113 resultados para Visual acuity.


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Carotenoids are not considered to be essential nutrients, but their antioxidant and photoprotective properties have prompted interest in their potential role in disease prevention. Our aim is to review the evidence In relation to ocular disease. Method: Web of Science and Medline via PubMed database search. Results Lutein and zeaxanthin intake has been associated with a 22% reduced risk of cataract extraction in women (RR 0.78, p = 0.04), and a 19% lower risk of cataract in men (RR 0.8, p = 0, 03). A randomised controlled trial (RCT) found a significant improvement in visual acuity in cataract patients supplemented with lutein. Two RCTs investigating the effect of P-carotene, in combination with other nutrients, on cataract report conflicting results. Several studies show no inverse association between cataract and P-carotene. Lutein and zeaxanthin are the only carotenoids found in the human macula. RCTs have found beneficial effects of both lutein and beta-carotene supplementation, in combination with other antioxidants, on visual function age-related macular disease affected subjects. Evidence for a role of lutein in preventing deterioration of visual function in retinitis pigmentosa patients is conflicting. CONCLUSIONS: Further research into the role of lutein and zeaxanthin in prevention of onset and progression of ocular disease is warranted.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to determine if there was an objective difference in reading between four commonly available lamps, of varying spectral radiance, for 13 subjects with age-related maculopathy (ARM) or non-exudative age-related macular degeneration (AMD) - logMAR visual acuity between 0.04 and 0.68. At a constant illuminance of 2000 lux, there was no interaction between ARM and AMD subgroups and no statistically significant difference between the lamps: standard (clear envelope) incandescent, daylight simulation (blue tint envelope) incandescent, compact fluorescent and halogen incandescent, for any reading outcome measure (threshold print size p = 0.67, critical print size p = 0.74, acuity reserve p = 0.84 and mean reading rate p = 0.78). For lamps typically used in low-vision rehabilitation, a clinically significant effect of spectral radiance on reading for people with ARM or non-exudative AMD is unlikely. © 2007 The College of Optometrists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To determine whether letter sequences and/or lens-presentation order should be randomized when measuring defocus curves and to assess the most appropriate criterion for calculating the subjective amplitude of accommodation (AoA) from defocus curves. SETTING: Eye Clinic, School of Life & Health Sciences, Aston University, Birmingham, United Kingdom. METHODS: Defocus curves (from +3.00 diopters [D] to -3.00 D in 0.50 D steps) for 6 possible combinations of randomized or nonrandomized letter sequences and/or lens-presentation order were measured in a random order in 20 presbyopic subjects. Subjective AoA was calculated from the defocus curves by curve fitting using various published criteria, and each was correlated to subjective push-up AoA. Objective AoA was measured for comparison of blur tolerance and pupil size. RESULTS: Randomization of lens-presentation order and/or letter sequences, or lack of, did not affect the measured defocus curves (P>.05, analysis of variance). The range of defocus that maintains highest achievable visual acuity (allowing for variability of repeated measurement) was better correlated to (r = 0.84) and agreed best with ( 0.50 D) subjective push-up AoA than any other relative or absolute acuity criterion used in previous studies. CONCLUSIONS: Nonrandomized letters and lens presentation on their own did not affect subjective AoA measured by defocus curves, although their combination should be avoided. Quantification of subjective AoA from defocus curves should be standardized to the range of defocus that maintains the best achievable visual acuity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To investigate the MacDQoL test-retest reliability and sensitivity to change in vision over a period of one year in a sample of patients with age-related macular degeneration (AMD). DESIGN: A prospective, observational study. METHOD: Patients with AMD from an ophthalmologist's list (n = 135) completed the MacDQoL questionnaire by telephone interview and underwent a vision assessment on two occasions, one year apart. RESULTS: Among participants whose vision was stable over one year (n = 87), MacDQoL scores at baseline and follow-up were highly correlated (r = 0.95; P < .0001). Twelve of the 22 scale items had intraclass correlations of >.80; only two were correlated <.7. There was no difference between baseline and follow-up scores (P = .85), indicating excellent test-retest reliability. Poorer quality of life (QoL) at follow-up, measured by the MacDQoL present QoL overview item, was associated with deterioration in both the better eye and binocular distance visual acuity [VA] (r = 0.29; P = .001, r = 0.21; P = .016, respectively; n = 135). There was a positive correlation between deterioration in the Mac. DQoL average weighted impact score and deterioration in both binocular near VA and reading speed (r = 0.20; P = .019, r = 0.18; P = .041, respectively; n = 135). CONCLUSION: The MacDQoL has excellent test-retest reliability. Its sensitivity to change in vision status was demonstrated in correlational analyses. The measure indicates that the negative impact of AMD on QoL increases with increasing severity of visual impairment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: The aim of this study was to assess the impact of hand washing regimes on lipid transference to contact lenses. The presence of lipids on contact lenses can affect visual acuity and enhance spoilation. Additionally, they may even mediate and foster microbial transfer and serve as a marker of potential dermal contamination. Methods and materials: A social hand wash and the Royal College of Nursing (RCN) hand wash were investigated. A 'no-wash regime' was used as control. The transfer of lipids from the hand was assessed by Thin Layer Chromatography (TLC). Lipid transference to the contact lenses was studied through fluorescence spectroscopy (FS). Results: Iodine staining, for presence of lipids, on TLC plates indicated the 'no-wash regime' score averaged at 3.4 ± 0.8, the social wash averaged at 2.2 ± 0.9 and the RCN averaged at 1.2 ± 0.3 on a scale of 1-4. The FS of lipids on contact lenses for 'no washing' presented an average of 28.47 ± 10.54 fluorescence units (FU), the social wash presented an average of 13.52 ± 11.12. FU and the RCN wash presented a much lower average 6.47 ± 4.26. FU. Conclusions: This work demonstrates how the method used for washing the hands can affect the concentration of lipids, and the transfer of these lipids onto contact lenses. A regime of hand washing for contact lens users should be standardised to help reduce potentially transferable species present on the hands. © 2011 British Contact Lens Association.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: As light-emitting diodes become more common as the light source for low vision aids, the effect of illumination colour temperature on magnifier reading performance was investigated. Methods: Reading ability (maximum reading speed, critical print size, threshold near visual acuity) using Radner charts and subjective preference was assessed for 107 participants with visual impairment using three stand magnifiers with light emitting diode illumination colour temperatures of 2,700 K, 4,500 K and 6,000 K. The results were compared with distance visual acuity, prescribed magnification, age and the primary cause of visual impairment. Results: Reading speed, critical print size and near visual acuity were unaffected by illumination colour temperature (p > 0.05). Reading metrics decreased with worsening acuity and higher levels of prescribed magnification but acuity was unaffected by age. Each colour temperature was preferred and disliked by a similar number of patients and was unrelated to distance visual acuity, prescribed magnification and age (p > 0.05). Patients had better near acuity (p = 0.002), critical print size (p = 0.034) and maximum reading speed (p <0.001), and the improvement in near from distance acuity was greater (p = 0.004) with their preferred rather than least-liked colour temperature illumination. Conclusion: A range of colour temperature illuminations should be offered to all visually impaired individuals prescribed with an optical magnifier for near tasks to optimise subjective and objective benefits.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: To determine the best method of estimating the optimum magnification needed by visually impaired patients. Methods: The magnification of low vision aids prescribed to 187 presbyopic visually impaired patients for reading newspapers or books was compared with logMAR distance and near acuity (at 25 cm) and magnification predicted by +4 D step near additions. Results: Distance letter (r = 0.58) and near word visual acuity (r = 0.67) were strongly correlated to the prescribed magnification as were predictive formulae based on these measures. Prediction using the effect of proximal magnification resulted in a similar correlation (r = 0.67) and prediction was poorer in those who did not benefit from proximal magnification. The difference between prescribed and predicted magnification was found to be unrelated to the condition causing visual impairment (F = 2.57, p = 0.08), the central visual field status (F = 0.57, p = 0.57) and patient psychology (F = 0.44, p = 0.51), but was higher in those prescribed stand magnifiers than high near additions (F = 5.99, p < 0.01). Conclusions: The magnification necessary to perform normal visual tasks can be predicted in the majority of cases using visual acuity measures, although measuring the effect of proximal magnification demonstrates the effect of stronger glasses and identifies those in whom prescribed magnification is more difficult to predict.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To compare distance and near visual performance with a zero-aberration aspheric intraocular lens (IOL) (Softec HD, Lenstec, Inc. FL, USA) with that of an otherwise identical, but spherical IOL (Softec 1). Setting: Department of Ophthalmology, Solihull Hospital, West Midlands, United Kingdom. Methods: This prospective study comprised 37 patients with a Softec 1 spherical IOL implanted in one eye, who underwent phacoemulsification and received the Softec HD aspheric IOL in the fellow eye. One month post-operatively, unaided distance and near vision, residual refraction, best spectacle corrected distance and near visual acuity, reading speed, pseudoaccommodation and photopic contrast sensitivity were recorded. Wavefront analysis enabled comparison of higher order aberrations between the IOLs. Results: Prior to surgery, the Softec 1 and Softec HD eyes were not significantly different. Post-operatively, unaided vision, best spectacle corrected visual acuity and residual refraction were not significantly different between the eyes, nor were there significant differences observed between the measured wavefront aberrations. Once implanted, the range of focus was significantly better in the Softec HD IOL eye than the Softec 1 IOL eye and, although reading speed was equivalent to the Softec 1 eye, the print size at which this could be achieved was significantly smaller. Conclusions: Depth of field was significantly improved with the aspheric IOL compared with the spherical IOL, without any compromise in distance visual performance between the two IOLs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dementia, including Alzheimer’s disease (AD), is a major disorder causing visual problems in the elderly population. The pathology of AD includes the deposition in the brain of abnormal aggregates of ß-amyloid (Aß) in the form of senile plaques (SP) and abnormally