161 resultados para wavelength multiplexing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a stable, dual-wavelength mode-locked fiber laser at 1 GHz with a wavelength spacing of 0.7 nm. Alternate switching between single and dual wavelength output was also achieved by simple adjustment of the pump power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A diode-cladding-pumped dual wavelength Q-switched Ho3+ -doped fluoride cascade fiber laser operating in the mid-infrared is demonstrated. Stable pulse trains from the 5|6 -> 5|7 and 5|7 -> 5|8 laser transitions were produced, and the µs-level time delay between the pulses from each transition was dependent on the pump power. At maximum pump power and at an acousto-optic modulator repetition rate of 25 kHz, the 5|8 -> 5|7 transition pulse operated at 3.005 µm, a pulse energy of 29 µJ, and a pulse width of 380 ns; the 5|7 -> 5|8 transition pulse correspondingly produced 7 µJ pulse energy and 260 ns pulse width at 2.074 µm. To the best of our knowledge, this is the first demonstration of a Q-switched fiber laser operating beyond 3 µm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nonlinear operation regimes of quantum-dot semiconductor optical amplifiers (QD-SOAs) are investigated and the ideal filter providing the best all-optical wavelength conversion efficiency is derived theoretically. Results are confirmed by experiments with Q2-factors amounting to 16 dB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiwavelength fiber laser is a perfect light source for future wavelength-division-multiplexing optical communication systems. A multiwavelength fiber laser based on nonlinear polarization rotation with up to 18 wavelengths has been proposed and demonstrated. The intensity- and wavelength-dependent loss induced by nonlinear polarization rotation effect is used to alleviate the mode competition in the homogeneous broadening gain medium of erbium-doped fiber. Instead of traditional filters, a polarization-maintaining fiber is inserted into the laser cavity, with which the polarization-dependent isolator composes an equivalent Lyot birefringent fiber filter. The in-line birefringence fiber filter is used to simplify the laser configuration, which benefits systematic integration. The effect of the 980 nm pump power on the multiwavelength generation is investigated. It is shown that the pump power contributes a lot to the evenness of the multiwavelength spectra due to the intensity dependence of nonlinear polarization rotation effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using three fibre gratings with excessively tilted structures in the cavity, we have experimentally demonstrated a multiwavelength switchable erbium-doped fibre ring laser system. The three tilted gratings act as in-fibre polariser and polarisation dependent loss filters to induce the polarisation hole burning effect in the cavity for the operation of the laser at single, double, triple and quadruple wavelengths. The laser system has demonstrated good stability under room temperature conditions and also achieved a high degree of polarization (~30dB), high optical signal to noise ratio (up to 63dB) and high side mode suppression (~50dB). The system has also been investigated for temperature and strain sensing by subjecting the seeding fibre Bragg gratings (FBG) to temperature and strain variations. Since the loss band of the polarisation dependent loss filter is broader than the bandwidth of the seeding FBG, the laser output shifts in wavelength with the applied temperature and strain. The fibre ring laser has shown good responses to the temperature and strain, providing sensitivities of approximately 11.7 pm/°C and 0.85pm/µe respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Applying direct error counting, we assess the performance of 20 Gbit/s wavelength-division multiplexing return-to-zero differential phase-shift keying (RZ-DPSK) transmission at 0.4 bit/(s Hz) spectral efficiency for application on installed non-zero dispersion-shifted fibre based transoceanic submarine systems. The impact of the pulse duty cycle on the system performance is investigated and the reliability of the existing theoretical approaches to the BER estimation for the RZ-DPSK format is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A tunable multiwavelength fiber laser with ultra-narrow wavelength spacing and large wavelength number using a semiconductor optical amplifier (SOA) has been demonstrated. Intensity-dependent transmission induced by nonlinear polarization rotation in the SOA accounts for stable multiwavelength operation with wavelength spacing less than the homogenous broadening linewidth of the SOA. Stable multiwavelength lasing with wavelength spacing as small as 0.08 nm and wavelength number up to 126 is achieved at room temperature. Moreover, wavelength tuning of 20.2 nm is implemented via polarization tuning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and cost-effective technique for generating a flat, square-shaped multi-wavelength optical comb with 42.6 GHz line spacing and