96 resultados para Objective lenses
Resumo:
Purpose: To compare lens orientation and rotational recovery of five currently available soft toric lenses. Methods: Twenty subjects were recruited and trialed with each of the study lenses in a random order. Study lenses were PureVision® Toric (B&L), Air Optix® for Astigmatism (Alcon), Biofinity® Toric (CooperVision), Acuvue® Advance for Astigmatism (Vistakon), and Proclear® Toric (CooperVision). Lens orientation in primary position to determine the lens rotation form the vertical position and rotational recovery to primary gaze orientation following a 45° manual misorientation for the different lenses was compared. Results: The Biofinity Toric showed the lowest rotation from the vertical position and the Proclear Toric the highest. Also, the highest and the lowest reorientation speed were related to the Biofinity Toric and the Acuvue Advance for Astigmatism, respectively. The Repeated Measures ANOVA showed a significant difference in the lens rotation (P=. 0.004) and rotational recovery (P<. 0.001) among different contact lenses and the performed multiple comparisons indicated differences in rotation and also in reorientation speed were only seen between the Biofinity Toric when compared to four other lenses (P<. 0.05). Conclusion: Although there was appropriate fitting, based upon lens orientation and reorientation speed, with each of the study lenses it would appear that the optimized ballast technique used in the design of the Biofinity Toric helps reduce lens rotation and improve rotational recovery compared to others.
Resumo:
Purpose: To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Methods: Thirty-nine subjects (22.1. ±. 3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16. h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Results: Lens fit assessments were not different between brands (P > 0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12. h (P <. 0.05), but remained stable from 12 to 16. h (P > 0.05). Movement-on-blink was unaffected by wear-time (F = 0.403, P = 0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r = -0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P > 0.01). Conclusions: Among the lenses tested, objective lens fit changed between 8. h and 12. h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit.
Resumo:
Pseudophakic patients are frequently encountered in optometric practice, often the result of cataract extraction but also presbyopia correction. Given advances in technology and surgery, the demand for intraocular lenses for correcting a variety of refractive requirements has increased owing to an ageing population. Based on the patient’s needs, either fixed focus, toric, accommodating or multifocal intraocular lenses (IOLs) may be implanted. During optometric examination, attention should be drawn to a history of IOLs and the potential complications they may cause in order to manage them effectively, particularly where sight is threatened. Although objective and subjective refraction does not differ greatly between phakic and pseudophakic patients, care should be taken to set the patient up correctly and the reflex during retinoscopy observed for posterior sub-capsular opacification. Additional tests such as reading speed, and glare and contrast sensitivity are necessary to determine the outcome of IOL surgery and detect potential problems associated with multifocal and accommodating IOLs. Based upon the results of these tests, refraction, and type of IOL, contact lens or spectacle correction may be required to meet the visual demands of the patient.
Resumo:
Purpose: This study investigated how aberration-controlling, customised soft contact lenses corrected higher-order ocular aberrations and visual performance in keratoconic patients compared to other forms of refractive correction (spectacles and rigid gas-permeable lenses). Methods: Twenty-two patients (16 rigid gas-permeable contact lens wearers and six spectacle wearers) were fitted with standard toric soft lenses and customised lenses (designed to correct 3rd-order coma aberrations). In the rigid gas-permeable lens-wearing patients, ocular aberrations were measured without lenses, with the patient's habitual lenses and with the study lenses (Hartmann-Shack aberrometry). In the spectacle-wearing patients, ocular aberrations were measured both with and without the study lenses. LogMAR visual acuity (high-contrast and low-contrast) was evaluated with the patient wearing their habitual correction (of either spectacles or rigid gas-permeable contact lenses) and with the study lenses. Results: In the contact lens wearers, the habitual rigid gas-permeable lenses and customised lenses provided significant reductions in 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS and higher-order RMS error (p ≤ 0.004). In the spectacle wearers, the standard toric lenses and customised lenses significantly reduced 3rd-order RMS and higher-order RMS errors (p ≤ 0.005). The spectacle wearers showed no significant differences in visual performance measured between their habitual spectacles and the study lenses. However, in the contact lens wearers, the habitual rigid gas-permeable lenses and standard toric lenses provided significantly better high-contrast acuities compared to the customised lenses (p ≤ 0.006). Conclusions: The customised lenses provided substantial reductions in ocular aberrations in these keratoconic patients; however, the poor visual performances achieved with these lenses are most likely to be due to small, on-eye lens decentrations. © 2014 The College of Optometrists.
