90 resultados para Ship based meteorological sensor


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simple, low cost and fast response time intrinsic relative humidity sensor system based on an etched singlemode polymer fiber Bragg (POFBG) is presented in this paper. A macro-bend linear edge filter which converts the humidity induced wavelength shift into an intensity change is used as the interrogation technique. The singlemode POFBG is etched to micro-meters in diameter to improve the response time of the humidity sensor. A response time of 4.5 s is observed for a polymer FBG with a cladding diameter of 25 μm. The overall sensor system sensitivity was 0.23 mV/%RH. The etched POFBG humidity sensor shows anexponential decrease in response time with a decrease in fiber diameter. The developed sensor might have potential applications in a wide range of applications where fast and accurate real time humidity control is required. © 2013 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In-Motes is a mobile agent middleware that generates an intelligent framework for deploying applications in Wireless Sensor Networks (WSNs). In-Motes is based on the injection of mobile agents into the network that can migrate or clone following specific rules and performing application specific tasks. By doing so, each mote is given a certain degree of perception, cognition and control, forming the basis for its intelligence. Our middleware incorporates technologies such as Linda-like tuplespaces and federated system architecture in order to obtain a high degree of collaboration and coordination for the agent society. A set of behavioral rules inspired by a community of bacterial strains is also generated as the means for robustness of the WSN. In this paper, we present In-Motes and provide a detailed evaluation of its implementation for MICA2 motes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Results are reported from recent research on the use of the Brillouin gain/loss mechanism for distributed sensing. A theoretical model of the interaction of the pulsed and CW beams is described and compared with experiments. Results from a system with a 51 km sensing length are presented. We finally investigate issues related to the variation within the sensing fiber of the polarizations of the two beams.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel all-fibre cavity ring down spectroscopy technique is demonstrated where a tilted fibre Bragg grating in the cavity provides sensitivity to surrounding refractive index. A decay time of 450ns was attained when sensing water.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Energy consumption has been a key concern of data gathering in wireless sensor networks. Previous research works show that modulation scaling is an efficient technique to reduce energy consumption. However, such technique will also impact on both packet delivery latency and packet loss, therefore, may result in adverse effects on the qualities of applications. In this paper, we study the problem of modulation scaling and energy-optimization. A mathematical model is proposed to analyze the impact of modulation scaling on the overall energy consumption, end-to-end mean delivery latency and mean packet loss rate. A centralized optimal management mechanism is developed based on the model, which adaptively adjusts the modulation levels to minimize energy consumption while ensuring the QoS for data gathering. Experimental results show that the management mechanism saves significant energy in all the investigated scenarios. Some valuable results are also observed in the experiments. © 2004 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have investigated numerically and experimentally a fiber Bragg grating (FBG) sensor interrogation scheme utilizing a linear chirped grating-based Sagnac loop as a wavelength-dependent receiver. The scheme is suitable for both static and dynamic sensor interrogation with advantages of stable and linear readout response and easily-adjustable sensing resolution and dynamic range. Static and dynamic strain resolutions as high as ± 4.2 με and 0.406 με/√ Hz have been demonstrated using this scheme.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have experimentally demonstrated an active loading sensor system based on a fiber ring laser with single-polarization output using an intra-cavity 45°-tilted fiber grating (45°-TFG). When the laser cavity fiber subjected to loading, the laser output is encoded with the load and can be measured and monitored by a power metre. A loading sensitivity as high as 0.033/ (kg·m-1) has been achieved using this laser. The experiment results clearly show that single polarization fiber laser may be developed to a low-cost high-sensitivity loading sensor system. © 2014 SPIE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cardiovascular health of the human population is a major concern for medical clinicians, with cardiovascular diseases responsible for 48% of all deaths worldwide, according to the World Health Organisation. Therefore the development of new practicable and economical diagnostic