrome was found to be largely bilateral and more commonly seen in females. Myopia was the commonest refractive error associated with this clinical condition. However, 24% of patients in this series were hypermetropic. No correlation between the tilting of the optic disc and significant corneal astigmatism was noted as previously reported.
Resumo:
Purpose: To evaluate and compare the functional and perceived benefits of wearing coloured lenses by patients with age-related macular degeneration (ARMD). Method: Ten subjects with early ARMD and five elderly controls wore a selection of NoIR wrap-around coloured lenses (yellow 29.7% light transmission, orange 22.9%, red 16.8% and grey 10.3%), each for a duration of 7 days. Contrast sensitivity, colour vision, visual acuity, the effect of glare and peripheral sensitivity were measured for each lens and compared with a control (no lens) condition. Subjective ratings of visual performance were also scored. Results: Compared with the no filter condition, red and grey lenses reduced contrast sensitivity whereas yellow and orange lenses increased contrast sensitivity. These objective changes were supported by subjective ratings in subjects with ARMD. Grey lenses reduced the loss of contrast sensitivity usually suffered in the presence of glare, whereas visual acuity and peripheral sensitivity decreased with red lenses. Colour vision became distorted with red lenses in control subjects, but was relatively unaffected by the use of coloured lenses in subjects with ARMD. Conclusions: The subjective benefit of coloured lenses appears to be due to a minor enhancement of contrast sensitivity. © 2002 The College of Optometrists.
Resumo:
Aims: To determine the visual outcome following initiation of brimonidine therapy in glaucoma. Methods: 16 newly diagnosed previously untreated glaucoma patients were randomly assigned to either timalal 0.5% or brimanidine 0.2%. Visual acuity, contrast sensitivity (CS), visual fields, intraocular pressure (IOP), blaad pressure, and heart rate were evaluated at baseline and after 3 months. Results: IOP reduction was similar far both groups (p<0.05). Brimanidine improved CS; in the right eye at 6 and 12 cpd (p = 0.043, p = 0.017); in the left eye at 3 and 12 cpd (p = 0.044, p = 0.046). Timolol reduced CS at 18 cpd in the right eye (p = 0.041). There was no change in any other measured parameters. Conclusion: Glaucoma patients exhibit improved CS an initiation of brimanidine therapy.
Resumo:
For more than a century it has been known that the eye is not a perfect optical system, but rather a system that suffers from aberrations beyond conventional prescriptive descriptions of defocus and astigmatism. Whereas traditional refraction attempts to describe the error of the eye with only two parameters, namely sphere and cylinder, measurements of wavefront aberrations depict the optical error with many more parameters. What remains questionable is the impact these additional parameters have on visual function. Some authors have argued that higher-order aberrations have a considerable effect on visual function and in certain cases this effect is significant enough to induce amblyopia. This has been referred to as ‘higher-order aberration-associated amblyopia’. In such cases, correction of higher-order aberrations would not restore visual function. Others have reported that patients with binocular asymmetric aberrations display an associated unilateral decrease in visual acuity and, if the decline in acuity results from the aberrations alone, such subjects may have been erroneously diagnosed as amblyopes. In these cases, correction of higher-order aberrations would restore visual function. This refractive entity has been termed ‘aberropia’. In order to investigate these hypotheses, the distribution of higher-order aberrations in strabismic, anisometropic and idiopathic amblyopes, and in a group of visual normals, was analysed both before and after wavefront-guided laser refractive correction. The results show: (i) there is no significant asymmetry in higher-order aberrations between amblyopic and fixing eyes prior to laser refractive treatment; (ii) the mean magnitude of higher-order aberrations is similar within the amblyopic and visually normal populations; (iii) a significant improvement in visual acuity can be realised for adult amblyopic patients utilising wavefront-guided laser refractive surgery and a modest increase in contrast sensitivity was observed for the amblyopic eye of anisometropes following treatment (iv) an overall trend towards increased higher-order aberrations following wavefront-guided laser refractive treatment was observed for both visually normal and amblyopic eyes. In conclusion, while the data do not provide any direct evidence for the concepts of either ‘aberropia’ or ‘higher-order aberration-associated amblyopia’, it is clear that gains in visual acuity and contrast sensitivity may be realised following laser refractive treatment of the amblyopic adult eye. Possible mechanisms by which these gains are realised are discussed.
