71 resultados para laryngeal mask


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Single- and multi-core passive and active germanate and tellurite glass fibers represent a new class of fiber host for in-fiber photonics devices and applications in mid-IR wavelength range, which are in increasing demand. Fiber Bragg grating (FBG) structures have been proven as one of the most functional in-fiber devices and have been mass-produced in silicate fibers by UV-inscription for almost countless laser and sensor applications. However, because of the strong UV absorption in germanate and tellurite fibers, FBG structures cannot be produced by UVinscription. In recent years femtosecond (fs) lasers have been developed for laser machining and microstructuring in a variety of glass fibers and planar substrates. A number of papers have been reported on fabrication of FBGs and long-period gratings in optical fibers and also on the photosensitivity mechanism using 800nm fs lasers. In this paper, we demonstrate for the first time the fabrication of FBG structures created in passive and active single- and three-core germanate and tellurite glass fibers by using 800nm fs-inscription and phase mask technique. With a fs peak power intensity in the order of 1011W/cm2, the FBG spectra with 2nd and 3rd order resonances at 1540nm and 1033nm in a single-core germanate glass fiber and 2nd order resonances between ~1694nm and ~1677nm with strengths up to 14dB in all three cores of three-core passive and active tellurite fibers were observed. Thermal and strain properties of the FBGs made in these mid-IR glass fibers were characterized, showing an average temperature responsivity of ~20pm/°C and a strain sensitivity of 1.219±0.003pm/µe.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have UV-inscribed and theoretically and experimentally analyzed fiber gratings with the structure tilted at 45° and implemented this type of devices as an in-fiber polarizer. A systematic investigation has been carried out on the characterization of 45° tilted fiber gratings (45° TFGs) in terms of the polarization-dependant loss (PDL) and thermal response. The detailed theoretical modeling has revealed a linear correlation between the grating length and the PDL, which has been proved by the experimental results. For the first time, we have examined the UV beam diffraction from a tilted phase mask and designed the UV-inscription system to suit the 45° TFG fabrication. Experimentally, a 24 mm long 45° TFG UV-inscribed in standard telecom single-mode fiber exhibited around 25 dB PDL at 1530 nm and an over ~300 nm bandwidth of PDL spectrum. By the concatenation method, a 44 mm long grating showed a PDL as high as 40 dB that is close to the high polarization extinction ratio of commercial products. Moreover, we have revealed that the PDL of 45° TFGs has low thermal influence, which is desirable for real application devices. Finally, we experimentally demonstrated an all-fiber twist sensor system based on a 45° and an 81° TFG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Related Party Transactions (RPTs) have been considered recently in research as a phenomenon which is associated with several financial scandals, shareholder’s wealth expropriation and is used for earnings management (EM) purposes by the reporting entity. This study aimed to: (i) assess the extent of EM and RPTs i Greece; (ii) investigate the association between RPTs and EM; (iii) investigate the association between corporate governance and EM; (iv) investigate the association between corporate governance and RPTs; and (v) investigate the impact of RPTs on Accounting Quality. Greece was selected for this study as it provides a special context due to poor investor protection, high levels of EM and unhealthy financial reporting environment where wealth extraction and EM are more likely. This study examines the relationship between earnings management and RPTs for the firms listed on the Athens Stock Exchange (ASE). Moreover, it examines the association between earnings management and corporate governance activities. The results show a negative and significant relationship between EM and RPTs. This finding does not support the conclusion that RPTs are necessarily conducted to mask fraud or the extraction of firm resources. The results show that firms audited by one of the Big 4 audit firms are associated with less EM. Additionally, the study investigates the relationship between RPTs and accounting quality. The findings show that that there is no significant difference in accounting quality between RPTs firms and non-RPTs firms. This study contributes to the EM, accounting quality and corporate governance literatures. This research suggests recommendations for researchers, data providers and policy makers on ways to reduce the problems associated with RPTs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Step-index polymer optical fiber Bragg gratings (POFBGs) and microstructured polymer optical fiber Bragg gratings (mPOFBGs) present several attractive features, especially for sensing purposes. In comparison to FBGs written in silica fibers, they