Resumo:
Purpose: To assess visual performance and ocular aberrations in keratoconic patients using toric soft contact lenses (SCL), rigid-gas-permeable (RGP) contact lenses and spectacle lens correction. Methods: Twenty-two keratoconus patients (16 RGP lens wearers and six spectacle wearers) were fitted with toric SCL. Ocular aberrations were measured with and without the patient's habitual RGP lenses and with the SCL in place. In the spectacle wearers, aberrations were measured with and without the SCL. Visual performance (high- and low-contrast visual acuity) was evaluated with the patient's habitual correction and with the SCL. Results: In the RGP lens wearers both the habitual lenses and the toric SCL significantly reduced coma, trefoil, 3rd-order, 4th-order cylinder and higher-order root-mean-square (RMS) aberrations (p≤0.015). In the spectacle wearers the toric SCL significantly reduced coma, 3rd-order and higher-order RMS aberrations (p≤0.01). The patients' habitual RGP lenses gave better low-contrast acuity (p≤0.006) compared to the toric SCL; however, no significant difference was found between lens types for high-contrast acuity (p=0.10). In the spectacle wearers no significant differences in visual performance measurements were found between the patients' spectacles and the toric SCL (p≥0.06). Conclusion: The results show that RGP lenses provided superior visual performances and greater reduction of 3rd-order aberrations compared to toric SCL in this group of keratoconic patients. In the spectacle-wearing group, visual performance with the toric SCL was found to be comparable to that measured with spectacles. Nevertheless, with the exception of spherical aberration, the toric SCL were successful in significantly reducing uncorrected higher-order aberrations. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.
Resumo:
Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p <. 0.001). Horizontal lens centration was on average close to central as assessed both objectively and subjectively (p > 0.05). The 95% confidence interval of subjective repeatability was better than objective assessment (±0.128. mm versus ±0.168. mm, p = 0.417), but utilised only 78% of the objective range. Vertical centration assessed objectively showed a slight inferior decentration (0.371. ±. 0.381. mm) with good inter- and intrasession repeatability (p > 0.05). Movement-on-blink was lower estimated subjectively than measured objectively (0.269. ±. 0.179. mm versus 0.352. ±. 0.355. mm; p = 0.035), but had better repeatability (±0.124. mm versus ±0.314. mm 95% confidence interval) unless correcting for the smaller range (47%). Horizontal lag was lower estimated subjectively (0.562. ±. 0.259. mm) than measured objectively (0.708. ±. 0.374. mm, p <. 0.001), had poorer repeatability (±0.132. mm versus ±0.089. mm 95% confidence interval) and had a smaller range (63%). Subjective categorisation of push-up speed of recovery showed reasonable differentiation relative to objective measurement (p <. 0.001). Conclusions: The objective image analysis allows an accurate, reliable and repeatable assessment of soft contact lens fit characteristics, being a useful tool for research and optimisation of lens fit in clinical practice.
Resumo:
Purpose: To assess the inter and intra observer variability of subjective grading of the retinal arterio-venous ratio (AVR) using a visual grading and to compare the subjectively derived grades to an objective method using a semi-automated computer program. Methods: Following intraocular pressure and blood pressure measurements all subjects underwent dilated fundus photography. 86 monochromatic retinal images with the optic nerve head centred (52 healthy volunteers) were obtained using a Zeiss FF450+ fundus camera. Arterio-venous ratios (AVR), central retinal artery equivalent (CRAE) and central retinal vein equivalent (CRVE) were calculated on three separate occasions by one single observer semi-automatically using the software VesselMap (ImedosSystems, Jena, Germany). Following the automated grading, three examiners graded the AVR visually on three separate occasions in order to assess their agreement. Results: Reproducibility of the semi-automatic parameters was excellent (ICCs: 0.97 (CRAE); 0.985 (CRVE) and 0.952 (AVR)). However, visual grading of AVR showed inter grader differences as well as discrepancies between subjectively derived and objectively calculated AVR (all p < 0.000001). Conclusion: Grader education and experience leads to inter-grader differences but more importantly, subjective grading is not capable to pick up subtle differences across healthy individuals and does not represent true AVR when compared with an objective assessment method. Technology advancements mean we no longer rely on opthalmoscopic evaluation but can capture and store fundus images with retinal cameras, enabling us to measure vessel calibre more accurately compared to visual estimation; hence it should be integrated in optometric practise for improved accuracy and reliability of clinical assessments of retinal vessel calibres. © 2014 Spanish General Council of Optometry.