phosphorylated tau in the form of neurofibrillary tangles (NFT). A variety of visual problems have been reported in patients with AD including loss of visual acuity (VA), colour vision and visual fields; changes in pupillary response to mydriatics, defects in fixation and in smooth and saccadic eye movements; changes in contrast sensitivity and in visual evoked potentials (VEP); and disturbances of complex visual functions such as reading, visuospatial function, and in the naming and identification of objects. Many of these changes are controversial with conflicting data in the literature and no ocular or visual feature can be regarded as particularly diagnostic of AD. In addition, some pathological changes have been observed to affect the eye, visual pathway, and visual cortex in AD. The optometrist has a role in helping a patient with AD, if it is believed that signs and symptoms of the disease are present, so as to optimize visual function and improve the quality of life. (J Optom 2009;2:103-111 ©2009 Spanish Council of Optometry)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Contrast susceptibility is defined as the difference in visual acuity recorded for high and low contrast optotypes. Other researchers refer to this parameter as "normalised low contrast acuity". Pilot surveys have revealed that contrast susceptibility deficits are more strongly related to driving accident involvement than are deficits in high contrast visual acuity. It has been hypothesised that driving situation avoidance is purely based upon high contrast visual acuity. Hence, the relationship between high contrast visual acuity and accidents is masked by situation avoidance whilst drivers with contrast susceptibility deficits remain prone to accidents in poor visibility conditions. A national survey carried out to test this hypothesis provided no support for either the link between contrast susceptibility deficits and accidents involvement or the proposed hypothesis. Further, systematically worse contrast susceptibility scores emerged from vision screeners compared to wall mounted test charts. This discrepancy was not due to variations in test luminance or instrument myopia. Instead, optical imperfections inherent in vision screeners were considered to be responsible. Although contrast susceptibility is unlikely to provide a useful means of screening drivers' vision, previous research does provide support for its ability to detect visual deficits that may influence everyday tasks. In this respect, individual contrast susceptibility variations were found to reflect variations in the contrast sensitivity function - a parameter that provides a global estimate of human contrast sensitivity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Separate physiological mechanisms which respond to spatial and temporal stimulation have been identified in the visual system. Some pathological conditions may selectively affect these mechanisms, offering a unique opportunity to investigate how psychophysical and electrophysiological tests reflect these visual processes, and thus enhance the use of the tests in clinical diagnosis. Amblyopia and optical blur were studied, representing spatial visual defects of neural and optical origin, respectively. Selective defects of the visual pathways were also studied - optic neuritis which affects the optic nerve, and dementia of the Alzheimer type in which the higher association areas are believed to be affected, but the primary projections spared. Seventy control subjects from 10 to 79 years of age were investigated. This provided material for an additional study of the effect of age on the psychophysical and electrophysiological responses. Spatial processing was measured by visual acuity, the contrast sensitivity function, or spatial modulation transfer function (MTF), and the pattern reversal and pattern onset-offset visual evoked potential (VEP). Temporal, or luminance, processing was measured by the de Lange curve, or temporal MTF, and the flash VEP. The pattern VEP was shown to reflect the integrity of the optic nerve, geniculo striate pathway and primary projections, and was related to high temporal frequency processing. The individual components of the flash VEP differed in their characteristics. The results suggested that the P2 component reflects the function of the higher association areas and is related to low temporal frequency processing, while the Pl component reflects the primary projection areas. The combination of a delayed flash P2 component and a normal latency pattern VEP appears to be specific to dementia of the Alzheimer type and represents an important diagnostic test for this condition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The extent to which the surface parameters of Progressive Addition Lenses (PALs) affect successful patient tolerance was investigated. Several optico-physical evaluation techniques were employed, including a newly constructed surface reflection device which was shown to be of value for assessing semi-finished PAL blanks. Detailed physical analysis was undertaken using a computer-controlled focimeter and from these data, iso-cylindrical and mean spherical plots were produced for each PAL studied. Base curve power was shown to have little impact upon the distribution of PAL astigmatism. A power increase in reading addition primarily caused a lengthening and narrowing of the lens progression channel. Empirical measurements also indicated a marginal steepening of the progression power gradient with an increase in reading addition power. A sample of the PAL wearing population were studied using patient records and questionnaire analysis (90% were returned). This subjective analysis revealed the reading portion to be the most troublesome lens zone and showed that patients with high astigmatism (> 2.00D) adapt more readily to PALs than those with spherical or low cylindrical (2.00D) corrections. The psychophysical features of PALs were then investigated. Both grafting visual acuity (VA) and contrast sensitivity (CS) were shown to be reduced with an increase in eccentricity from the central umbilical line. Two sample populations (N= 20) of successful and unsuccessful PAL wearers were assessed for differences in their visual performance and their adaptation to optically induced distortion. The possibility of dispensing errors being the cause of poor patient tolerance amongst the unsuccessful wearer group was investigated and discounted. The contrast sensitivity of the successful group was significantly greater than that of the unsuccessful group. No differences in adaptation to or detection of curvature distortion were evinced between these presbyopic groups.