are more sensitive to temperature and pressure because of the larger thermo-optic coefficient and smaller Young's modulus of polymer materials. (M)POFBGs are most often photowritten in poly(methylmethacrylate) (PMMA) materials using a continuous-wave 325 nm HeCd laser. For the first time to the best of our knowledge, we study photoinduced birefringence effects in (m)POFBGs. To achieve this, highly reflective gratings were inscribed with the phase mask technique. They were then monitored in transmission with polarized light. For this, (m)POF sections a few cm in length containing the gratings were glued to angled silica fibers. Polarization dependent loss (PDL) and differential group delay (DGD) were computed from the Jones matrix eigenanalysis using an optical vector analyser. Maximum values exceeding several dB and a few picoseconds were obtained for the PDL and DGD, respectively. The response to lateral force was finally investigated. As it induces birefringence in addition to the photo-induced one, an increase of the PDL and DGD values were noticed. © 2014 Copyright SPIE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new generation of surface plasmonic optical fibre sensors is fabricated using multiple coatings deposited on a lapped section of a single mode fibre. Post-deposition UV laser irradiation using a phase mask produces a nano-scaled surface relief grating structure, resembling nano-wires. The overall length of the individual corrugations is approximately 14 μm with an average full width half maximum of 100 nm. Evidence is presented to show that these surface structures result from material compaction created by the silicon dioxide and germanium layers in the multi-layered coating and the surface topology is capable of supporting localised surface plasmons. The coating compaction induces a strain gradient into the D-shaped optical fibre that generates an asymmetric periodic refractive index profile which enhances the coupling of the light from the core of the fibre to plasmons on the surface of the coating. Experimental data are presented that show changes in spectral characteristics after UV processing and that the performance of the sensors increases from that of their pre-UV irradiation state. The enhanced performance is illustrated with regards to change in external refractive index and demonstrates high spectral sensitivities in gaseous and aqueous index regimes ranging up to 4000 nm/RIU for wavelength and 800 dB/RIU for intensity. The devices generate surface plasmons over a very large wavelength range, (visible to 2 μm) depending on the polarization state of the illuminating light. © 2013 SPIE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In non-invasive ventilation, continuous monitoring of respiratory volumes is essential. Here, we present a method for the measurement of respiratory volumes by a single fiber-grating sensor of bending and provide the proof-of-principle by applying a calibration-test measurement procedure on a set of 18 healthy volunteers. Results establish a linear correlation between a change in lung volume and the corresponding change in a local thorax curvature. They also show good sensor accuracy in measurements of tidal and minute respiratory volumes for different types of breathing. The proposed technique does not rely on the air flow through an oronasal mask or the observation of chest movement by a clinician, which distinguishes it from the current clinical practice. © 2014 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Novel surface plasmonic optical fiber sensors have been fabricated using multiple coatings deposited on a lapped section of a single mode fiber. UV laser irradiation processing with a phase mask produces a nano-scaled surface relief grating structure resembling nano-wires. The resulting individual corrugations produced by material compaction are approximately 20 μm long with an average width at half maximum of 100 nm and generate localized surface plasmons. Experimental data are presented that show changes in the spectral characteristics after UV processing, coupled with an overall increase in the sensitivity of the devices to surrounding refractive index. Evidence is presented that there is an optimum UV dosage (48 joules) over which no significant additional optical change is observed. The devices are characterized with regards to change in refractive index, where significantly high spectral sensitivities in the aqueous index regime are found, ranging up to 4000 nm/RIU for wavelength and 800 dB/RIU for intensity. © 2013 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the nature of resource limitations during visual target processing by imposing high temporal processing demands on the cognitive system. This was achieved by embedding target stimuli into rapid-serial-visual-presentation-streams (RSVP). In RSVP streams, it is difficult to report the second of two targets (T2) if the second follows the first (T1) within 500 ms. This effect is known as the attentional blink (AB). For the AB to occur, it is essential that T1 is followed by a mask, as without such a stimulus, the AB is significantly