tools to scrutinise the cardiovascular health of humans is a major driver for clinicians. We offer a new technique to obtain seismocardiographic signals covering both ballistocardiography (below 20Hz) and audible heart sounds (20Hz upwards). The detection scheme is based upon an array of curvature/displacement sensors using fibre optic long period gratings interrogated using a variation of the derivative spectroscopy interrogation technique. © 2014 SPIE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We propose and demonstrate an optical liquid level sensor based on the surrounding medium refractive index (SRI) sensing using an excessively tilted fibre grating (ETFG). When the ETFG submerged in water, two sets of cladding modes are coupled, corresponding to air- and water-surrounded grating structures, respectively. The coupling strengths of the two sets of cladding modes evolve with the submerging length of the grating, providing a mechanism to measure the liquid level. Comparing with long-period fibre grating based liquid level sensor, the ETFG sensor has a much higher SRI responsivity for liquids with refractive index around 1.33 and a lower thermal cross sensitivity. © 2013 Published by Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An optical in-fiber modal interferometer-based volume strain sensor for earthquake prediction is proposed and experimentally demonstrated. The sensing element is formed by wrapping a multimode-singlemode-multimode fiber structure onto a polyurethane hollow column. Due to the modal interference between the excited guided modes in the fiber, strong interference pattern could be observed in the transmission spectrum. Theoretical analysis verifies that the resonant wavelength shifts as a result of the volume strain variation caused by the column deformation with square root relationship. Sensitivity > 3.93 pm/με within the volume strain ranging from 0 to 1300 με is also experimentally demonstrated. By taking the response of bidirectional change of volume strain and the sluggish character of the employed sensing material into consideration, the sensing system presents good repeatability and stability. © 2001-2012 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We experimentally demonstrated a highly sensitive twist sensor system based on a 45° and an 81° tilted fibre grating (TFG). The 81°-TFG has a set of dual-peaks that are due to the birefringence induced by its extremely tilted structure. When the 81°-TFG subjected to twist, the coupling to the two peaks would interchange from each other, providing a mechanism to measure and monitor the twist. We have investigated the performance of the sensor system by three interrogation methods (spectral, power-measurement and voltage-measurement). The experimental results clearly show that the 81°-TFG and the 45°-TFG could be combined forming a full fibre twist sensor system capable of not just measuring the magnitude but also recognising the direction of the applied twist.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A dual-parameter optical sensor has been realized by UV-writing a long-period and a Bragg grating structure in D-fiber. The hybrid configuration permits the detection of the temperature from the latter and measuring the external refractive index from the former responses, respectively. The employment of the D-fiber allows as effective modification and enhancement of the device sensitivity by cladding etching. The grating sensor has been used to measure the concentrations of aqueous sugar solutions, demonstrating the potential capability to detect concentration changes as small as 0.01%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Hybrid WDM/TDM enabled microstructure based optical fiber sensor network with large capacity is proposed. Assisted by Fabry-Perot filter, the demodulation system with high speed of 500Hz and high wavelength resolution less than 4.91pm is realized. © OSA 2015.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report a highly sensitive refractive index (RI) sensor in the aqueous solution, which is based on an 81°-tilted fiber grating structure inscribed into a thin cladding fiber with 40 μm cladding radius. The numerical analysis has indicated that the RI sensitivity of cladding resonance mode of the grating can be significantly enhanced with reducing cladding size. This has been proved by the experimental results as the RI sensitivities of TM and TE resonance peaks in the index region of 1.345 have been increased to 1180 nm/RIU and 1150 nm/RIU, respectively, from only 200 and 170 nm/RIU for the same grating structure inscribed in standard telecom fiber with 62.5-μm cladding radius. Although the temperature sensitivity has also increased, the change in temperature sensitivity is still insignificant in comparison with RI sensitivity enhancement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A high sensitivity SRI sensor was fabricated by inscribing an ex-TFG in a thin cladding fiber, achieving enhanced SRI sensitivities of the TM and TE resonance peaks around 1180nm/RIU and 1150nm/RIU at the index of 1.345. © 2014 OSA.