over 0.5 THz of total bandwidth is presented. A detailed theoretical analysis is presented, showing that using two concatenated modulators driven with voltages of 3.5 Vp are necessary to generate 11 comb lines with a flatness below 2dB. This performance is experimentally demonstrated using two cascaded Versawave 40 Gbit/s low drive voltage electro-optic polarisation modulators, where an 11 channel optical comb with a flatness of 1.9 dB and a side-mode-suppression ratio (SMSR) of 12.6 dB was obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a self-reference multiplexed fibre interferometer (MFI) by using a tunable laser and fibre Bragg grating (FBG). The optical measurement system multiplexes two Michelson fibre interferometers with shared optical path in the main part of optical system. One fibre optic interferometer is used as a reference interferometer to monitor and control the high accuracy of the measurement system under environmental perturbations. The other is used as a measurement interferometer to obtain information from the target. An active phase tracking homodyne (APTH) technique is applied for signal processing to achieve high resolution. MFI can be utilised for high precision absolute displacement measurement with different combination of wavelengths from the tuneable laser. By means of Wavelength-Division-Multiplexing (WDM) technique, MFI is also capable of realising on-line surface measurement, in which traditional stylus scanning is replaced by spatial light-wave scanning so as to greatly improve the measurement speed and robustness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of orthogonal frequency-division multiplexing (OFDM) in an optical burst-switched system employing a single fast switching sample grating-distributed Bragg reflector (SG-DBR) laser is demonstrated experimentally. The effect of filter profiles compatible with 50, 25, and 12.5 GHz wavelength-division multiplexing grids on the system is investigated with system performance examined in terms of error vector magnitude per subcarrier for OFDM burst data beginning at various times after a switching event. Additionally the placement of the OFDM training sequence within the data burst and its effect on the system is investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors study experimentally ~10 ps return-to-zero pulse propagation near the net dispersion zero of an optical fibre transmission line. Stable near-jitter-free propagation was observed over 70 Mm. Pulse stabilisation and ASE suppression were achieved through the saturable aborber mechanism of nonlinear polarisation rotation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a novel dual-wavelength erbium-fiber laser that uses a single nonlinear-optical loop mirror modulator to simultaneously modelock two cavities with chirped fiber Bragg gratings as end mirrors. We show that this configuration produces synchronized soliton pulse trains with an ultra-low RMS inter-pulse-stream timing jitter of 620 fs enabling application to multiwavelength systems at data rates in excess of 130 Gb/s. © 1995 IEEE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel wavelength-division-multiplexed in-fibre Bragg grating sensor system combined with high resolution drift-compensated interferometric wavelength-shift detection is described. This crosstalk-free system is based on the use of an interferometric wavelength scanner and a low resolution spectrometer. A four element system is demonstrated for temperature measurement, and a resolution of ±0.1°C has been achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe an all-fibre, passive scheme for making extended range interferometric measurements based on the dual wavelength technique. The coherence tuned interferometer network is illuminated with a single superfluorescent fibre source at 1.55 μm and the two wavelengths are synthesised at the output by means of chirped fibre Bragg gratings. We demonstrate an unambiguous sensing range of 270 μm, with a dynamic range of 2.7 × 105.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel quasidistributed in-flber Bragg grating (FBG) temperature sensor system has been developed for temperature profiling in vivo in the human body for medical applications, e.g., hyperthermia treatment. This paper provides the operating principle of FBG temperature sensors and then the design of the sensor head. High-resolution detection of the wavelength-shifts induced by temperature changes are achieved using drift-compensated interferometric detection while the return signals from the FBG sensor array are demultiplexed with a simple monochromator which offers crosstalk-free wavelength-division-multiplexing (WDM). A "strain-free" probe is designed by enclosing the FBG sensor array in a protection sleeve. A four FBG sensor system is demonstrated and the experimental results are in good agreement with those obtained by traditional electrical thermocouple sensors. A resolution of 0.1°C and an accuracy of ±0.2°C over a temperature range of 30-60°C have been achieved, which meet established medical requirements.