49 resultados para hydrogel nanocomposites
Resumo:
Purpose: Most published surface wettability data are based on hydrated materials and are dominated by the air-water interface. Water soluble species with hydrophobic domains (such as surfactants) interact directly with the hydrophobic domains in the lens polymer. Characterisation of relative polar and non-polar fractions of the dehydrated material provides an additional approach to surface analysis. Method: Probe liquids (water and diiodomethane) were used to characterise polar and dispersive components of surface energies of dehydrated lenses using the method of Owens and Wendt. A range of conventional and silicone hydrogel soft lenses was studied. The polar fraction (i.e. polar/total) of surface energy was used as a basis for the study of the structural effects that influence surfactant persistence on the lens surface. Results: When plotted against water content of the hydrated lens, polar fraction of surface energy (PFSE) values of the dehydrated lenses fell into two rectilinear bands. One of these bands covered PFSE values ranging from 0.4 to 0.8 and contained only conventional hydrogels, with two notable additions: the plasma coated silicone hydrogels lotrafilcon A and B. The second band covered PFSE values ranging from 0.04 to 0.28 and contained only silicone hydrogels. Significantly, the silicone hydrogel lenses with lowest PFSE values (p<0.15) are found to be prone to lipid deposition duringwear. Additionally, more hydrophobic surfactants were found to be more persistent on lenses with lower PFSE values. Conclusions: Measurement of polar fraction of surface energy provides an importantmechanistic insight into surface interactions of silicone hydrogels.
Resumo:
This thesis is concerned with demonstrating how the visual representation of the sequence distribution of individual monomer units, of a polymer, that would be observed upon polymerisation, may be utilised in designing and synthesizing polymers with relatively low cell adhesion characteristics, The initial part of this thesis is concerned with demonstrating the use of a computer simulation technique, in illustrating the sequence distribution that would be observed upon the polymerisation of a set of monomers. The power of the computer simulation technique has been demonstrated through the simulation of the sequence distributions of some generic contact lens materials. These generic contact lens materials were chosen simply because in the field of biomaterials their compositions are amongst the most systematically regulated and they present a wide range of compositions. The validity of the computer simulation technique has been assessed through the synthesis and analysis of linear free-radical polymers at different conversions. Two main parameters were examined, that of composition and the number-average sequence lengths of individual monomer units, at various conversions. The polymers were synthesized through the solution polymerisation process. The monomer composition was determined by elemental analysis and 13C nuclear magnetic analysis (NMR). Number-average sequence lengths were determined exclusively through 13C NMR. Although the computer simulation technique provides a visual representation of the monomer sequence distribution up to 100% conversion, these assessments were made on linear polymers at a reasonably high conversion (above 50%) but below 100% conversion of ease for analysis. The analyses proved that the computer simulation technique was reasonably accurate in predicting the sequence distribution of monomer units, upon polymerisation, in the polymer.An approach has been presented which allows one to manipulate the use of monomers, with their reactivity ratios, thereby enabling us to design polymers with controlled sequence distributions.Hydrogel membranes, with relatively controlled sequence distributions and polymerised to 100% conversion, were synthesized to represent prospective biomaterials. Cell adhesion studies were used as a biological probe to investigate the susceptibility of the surface of these membranes to cell adhesion. This was necessary in order to assess the surface biocompatibility or biotolerance of these prospective biomaterials.
Resumo:
The objective of this thesis is to report the behaviour of mammalian cells with biocompatible synthetic polymers with potential for applications to the human body. Composite hydrogel materials were tested as possible keratoprosthetic devices. It was found that surface topography is an important consideration, pores, channels and fibres exposed on the surface of the hydrogels tested can have significant effects on the extent of cell adheson and proliferation. It is recommended that the core component is fabricated out of one of the following to provide a non cell adhesive base; A8, A11, A13, A22, A23. The haptic periphery fabricated out of one of the following would provide a cell adhesive composite; A16, A30, A33, A37, A38, A42, A43, A44. The presence of vitronectin in the ocular tissue appears to lead to higher cell adhesion to the posterior surface of a contact lens when compared to the anterior surface. Group IV contact lenses adhere more cells than Group II contact lenses - this may indicate that more protein (including vitronectin) is able to adhere to the contact lens due to the Group IV contact lenses high water content and ionic hydrogel matrix. Artificial lung surfactant analogues were found to be non cytotoxic but also decreased cell proliferation when tested at higher concentrations. Poly(lysine ethyl ester adipamide) [PLETESA] had the most favourable response on cell proliferation and commercial styrene/maleic anhydride (pMA/STY sp2) the most pronounced inhibitory response. The mode of action that decreases cell proliferation appears to be through membrane destabilization. Tissue culture well plates coated with PLETESA allowed cells to adhere in a concentration dependent manner, multilaminar liposomes possibly of PLETESA were observed in solution in PLETESA coated wells. Polyhydroxybutryate (PHB) and polyhydroxyvalerate (PHV) blends that contained hydroxyapatite were found to be the most cell adhesive material of those materials tested. The blends that were most susceptible to degradation adhered the most cells in initial stages of degradation. The initial slight increase in cell adhesion may be due to the increased rugosity of the material. As the degradation continued the number of cells adhering to the samples decreased, this may indicate that the polarity was inhibitory to cell adhesion during the later stages of degradation.
Resumo:
This study is concerned with the analysis of tear proteins, paying particular attention to the state of the tears (e.g. non-stimulated, reflex, closed), created during sampling, and to assess their interactions with hydrogel contact lenses. The work has involved the use of a variety of biochemical and immunological analytical techniques for the measurement of proteins, (a), in tears, (b), on the contact lens, and (c), in the eluate of extracted lenses. Although a diverse range of tear components may contribute to contact lens spoilation, proteins were of particular interest in this study because of their theoretical potential for producing immunological reactions. Although normal host proteins in their natural state are generally not treated as dangerous or non-self, those which undergo denaturation or suffer a conformational change may provoke an excessive and unnecessary immune response. A novel on-lens cell based assay has been developed and exploited in order to study the role of the ubiquitous cell adhesion glycoprotein, vitronectin, in tears and contact lens wear under various parameters. Vitronectin, whose levels are known to increase in the closed eye environment and shown here to increase during contact lens wear, is an important immunoregulatory protein and may be a prominent marker of inflammatory activity. Immunodiffusion assays were developed and optimised for use in tear analysis, and in a series of subsequent studies used for example in the measurement of albumin, lactoferrin, IgA and IgG. The immunodiffusion assays were then applied in the estimation of the closed eye environment; an environment which has been described as sustaining a state of sub-clinical inflammation. The role and presence of a lesser understood and investigated protein, kininogen, was also estimated, in particular, in relation to contact lens wear. Difficulties arise when attempting to extract proteins from the contact lens in order to examine the individual nature of the proteins involved. These problems were partly alleviated with the use of the on-lens cell assay and a UV spectrophotometry assay, which can analyse the lens surface and bulk respectively, the latter yielding only total protein values. Various lens extraction methods were investigated to remove protein from the lens and the most efficient was employed in the analysis of lens extracts. Counter immunoelectrophoresis, an immunodiffusion assay, was then applied to the analysis of albumin, lactoferrin, IgA and IgG in the resultant eluates.