attenuated. Usually, it is thought that T1 processing is delayed by the mask, which in turn delays T2 processing, increasing the likelihood for T2 failures (AB). Predictions regarding amplitudes and latencies of cortical responses (M300, the magnetic counterpart to the P300) to targets were tested by investigating the neurophysiological effects of the post-T1 item (mask) by means of magnetoencephalography (MEG). Cortical M300 responses to targets drawn from prefrontal sources – areas associated with working memory – revealed accelerated T1 yet delayed T2 processing with an intervening mask. The explanation we are proposing assumes that “protection” of ongoing T1 processing necessitated by the occurrence of the mask suppresses other activation patterns, which boosts T1 yet also hinders further processing. Our data shed light on the mechanisms employed by the human brain for ensuring visual target processing under high temporal processing demands, which is hypothesized to occur at the expense of subsequently presented information.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fabrication of gratings has gone a long way since the onset by Kenneth Hill in 1976. Basic fabrication techniques such as holographic and phase-mask which have distinguishing advantages (variable wavelength, and high repeatability consecutively) have since been modified in an effort to combine the advantages of both methods. These basic methods are inherently simple and have few controls, they have been combined and modified over time to enable the possibility of fabricating gratings with complex modulation index and phase profiles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fabrication of gratings has gone a long way since the onset by Kenneth Hill in 1976. Basic fabrication techniques such as holographic and phase-mask which have distinguishing advantages (variable wavelength, and high repeatability consecutively) have since been modified in an effort to combine the advantages of both methods. These basic methods are inherently simple and have few controls, they have been combined and modified over time to enable the possibility of fabricating gratings with complex modulation index and phase profiles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on high power issues related to the reliability of fibre Bragg gratings inscribed with an infrared femtosecond laser using the point-by-point writing method. Conventionally, fibre Bragg gratings have usually been written in fibres using ultraviolet light, either holographically or using a phase mask. Since the coating is highly absorbing in the UV, this process normally requires that the protective polymer coating is stripped prior to inscription, with the fibre then being recoated. This results in a time consuming fabrication process that, unless great care is taken, can lead to fibre strength degradation, due to the presence of surface damage. The recent development of FBG inscription using NIR femtosecond lasers has eliminated the requirement for the stripping of the coating. At the same time the ability to write gratings point-by-point offers the potential for great flexibility in the grating design. There is, however, a requirement for reliability testing of these gratings, particularly for use in telecommunications systems where high powers are increasingly being used in long-haul transmission systems making use of Raman amplification. We report on a study of such gratings which has revealed the presence of broad spectrum power losses. When high powers are used, even at wavelengths far removed from the Bragg condition, these losses produce an increase in the fibre temperature due to absorption in the coating. We have monitored this temperature rise using the wavelength shift in the grating itself. At power levels of a few watts, various temperature increases were experienced ranging from a few degrees up to the point where the buffer completely melts off the fibre at the grating site. Further investigations are currently under way to study the optical loss mechanisms in order to optimise the inscription mechanism and minimise such losses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present femtosecond laser inscribed phase masks for the inscription of Bragg gratings in optical fibres. The principal advantage is the flexibility afforded by the femtosecond laser inscription, where sub-surface structures define the phase mask period and mask properties. The masks are used to produce fibre Bragg gratings having different orders according to the phase mask period. The work demonstrates the incredible flexibility of femtosecond lasers for the rapid prototyping of complex and reproducible mask structures. We also consider three-beam interference effects, a consequence of the zeroth-order component present in addition to higher-order diffraction components. © 2012 SPIE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oral liquid formulations are ideal dosage forms for paediatric, geriatric and patient with dysphagia. Dysphagia is prominent among patients suffering from stroke, motor neurone disease, advanced Alzheimer’s and Parkinson’s