315 resultados para long-period fiber gratings
Resumo:
The use of high intensity femtosecond laser sources for inscribing fibre gratings has attained significant interest. The principal advantage of high-energy pulses is their ability for grating inscription in any material type without preprocessing or special core doping. In the field of fibre optical sensing LPGs written in photonic crystal fibre have a distinct advantage of low temperature sensitivity over gratings written in conventional fibre and thus minimal temperature cross-sensitivity. Previous studies have indicated that LPGs written by a point-by-point inscription scheme using a low repetition femtosecond laser exhibit post-fabrication evolution leading to temporal instabilities at room temperatures with respect to spectral location, strength and birefringence of the attenuation bands. These spectral instabilities of LPGs are studied in photonic crystal fibres (endlessly single mode microstructure fibre) to moderately high temperatures 100°C to 200°C and their performance compared to fusion-arc fabricated LPG. Initial results suggest that the fusion-arc fabricated LPG demonstrate less spectral instability for a given constant and moderate temperature, and are similar to the results obtained when inscribed in a standard single mode fibre.
Resumo:
A set of long period grating devices have been fabricated in photosensitive single mode fibre coated with a series of copper rings (period of 380μm, 50% duty cycle and length of 4cm). The long period gratings were inscribed with a uniform UV-laser exposure across the entire length of the copper ring patterned coating. The devices ranged in copper thickness from 0.5μm to 1.5μm. In addition, a control long period grating was fabricated in the same type of fibre with the same period for comparison. The refractive index and temperature spectral sensitivity of these devices were investigated and it was found that the index and temperature sensitivity is a function of the thickness of the copper rings, as supported by theoretical modelling. Furthermore, the index sensitivity of these devices in the 1.333 index region is greater than the control long period grating. The patterned 0.5μm coated long period grating gave a sensitivity of Δλ/Δn = -74 nm leading to a resolution of 1.4×10-3 compared to the control which had a sensitivity of Δλ/Δn = -32 nm with a resolution of 3.2×10-3 in the index region of 1.320 to 1.380 (aqueous solution regime). This demonstrates a two fold increase in the sensitivity. This novel fibre long period grating device shows potential for increasing the resolution of measurements of the index of aqueous solutions.
Resumo:
The curvature- or bend-sensing response of long-period gratings (LPG) UV-inscribed in D-shaped fiber has been investigated experimentally. Strong fiber orientation dependence of the spectral response when such LPGs are subjected to dynamic bending has been observed and is shown to form the basis for new vector sensors.
Resumo:
We report the implementation of vector bending sensors using long-period gratings (LPGs) UV-inscribed in flat-clad, four-core and D-shaped fibres. Our experiments reveal a strong fibre-orientation dependence of the spectral response when such LPGs are subjected to dynamic bending, which provided an opportunity to realize curvature measurement with direction recognition.
Resumo:
In order to characterise long period gratings fabricated in endlessly single mode photonic crystal fibres with bulk cladding we perform eigenanalysis of guided modes supported by these fibres. Resonant coupling occurs only when the beating length equals the multiple grating periods. Experimentally obtained grating spectra and sensitivity are fully explained using modified phase matching condition. © Springer 2006.
Resumo:
Long period gratings (LPGs) were written into a D-shaped optical fibre that has an elliptical core with a W-shaped refractive index profile and the first detailed investigation of such LPGs is presented. The LPGs’ attenuation bands were found to be sensitive to the polarisation of the interrogating light with a spectral separation of about 15 nm between the two orthogonal polarisation states. A finite element method was successfully used to model many of the behavioural features of the LPGs. In addition, two spectrally overlapping attenuation bands corresponding to orthogonal polarisation states were observed; modelling successfully reproduced this spectral feature. The spectral sensitivity of both orthogonal states was experimentally measured with respect to temperature and bending. These LPG devices produced blue and red wavelength shifts depending upon the orientation of the bend with measured maximum sensitivities of -3.56 and +6.51 nm m, suggesting that this type of fibre LPG may be useful as a shape/bend orientation sensor with reduced errors associated with polarisation dependence. The use of neighbouring bands to discriminate between temperature and bending was also demonstrated, leading to an overall curvature error of ±0.14 m-1 and an overall temperature error of ±0.3 °C with a maximum polarisation dependence error of ±8 × 10-2 m-1 for curvature and ±5 × 10-2 °C for temperature.
Resumo:
A numerical model of a long period grating in photonic crystal fibre fabricated by an electric arc is proposed that allows for the spectral characterisation of the grating. In the combination with the suggested model of the photonic crystal and the experimentally recorded grating growth it is used to find the index change induced by the electric arc. © Springer Science+Business Media B.V. 2007.
Resumo:
A new fibre Mach-Zehnder type based on a single LPG written in a biconical fibre taper is presented alongside a theoretical model supporting the observed effect
Resumo:
Long period gratings in two types of photonic crystal fibre have been studied. The gratings display negligible temperature sensitivity but useful sensitivity to other measurands. Theoretical modelling suggests that unusual phase matching conditions apply.
Resumo:
A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso showing reasonable agreement with a spirometer used simultaneously to record the volume at the mouth during breathing. The curvature sensors are based upon long period gratings written in a progressive three layered fibre that are insensitive to refractive index changes. The sensor platform consists of the long period grating laid upon a carbon fibre ribbon, which is encapsulated in a low temperature curing silicone rubber. An array of sensors is also used to reconstruct the shape changes of a resuscitation manikin during simulated respiration. The data for reconstruction is obtained by two methods of multiplexing and interrogation: firstly using the transmission spectral profile of the LPG's attenuation bands measured using an optical spectrum analyser; secondly using a derivative spectroscopy technique.
Resumo:
In this paper, sensing characteristics of long period gratings in three different types of single mode optical fibre: a step-index fibre, a progressive three layered fibre and a suppressed-cladding fibre were investigated. It was found that variation in the refractive index profile and material constants of the fibre can produce a dramatic change in the spectral sensitivity for a particular measurand for a given long period grating attenuation band. © 2003 IEEE.
Resumo:
Cardiovascular health of the human population is a major concern for medical clinicians, with cardiovascular diseases responsible for 48% of all deaths worldwide, according to the World Health Organisation. Therefore the development of new practicable and economical diagnostic tools to scrutinise the cardiovascular health of humans is a major driver for clinicians. We offer a new technique to obtain seismocardiographic signals covering both ballistocardiography (below 20Hz) and audible heart sounds (20Hz upwards). The detection scheme is based upon an array of curvature/displacement sensors using fibre optic long period gratings interrogated using a variation of the derivative spectroscopy interrogation technique. © 2014 SPIE.