Resumo:
Congenital nystagmus (CN) is an ocular-motor disorder characterised by involuntary, conjugated ocular oscillations and its pathogenesis is still under investigation. This kind of nystagmus is termed congenital (or infantile) since it could be present at birth or it can arise in the first months of life. Most of CN patients show a considerable decrease of their visual acuity: image fixation on the retina is disturbed by nystagmus continuous oscillations, mainly horizontal. However, the image of a given target can still be stable during short periods in which eye velocity slows down while the target image is placed onto the fovea (called foveation intervals). To quantify the extent of nystagmus, eye movement recording are routinely employed, allowing physicians to extract and analyse nystagmus main features such as waveform shape, amplitude and frequency. Using eye movement recording, it is also possible to compute estimated visual acuity predictors: analytical functions which estimates expected visual acuity using signal features such as foveation time and foveation position variability. Use of those functions extend the information from typical visual acuity measurement (e.g. Landolt C test) and could be a support for therapy planning or monitoring. This study focuses on detection of CN patients' waveform type and on foveation time measure. Specifically, it proposes a robust method to recognize cycles corresponding to the specific CN waveform in the eye movement pattern and, for those cycles, evaluate the exact signal tracts in which a subject foveates. About 40 eyemovement recordings, either infrared-oculographic or electrooculographic, were acquired from 16 CN subjects. Results suggest that the use of an adaptive threshold applied to the eye velocity signal could improve the estimation of slow phase start point. This can enhance foveation time computing and reduce influence of repositioning saccades and data noise on the waveform type identification.
Resumo:
Purpose: To evaluate the effect of reducing the number of visual acuity measurements made in a defocus curve on the quality of data quantified. Setting: Midland Eye, Solihull, United Kingdom. Design: Evaluation of a technique. Methods: Defocus curves were constructed by measuring visual acuity on a distance logMAR letter chart, randomizing the test letters between lens presentations. The lens powers evaluated ranged between +1.50 diopters (D) and -5.00 D in 0.50 D steps, which were also presented in a randomized order. Defocus curves were measured binocularly with the Tecnis diffractive, Rezoom refractive, Lentis rotationally asymmetric segmented (+3.00 D addition [add]), and Finevision trifocal multifocal intraocular lenses (IOLs) implanted bilaterally, and also for the diffractive IOL and refractive or rotationally asymmetric segmented (+3.00 D and +1.50 D adds) multifocal IOLs implanted contralaterally. Relative and absolute range of clear-focus metrics and area metrics were calculated for curves fitted using 0.50 D, 1.00 D, and 1.50 D steps and a near add-specific profile (ie, distance, half the near add, and the full near-add powers). Results: A significant difference in simulated results was found in at least 1 of the relative or absolute range of clear-focus or area metrics for each of the multifocal designs examined when the defocus-curve step size was increased (P<.05). Conclusion: Faster methods of capturing defocus curves from multifocal IOL designs appear to distort the metric results and are therefore not valid. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2013 ASCRS and ESCRS.