Resumo:
In the past 30 years, organized crime (OC) has shifted from being an issue of little, or no concern, to being considered one of the key security threats facing the European Union (EU), the economic and political fabric of its society and its citizens. The purpose of this article is to understand how OC has come to be understood as one of the major security threats in the EU, by applying different lenses of Securitization Theory (ST). More specifically, the research question guiding this article is whether applying different ST approaches can lead us to draw differing conclusions as to whether OC has been successfully securitized in the EU. Building on the recent literature that argues that this theoretical framework has branched out into different approaches, this article wishes to contrast two alternative views of how a security problem comes into being, in order to verify whether different approaches can lead to diverging conclusions regarding the same phenomenon. The purpose of this exercise is to contribute to the further development of ST by pointing out that the choice in approach bears direct consequences on reaching a conclusion regarding the successful character of a securitization process. Starting from a reflection on ST, the article proceeds with applying a “linguistic approach” to the case study, which it then contrasts with a “sociological approach”. The article proposes that although the application of a “linguistic approach” seems to indicate that OC has become securitized in the EU, it also overlooks a number of elements, which the “sociological approach” renders visible and which lead us to refute the initial conclusion.
Resumo:
CONCLUSIONS: The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. PURPOSE: Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. METHODS: Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. RESULTS: Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively.
Resumo:
PURPOSE: To assess the performance of four commercially available silicone hydrogel multifocal monthly contact lens designs against monovision. METHODS: A double-masked randomized crossover trial of Air Optix Aqua multifocal, PureVision 2 for Presbyopia, Acuvue OASYS for Presbyopia, Biofinity multifocal, and monovision with Biofinity contact lenses was conducted on 35 presbyopes (54.3 ± 6.2 years). After 4 weeks of wear, visual performance was quantified by high- and low-contrast visual acuity under photopic and mesopic conditions, reading speed, defocus curves, stereopsis, halometry, aberrometry, Near Activity Visual Questionnaire rating, and subjective quality of vision scoring. Bulbar, limbal, and palpebral hyperemia and corneal staining were graded to monitor the impact of each contact lens on ocular physiology. RESULTS: High-contrast photopic visual acuity (p = 0.102), reading speed (F = 1.082, p = 0.368), and aberrometry (F = 0.855, p = 0.493) were not significantly different between presbyopic lens options. Defocus curve profiles (p <0.001), stereopsis (p <0.001), halometry (F = 4.101, p = 0.004), Near Activity Visual Questionnaire (F = 3.730, p = 0.007), quality of vision (p = 0.002), bulbar hyperemia (p = 0.020), and palpebral hyperemia (p = 0.012) differed significantly between lens types, with the Biofinity multifocal lens design principal (center-distance lens was fitted to the dominant eye and a center-near lens to the nondominant eye) typically outperforming the other lenses. CONCLUSIONS: Although ocular aberration variation between individuals largely masks the differences in optics between current multifocal contact lens designs, certain design strategies can outperform monovision, even in early presbyopes.
