68 resultados para Higher-order Shear Deformation Theory


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The tear film, cornea and lens dictate the refractive power of the eye and the retinal image quality is principally defined by diffraction, whole eye wavefront error, scatter, and chromatic aberration. Diffraction and wave aberration are fundamentally pupil diameter dependent; however scatter can be induced by refractive surgery and in the normal ageing eye becomes an increasingly important factor defining retinal image quality. The component of visual quality most affected by the tear film, refractive surgery and multifocal contact and intraocular lenses is the wave aberration of the eye. This body of work demonstrates the effects of each of these anomalies on the visual quality of the eye. When assessing normal or borderline self-diagnosed dry eye subjects using aberrometry, combining lubricating eye drops and spray does not offer any benefit over individual products. However, subjects perceive a difference in comfort for all interventions after one hour. Total higher order aberrations increase after laser assisted sub-epithelial keratectomy performed using a solid-state laser on myopes, but this causes no significant decrease in contrast sensitivity or increase in glare disability. Mean sensitivity and reliability indices for perimetry were comparable to pre-surgery results. Multifocal contact lenses and intraocular lenses are designed to maximise vision when the patient is binocular, so any evaluation of the eyes individually is confounded by reduced individual visual acuity and visual quality. Different designs of aspheric multifocal contact lenses do not provide the same level of visual quality. Multifocal contact lenses adversely affect mean deviation values for perimetry and this should be considered when screening individuals with multifocal contact or intraocular lenses. Photographic image quality obtained through a multifocal contact or intraocular lens appears to be unchanged. Future work should evaluate the effect of these anomalies in combination; with the aim of providing the best visual quality possible and supplying normative data for screening purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is a cross-national study testing a framework relating cultural descriptive norms to entrepreneurship in a sample of 40 nations. Based on data from the Global Leadership and Organizational Behavior Effectiveness project, we identify two higher-order dimensions of culture – socially supportive culture (SSC) and performance-based culture (PBC) – and relate them to entrepreneurship rates and associated supply-side and demand-side variables available from the Global Entrepreneurship Monitor. Findings provide strong support for a social capital/SSC and supply-side variable explanation of entrepreneurship rate. PBC predicts demand-side variables, such as opportunity existence and the quality of formal institutions to support entrepreneurship.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dramatic growth in e-business is manifest in phenomena such as the surge in internet retailing, the boom in social media based marketing communications, and the centrality of e-commerce to many organizations’ core strategies. Despite this the precise implications of e-business for marketing strategy remain little-understood. In order to guide theory development and practice in the marketing strategy domain, it is of fundamental importance to take stock of the impact that e-business has had upon strategic marketing. Therefore, this chapter develops a conceptual framework in order to explicate the implications of e-business for strategic marketing theory and practice. We find that the impact of e-business on strategic marketing is far-reaching; influencing not only isolated departments, but the organization as a whole. Finally, we conclude that whilst organizations should be alert to the dynamic opportunities and threats posed by e-business, the guiding principle of value creation should not be forgotten.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To determine whether eyes implanted with the Lenstec KH-3500 "accommodative" intraocular lenses (IOLs) have improved subjective and objective focusing performance compared to a standard monofocal IOLs. Methods: 28 participants were implanted monocularly with a KH-3500 " accommodative" IOL and 20 controls with a Softec1 IOL. Outcome measures of refraction, visual acuity, subjective amplitude of accommodation, objective accommodative stimulus response curve, aberrometry, and Scheimpflug imaging were taken at ∼3 weeks and repeated after 6 months. Results: Best corrected acuity with the KH-3500 was 0.06 (SD 0.13) logMAR at distance and 0.58 (0.20) logMAR at near. Accommodation was 0.39 (0.53) D measured objectively and 3.1 (1.6) D subjectively. Higher order aberrations were 0.87 (0.85) μm and lower order were 0.24 (0.39) μm. Posterior subcapsular light scatter was 0.95% (1.37%) greater than IOL clarity. In comparison, all control group measures were similar except objective (0.17 (0.13) D; p = 0.032) and subjective (2.0 (0.9) D; p = 0.009) amplitude of accommodation. Six months following surgery, posterior subcapsular scatter had increased (p<0.01) in the KH-3500 implanted subjects and near word acuity had decreased (p<0.05). Conclusions: The objective accommodating effects of the KH-3500 IOL appear to be limited, although the subjective and objective accommodative range is significantly increased compared to control subjects implanted with conventional IOLs. However, this "accommodative" ability of the lens appears to have decreased by 6 months post-surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