disease. However oral liquid preparations are particularly difficult to formulate for hydrophobic and unstable drugs. Therefore current methods employed in solving this issue include the use of ‘specials’ or extemporaneous preparations. In order to challenge this, the government has encouraged research into the field of oral liquid formulations, with the EMEA and MHRA publishing list of drugs of interest. The current work investigates strategic formulation development and characterisation of select API’s (captopril, gliclazide, melatonin, L-arginine and lansoprazole), each with unique obstacles to overcome during solubilisation, stabilisation and when developing a palatable dosage from. By preparing a validated calibration protocol for each of the drug candidates, the oral liquid formulations were assessed for stability, according to the ICH guidelines along with thorough physiochemical characterisation. The results showed that pH and polarity of the solvent had the greatest influence on the extent of drug solubilisation, with inclusion of antioxidants and molecular steric hindrance influencing the extent of drug stability. Captopril, a hydrophilic ACE inhibitor (160 mg.mL-1), undergoes dimerisation with another captopril molecule. It was found that with the addition of EDTA and HP-β-CD, the drug molecule was stabilised and prevented from initiating a thiol induced first order free radical oxidation. The cyclodextrin provided further steric hindrance (1:1 molar ratio) resulting in complete reduction of the intensity of sulphur like smell associated with captopril. Palatability is a crucial factor in patient compliance, particularly when developing a dosage form targeted towards paediatrics. L-arginine is extremely bitter in solution (148.7 g.L-1). The addition of tartaric acid into the 100 mg.mL-1 formulation was sufficient to mask the bitterness associated with its guanidium ions. The hydrophobicity of gliclazide (55 mg.L-1) was strategically challenged using a binary system of a co-solvent and surfactant to reduce the polarity of the medium and ultimately increase the solubility of the drug. A second simpler method was developed using pH modification with L-arginine. Melatonin has two major obstacles in formulation: solubility (100 μg.mL-1) and photosensitivity, which were both overcome by lowering the dielectric constant of the medium and by reversibly binding the drug within the cyclodextrin cup (1:1 ratio). The cyclodextrin acts by preventing UV rays from reaching the drug molecule and initiated the degradation pathway. Lansoprazole is an acid labile drug that could only be delivered orally via a delivery vehicle. In oral liquid preparations this involved nanoparticulate vesicles. The extent of drug loading was found to be influenced by the type of polymer, concentration of polymer, and the molecular weight. All of the formulations achieved relatively long shelf-lives with good preservative efficacy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sustained fixation of a bright coloured stimulus will, on extinction of the stimulus and continued steady fixation, induce an afterimage whose colour is complementary to that of the initial stimulus; an effect thought to be caused by fatigue of cones and/or of cone-opponent processes to different colours. However, to date, very little is known about the specific pathway that causes the coloured afterimage. Using isoluminant coloured stimuli recent studies have shown that pupil constriction is induced by onset and offset of the stimulus, the latter being attributed specifically to the subsequent emergence of the coloured afterimage. The aim of the study was to investigate how the offset pupillary constriction is generated in terms of input signals from discrete functional elements of the magno- and/or parvo-cellular pathways, which are known principally to convey, respectively, luminance and colour signals. Changes in pupil size were monitored continuously by digital analysis of an infra-red image of the pupil while observers viewed isoluminant green pulsed, ramped or luminance masked stimuli presented on a computer monitor. It was found that the amplitude of the offset pupillary constriction decreases when a pulsed stimulus is replaced by a temporally ramped stimulus and is eliminated by a luminance mask. These findings indicate for the first time that pupillary constriction associated with a coloured afterimage is mediated by the magno-cellular pathway. © 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on the effective side detection of radiation-mode out-coupling from blazed fiber Bragg gratings (BFBGs) fabricated in single-mode fiber (SMF) and multimode fiber (MMF). The far-field radiation power distribution from BFBGs have been measured achieving a high spatial-spectral resolution (0.17 mm/nm). We have also investigated comparatively the transmission-loss characteristics of BFBGs in both fiber types, fabricated using phase-mask and holographic inscription techniques. Our results reveal clearly that the radiation out-coupling from BFBGs is significantly stronger and spectrally more confined in MMF than in SMF.