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Although the role of ophthalmic factors in dyslexia remains the subject of controversy, recent research has indicated that the correlates of dyslexia may include binocular dysfunction, unstable motor ocular dominance, a deficit of the transient visual subsystem, and an anomaly that can be treated with tinted lenses. These features, typically, have been studied in isolation and their inter-relationship has received little attention. The aim of the present research was to investigate ophthalmic factors in dyslexia, with a particular emphasis on the interaction between optometric variables. Further aims were to establish the most appropriate investigative techniques for optometric practice and to explore the relationship between optometric and psychometric variables. A pilot study was used to refine the experimental design for a subsequent detailed study of 39 children with a specific reading disability and 43 good readers, who were selected from 240 children. The groups were matched for age, sex, and performance IQ. The following factors emerged as correlates of dyslexia: slight impaired visual acuity; reduced vergence amplitudes; increased vergence instability; decreased accommodative amplitude; poor peformance at tests that were designed to assess the function of the transient visual system; and slightly slower performance at a non-verbal simulated reading visual search task. The `transient system deficit', as measured by reduced flicker sensitivity, was significantly associated with decreased accommodative and vergence amplitudes. This links the motor and sensory visual correlates of dyslexia. Although the binocular dysfunction was correlated with increased symptoms, the difference in the groups' simulated reading visual search task performance was largely attributable to psychometric variables. The results suggest tht optometric problems may be a contributory factor in dyslexia, but are unlikely to play a key causative role. Several optometric variables were confounded by psychometric parameters, and this interaction should be a priority for future investigation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this thesis was to develop standards of best practice for the subjective assessment of near visual function in presbyopia. Near visual acuity (VA) is a quick and simple measure but an assessment of the maximum reading speed and the smallest print size that can maintain this are equally important, to gain a better reflection of real world visual function. These metrics are dependent on the amplitude of accommodation (AoA) and often this must be evaluated using subjective techniques. Defocus curves are less susceptible than the push-up/push-down test to the influence of blur tolerance but their implementation must be standardised such that letter sequences and the order of lens presentation are randomised, to avoid memory effects, whilst the AoA should be quantified as the range of defocus for which only the best VA is maintained. In addition to such clinical assessments, subjective questionnaire evaluations are also important, to determine whether at least an individual’s needs are met. The Near Activity Visual Questionnaire (NAVQ) developed in this thesis can be used for this. Using these standardised near vision metrics it is shown that visual performance with monovision and multifocal contact lenses is comparable whilst initial outcomes of single optic ‘accommodating’ intraocular lens implantation are unlikely to be sustained in the long-term.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The work utilising a new material for contact lenses has fallen into three parts: Physioloeical considerations: Since the cornea is devoid of blood vessels, its oxygen is derived from the atmosphere. Early hydrophilic gel contact lenses interrupted the flow of oxygen and corneal insult resulted. Three techniques of fenestration were tried to overcome this problem. High speed drilling with 0.1 mm diameter twist drills. was found to be mechanically successful, but under clinical conditions mucous blockage of the fenestrations occurred. An investigation was made into the amount of oxygen arriving at the corneal interface; related to gel lens thickness. The results indicated an improvement in corneal oxygen as lens thickness was reduced. The mechanism is thought to be a form of mechanical pump. A series of clinical studies con:firmed the experimental work; the use of thin lenses removing the symptoms of corneal hypoxia. Design: The parameters of lens back curvature. lens thickness and lens diameter have been isolated and related to three criteria of vision (a) Visual acuity. (b) Visual stability and (c) Induced astigmatism. From the results achieved a revised and basically successful design of lens has been developed. Comparative study: The developed form of lens was compared with traditional lenses in a controlled survey. Twelve factors were assessed over a twenty week period of wear using a total of eighty four patients. The results of this study indicate that whilst the expected changes were noted with the traditional lens wearers, gel lens wearers showed no discernible change in any of the factors measured. ldth the exception of' one parameter. In addition to a description of' the completed l'iork. further investigations are ·sug~ested l'lhich. it is hoped. l'iould further improve the optical performance of gel lenses.