C–C bond-forming, cross-coupling reactions of organohalides with nucleophilic compounds, catalysed by palladium, are amongst the most important chemical reactions available to the synthetic chemist. The intimate mechanisms of these reactions, involving Pd0/PdII redox steps, have been of great historical interest and continue to be so. The myriad of possible mechanisms is reviewed in this chapter. The interplay of mononuclear Pd species with higher order Pd species, e.g. nanoclusters/nanoparticles are considered as being equally important in cross-coupling reaction mechanisms. A focus is placed on trichotomic behaviour of cross-coupling catalytic manifolds, from homogeneous to hybrid homogeneous–heterogeneous to truly heterogeneous behaviour. For the latter, surface chemistry and metal atom leaching (and various experimental techniques) are broadly discussed. It is now clear that mechanism for general cross‐coupling reactions, that is as presented to undergraduate students studying Chemistry degrees across the world, is undoubtedly more complex than first thought. New opportunities for catalyst design have therefore emerged in the area of Pd nanoparticles and nanocatalysis, with some wonderful applications especially in chemical biology, providing a snapshot of what the future might hold.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a simulated genetic algorithm (GA) model of scheduling the flow shop problem with re-entrant jobs. The objective of this research is to minimize the weighted tardiness and makespan. The proposed model considers that the jobs with non-identical due dates are processed on the machines in the same order. Furthermore, the re-entrant jobs are stochastic as only some jobs are required to reenter to the flow shop. The tardiness weight is adjusted once the jobs reenter to the shop. The performance of the proposed GA model is verified by a number of numerical experiments where the data come from the case company. The results show the proposed method has a higher order satisfaction rate than the current industrial practices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present femtosecond laser inscribed phase masks for the inscription of Bragg gratings in optical fibres. The principal advantage is the flexibility afforded by the femtosecond laser inscription, where sub-surface structures define the phase mask period and mask properties. The masks are used to produce fibre Bragg gratings having different orders according to the phase mask period. The work demonstrates the incredible flexibility of femtosecond lasers for the rapid prototyping of complex and reproducible mask structures. We also consider three-beam interference effects, a consequence of the zeroth-order component present in addition to higher-order diffraction components. © 2012 SPIE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine by wavefront analysis the difference between eyes considered normal, eyes diagnosed with keratoconus, and eyes that have undergone penetrating keratoplasty METHODS: The Nidek OPD-Scan wavefront aberrometer was used to measure ocular aberrations out to the sixth Zernike order. One hundred and thirty eyes that were free of ocular pathology, 41 eyes diagnosed with keratoconus, and 8 eyes that had undergone penetrating keratoplasty were compared for differences in root mean square value. Three and five millimeter root mean square values of the refractive power aberrometry maps of the three classes of eyes were compared. Radially symmetric and irregular higher order aberration values were compared for differences in magnitude. RESULTS: Root mean square values were lower in eyes free of ocular pathology compared to eyes with keratoconus and eyes that had undergone penetrating keratoplasty. The aberrations were larger with the 5-mm pupil. Coma and spherical aberration values were lower in normal eyes. CONCLUSION: Wavefront aberrometry of normal, pathological, and eyes after surgery may help to explain the visual distortions encountered by patients. The ability to measure highly aberrated eyes allows an objective assessment of the optical consequences of ocular pathology and surgery. The Nidek OPD-Scan can be used in areas other than refractive surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study investigated how aberration-controlling, customised soft contact lenses corrected higher-order ocular aberrations and visual performance in keratoconic patients compared to other forms of refractive correction (spectacles and rigid gas-permeable lenses). Methods: Twenty-two patients (16 rigid gas-permeable contact lens wearers and six spectacle wearers) were fitted with standard toric soft lenses and customised lenses (designed to correct 3rd-order coma aberrations). In the rigid gas-permeable lens-wearing patients, ocular aberrations were measured without lenses, with the patient's habitual lenses and with the study lenses (Hartmann-Shack aberrometry). In the spectacle-wearing patients, ocular aberrations were measured both with and without the study lenses. LogMAR visual acuity (high-contrast and low-contrast) was evaluated with the patient wearing their habitual correction (of either spectacles or rigid gas-permeable contact lenses) and with the study lenses. Results: In the contact lens wearers, the habitual rigid gas-permeable lenses and customised lenses provided significant reductions in 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS and higher-order RMS error (p ≤ 0.004). In the spectacle wearers, the standard toric lenses and customised lenses significantly reduced 3rd-order RMS and higher-order RMS errors (p ≤ 0.005). The spectacle wearers showed no significant differences in visual performance measured between their habitual spectacles and the study lenses. However, in the contact lens wearers, the habitual rigid gas-permeable lenses and standard toric lenses provided significantly better high-contrast acuities compared to the customised lenses (p ≤ 0.006). Conclusions: The customised lenses provided substantial reductions in ocular aberrations in these keratoconic patients; however, the poor visual performances achieved with these lenses are most likely to be due to small, on-eye lens decentrations. © 2014 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically-powered RGP (rigid gas-permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15°) and translation (up to 1mm) from their ideal position. Methods: The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point-spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher-order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation. Results: In agreement with the results of other authors, the RGP lenses markedly reduced both lower-order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies. Conclusions: At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort. © 2012 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To assess visual performance and ocular aberrations in keratoconic patients using toric soft contact lenses (SCL), rigid-gas-permeable (RGP) contact lenses and spectacle lens correction. Methods: Twenty-two keratoconus patients (16 RGP lens wearers and six spectacle wearers) were fitted with toric SCL. Ocular aberrations were measured with and without the patient's habitual RGP lenses and with the SCL in place. In the spectacle wearers, aberrations were measured with and without the SCL. Visual performance (high- and low-contrast visual acuity) was evaluated with the patient's habitual correction and with the SCL. Results: In the RGP lens wearers both the habitual lenses and the toric SCL significantly reduced coma, trefoil, 3rd-order, 4th-order cylinder and higher-order root-mean-square (RMS) aberrations (p≤0.015). In the spectacle wearers the toric SCL significantly reduced coma, 3rd-order and higher-order RMS aberrations (p≤0.01). The patients' habitual RGP lenses gave better low-contrast acuity (p≤0.006) compared to the toric SCL; however, no significant difference was found between lens types for high-contrast acuity (p=0.10). In the spectacle wearers no significant differences in visual performance measurements were found between the patients' spectacles and the toric SCL (p≥0.06). Conclusion: The results show that RGP lenses provided superior visual performances and greater reduction of 3rd-order aberrations compared to toric SCL in this group of keratoconic patients. In the spectacle-wearing group, visual performance with the toric SCL was found to be comparable to that measured with spectacles. Nevertheless, with the exception of spherical aberration, the toric SCL were successful in significantly reducing uncorrected higher-order aberrations. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To explore the repeatability of lower-order and higher-order ocular aberrations measured in patients with keratoconus. Methods: The IRX-3 (Imagine Eyes, Paris, France) aberrometer was used to record lower-order and higher-order aberrations in 31 eyes of 31 patients with keratoconus. Four monocular measurements were taken consecutively for each patient. The aberrometry data were analysed up to the 5th Zernike order for a 4-mm pupil diameter. The data were evaluated using repeated-measures anova and Friedman analyses. Repeatability was analysed using within-subject standard deviation (SW) and the repeatability limit (r) calculated as 1.96 ×√2×Sw. Results: Of the 11 aberration terms evaluated, the repeatability of Z (2,0) (mean= 1.36μm; SW=0.09μm; r=0.26μm); Z (2,±2) RMS (mean=1.05μm; SW= 0.09μm; r=0.24μm) and Z (4,0) aberrations (mean=0.34μm; SW=0.09 μm; r=0.24μm) showed the highest variability. In contrast, Z (3,±1) RMS aberrations (mean=0.85μm; SW=0.06μm; r=0.16μm) and Z (4,±2) RMS aberrations (mean=0.40μm; SW=0.07μm; r=0.18μm) showed comparatively better repeatability. Conclusions: The lower-order and higher-order aberrations measured in this group of keratoconic patients showed higher levels of variability compared to previous investigations of visually-normal subjects. These results may be of interest to eyecare practitioners involved in the design and fitting of aberration-controlling contact lenses for patients with keratoconus. © 2011 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

While the literature has suggested the possibility of breach being composed of multiple facets, no previous study has investigated this possibility empirically. This study examined the factor structure of typical component forms in order to develop a multiple component form measure of breach. Two studies were conducted. In study 1 (N = 420) multi-item measures based on causal indicators representing promissory obligations were developed for the five potential component forms (delay, magnitude, type/form, inequity and reciprocal imbalance). Exploratory factor analysis showed that the five components loaded onto one higher order factor, namely psychological contract breach suggesting that breach is composed of different aspects rather than types of breach. Confirmatory factor analysis provided further evidence for the proposed model. In addition, the model achieved high construct reliability and showed good construct, convergent, discriminant and predictive validity. Study 2 data (N = 189), used to validate study 1 results, compared the multiple-component measure with an established multiple item measure of breach (rather than a single item as in study 1) and also tested for discriminant validity with an established multiple item measure of violation. Findings replicated those in study 1. The findings have important implications for considering alternative, more comprehensive and elaborate ways of assessing breach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We test for departures from normal and independent and identically distributed (NIID) log returns, for log returns under the alternative hypothesis that are self-affine and either long-range dependent, or drawn randomly from an L-stable distribution with infinite higher-order moments. The finite sample performance of estimators of the two forms of self-affinity is explored in a simulation study. In contrast to rescaled range analysis and other conventional estimation methods, the variant of fluctuation analysis that considers finite sample moments only is able to identify both forms of self-affinity. When log returns are self-affine and long-range dependent under the alternative hypothesis, however, rescaled range analysis has higher power than fluctuation analysis. The techniques are illustrated by means of an analysis of the daily log returns for the indices of 11 stock markets of developed countries. Several of the smaller stock markets by capitalization exhibit evidence of long-range dependence in log returns. © 2012 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We experimentally demonstrate adiabatic soliton propagation in the fundamental mode of a few mode optical fibre and more complex behaviour in a higher order mode, indicating that the impact of nonlinearities differs for each mode.