Resumo:
Heterogeneous multi-core FPGAs contain different types of cores, which can improve efficiency when used with an effective online task scheduler. However, it is not easy to find the right cores for tasks when there are multiple objectives or dozens of cores. Inappropriate scheduling may cause hot spots which decrease the reliability of the chip. Given that, our research builds a simulating platform to evaluate all kinds of scheduling algorithms on a variety of architectures. On this platform, we provide an online scheduler which uses multi-objective evolutionary algorithm (EA). Comparing the EA and current algorithms such as Predictive Dynamic Thermal Management (PDTM) and Adaptive Temperature Threshold Dynamic Thermal Management (ATDTM), we find some drawbacks in previous work. First, current algorithms are overly dependent on manually set constant parameters. Second, those algorithms neglect optimization for heterogeneous architectures. Third, they use single-objective methods, or use linear weighting method to convert a multi-objective optimization into a single-objective optimization. Unlike other algorithms, the EA is adaptive and does not require resetting parameters when workloads switch from one to another. EAs also improve performance when used on heterogeneous architecture. A efficient Pareto front can be obtained with EAs for the purpose of multiple objectives.
Resumo:
A number of clinical techniques are available to assess the visual and optical performance of the eye. This report aims to review the advantages and limitations of techniques used in previous studies of patients implanted with intraocular lenses (IOLs), whose designs are ever increasing in optical complexity. Although useful, in-vitro measurements of IOL optical quality cannot account for the wide range of biological variation in ocular anatomy and corneal optics, which will impact on the visual outcome achieved. This further highlights the need for a standardised series of visual performance tests that can be applied to a wide range of IOL designs. The conclusions of this report intend to assistresearchers in developing a comprehensive series of investigations to evaluate IOL performance. Repeatable and reproducible in-vivo assessments of visual and optical performance are desirable to further develop IOL concepts and designs, in the hope of improving current postoperative visual satisfaction. © 2013 Nova Science Publishers, Inc.
Resumo:
PURPOSE: To assess the surface tear breakup time and clinical performance of three daily disposable silicone hydrogel contact lenses over 16 hours of wear. METHODS: Thirty-nine patients (mean [±SD] age, 22.1 [±3.5] years) bilaterally wore (narafilcon A, filcon II-3, and delefilcon A) contact lenses in a prospective, randomized, masked, 1-week crossover clinical trial. Tear film was assessed by the tear meniscus height (TMH), ocular/contact lens surface temperature dynamics, and lens surface noninvasive breakup time at 8, 12, and 16 hours of wear. Clinical performance and ocular physiology were assessed by subjective questionnaire, by high-/low-contrast logMAR (logarithm of the minimum angle of resolution) acuity, and through bulbar and limbal hyperemia grading. Corneal and conjunctival staining were assessed after lens removal. RESULTS: Delefilcon A demonstrated a longer noninvasive breakup time (13.4 [±4.4] seconds) than filcon II-3 (11.6 [±3.7] seconds; p < 0.001) and narafilcon A (12.3 [±3.7] seconds; p < 0.001). A greater TMH (0.35 [±0.11] mm) was shown by delefilcon A than filcon II-3 (0.32 [±0.10] seconds; p = 0.016). Delefilcon A showed less corneal staining after 16 hours of lens wear (0.7 [±0.6] Efron grade) than filcon II-3 (1.1 [±0.7]; p < 0.001) and narafilcon A (0.9 [±0.7]; p = 0.031). Time was not a significant factor for prelens tear film stability (F = 0.594, p = 0.555) or TMH (F = 0.632, p = 0.534). Lens brand did not affect temperature (F = 1.220, p = 0.308), but it decreased toward the end of the day (F = 19.497, p < 0.001). Comfort, quality of vision, visual acuity and contrast acuity, and limbal grading were similar between the lens brands but decreased with time during the day (p < 0.05). CONCLUSIONS: The tear breakup time over the contact lens surface differed between lens types and may have a role in protecting the ocular surface.
Resumo:
Purpose - To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods - The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00 D and +6.00 D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results - The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p < 0.001) but no significant difference was found between the two powers of CLs. Conclusions - Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.
Resumo:
In this work, we investigate a new objective measurement for assessing the video playback quality for services delivered in networks that use TCP as a transport layer protocol. We define the new metric as pause intensity to characterize the quality of playback in terms of its continuity since, in the case of TCP, data packets are protected from losses but not from delays. Using packet traces generated from real TCP connections in a lossy environment, we are able to simulate the playback of a video and monitor buffer behaviors in order to calculate pause intensity values. We also run subjective tests to verify the effectiveness of the metric introduced and show that the results of pause intensity and the subjective scores made over the same real video clips are closely correlated.