Resumo:
Presbyopia is a consequence of ageing and is therefore increasing inprevalence due to an increase in the ageing population. Of the many methods available to manage presbyopia, the use of contact lenses is indeed a tried and tested reversible option for those wishing to be spectacle free. Contact lens options to correct presbyopia include multifocal contact lenses and monovision.Several options have been available for many years with available guides to help choose multifocal contact lenses. However there is no comprehensive way to help the practitioner selecting the best option for an individual. An examination of the simplest way of predicting the most suitable multifocal lens for a patient will only enhance and add to the current evidence available. The purpose of the study was to determine the current use of presbyopic correction modalities in an optometric practice population in the UK and to evaluate and compare the optical performance of four silicone hydrogel soft multifocal contact lenses and to compare multifocal performance with contact lens monovision. The presbyopic practice cohort principal forms of refractive correction were distance spectacles (with near and intermediate vision providedby a variety of other forms of correction), varifocal spectacles and unaided distance with reading spectacles, with few patients wearing contact lenses as their primary correction modality. The results of the multifocal contact lens randomised controlled trial showed that there were only minor differences in corneal physiology between the lens options. Visual acuity differences were observed for distance targets, but only for low contrast letters and under mesopic lighting conditions. At closer distances between 20cm and 67cm, the defocus curves demonstrated that there were significant differences in acuity between lens designs (p < 0.001) and there was an interaction between the lens design and the level of defocus (p < 0.001). None of the lenses showed a clear near addition, perhaps due to their more aspheric rather than zoned design. As expected, stereoacuity was reduced with monovision compared with the multifocal contact lens designs, although there were some differences between the multifocal lens designs (p < 0.05). Reading speed did not differ between lens designs (F = 1.082, p = 0.368), whereas there was a significant difference in critical print size (F = 7.543, p < 0.001). Glare was quantified with a novel halometer and halo size was found to significantly differ between lenses(F = 4.101, p = 0.004). The rating of iPhone image clarity was significantly different between presbyopic corrections (p = 0.002) as was the Near Acuity Visual Questionnaire (NAVQ) rating of near performance (F = 3.730, p = 0.007).The pupil size did not alter with contact lens design (F = 1.614, p = 0.175), but was larger in the dominant eye (F = 5.489, p = 0.025). Pupil decentration relative to the optical axis did not alter with contact lens design (F = 0.777, p =0.542), but was also greater in the dominant eye (F = 9.917, p = 0.003). It was interesting to note that there was no difference in spherical aberrations induced between the contact lens designs (p > 0.05), with eye dominance (p > 0.05) oroptical component (ocular, corneal or internal: p > 0.05). In terms of subjective patient lens preference, 10 patients preferred monovision,12 Biofinity multifocal lens, 7 Purevision 2 for Presbyopia, 4 AirOptix multifocal and 2 Oasys multifocal contact lenses. However, there were no differences in demographic factors relating to lifestyle or personality, or physiological characteristics such as pupil size or ocular aberrations as measured at baseline,which would allow a practitioner to identify which lens modality the patient would prefer. In terms of the performance of patients with their preferred lens, it emerged that Biofinity multifocal lens preferring patients had a better high contrast acuity under photopic conditions, maintained their reading speed at smaller print sizes and subjectively rated iPhone clarity as better with this lens compared with the other lens designs trialled. Patients who preferred monovision had a lower acuity across a range of distances and a larger area of glare than those patients preferring other lens designs that was unexplained by the clinical metrics measured. However, it seemed that a complex interaction of aberrations may drive lens preference. New clinical tests or more diverse lens designs which may allow practitioners to prescribe patients the presbyopic contact lens option that will work best for them first time remains a hope for the future.
Resumo:
Congenital nystagmus (CN) is an ocular-motor disorder that appears at birth or during the first few months of life; it is characterised by involuntary, conjugated, bilateral to and fro ocular oscillations. Pathogenesis of congenital nystagmus is still unknown. Eye movement recording allow to extract and analyse nystagmus main features such as shape, amplitude and frequency; depending on the morphology of the oscillations nystagmus can be classified in different categories (pendular, jerk, horizontal unidirectional, bidirectional). In general, CN patient show a considerable decrease of the visual acuity: image fixation on the retina is disturbed by nystagmus continuous oscillations; however, image stabilisation is still achieved during the short foveation periods in which eye velocity slows down while the target image is placed onto the fovea. Visual acuity was found to be mainly dependent on foveation periods duration, but cycle-to-cycle foveation repeatability and reduction of retinal image velocities also contribute in increasing visual acuity. This study concentrate on cycle-to-cycle image position variation onto fovea, trying to characterise the sequences of foveation positions. Eye-movement (infrared oculographic or electro oculographic) recordings, relative to different gaze positions and belonging to more than 30 CN patients, were analysed. Preliminary results suggest that sequences of foveations show a cyclic pattern with a dominant frequency (around 0.3 Hz on average) much lower than that of the nystagmus (about 3.3 Hz on average). Sequences of foveations reveals an horizontal ocular swing of more than 2 degree on average, which can explain the low visual acuity of the CN patient. Current CN therapies, pharmacological treatment or surgery of the ocular muscles, mainly aim to increase the patient's visual acuity. Hence, it is fundamental to have an objective parameter (expected visual acuity) for therapy planning. The information about sequences of foveations can improve estimation of patient visual acuity. © 2008 Springer-Verlag.